STEP 4 Adjustments
10
Leveling adjustment
If needed, TV can be leveled by ±3 degrees via adjusting the 4 nuts with the
open-end wrench .
Tighten
±3°
Tilting adjustment
If needed, TV can be tilted by +5~-13 degrees via adjusting the 2 nuts with
the open-end wrench .
+5°
-13°
Tighten
Tighten
C
C
C
3/8"
(10mm)
Product DimensionsSTEP 3 Hang and Secure TV to Wall Plate
+45°/-45°
Before hanging TV, please conduct "wall plate installation integrity test" first.
3-1 Wall Plate Installation Integrity Test
3-2 Hang and Secure TV to Wall Plate
Release preassembled screws down on brackets, hang TV with brackets onto the
Plate, then fasten the safety screws.
99 LBS (45KG)
2.75"(70mm)
OPTION B: Solid Concrete or Brick Wall Installation
A-3 Drill pilot holes
A-4
B-1 Min. 8"
(203mm)
DANGER
B-2
B-3
B-4
2.75"(70mm)
678
911
STEP 2 (Continued)STEP 2 (Continued) STEP 2 (Continued)
CAUTION: To avoid potential personal
injury or property damage:
All 4 lag bolts MUST BE firmly tightened
to prevent unwanted movement of the wall
plate assembly. Ensure the wall plate
assembly is securely fastened to the wall
before continuing on to the next step.
To prevent the TV falling down, the Arrow
Must Keep UP at this step!!
A
No! Install wall plate using lag bolts,
washer and anchor with Socket
Wrench, NO Electrodrill.
7/32"
(5.5mm)
UP
A
BB
A
UP
TV
1 2
TV must be hanged
up by two person
Bubble
Level
CAUTION: Do not use
in drywall or wood.
No!
Install wall plate using lag bolts
and washer with Socket Wrench,
NO Electrodrill.
CAUTION: To avoid potential personal
injury or property damage:
All 4 lag bolts MUST BE firmly tightened
to prevent unwanted movement of the wall
plate assembly. Ensure the wall plate
assembly is securely fastened to the wall
before continuing on to the next step.
To prevent the TV falling down, the Arrow
Must Keep UP at this step!!
A
+3°/-3°
Contact us to have
these additional pieces
shipped directly to you.
Ф10×61mm
Concrete wall anchor (NOT INCLUED)
435mm/17.13"
184mm
/7.24"
130mm
/5.12"
33.5mm
/1.32"
406mm/16"
254mm/10"
110mm/4.33"
MIN:
74mm
/2.91"
MAX:397mm/15.63"
75mm/2.95"
MAX:400mm/16"
MIN:75mm/3"
435mm/17.13"
130mm
/5.12"
Φ
8.5mm/0.33"
MAX:
400mm/16"
MIN:
75mm/3"
430mm
/16.93"
+5° -13°
Ensure the lag bolts to be screwed
into the studs tightly and securely.
Safety
Screw
Phillips
Screwdriver
Loosen
Loosen
Loosen