Quick Start Guide
for the BCM95389/BCM95396
Reference Board
04/29/05
Broadcom
®
, the pulse logo, Connecting everything
®
, and the Connecting everything logo are among the trademarks of
Broadcom Corporation and/or its affiliates in the United States, certain other countries and/or the EU. Any other
trademarks or trade names mentioned are the property of their respective owners.
Broadcom Corporation
P.O. Box 57013
16215 Alton Parkway
Irvine, CA 92619-7013
© 2005 by Broadcom Corporation
All rights reserved
Printed in the U.S.A.
REVISION HISTORY
Revision Date Change Description
95389_95396-QS100-R 04/29/05 Initial release.
Broadcom Corporation
Document 95389_95396-QS100-R Page iii
TABLE OF CONTENTS
Overview ..........................................................................................................1
Block Diagram ................................................................................................2
Connector Settings .........................................................................................3
Setting Up a WebSmart™ Console Connection .......................................4
Terminal-to-WebSmart™ Connection .................................................4
Configuring the HyperTerminal Utility ................................................5
Setting Up a WebSmart™ Web-Based Connection ..................................8
BCM95389/BCM95396
Broadcom Corporation
Page iv Document 95389_95396-QS100-R
Broadcom Corporation
Document 95389_95396-QS100-R Page v
LIST OF FIGURES
1: BCM95389 Block Diagram...............................................................................2
2: BCM95396 Block Diagram...............................................................................2
3: Terminal-to-WebSmart Connection................................................................4
4: WebSmart Web-Based Connection.................................................................8
Broadcom Corporation
Document 95389_95396-QS100-R Page vi
LIST OF TABLES
Table 1: BCM95389 Connector Settings ............................................................3
Table 2: BCM95396 Connector Settings ............................................................3
BCM95389/BCM95396 Overview
Broadcom Corporation
Document 95389_95396-QS100-R Page 1
Overview
This document discusses how to bring up the Broadcom BCM95389/
BCM95396 reference board system using WebSmart™ software. It describes
steps required to set up and configure the WebSmart program.
The WebSmart program allows you to manage the Broadcom BCM95389/
BCM95396 reference board and monitor its performance. This program can
be accessed by either of the following:
A direct connection between a management console and the console port
of the Broadcom BCM95389/BCM95396 reference board. The
management console used for the connection can be a VT-100 terminal or
PC-running terminal emulation software. The user has access to the
WebSmart common language infrastructure (CLI).
A network connection from one of the ports of the BCM95389/
BCM95396 reference board to a client Web browser. The user has access
to the WebSmart web-based GUI interface.
BCM95389/BCM95396
Broadcom Corporation
Page 2 Document 95389_95396-QS100-R
Block Diagram
Figure 1 and Figure 2 are generalized block diagrams for the BCM95389 and
BCM95396 reference boards.
Figure 1: BCM95389 Block Diagram
Figure 2: BCM95396 Block Diagram
Magnetics Magnetics
BCM5464 BCM5464
J1
J2
J4
U12
J3
BCM5389
BCM5464
5396
Magnetics Magnetics
Magnetics
Magnetics
BCM5464 BCM5464 BCM5464
Taifatech
TF
J31
J32
J16
J28
J29
J30
J34
J33
SW2
U46
U47
SK2
SK3
J10
U11 U15 U19 U23
J12
J14
SK6
SK5
SK4
BCM95389/BCM95396 Connector Settings
Broadcom Corporation
Document 95389_95396-QS100-R Page 3
Connector Settings
Table 1: BCM95389 Connector Settings
Number Settings
J2 CPU_EPROM_SEL strap pin setting.
1–2: SPI Mode
2–3: EEPROM mode
J3 Mux components connecting to SPI/EEPROM pins.
1–2: EEPROM (U12)/ 6-pin jumper (J4)
2–3: Microcontroller (U7)
Power
Connector
5V/300A DC power source
Table 2: BCM95396 Connector Settings
Number Settings
J10 SPI header/6-pins
OPEN: For Websmart/microcontroller (8051) mode
CLOSE: For SPI mode
J12 CPU_EPROM_SEL strap pin setting.
OPEN: For SPI mode
CLOSE: For EEPROM mode
J14 OPEN: For nonmanagement mode
CLOSE: For management mode
J16 Mux components connecting to SPI/EEPROM pins.
1–2: 8051 mode
2–3: Websmart mode
J28 Mux components connecting to SPI/EEPROM pins.
1–2: 8051 mode
2–3: Websmart mode
J29 Mux components connecting to SPI/EEPROM pins.
1–2: 8051 mode
2–3: websmart mode
J30 Mux components connecting to SPI/EEPROM pins.
1–2: 8051 mode
2–3: websmart mode
J31 UART
1–2: 8051 mode
2–3: websmart mode
J32 UART
1–2: 8051 mode
2–3: Websmart mode
BCM95389/BCM95396
Broadcom Corporation
Page 4 Document 95389_95396-QS100-R
Setting Up a WebSmart™ Console Connection
Terminal-to-WebSmart Connection
Connect a terminal or a PC with terminal emulation software to the console
port using a RS-232 straight cable.
Figure 3: Terminal-to-WebSmart Connection
Note:
The console port on the demo system is a DB-9 connector.
J33 Mux components connecting to SPI/EEPROM pins.
1–2: 8051 mode
2–3: Websmart mode
J34 Mux components connecting to SPI/EEPROM pins.
1–2: 8051 mode
2–3: Websmart mode
J13 AL-A250ATX MAX250W power source
Table 2: BCM95396 Connector Settings (Continued)
Number Settings
RS-232 Cable
9-pin Female
Connector
9-pin Male
Connector
9-pin Female to
9-pin Male Cable
Broadcom Switch
BCM95389/BCM95396 Setting Up a WebSmart™ Console Connection
Broadcom Corporation
Document 95389_95396-QS100-R Page 5
Configuring the HyperTerminal Utility
HyperTerminal is a Windows
®
utility program for serial communications.
To configure HyperTerminal, follow these steps:
1. Start the HyperTerminal utility.
2. Select the COM port to communicate with the BCM95389/BCM95396
demo target board.
3. Set the serial port properties:
Bits per second: 19200 bps
Data bits: 8 bits
Parity: none
Stop bits: 1
Flow control: none
The properties window should look like the window below.
4. Click OK.
BCM95389/BCM95396
Broadcom Corporation
Page 6 Document 95389_95396-QS100-R
5. From the Properties menu select the Settings tab.
6. Click the ASCII Setup button to display the ASCII Setup window.
7. Click OK.
8. Power up in the BCM95389/BCM95396 reference board. If
communication is successful, the WebSmart CLI prompt appears on the
screen as shown below:
BCM95389/BCM95396 Setting Up a WebSmart™ Console Connection
Broadcom Corporation
Document 95389_95396-QS100-R Page 7
9. The BCM95389/BCM95396 WebSmart CLI prompts can be viewed by
typing h for Help Menu. Typing <enter> afterward is not necessary.
10. The initial network setting can be viewed by typing ng. Typing <enter>
afterward is not necessary. The display appears as shown below:
11. To customize these settings, type ns at the prompt. Typing <enter>
afterward is not necessary. Typing ns prompts asking if DHCP is preferred.
Type y for yes or n for no. If no is chosen, the next message shows the
existing IP address. This address can be modified by backspacing and typing
the new IP address. Type <enter> when finished. The same procedures
apply for changing the netmask and gateway. See the example below:
BCM95389/BCM95396
Broadcom Corporation
Page 8 Document 95389_95396-QS100-R
Setting Up a WebSmart™ Web-Based Connection
Connect both the client station and the BCM95389/BCM95396 reference
board to a common network. The BCM95389/BCM95396 reference board
connects via one of its network ports.
Figure 4: WebSmart Web-Based Connection
Note:
The BCM95389/BCM95396 reference board should have a
jumper connecting pins 2 and 3 on the J3 connector. This jumper should
be installed by default. If not, or if it has been changed, this jumper must
be replaced on pins 2 and 3 for the Web-based WebSmart software to
operate.
1. Power-up the BCM95389/BCM95396 reference board.
2. Open the Web browser software on the client system.
Switch RJ-45
Port
Client System Network
Broadcom Switch
BCM95389/BCM95396 Setting Up a WebSmart™ Web-Based Connection
Broadcom Corporation
Document 95389_95396-QS100-R Page 9
3. Type the IP address corresponding to the BCM95389/BCM95396
reference board. If the address has not been changed either manually (by
issuing the ns command) or by the DHCP, the default address is
192.168.0.234. The browser address box should then be http://
192.168.0.234.
4. A dialog box should appear. Type admin for the username and admin for
the password as shown below.
5. The main menu Web-based WebSmart page should look similar to the
window below.
BCM95389/BCM95396
Document 95389_95396-QS100-R
Broadcom Corporation
16215 Alton Parkway
P.O. Box 57013
Irvine, CA 92619-7013
Phone: 949-450-8700
Fax: 949-450-8710
Broadcom
®
Corporation reserves the right to make changes without further notice to any products or data herein to improve reliability, function, or design.
Information furnished by Broadcom Corporation is believed to be accurate and reliable. However, Broadcom Corporation
does not assume any liability arising out of the application or use of this information, nor the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Broadcom BCM95389 Quick start guide

Type
Quick start guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI