DKS 1601 - Wood Arm Folding Kit User manual

Type
User manual
Note: Completed folding arm
assembly shown in the UP position
to illustrate the total height.
WOOD FOLDING ARM KIT
Installation
DoorKing Part Number
1601-384
This kit is designed for the 1600 model barrier gate operators only. Recommended for low headroom applications.
Kit Includes:
Cut this arm
first for the
height
limitations.
Determining First Arm Length
Cut this arm second for the
traffic lane width.
Note: Second arm can be a
different size than the first.
Determining Second Arm Length
Cut Arms to Length
Total Length 132” (Typical)
Total Height 103” (Typical)
Pre-Crimped Eyelet
Cable Attachment Assembly
Cable
2 Wood Arms
Cable Clamp
2 Hinge Plates
Cable Eyelet
Locking Turnbuckle
1
2
4 Bolts with
Locknuts (Small)
Bolt with Bushing
and Locknut (Medium)
Bolt with Brass Bushing
and Locknut (Large)
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
3/4”
33”
Typical
96 3/8”
Typical
Note: Completed folding arm
assembly will be 12 ft in
length when using typical
measurements.
Note: Completed folding arm assembly
shown in the DOWN position to illustrate
the total length.
1601-267-E-4-18
DoorKing Part Number
1601-384
Copyright 2018 DoorKing, Inc. All rights reserved.
Top View of
Operator Housing
Hub
Existing Stud
Adjusting and Locking Cable Assembly
After adjusting cable tension, lock turnbuckle with nuts in position shown to prevent
turnbuckle from rubbing against hinge plates when the arm is in the UP position.
Rotate arm up and down. Adjust cable tension with turnbuckle
to level outer arm. Make sure that cable assembly is not binding
or twisting and everything moves freely.
Inner Arm
Outer Arm
Outer Arm
1
3A
2A
3A
Install inner arm on hub.
2
Install hinge plates.
3
Install cable. Cable MUST clear hub!
Remove stud from operator housing
and assemble as shown.
Bushing
Operator Housing
Adjust to clear hub.
Pre-Crimped Eyelet
Bolt Head (Inside Housing)
Washer (Inside Housing)
Locknut
Installing Arms
Installing Cable
Attachment Assembly
Side View of
Operator Housing
Cable Eyelet MUST be installed in turnbuckle.
Cable Clamp
Allow turnbuckle to
loosen or tighten.
Cut off excess cable.
Bushing
Turnbuckle
Bolt (Medium)
Bolt (Large)
4 Bolts (Small)
Brass
Bushing
Installing Hinge Plates
Locknut
Locknut
4 Locknuts
2A
Outer Arm
Inner Arm
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
B
A
B
A
Important Notes:
“As should be the same lengths, “Bs should be the same heights,
BEFORE adjusting turnbuckle.
DO NOT adjust cable too tight or it will bind.