Danfoss PVG 32 Installation guide

Category
Signal cables
Type
Installation guide
V310115.A
Installation Guide
Cable kit for
PVED-CX
© Danfoss A/S, 2014-03 11070083 • Rev EB • Mar 2014 1
11070083
11070083
JN
J3
J0
J2
J1
V310190.B
WWARNING Cable is specific designed for use with PVED-CX
WWARNING By cable handling below 0°C [32°F]avoid twisting and rough handling.
WWARNING When changing parameters or replacing cables or modules system safety can be influenced.
Always verify system after changes.
Run ASSIST test to verify cable connections.
2 11070083 • Rev EB • Mar 2014 © Danfoss A/S, 2014-03
Wiring J0
Description Color
CAN-L Yellow
CAN-H Orange
Ground Brown
Vbat Red
Vbat2 Green
Version with AMP JPT connector
Grade of enclosure IP 66
Neighbor Guide
Node connector J1 J2 J3 ... Jn
Neighbor connector Jn J1 J2 ... Jn-1
Example
Node Id 20 21 22 ... 26
Neighbor node Id 26 20 21 ... 25
V310 023.A
Vbat 2 out
Vbat 2 in
Vbat 3
Not connected
Sp pos in
Vbat
Ground
CAN H
CAN L
Sp pos out
J0
J1
J2
JN
Strip + Wirequard
51418
2x1.5 mm
2
+ 3x0.75 mm
2
Roboslepp
8x0.75 mm
2
Roboslepp
4000±50
135
Marking Part No, + prod week-year
V310192.B
V310191.B
Voltage and power
Vbat, Vbat2, Ground
Max 36 V
Max 80 W
Ambient temperature
Use -30° +90°C [-22° +19 4°F ]
Storage -40° +100°C [-4 +212°F ]
  • Page 1 1