1601-266-D-4-18
DoorKing Part Number
1601-383
Copyright 2018 DoorKing, Inc. All rights reserved.
Top View of
Operator Housing
Side View of
Operator Housing
Hub
Existing Stud
Adjusting and Locking Cable Assembly
After adjusting cable tension, lock turnbuckle
with nuts to keep turnbuckle from twisting.
Lock eye bolt with nut to
keep eye bolt from twisting.
Inner Arm
Outer Arm
Cable Eyelet MUST be installed in turnbuckle.
Cable Clamp
Install eye bolt into arm
hinge with vise-grips.
Attach arm hinge to
inner arm with 4
self-tapping screws.
1
2
3A
3A
Allow turnbuckle to
loosen or tighten.
Install inner arm
on hub.
3
4
Install cable. Cable MUST clear hub!
Cut off excess cable.
Remove stud from operator housing
and assemble as shown.
Bushing
Operator Housing
Adjust to clear hub.
Pre-Crimped Eyelet
Bolt Head (Inside Housing)
Washer (Inside Housing)
Locknut
Install outer arm
with 4 self-tapping
screws.
Installing Arms
120 S. Glasgow Avenue
Inglewood, California 90301
U.S.A.
Rotate arm up and down. Adjust cable tension with turnbuckle
to level outer arm. Make sure that cable assembly is not binding
or twisting and everything moves freely.
Important Notes:
“As” should be the same lengths, “Bs” should be the same heights,
BEFORE adjusting turnbuckle.
DO NOT adjust cable too tight or it will bind.
B
A
B
A