Output Type Description
Address
—— Source address of the PVED-CLS.
Timeout ms Maximum time in ms between messages before a timeout fault is triggered.
Msg Timed Out T/F
True if the time since the last status message has exceeded the value determined by Timeout.
T: The message has timed out, block outputs set to zero/false. NA signals set true.
F: No error.
No Msg Rcv T/F
No message has been received yet from the device.
T: No message received since power on.
F: A message has been received since power on.
Joy Pos 1
%
Measured joystick position 1.
-100% corresponds to the left most position.
0% corresponds to the neutral position.
100% corresponds to the right most position.
Joy Pos 2
% Measured Joystick position 2.
-100% corresponds to the left most position.
0% corresponds to the neutral position.
100% corresponds to the right most position.
Joy Flow Rqst
% Joystick flow request.
Negative values correspond to maximum flow to the left.
0% corresponds to the neutral position.
Positive values correspond to maximum flow to the right.
IEC 61508-3 Annex D Supplemental Information
The following table provides IEC 61508-3 Annex D supplemental information.
Label Description
Software Name PVED_CLS_STAT_MSG_7
Software Version 1.00
Release Status Released.
Required Knowledge
Requirements to the user:
1. The programmer must fully read and understand all parts of the Safety Manual
before attempting to use the software product.
2. The programmer must have well-founded knowledge about using PLUS+1
®
tools.
3. The programmer must fully read and understand all parts of the PVED-CLS User
Manual before attempting to use the software product.
Revision History
Version 1.00.
First release.
Known Issues Not applicable.
Backward Compatibility
——
Market Requirements Not
Met
——
Change Request Direct any change request to your Danfoss sales representative.
Support Direct any request to the PLUS+1
®
help desk:
OS The software is not hardware specific.
Tool Requirements PLUS+1
®
GUIDE version 9.1 or later certified version.
PLUS+1
®
Service Tool version 9.1 or later certified version.
Security Not applicable.
Design Level
•
All software development has been done using SIL2 processes.
•
The hardware library is not SIL2 certified.
•
Danfoss provides required documentation to certifying bodies on customer request.
Certification Not certified.
User Manual
PLUS+1® Compliant PVED_CLS_STAT_MSG_7 Function Block
PVED_CLS_STAT_MSG_7 Function Block