  • Hello! I am an AI chatbot trained to assist you with the Ledalite SilkSpace Install Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What safety precautions should be taken while handling the luminaire?
    How do I secure the luminaire to the T-grid?
    What is the size of the drywall ceiling cut-out for a 2'x2' fixture?
    How do I secure the mounting frame in a drywall ceiling?
    Where can I find the wire access plate?
    How do I connect the power feed to the fixture?
www.ledalite.com
page10/30/2020 1
Recessed
ID-42
SilkSpace
Standalone Installation Instructions
Driver Driver
Every fixture contains its own driver
and receives a direct power feed.
Power feed
Driver
Prepare fixtures
Arrange boxed fixtures on the floor
in specified mounting locations;
remove fixtures from boxes.
Lay luminaire into T-grid. Bend mounting
tabs flush against outside of T-grid.
Install in ceiling grid
!
Handling Note
Remove from Packaging
Remove luminaire from packaging,
recycle box.
Lift using both hands from fixture
ends only.
Do not use cross-strap to lift fixture.
(2x4, 1x4)
1
2
3
Secure luminaire and Tie
off to structure
4
Secure luminaire to T-grid with self drilling
8x1/4” sheet metal screws (supplied by
others). Secure luminaire with grid wire or
suitable equivalent per local and national
building codes.
Remove pre-installed wire access plate.
Connect power feed to the leads
provided. Reinstall wire access plate.
Optional Flex Whip is prewired to the
fixture. Insert wire access plate into
wiring cavity. Complete electrical
connection at other end of whip in
accordance with local and national
building code.
Standalone wiring
5a
Flex Whip (Optional)
5b
www.ledalite.com
page10/30/2020 2
Recessed
ID-42
SilkSpace
Continuous Row Installation Instructions
Driver Driver
Every fixture contains its own driver
and receives a direct power feed.
Power feed
Driver
Prepare fixtures
Arrange boxed fixtures on the floor
in specified mounting locations;
remove fixtures from boxes.
Lay luminaire into T-grid. Bend mounting
tabs flush against outside of T-grid.
Install in ceiling grid
Remove from Packaging
Remove luminaire from packaging,
recycle box.
1
2
3
Secure luminaire and Tie off
to structure
4
Secure luminaire to T-grid with self drilling
8x1/4” sheet metal screws (supplied by
others). Secure luminaire with grid wire or
suitable equivalent per local and national
building codes.
Remove pre-installed wire access plate.
Connect power feed to the leads
provided. Reinstall wire access plate.
Optional Flex Whip is prewired to the
fixture. Insert wire access plate into
wiring cavity. Complete electrical
connection at other end of whip in
accordance with local and national
building code.
Remove driver top cover
Attach adjacent fixtures
5
6
!
Handling Note
Lift using both hands from fixture
ends only.
Do not use cross-strap to lift fixture.
(2x4, 1x4)
page
10/30/2020 3
www.ledalite.com
Fixtures size A B
2’x2’ 24 ” (626mm) 24 ” (626mm)
2’x4’ 24 ” (626mm) 48 ” (1235mm)
1’x4’ 12 ” (321mm) 48 ” (1235mm)
Mounting in a drywall ceiling
6
Drywall ceiling cut out
Cut a hole in the drywall with according to
the dimensions in the table above.
7
Installing mounting frame
Insert mounting frame into hole and secure
as shown in step 9.
8
Mounting options
Secure mounting frame by screwing to
wood frame or attaching hangar wires.
!
ATTENTION: Install in accordance with local and national building and electric codes.
Standalone Installation InstructionsID-33 & ID-42
/