DATE: April 30, 2003 BULLETIN NO: M-03-009
!!!!! WARNING !!!!!
Immediate Action Required
TITLE/ PRODUCT NAME: ESAB 653 cvcc Power Source
RATING:
_
X_ DIRECTIVE _X_ ALERT
(Action is Required) (Potential Problem)
_
_ INFORMATION _ _ PRODUCT IMPROVEMENT
(Action is Optional) (Enhanced Product)
_X_ General Distribution _ _ Business Confidential
(Unrestricted) (Restricted Distribution)
PRODUCT SERIES/ MODEL:
Part Number Description
37829 653 cvcc 230/460 Vac
37834 653 cvcc 230/460/575 Vac
37830 653 cvcc 230/460/575 Vac (CSA)
37835 653 cvcc 230/460/575 Vac (CSA - Environmental)
37832 653 cvcc 220/400 Vac 50 Hz.
37831 653 cvcc 220/400 Vac 50 Hz. (CE)
37836 653 cvcc 220/400 Vac 50 Hz. (CE - Environmental)
37921 653 cvcc 230/460/575 Vac (OEM)
37922 653 cvcc 220/400 Vac 50 Hz. (CE - OEM)
SERIAL NO:
All serial numbers for the above units
SUMMARY:
ESAB has determined that a potential condition exists with the referenced power sources which could,
with improper operator set-up, lead to a serious safety issue. Inadequate clearance between certain
primary and secondary components may cause shorting of the primary voltage to the welding output of
the power source. If the work piece is not properly earth grounded as required, a potentially serious
hazard could exist that could lead to personal injury or death or other equipment damage. Immediate
inspection is required:
DISCONNECT primary power at wall switch, or circuit breaker,
before attempting inspection or work inside the power source.
1. Remove the power source top cover and right side panel.
2. Inspect the wiring on the rear of the voltage link board for wire contact with the transformer bus
bar as shown below. See Corrective Action below.
3. Inspect the opposite end of the transformer bus bar for primary wire routing that is in contact
with the bus bar as indicated below. See Corrective Action below.
OPERATIONAL IMPACT:
If this condition exists, it may not be apparent to the weld operator in the everyday operation of the
power source. Only a visual inspection and corrective action can eliminate the potential hazard
before a more serious unsafe condition develops.
All work should be completed by a
qualified electrical technician
CORRECTIVE ACTION:
1. Move wires so they are not in contact with the transformer bus bar and have at least 1”
separation from all un-insulated metal surfaces.
2. Order and install, free of charge
, the “Bus Bar Insulator” kit PN-0558004248.
3. Further Technical assistance and service will be provided by ESAB free of charge through the
following contact:
ESAB Welding & Cutting Products
Product & Service Information Group
843-664-4416