Minka Group 5198-697 User manual

Type
User manual
INSTALLATION INSTRUCTIONS
Item#5198-697(Convertible Lamps for Pendant) (New. 2023/06/10)
READ AND SAVE THESE INSTRUCTIONS
W A R N I N G ! S H U T P O W E R O F F AT F U S E O R C I R C U I T B R E A K E R .
p
Page: 1/2
Fig. 1
Fig. 2
LA-3686E
PREPARATION
(Fig. 1)
1. Shut off power at the fuse box or circuit breaker box and remove
the old fixture including the mounting hardware.
2. Carefully unpack your new fixture and lay out all the parts in a
clean area. Take care not to misplace any small parts necessary
for installation.
3. Put plastic washers (K), large glass balls (J), plastic washers (K)
through the longer rods on assembly (M), than secure with nut
(L). Put plastic washers (K), small glass balls (J1), plastic
washers (K) through the shorter rod on assembly (M), than
secure with nut (L).
4. Thread metal ring (I) onto all thread (G), then thread assembly
(M) onto all thread (G) on top of fixture body.
5. Determine the desired hanging height and thread rods (F1, F2
and F3) to all thread on assembly (M). Screw canopy (C) onto
rod (F1). Carefully pass the wires through each rod during
assembly.
6. Position mounting plate (A) on ceiling and mark location of the
three drywall anchors (E). Pre-drill holes for drywall anchors (E).
Then insert drywall anchors (E) into ceiling.
7. Attach mounting plate (A) to junction box (not included) with
mounting screws (B) (Size: #8-32N*L0.5”) and wood screws (H)
into drywall anchors (E). The side of mounting plate marked
“GND” must face out.
8. The support cable is provided to support weight of the fixture
while wiring. Align fixture to mounting plate (A) and attach hook
(P1) on the end of support cable (R) to a slot located on
mounting plate (A). Carefully allow support cable (R) to support
weight of fixture while wiring.
CONNECTING THE WIRES (Fig. 4)
9. Connect the electrical wires as shown in figure 4, making sure
that all wire connectors are secured. If your junction box has a
ground wire (green or bare copper), connect the fixture’s ground
wire to it. Otherwise, connect the fixture’s ground wire directly to
mounting plate (A) using the green screw provided.
10. Tuck wire connectors neatly into the junction box.
COMPLETING THE INSTALLATION (Fig. 1& Fig. 2)
11. Place canopy (C) over mounting plate (A) and secure with
screws (D).
12. Install (8) eight candelabra base bulbs (Q) up to 60 watts each or
CFL or LED equivalent (not included) in accordance with the
fixture specification. DO NOT EXCEED THE MAXIMUM
WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE
NOMINALE MAXIMALE!)
13. Hang decorative glass balls (Z) to first ring (T1). Hang decorative
glass balls (X) to second ring (T2). Hang decorative glass balls
(Y) to third ring (T3). Hang decorative glass balls (O) to the
fourth ring (T4). Hang decorative glass ball (N) to the bottom of
housing, as shown (Fig.2).
Your installation is now complete. Return power to the junction
box and test the fixture.
Note: Illustration (Fig. 1& Fig. 2) on this manual is for
installation purposes only. It may or may not be identical to
the fixture purchased.
Set# A-021-162D
-Circular Strap
-Ground Screw
-Mounting Screw*2
Rod# W30-1-697*1(F1)
W30-1-697*2(F2)
W30-H-697*1(F3)
G
M
K
K
L
K
T3
T2
T1
T4
F2
F1
F3
A
B
H
D
R
C
E
J
J1
J
J1
J1
L
K
Q
Z
X
Y
O
N
P1
155MM
D3.5 Inch
95 MM
D3.5 Inch
100 MM
D4.75 Inch
Z Qty: 10Pcs
48 MM
D4.75 Inch
X Qty: 10Pcs
Y Qty: 5Pcs
95 MM
D4.75 Inch
O Qty: 5Pcs
N Qty: 1Pc
Z *10 pcs
X *10 pcs
Y *5 pcs
O *5 pcs
N *1 pc
T1
T2
T3
T4
INSTALLATION INSTRUCTIONS
Item#5198-697 (Convertible Lamps for Semi Flush Mount) (New. 2023/06/10)
READ AND SAVE THESE INSTRUCTIONS
W A R N I N G ! S H U T P O W E R O F F AT F U S E O R C I R C U I T B R E A K E R .
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
Page: 2/2
Fig. 3
Fig. 5
Fig. 4
PREPARATION
(Fig.
3
&
Fig.5
)
1. Loosen hex nut (S) by using wrench (W) (not included)
.
Carefully remove washer (T), lock washer (U), L-
shaped
metal plate (V), canopy (C) and swivel (P) (Fig.5).
2. Put plastic washers (K), large glass balls (J),
plastic
washers (K) through the longer rods on assembly (M),
than secure with nut (L). Put plastic washers (K), small
glass balls (J1), plastic washers (K) through the short
er
rod on assembly (M), than secure with nut (L).
3. Thread metal ring (I) onto all thread (G), then thread
assembly (M) onto all thread (G) on top of fixture body.
4. Thread canopy (C), L-shaped metal plate (V), lock washer
(U), washer (T), and hex nut (S) into all thread
on rod
(M). Then secure hex nut (S) using wrench (W) (not
included). (Fig. 3). Cut wire leaving 7” for installation.
5. Position mounting plate (A) on ceiling and mark location of
the three drywall anchors (E). Pre-
drill holes for drywall
anchors (E). Then insert drywall anchors (E) into ceiling.
6. Attach mounting plate (A) to junction box (not included)
with mounting screws (B) (Size: #8-
32N*L0.5”) and wood
screws (H) into drywall anchors (E). The side of mounting
plate marked “GND” must face out.
7. The support cable is provided to support weight of the
fixture while wiring. Align fixture to mounting plate (A) and
attach hook (
P1) on the end of support cable (R) to a slot
located on mounting plate (A). Carefully allow support
cable (R) to support weight of fixture while wiring.
CONNECTING THE WIRES (Fig. 4)
8. Connect the electrical wires as shown in figure 4, making
sure that all wire connectors are secured.
If your junction
box has a ground wire (green or bare copper), connect the
fixture’s ground wire to it. Otherwise, connect the fixture’s
ground wire directly to
mounting plate (A) using the green
screw provided.
9. Tuck wire connectors neatly into the junction box.
COMPLETING THE INSTALLATION (Fig. 3 & Fig. 2)
10.
Place canopy (C) over mounting plate (A) and secure
with screws (D).
11. Install (8) eight candelabra base bulbs (Q) up to 60 watts
each or CFL or LED equivalent (not included) in
accordance with the fixture specification. —DO NOT
EXCEED THE MAXIMU
M WATTAGE RATING! (NE PAS
DEPASSER LA PUISSANCE NOMINALE MAXIMALE!)
12. Hang decorative
glass balls (Z) to first ring (T1). Hang
decorative
glass balls (X) to second ring (T2). Hang
decorative
glass balls (Y) to third ring (T3). Hang
decorative glass balls (O)
to the fourth ring (T4). Hang
decorative glass ball (N) to the bottom of housing, as
shown (Fig.2).
Your installation is now complete. Return power to the junction
box and test the fixture.
Note: Illustration (Fig. 3
) on this manual is for installation
purposes only. It may or may not be identical to the fixture
purchased.
Set# A-021-162D
-Circular Strap
-Ground Screw
-Mounting Screw*2
LA-3686E
T3
T2
T1
T4
W
S
U
T
C
J
J1
J
J1
J1
L
K
Q
Z
X
Y
O
N
I
G
M
K
K
L
K
P1
A
B
H
D
V
E
R
S
T
U
W
C
V
P
FIXTURE
WIRES
Black or
Smooth
HOUSE
WIRES
Black
(Hot)
FIXTURE
WIRES
White or
Ribbed
HOUSE
WIRES
White
(Neutral)
FIXTURE
WIRES
Bare
Copper
(Ground)
HOUSE
WIRES
Green
(Ground)