American Dynamics Excalibur SE Installation & Setup Instructions Manual

Type
Installation & Setup Instructions Manual
Installation and Setup Instructions
This manual describes the installation and setup procedures for the American Dynamics Excalibur SE Graphical Security
Workstation. Excalibur SE (System Edition) is provided with American Dynamics CCTV Matrix Switching Systems as a
graphical interface for the control and monitoring of security areas under surveillance of the CCTV system. This manual
provides the Excalibur SE installation and setup procedures only. Refer to the Excalibur SE Operating Instructions Manual,
OP5400A, for the operating procedures of the Excalibur SE system.
Excalibur SE (System Edition)
Graphical Security Workstation
The software/firmware furnished for this equipment is confidential to and is copyrighted by AMERICAN DYNAMICS or others.
It is not to be copied or disclosed in any manner without the express written consent of AMERICAN DYNAMICS. The
software/firmware is furnished to the purchaser under a license for use on a single system. See the Appendix of this manual for a
copy of the license agreement.
Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable. However, no responsibility is
assumed by AMERICAN DYNAMICS for its use; nor for any infringements of other rights of third parties which may result
from its use. No license is granted by implications or otherwise under any patent or patent rights of AMERICAN DYNAMICS.
Note: IBM and PC-DOS are registered trademarks of the International Business Machines Corporation. MS-DOS and Windows
are registered trademarks of the Microsoft Corporation. AD is a registered trademark of American Dynamics Corporation.
Table of Contents
Page
System Description ............................................................................... 1
Features ................................................................................................. 1
INSTALLATION............................................................................... 1-1
System Installation ...................................................................... 1-2
Software Installation.................................................................... 1-4
Excalibur SE Windows................................................................ 1-5
Excalibur SE Setup...................................................................... 1-5
EXCALIBUR SE SYSTEM SETUP PROGRAM ........................... 2-1
Excalibur SE System Setup Menus
Set Directory.......................................................................... 2-3
Set Ports................................................................................. 2-4
Operators ............................................................................... 2-6
Maps ...................................................................................... 2-7
Sound Files............................................................................ 2-8
EXCALIBUR CAD PROGRAM ...................................................... 3-1
Excalibur CAD Menus
File......................................................................................... 3-3
Draw ..................................................................................... 3-4
Text ....................................................................................... 3-6
Style....................................................................................... 3-6
Fill.......................................................................................... 3-7
Color...................................................................................... 3-7
Edit......................................................................................... 3-7
Icons....................................................................................... 3-8
Options................................................................................... 3-9
Image................................................................................... 3-10
Description........................................................................... 3-11
Excalibur CAD Window Buttons .............................................. 3-11
Editing Objects.......................................................................... 3-12
Exiting Excalibur CAD Program............................................... 3-13
EXCALIBUR SE ICON SETUP PROGRAM.................................. 4-1
Deleting Icons.............................................................................. 4-2
Cameras....................................................................................... 4-3
VCR/Quads.................................................................................. 4-4
Maps ......................................................................................... 4-4
Exiting Excalibur SE Icon Setup................................................. 4-4
APPENDIX
Complete Excalibur version 2.0 Capabilities ............................. A-1
Feature Comparison Table.......................................................... A-2
Security Resource Icons ............................................................. A-3
Excalibur Data Files ................................................................... A-4
License Agreement ................................................ Inside rear cover
SYSTEM DESCRIPTION
The Excalibur SE (System Edition) Graphical Security
Workstation provides a user-friendly operator interface for
monitoring activity at security areas under surveillance of
American Dynamics CCTV Matrix Switching Systems. The
Excalibur SE system allows the user to define surveillance
areas to be observed and to provide user-selected icons or
symbols representing the key security resources at the
surveillance area. Any security area defined by this system
may be manually called up to the workstation screen for
operator viewing.
The Excalibur SE system operates in conjunction with a
Matrix Switching System (such as the 1650B, 2050, 2052WIP,
2150, and 2350) to identify and monitor all cameras
established in the switching system. The Excalibur SE system
does not replace the security setup and programming
capabilities of the Matrix Switching System, but provides a
user-friendly operator interface that operates with the system
Controller or CPU and enhances the operation of a Matrix
Switching System.
The Excalibur SE graphical user interface software combines a
variety of features with the advanced features incorporated into
American Dynamics Matrix Switchers. By having several
setup options within Excalibur SE and many options available
with the Matrix Switchers, it is possible to configure a system
with a wide variety of features and modes.
FEATURES
The Excalibur SE (System Edition) Graphical Security
Workstation provides the following features:
Menu-driven operation with mouse, touch-screen, and
keyboard control
User-defined surveillance area Maps
User selection of security resources Icons
High resolution color display of security areas
Manual callup of any surveillance area or resource
Full remote control of auxiliary and camera pan/tilt
Menu selection of pre-programmed System Salvos and
Tours
Full on-screen AD keyboard emulation
Operator password protection and operation access levels
The Excalibur SE (System Edition) is provided with AD
Matrix Switching Systems. Several functions and options of
the setup menus cannot be selected from this version - these
are indicated in the appropriate paragraphs of this manual. The
added features and capabilities of the complete Excalibur
version 2.0 are identified in the Appendix, page A-1.
1
SYSTEM DESCRIPTION and FEATURES
EXCALIBUR
Figure 1 - Excalibur SE Graphical Security Workstation
Excalibur SE
Installation
This section of the manual describes the installation procedures for the
American Dynamics Excalibur SE Graphical Security Workstation.
Excalibur SE programs operate on an IBM-compatible Personal Computer
(PC), under the Windows operating system.
SYSTEM INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
PC Configuration Requirements . . . . . . . . . . . . . . . . . . . 1-2
PC RS-232 Communications Ports . . . . . . . . . . . . . . . . . 1-2
PC Printer Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
SOFTWARE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . 1-4
Directories and Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Installing Excalibur SE Programs . . . . . . . . . . . . . . . . . . 1-4
EXCALIBUR WINDOWS . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Dialog Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
EXCALIBUR SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
INITIAL STARTUP NOTE . . . . . . . . . . . . . . . . . . . . . . 1-5
1-1
SYSTEM INSTALLATION
Because the features of Excalibur SE and the Matrix Switching
System are so versatile, it is important to plan the installation
carefully to gain full advantage of these features. It is
recommended that the user become thoroughly familiar with
the capabilities and operating modes of the Matrix Switcher,
determine the needs of the facility, and set up the Excalibur SE
system only after thorough planning.
The weakest links in any security/CCTV system using
Excalibur SE will be the computer hardware and the quality of
the CCTV system installation. It is strongly recommended that
a computer of the highest quality and reliability is used. An
uninterruptible power supply is required (UPS), as opposed to
a standby power supply (SPS) which is sometimes billed as a
true UPS. The software is designed to reload critical data at
regular intervals to help avoid memory corruption problems
from power surges, glitches, and momentary outages.
However, it is still essential to use computer hardware of the
highest quality, to use a UPS to control and condition the
power, and to provide a stable power circuit to insure reliable
control and monitoring.
PC Configuration Requirements
The minimum computer configuration required to operate the
Excalibur SE program system is a true IBM PC compatible
computer, with the following:
1. At least a 386DX 33 Mhz or 486SX 25 Mhz processor.
2. A minimum of 4 Mbytes of RAM extended memory. The
number of maps and icons available is directly related to the
amount of RAM; a minimum of 4 Mb is recommended.
3. A minimum hard disc capacity of 100 Mbytes.
4. A two-button mouse or mouse emulating input. It is not
possible to use the Excalibur SE program without a mouse
or mouse emulating input device.
5. Windows 3.1 Operating Software; DOS 5.0 or greater.
6. A Windows compatible sound card to annunciate operator
actions (optional).
PC RS-232 Communications Ports
For proper RS-232 communication with the Excalibur SE
workstation PC, the pin definition and the DTE (Data Terminal
Equipment) or DCE (Data Control Equipment) configuration
of each connected device must be observed. All American
Dynamics equipment, including Matrix Switching System
Controllers, are configured as DTE devices.
For DTE-to-DTE communications between a Matrix Switching
System Controller and the Excalibur SE workstation PC,
connect a three-wire, shielded, 18-AWG RS-232 cable from
the Excalibur SE workstation PC RS-232 port to a Matrix
Switching System Controller RS-232 port, as follows:
a. Connect GND from the Excalibur SE PC port to GND on
the controller's RS-232 port.
b. Connect RCD from the Excalibur SE PC port to XMIT
on the controller's RS-232 port.
c. Connect XMIT from the Excalibur SE PC port to RCD
on the controller's RS-232 port.
Refer to the RS-232 port connector pin definitions and setup
instructions in the appropriate Switching System Controller
Installation Manual.
PC Printer Port
The 25-pin HASP plug supplied with the Excalibur SE
software must be connected to the PC printer port, LPT1.
Figure 1-1, page 1-3, illustrates a typical Excalibur SE
workstation PC configuration.
INSTALLATION
1-2
1-3
INSTALLATION
Com1
Com2
EXCALIBUR PC
Rear Panel Connectors
LPT1
HASP Plug
Mouse
Matrix Switching
System Controller
Figure 1-1 - Excalibur SE PC Configuration
SOFTWARE INSTALLATION
The Excalibur SE software operates under Windows. For
proper operation under Windows, Excalibur SE requires
several system setup options. Refer to the Windows Operating
Manual for instructions on setting these modes and options.
1. Windows must be set to run in Enhanced mode.
2. The SMART.DRV device driver supplied with Windows
must be set up with a cache of at least 1 Mbyte.
3. The CONFIG.SYS startup file must be configured so that
the system uses extended memory only — NO EMS
(expanded memory).
Directories and Files
The Excalibur SE program system uses DOS directories for
program files and for setup data files. Each of these is created
during the setup procedure.
The Excalibur SE program files must all reside in the same
directory. If they are not, the programs will not execute. This
directory is defined, and created if it does not exist, during
installation of the Excalibur SE system programs. The default
directory is named “EXCAL_SE”. If another directory name
is desired, it may be entered when prompted during Excalibur
SE program installation (next section).
The Excalibur SE setup data files (e.g. the .MAP, .ICN, .SDB
files) must also reside in a single directory. The Excalibur SE
installation program creates a default data directory “DATA”
under the program file directory. At the users option, data files
may be located in any subdirectory by moving the DATA
directory or creating a new one using standard DOS/Windows
file management procedures. The data file directory need not
be on the same drive as the program files. (It may be defined
on a network drive to be shared with other workstations.)
Installing Excalibur SE programs
To install Excalibur SE programs, insert the installation disc
into drive A or B of the computer. The installation program,
named SETUP, must be started from within Windows.
1. From the Windows Program Manager, select “File”, and
then the “Run” command.
2. At the Run dialog box, type in the disc drive, a colon “:”,
and the file name “SETUP”.
Example: “A:SETUP” or “B:SETUP”
3. Select “OK” in the RUN dialog box.
When SETUP starts, a dialog box prompts for the directory to
store the programs. The dialog box specifies C:\EXCAL_SE
as the default program directory. If a different directory is
desired, type a directory name in the dialog box. SETUP then
reads the installation disc and copies all Excalibur SE files into
the program directory.
NOTE: During installation, Excalibur SE loads a file that is
used by other Windows applications: BWCC.DLL.
If this file already exists in the Windows directory, a
message lists several options. Select the option to save both
the new file and the existing file in the Windows directory.
Following installation, a new Program Group is created in
Windows, named Excalibur SE, with icons for each of the
Excalibur SE programs: System Setup, CAD Program, Icon
Setup, and Excalibur SE. The SETUP program then returns to
the Windows Program Manager and the Excalibur SE Program
Group, illustrated below, is available in the Program Manager
window.
The following sections of this manual provide the system setup
procedures for Excalibur SE. Refer to the Excalibur SE
Operating Instructions Manual, OP5400A for the operating
procedures of the Excalibur SE program.
INSTALLATION
1-4
EXCALIBUR SE WINDOWS
It is assumed that the user is familiar with Windows operating
procedures, and has experience in using Windows applications.
This manual does not explain “standard” Windows functions,
operating procedures, and dialog boxes, unless they differ from
Windows standards. Refer to the PC's Windows Operating
Manual/Procedures for instructions on any standard Windows
procedures, such as opening and closing programs from the
Excalibur SE Program Group.
Each Excalibur SE program is executed by opening its icon
from the Windows Excalibur SE Program Group, as for any
Windows application operation.
When an Excalibur SE program is opened, a new program
window is created. Each Excalibur SE program window
contains the standard window control box and
maximize/minimize buttons in the top line, and a menu bar
with several functions and pull-down menus. Some Excalibur
SE program windows also have a button bar, at the bottom,
containing unique action buttons.
The mouse and keyboard are the primary input devices for all
Excalibur SE programs. The left mouse button is used in
conjunction with the mouse pointer for selecting menu items,
selecting dialog box options, drawing objects, moving objects,
etc. The right mouse button is used to cancel actions or escape
from a function. If a touch-screen is installed, it may be used
in place of the mouse to select menu or dialog box items.
The keyboard can be used in place of the mouse for certain
actions. The keyboard “Enter” key is equivalent to the left
mouse button. The “Escape” key is equivalent to the right
mouse button.
The keyboard is used in dialog boxes to enter alphanumeric
data such as operator names, passwords, etc. The standard
Windows keyboard functions may also be used for most
Excalibur SE Window operations, such as the Alt key
combinations (Alt-TAB to switch between windows, Alt-F4 to
close/exit a window, etc.).
Dialog boxes
The Excalibur SE programs use dialog boxes for many
functions, with various check boxes and type-in fields within
each dialog box. Several of these are standard windows dialog
boxes, such as File Open, Save, and Print. Refer to the
Windows manual for explanation of these boxes.
The dialog boxes that are unique to Excalibur SE are explained
fully in this manual. Samples of these unique dialog boxes are
illustrated in each section of this manual.
EXCALIBUR SE SETUP
There are three setup programs for Excalibur SE:
System Setup: Section 2
CAD Program: Section 3
Icons Setup: Section 4
The Excalibur SE System Setup program defines the system
information needed by all Excalibur SE functions. This
includes defining directories for data and program files,
switcher port setup, operators and passwords, and map
sequences. This program must be run first to identify the
data directory for all other programs.
The Excalibur CAD program is a drawing program used to
create the background maps and place the icons used by
Excalibur SE. The maps must be drawn and icons placed by
the Excalibur CAD program before the Excalibur SE Icons
Setup program is run.
The Excalibur SE Icons Setup program is the setup for the
icons that reference switcher actions. This program allows the
attributes for each icon to be defined, such as a specific camera
icon calling a specified surveillance camera.
INITIAL STARTUP NOTE:
For initial setup of a new installation, certain setup
functions must be run before others, as follows:
1. Run System Setup first to set the data directory, and to
define at least one “Master” operator with System Setup
privileges.
2. Run the CAD program next to create the surveillance
area maps and to place all icons on the maps.
3. Run System Setup next to set the order of the maps and
to set up the switching system Com port.
4. Run the Icons Setup program last to set the icon
responses.
Following these initial system setup steps, additional setup
procedures can be performed in any order.
NOTE: Excalibur SE will not operate until at least one map
has been drawn, at least one icon placed on that map, the
map has been entered into the map sequence, and the data
for that icon defined using the icon setup program. Failure
to define at least one map and one icon will result in the
Excalibur SE program exiting with an error message.
1-5
INSTALLATION
Excalibur SE
System Setup
This section of the manual describes the Excalibur SE System Setup
program operating procedures. Excalibur SE System Setup is the
program that defines system data used by Excalibur SE and its related
modules. This includes defining directories for data and program files,
switcher port setup, operators and passwords, and map sequences. This
program must be run first to identify the data directory for all other
Excalibur SE programs.
Excalibur SE System Setup Program . . . . . . . . . . . . . . . . . . 2-2
INITIAL SYSTEM SETUP NOTES . . . . . . . . . . . . . . . 2-2
System Setup Menus:
Set Directory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Set Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
Sound Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Exiting Excalibur SE System Setup . . . . . . . . . . . . . . . . . . . 2-8
2-1
EXCALIBUR SE SYSTEM SETUP PROGRAM
Excalibur SE System Setup is the program that defines system
data used by Excalibur SE and its related modules. This
program is password protected and should only be accessed
only by persons authorized to make permanent configuration
changes to the system.
Excalibur SE System Setup is started by opening its icon in the
Excalibur SE Program Group. After the System Setup window
is opened, a dialog box is displayed, as illustrated below,
asking for a password.
Enter the password from the keyboard and press the enter key.
Passwords are case-sensitive and must be entered exactly as
entered during the setup for each operator. The default
password for initial setup is “UltraMax” (see Initial Setup
Notes, next section).
Following correct entry of the password, System Setup
determines if the data directory has been defined for the
system. If the directory is not defined, the user is prompted to
go directly to the Set Directory function (page 2-3).
If the data directory has been defined, the System Setup
window is cleared and any of the setup functions can be
selected from the menu bar. Excalibur SE System Setup
program provides the following functions in its menu bar:
Set Directory
Set Ports
Operators
Maps
Logs (not available in SE version)
Sound Files
Video (not available in SE version)
About
Exit
Each menu function is selected by clicking the mouse pointer
on the menu bar name or by pressing the Alt key plus the key
that is underlined in the menu name. The Logs and Video
menu entries cannot be selected in the Excalibur SE version.
The “About” function in any of the Excalibur SE programs
displays a Copyright box identifying the program version
being executed.
INITIAL SYSTEM SETUP NOTES:
1. When the Excalibur SE System Setup program is started for
the first time, a default password, “UltraMax”, must be
entered. Passwords are case-sensitive, thus ‘U’ and ‘M’
must be typed as capitals in this password. This password
is only valid when the OPERATOR.SDB file (created by
the Operators function, page 2-6) does not exist or has a
length of zero bytes.
Note: Since this is the default password into the system,
this information, should be restricted.
2. When Excalibur SE System Setup is first started and a data
directory has not been defined, an information box is
displayed indicating that there is no data directory for
System Setup. Select “OK” from this information box to go
directly to the Set Directory function, page 2-3.
3. When the system is being set up for the first time, it is
necessary to define at least one operator using the Operators
function, page 2-6. This operator must have Operator
Setup, System Setup, and Supervisor privileges.
4. When the Operators or Maps functions of System Setup
(pages 2-6 and 2-7) is selected and no data has been entered
for that function, an error message is displayed indicating
error reading the file. This error message, illustrated below,
can be ignored until the user enters the proper setup data.
If this message is displayed after any setup data has been
properly entered and saved, the error indicates a loss of that
data, and the appropriate information should be re-entered
to correct the problem. This error message may be
displayed if the data directory has been changed to a
directory that does not contain valid Excalibur SE data files.
Before re-creating maps and data files, ensure that the data
directory is set properly (page 2-3).
EXCALIBUR SE SYSTEM SETUP
2-2
SYSTEM SETUP MENUS
Set Directory Menu
The System Setup program defines the directories that contain
the program files and the data files for all other Excalibur SE
functions. The data file directory must be defined before other
data is entered by any setup functions, and before any map
images are created and saved by the Excalibur CAD program.
Note: The Excalibur SE installation program creates a default
data directory named “DATA” in the Excalibur SE program
directory defined during installation (see page 1-4).
To set the data directory, select the “Set Directory” menu item
from the System Setup menu bar. A dialog box, illustrated
below, is then displayed.
The Excalibur SE program file directory “C:\EXCAL_SE”
created by the installation program is indicated in the
“Directory” line of this dialog box. (If a different program
directory was defined during software installation, page 1-4,
this directory name will be shown in place of the EXCAL_SE
name.) A list box is shown under the Directory line, listing the
directories under this program directory.
If no data directory has been defined, there is no directory
name following the program directory name in the “Directory”
line. If a data directory has previously been defined, its full
directory path and name is shown in the “Directory” line.
Note: If a data directory has been defined, and any setup
functions, such as Operators, have been specified, DO NOT
change the data directory. If this happens, the Excalibur SE
programs will not be able to find the data files previously
defined. In this case, select the “Cancel” button to exit the
dialog box.
The data directory can be defined as the default data directory
(DATA) that was created during installation of the system
programs, or it may be a separate directory created by the user
for the data files only.
Note: If a separate data directory is wanted, it must be created
prior to operating this function.
To place the setup data files in the default “DATA” directory
(created by the installation program under the program file
directory), select this directory by double-clicking on the
“DATA” entry in the list box.
To select any other data directory, locate the desired directory
name in the list box and double-click its name. When a
directory is selected, the full directory name and path will be
displayed in the “Directory” line above the list box.
Use the standard Windows file list box actions to view other
directories in this list, such as:
* Double-clicking the [..] entry to view the next higher
directory.
* Double-clicking any directory name to view the contents of
that directory.
Any subdirectories under the selected directory will now be
displayed in the list box.
Select the OK or Cancel button to exit the Data File Directory
dialog box:
OK Button - To accept the directory selection displayed in the
Directory box above the list box, select the “OK” button.
This will write the data directory path to the
EXCALIBR.INI file in the Windows directory. At this
time, the program directory path is also written to the
EXCALIBR.INI file in the Windows directory.
Cancel Button - Select the “Cancel” button to exit without
saving the data directory definition.
2-3
EXCALIBUR SE SYSTEM SETUP
Set Ports Menu
The RS-232 serial ports are used for communications to the
Matrix Switching Systems. The serial port parameters must be
set by the Set Ports function for the port connected to the
Excalibur SE workstation before running the Icons Setup
program (Section 4).
Set up the ports by selecting “Set Ports” from the Excalibur SE
System Setup menu bar. A Setup Ports/Modules dialog box is
then displayed, as illustrated below.
The Excalibur SE Setup Ports/Modules dialog box allows
setup of only one Matrix Switcher port. The “Select Module”
option of this dialog box cannot be selected in the Excalibur
SE version.
The “Cancel” button in this dialog box returns the program to
the main System Setup window without selecting a port setup.
AD Switcher Port Setup
To set up a port for a Matrix Switcher, first select the “AD
Switcher” check box. This enables the switcher data entry
boxes below the check box. Enter the Switcher number of the
Matrix Switcher, from 1 to 9. Next, enter the Keyboard
number of this workstation, from 1 to 4. Matrix Switchers can
have up to four keyboards on an RS-232 port. The Excalibur
SE workstation is considered one keyboard by the switcher.
After entering the switcher and keyboard number, select the
“OK” button at the bottom of the dialog box. The Comm Port
Setup dialog box, illustrated on page 2-5, is then displayed.
The Comm Port Setup dialog box lists nine ports for selection,
Com 1 through Com 9. Only the Com 1 or Com 2 port can be
selected from the Excalibur SE version -- the other ports are
grayed out in the dialog box and cannot be selected. Make
sure the port selected is installed and available, or the
Excalibur SE program will issue a port open failure message
and exit when it is opened.
Note: Ensure that a valid switcher and Com Port is selected.
After a port is set by this function, it cannot be cleared from
the system, only the port parameters can be changed.
First select the Com Port connected to the switcher, then select
the desired Baud Rate, Data Bits, Stop Bits, and Parity values
for this port. Only one value can be selected in each parameter
group. The default settings are: 1200 baud, 8 data bits, 1 stop
bit, and no parity. The “Default” button at the bottom of the
dialog box resets all port parameters to the default values.
These parameters must be set to match the setting of the
Matrix Switcher's RS-232 port connected to Excalibur SE.
AD Matrix Switching Systems Notes:
* The maximum baud rate for AD Matrix Switchers is 9600.
* When defining the port configuration in the AD Matrix
Switcher setup, set the port for a TERMINAL device, NOT
a KEYBOARD device. (Refer to the appropriate Matrix
Switcher Programming Manual.)
A switcher Description (maximum of 16 characters) may be
entered to identify this switcher. This description appears in
Excalibur SE dialog boxes.
After selecting the port parameters, select the “OK” button to
save the displayed parameters and return to the main Excalibur
SE System Setup window. The “Cancel” button returns to the
System Setup window without saving the setup parameters.
EXCALIBUR SE SYSTEM SETUP
2-4
Port Setup Changes
The parameters saved for AD Switcher port is stored in the
EXCALIBR.INI file, in the Windows directory. After initial
setup of a port, the setup can be changed using the above Set
Ports function.
To change an existing port setup, select the appropriate AD
switcher and keyboard number from the Set Ports/Modules
dialog box, page 2-4, and follow the above procedures as for a
new port setup.
Note: When all port setup parameters have been saved, do not
change the settings unless a corresponding change is made
in the Matrix Switcher connected to the port.
2-5
EXCALIBUR SE SYSTEM SETUP
Operators Menu
System Setup allows the user to define system operators by
name and password, to define individual action levels, and to
assign system function access privileges to each operator.
The Excalibur SE version allows only three operators to be
entered. It is recommended that one operator be given all
privileges allowing that operator to setup and modify the
system, one operator be given supervisor status, and one
operator be given no system access privileges. This will allow
one operator to setup the system, one operator to exit the
system (supervisor), and all other guards to login as the third
operator.
To define the operators, select “Operators” from the Excalibur
SE System Setup menu bar. The Setup Operators dialog box is
then displayed, as illustrated below.
The top section of the dialog box shows the operator’s record
number, name, and password. The record number is the
relative location of this operator in the list of operators, in the
order in which they were defined. The middle section shows
the operator action levels and access privileges. The action
levels (Ack, Control, and Shunt) cannot be selected in the
Excalibur SE version.
The operators that are currently defined are displayed in the
order in which the data was entered, starting with the first
operator defined, Operator 1. Select the “Next” or “Prev”
buttons to step through the operator definitions until the
desired operator record appears.
To add an operator to the end of the list, select the “Next”
button to advance to a blank record. To change the definition
of an existing operator, press the “Next” or “Prev” buttons to
step through the operator definitions until the desired operator
record appears.
To enter or change the operator data, first enter an operator’s
name, a maximum of 25 characters, in the “Name” entry box.
Next, enter a password with a maximum of eight characters in
the “Password” entry box. Each time this operator logs in to
the system, the password must be entered exactly as entered
into this box, including capitalization.
Select the privilege codes for this operator: Operator Setup,
System Setup, Logs View/Backup, or Supervisor. These
privilege codes allow or restrict access to certain Excalibur SE
functions. Any combination of privileges can be allowed for
an operator. The Logs View/Access cannot be selected in
Excalibur SE.
Operator Setup privilege allows the operator to access the
Excalibur SE Operators setup. This privilege should be
restricted.
System Setup privilege allows the operator to enter the
setup programs and edit Excalibur SE setup data such as
icon information. This privilege should also be
restricted.
Logs View/Backup not available in SE version.
Supervisor privileges allows the operator to close
Excalibur SE or to minimize Excalibur SE.
To set the privileges, click the left mouse button on each
appropriate privilege check box. Each mouse button click sets
or clears the associated privilege.
After the desired data has been entered for an operator, select
the “Save” button at the bottom of the dialog box to store that
data before moving to another operator record. The operator
data is saved in a file named “OPERATOR.SDB”.
Note: The “Save” button must be used to save the entered data
before moving to another operator record or before using
the “Exit” to exit.
To delete an operator from the sequence, select the “Next” or
“Prev” buttons until the record for that operator is shown, then
select the “Delete” button. A Delete Record confirmation box,
illustrated on page 2-7, is displayed. Select “Yes” to delete the
operator from the sequence.
When all data has been entered as desired, select “Exit” to exit
the dialog box and return to the System Setup window.
EXCALIBUR SE SYSTEM SETUP
2-6
Maps Menu
The surveillance areas that are displayed by Excalibur SE are
viewed as a series of separate maps that have been created by
the Excalibur CAD program. The Maps function of the
System Setup program allows the user to establish the
sequence of maps, regardless of the order in which they were
created or stored by the Excalibur CAD program. A maximum
of 100 maps may be entered in an Excalibur SE sequence.
Note: The Maps function cannot be run until the desired map
files have been created using the CAD program (see Initial
Startup Note, page 1-5).
To define the map sequence setup, select the “Maps” function
from the Excalibur SE System Setup menu bar. The Setup
Maps dialog box is displayed, as illustrated below.
The map order in the current Excalibur SE display sequence is
indicated by the Map Number box at the top of this dialog box,
starting with the first map in the sequence, Map Number 1.
Press the “Next” and “Prev” buttons to step through the current
map sequence. The data directory Path is shown below the
Map Number. The current map file associated with each map
sequence position is shown in the “Map File” box below the
data directory Path.
A list box showing all the current map files in the data
directory is shown in the middle of this dialog box. The order
shown in the list box is not the order of the maps for Excalibur
SE, only the listing of the files in the data directory.
To add a new map to the end of the sequence, select the “Next”
button to advance to a blank record. Then, select a map file
entry in the list box below; that file is then displayed in the
“Map File” entry box. Alternately, type the name of the
desired map file into the “Map File” entry box. Press “Save”
at the bottom of the dialog box to record the new entry.
To insert a map into the sequence, move to the record location
where the new map is to be inserted, then select the “Insert”
button at the bottom of the dialog box; a blank record is
inserted before the map record displayed.
To enter or change the map file for the sequence number
selected, select a map file entry in the list box by clicking the
file name. The selected file is then displayed in the “Map File”
entry box. Alternately, type the name of the map file into the
“Map File” entry box. Press “OK” at the bottom of the dialog
box to record the new entry.
To delete a map from the sequence, move to the record for that
map, then select the “Delete” button. A Delete Record
confirmation box, illustrated below, is displayed.
Select “Yes” to delete the map from the sequence.
After each map file sequence has been entered or changed in
the Setup Maps dialog box, select “Save” to save the data. The
map file data is saved in a file named “MAPSETUP.SDB”.
A map file may be placed more than once into the map
sequence, however, only the first copy in the sequence is called
up from a map reference icon (see the Icons Setup program,
Map icon) or when an alarm occurs for an icon on that map.
When all data has been entered, select “Exit” to exit the dialog
box and return to the main System Setup window.
Note: Before exiting the Setup Maps dialog box, ensure that
the sequence of maps, when viewed with the “Next/Prev”
buttons, is in the desired order.
2-7
EXCALIBUR SE SYSTEM SETUP
Sound Files Menu
The Excalibur SE program can use a Windows-compatible
sound card to annunciate operator actions. Button sounds are
played when the operator presses an icon or button during
operation of the Excalibur SE program.
The “Sound Files” item of the System Setup window menu bar
provides two selections: Alarm Sound and Button Sound. The
Alarm Sound item cannot be selected from the Excalibur SE
version.
When the Button Sound entry is selected, a Select Button
Sound File dialog box is displayed, as illustrated below. The
dialog box allows selection of a directory and a sound file
(.WAV file) from that directory. Note that sound files may be
in any accessible directory.
To choose a default sound, first locate and select the desired
directory name from the right-hand list box. The selected
directory is shown in the “Dir:” field above this list box. The
sound files available in that directory are displayed in the left-
hand list box.
Next, select the sound (.WAV) file desired from the right-hand
list box. When the desired sound file is selected, the file name
is displayed in the “File:” box above the list box. Select the
“OK” button to save the data and close the dialog box.
Select “Cancel” to exit from the dialog box without saving the
selected information.
Note: If no sound card is installed in the PC, the speaker will
beep when the button is pressed. IF NO SOUND CARD IS
INSTALLED IN YOUR PC, DO NOT SELECT ANY
SOUND FILES OR THE SPEAKER WILL NOT BEEP.
EXITING EXCALIBUR SE SYSTEM SETUP
After the desired setup information has been entered via the
System Setup functions, select “Exit” from the System Setup
window menu bar to exit the program. Alternately, use the
Windows Control button to Close the program.
All of the setup information need not be entered at one time,
but all must be entered before the Excalibur SE program can
be started. The Directory, Ports, and Maps setup functions
must be completed before the Excalibur SE Icons Setup
program can be operated (see Initial Startup Note, page 1-5).
EXCALIBUR SE SYSTEM SETUP
2-8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

American Dynamics Excalibur SE Installation & Setup Instructions Manual

Type
Installation & Setup Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI