Lang LCG-401DP User manual

Type
User manual
LANG MANUFACTURING COMPANY • 6500 Merrill Creek Parkway, Everett, WA 98203
TOLL FREE: 800.882.6368 • FAX: 425.349.2733 • www.langworld.com
Item No.
Project
Quantity
Gas, 20-Pan, Full Size Combi Oven Model: LCG-401-DP
CONSTRUCTION FEATURES
Heavy duty 304 Series stainless steel construction, with attractive No. 4 finish
Cooking compartment is 316 Series stainless
Heavy duty compartment door hinged right, with large double pane,
tempered glass window
•Two oversize, heavy duty cam-lock door handles
Powerful blower mounted on left side of compartment, with baffles and
safety screen
Four shielded cooking compartment lights
20 position stainless steel pan rack frame with 10 stainless steel wire
racks provided
Stainless steel pan rack transport trolley included
Removable stainless steel condensate collection tray mounted below door
12” legs with adjustable bullet feet [For floor mounting]
PERFORMANCE FEATURES
Choice of five cooking modes
86 to 482˚F operating temperature range [in OVEN & COMBI modes]
217˚F SteamPLUS™ STEAM mode temperature, for faster cooking
10-90% humidity control [Proofing Capability]
Boilerless steam generation system for easier cleaning, less maintenance,
less downtime & lower utility costs
Air-tight cooking compartment with slight 1/2 psi overpressure
In-compartment meat probe
Spray gun and hose provided as standard for quick and easy
compartment cleaning
Recessed, wash down resistant left side control panel [IPX-5 Water Tested]
CONTROL PACKAGE [Digital Programmable]
All touch-pad controls
OVEN, STEAM, COMBI, RETHERM & [230-257˚F] SuperSteam™ modes
Cook-to-[Meat] Probe standard
Both set & actual time & temp readouts
Humidity key for setting 10-90% steam
Reheat settings, within safe range
System self-test and “Cleaning Due” alert systems
Up to 99 Cook Program memory, with up to 9 steps or stages
Auto-Cook & Hold programming
2-speed fan motor control
®
SHORT/BID SPECIFICATION
Combi Oven shall be a LANG Manufacturing Model LCG-401-DP with
Digital Programmable Control Package, 170,000 BTU/hr. gas
heated 20-pan full-size unit, with: boilerless, in-cavity steam gen-
eration system; SteamPLUS 217˚F standard steam; compartment
humidity control; large double pane glass viewing door, with
easy-open heavy duty cam-lock handles; 316 Series stainless
steel compartment with powerful left-side mounted blower, four
shielded compartment lights; transport trolley, rack frame & 10
pan racks standard; plus a standard 2-year parts & labor warranty,
all the features listed and the options/accessories checked:
STANDARD PRODUCT WARRANTY
Two years, parts & labor
Pan Type Max. Capacity Optimum
18” X 26” Full-Sheet 20 20
12” X 20” Hotel* 40 28
PAN CAPACITY GUIDE
* 2-1/2” deep pans
®
Sheet No. LSP-CO5 (rev. 7/03)
Model LCG-401-DP
(Shown without gas flue)
LANG MANUFACTURING COMPANY • 6500 Merrill Creek Parkway, Everett, WA 98203
TOLL FREE: 800.882.6368 • FAX: 425.349.2733 • www.langworld.com
© 2003 Lang Manufacturing Company Printed in U.S.A. 7/03-M-11794
Due to continuous improvements, specifications subject to change without notice.
Model
E Electrical Requirements
G Gas W Water D Drain
Voltage Total kW Phase Amps/Line
Requirements Requirements Requirements
LCG-401-DP
208V/60Hz 1.9 3 6.0 3/4” NPT 3/4” NPT
1-1/2” NPT
240V/60Hz 1.9 3 6.0
(170,000 BTU/hr) (.5 GPM @ 30 PSI)
Model Height x Width x Depth
Clearance from
Weight
Freight
combustible surface
Actual Shipping
Class
87.8” x 52.5” x 40.0”
Top*: 11-1/4” (290mm)
992 lbs. 1,036 lbs.
LCG-401-DP
2229mm x 1334mm x 1016mm
Sides**: 2” (51mm)
450 kg 470 kg
70
Back: 4” (100mm)
OPTIONS & ACCESSORIES
Stainless steel roll-in rack frame, 20-pan guides [std. spacing]
Stainless steel roll-in rack frame, 14-pan guides [3.34” spacing]
Stainless steel roll-in rack for 12” plates
Thermal cover for roll-in plate rack
Stainless steel wheeled support stand
Extra wire pan racks [10 provided as std.]
Additional transport trolley
Two step safety release door latch
HACCP time/temp data port
INSTALLATION REQUIREMENTS
•G Specify: natural gas or propane gas:
via 3/4” NPT connection
•E208/240V, 3-Phase, 50/60 Hz electrical connection
•W Two 3/4” NPT cold water connections
•D 1-1/2” NPT vended drain connection
Installation under approved vent hood required. Flue gas vent stack provided
as standard
[All connections from unit bottom. See below for location and required
delivery rates]
Sheet No. LSP-CO5 (rev. 7/03)
.8"
19mm
W W TWO WATER
CONNECTIONS
3.5"
89mm
6.0"/152mm
33.5"
851mm
1.0"
25mm
E ELECTRIC
CONNECTION
2.5"
/64mm
1.5"/38mm
8.0"/203mm
2.5"
64mm
1.5"
38mm
D
DRAIN
CONNECTION
52.5"
1334mm
3.89"
99mm
.8"
19mm
G GAS
CONNECTION
14.0"
356mm
4.0"
102mm
53.0"
1346mm
25.0"
635mm
52.5"
1334mm
14.0"
356mm
11.3"/286mm
5.5"
140mm
41.5"
1054mm
64.5"
1638mm
87.8"
2229mm
GAS FLUE
12.0"
305mm
5.5"
140mm
40.0"
1016mm
37.5"
953mm
52.5"
1334mm
76.5"
1943mm
2.5"
64mm
4.5"
114mm
28.8"
730mm
[Front View/Elevation] [Right Side View] [Top View/Plan]
Gas, 20-Pan, Full Size Combi Oven Model: LCG-401-DP
MINIMUM WATER QUALITY
Water: cold water feed
Line Pressure: 30-80 PSI
pH: 7-7.5
Chlorides < 30 PPM
Sulfates < 40 PPM
* Top clearance for flue vent; ** 20” for service access.
CAD SYMBOLS & PRICING
  • Page 1 1
  • Page 2 2

Lang LCG-401DP User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI