Lithonia Lighting TFA Installation guide

Type
Installation guide
Installation Instructions
Outdoor Floodlighting Mounting Brackets
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: RJ52100263
Revision Date: REV A 1/11/10
BRACKETS MUST NOT BE INVERTED.
(Drawings are not to scale, should be used for dimensional
purposes only, and are subject to change without notice)
WARNING
To reduce the risk of death, injury or property damage from fire, electric shock, cuts,
abrasions, falling parts, and other hazards:
Service of the equipment must be performed by qualified service personnel.
Installation and maintenance must be performed by a person familiar with the construction
and operation of this product and any hazards involved. All applicable codes and ordinances
must be followed.
Read this document before installing, servicing, or maintaining this equipment or installing a
lamp. These instructions do not cover all installation, service, and maintenance situations. If
your situation is not covered, or if you do not understand these instructions or additional
information is required, contact Lithonia Lighting or your local Lithonia LIghting Distributor.
Read and follow all warnings and instructions provided by the lamp manufacturer.
WARNING
Before installing, servicing, or maintaining this equipment, follow these general precautions.
To reduce the risk of electrocution:
Make sure the equipment is properly grounded.
Always de-energize the circuit and/or equipment before connecting to, disconnecting
from, or servicing the equipment.
To reduce the risk of fire:
Keep material away that can burn from hot lamp.
Make sure lamps are correctly installed.
Use supply conductors with a minimum installation temperature rating as specified on
equipment.
To reduce the risk of personal injury from cuts, abrasions, or falling parts:
Wear gloves to prevent cuts or abrasions from sharp edges when removing from
carton, handling and maintaining this equipment.
Do not use abrasive materials, glass cleaners or other solvents on reflector or lens.
These substances may damage equipment and cause parts to eventually break and
fall.
Do not install a damaged fixture.
CAUTION: Observe lamp manufacturers recommendations and restrictions on lamp operation,
including but not limited to ballast type, burning position, replacement and cycling. Use only lamps that
comply with applicable ANSI standards.
NOTICE: If lamp is marked it contains mercury. Follow disposal laws. See
www.lamprecycle.org
Lithonia Lighting, a division of Acuity Brands Lighting, Inc., assumes no responsibility for claims arising out of
improper or careless installation or handling of this product.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
DISCONTINUED
Installation Instructions
Part Number: RJ52100263
Revision Date: REV A 1/11/10
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
BRACKETS MUST NOT BE INVERTED.
(Drawings are not to scale, should be used for dimensional
purposes only, and are subject to change without notice)
Outdoor Floodlighting Mounting Brackets
Installation: For use with yoke mounted floodlights or the TV sportslighter’s standard mounting. Secure to the wood pole with mounting
hardware provided by others. Two (2) 13/16” holes are located on C-channel for mounting. The length for all mounting hardware not
provided will be dependent on the surface structure.
2-Light Wood Pole Cross Arm.
(FCX2)
3-Light Wood Pole Cross Arm.
(FCX3)
4-Light Wood Pole Cross Arm.
(FCX4)
DISCONTINUED
Installation Instructions
Outdoor Floodlighting Mounting Brackets
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
Part Number: RJ52100263
Revision Date: REV A 1/11/10
BRACKETS MUST NOT BE INVERTED.
(Drawings are not to scale, should be used for dimensional
purposes only, and are subject to change without notice)
Description: Steel Square Pole Bracket (FSPB)
Installation: For use with existing square steel poles (4” or larger). Mounting
holes should be drilled completely through to the opposite side of the pole.
Take caution to avoid existing wires. A wire-way is also necessary for access
to make connections. Note: Wire-way and mounting holes not to exceed 2
inches in diameter. Secure the FSPB to surface with (2) 1/2” fasteners (not
provided). Secure the 2-3/8” slipfitter to the FSPB by tightening set screws.
EPA: 0.6; Weight 6.2 lbs
Installation:
Secure the FRWB to
surface with (4) ½”
fasteners (not
provided). Secure
the 2-3/8”slipfitter to
the FRWB by
tightening set
screws.
Description: Steel Angle Mounting Bracket
(FSAB)
(n/a TV)
Installation: Secure the FWPB to surface with (1) 7/16” fastener and
(2) ½” fasteners (not provided). Secure the yoke to the FWPB by
using the 5/8” bolt, lockwasher, and nut provided.
Installation:
Secure the EWB
to surface with 4,
½” fasteners (not
provided). Secure
the yoke to the
EWB by using a
3/8” bolt,
lockwasher, and
nut (not provided).
Description: Extended Wall Bracket
(EWB)
(n/a TV)
Note: Due to yoke design, the TFM will be off-center.
Description: Radius Wall Mounting Bracket
(FRWB)
Description: Wall Pipe Mounting Bracket
(FWPB)
(n/a TV)
Note: Due to yoke design, the TFM will be off-center.Note: Due to yoke design, the TFM will be off-center.
Installation: Secure the FSAB to surface with 5/8”
fastener and (2) ½” lag bolts (not provided). Secure the
yoke to the
FSAB by
using the
bolt,
lockwasher,
and nut
provided.
3-3/4”
7”
13”
9/16”
12”
5-11/16”
13”
9/16
7”
7”
12”
DISCONTINUED
Installation Instructions
Part Number: RJ52100263
Revision Date: REV A 1/11/10
Lithonia Lighting Outdoor
One Lithonia Way, Conyers, GA 30012
Phone: 800-279-8041 Fax: 770-918-1209
www.lithonia.com
BRACKETS MUST NOT BE INVERTED.
(Drawings are not to scale, should be used for dimensional
purposes only, and are subject to change without notice)
Outdoor Floodlighting Mounting Brackets
Installation: Secure to desired
horizontal surface with 4, 1/2”
fasteners (by others). Secure the
knuckle to the stanchion by
tightening the provided (2)
locknuts onto the
1/2” nipple via the wire access
cover.
Description: Wall mount arm for 1/2” knuckle option
(KFLWMATHK)
Installation: Secure the
tenon mounting plate to the
desired horizontal surface
with four, 1/2” fasteners
(provided by others). Secure
the 2-3/8” swivel mount to
the STM by tightening set
screws.
Base Plate: 8" x 8"
Installation: Secure the
mounting plate with 4, 3/8”
fasteners (by others).
Secure the knuckle to the
arm by tightening the
provided (2) locknuts onto
the 1/2” nipple via the end
cap.
(Base plate:
7 1/8” x 4” x 3/16”)
Description: Stanchion mount for 1/2” knuckle option
(KFLSTMTHK)
Mtg hole detail: 6" x 6"
Installation: Secure the bar to 2-3/8” tenon by tightening the 4 set
screws included. Secure the fixture knuckle to the bar by tighten-
ing the provided (4) locknuts onto the (2) 1/2” nipples via the end
caps.
Description: Twin mounting bar for 1/2” knuckle option
(KFLTMBTHK)
Description: Architectural J-box for 1/2” knuckle option.
(AJB)
Installation: Attach to
1/2” conduit. Secure the
knuckle to the AJB by
tightening the provided
(2) locknuts onto the
1/2” nipple via the
handhole cover.
Description: Stanchion Mount
(STM)
Bottom View
©2001 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 1/10
DISCONTINUED
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Lithonia Lighting TFA Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI