RGBlink DXP D0808 Quick start guide

Type
Quick start guide
DXP D0808 Quick Start
VIEWSIZE THE WORLD
Support any in any out
Support independent output switching
Support hot backup
Support infrared remote control
Can read and store up to 24/36 user
scenarios
Automatically recognize the formats
Support EDID management
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
1
CONTENT
Product Introduction ............................................................................................................................... 2
Packing Configuration ............................................................................................................................ 3
Hardware Orientation .............................................................................................................................. 4
Front Panel ......................................................................................................................................... 4
Back Panel ......................................................................................................................................... 5
Operating Instruction .............................................................................................................................. 6
Content ............................................................................................................................................... 6
How to Switch between Input and Output Channel .................................................................... 7
How to Switch One Input to all Outputs ...................................................................................... 7
How to Read Device Status ........................................................................................................ 8
How to Set LOGO Display when Power on ................................................................................ 8
How to Set the EDID ................................................................................................................... 8
How to Set the Language ........................................................................................................... 9
How to Realize Cascade Setting ................................................................................................ 9
How to Set the Machine Address ................................................................................................ 9
How to Realize Signal Auto Take .............................................................................................. 10
How to Lock the Front Panel .................................................................................................... 10
How to Realize Hot Backup ...................................................................................................... 10
How to Save the Preset Input and Output Channel ................................................................. 11
How to Load the Saved Input and Output Channel .................................................................. 11
How to Reset the Factory Settings ........................................................................................... 11
Contact Information............................................................................................................................... 12
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
2
Product Introduction
RGBlink strong technical strength determines
the high quality of AVDXP series matrix
switchers. We choose the chips with best
performance, elaborate design for every way
of switchers, to ensure the high quality of
switchers. After rigorous testing,
3G/HD/SD-SDI video signal, optical signal
transmission rate are 2.97Gbps, DVI switchers
signal bandwidth is 2.5 GHz, support HD
digital signal input. VGA switching signal
bandwidth is 450 MHz (-3 db), support
resolution of 2048×1536@60Hz and 1024×
768@120Hz, composite video bandwidth for
100 M (-3 db), fully meet various strict
requirements and high quality occasions.
Products in this series are widely used in large
System Connection
RGBlink offers solutions to
demanding technical problems.
Any application questions, or
required further information,
please contact with our
customer Support Engineers.
DXP D0808 System Connection Diagram
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
3
Packing Configuration
Note: Chinese Standard, American Standard or European Standard power cord is option.
The color of the screw driver is randomly when packing.
Power Cord
9-pin Serial
Cable
USB Disk
DVI HDMI 线
Antistatic Bag
防静电袋
Screw Driver
Certification
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
4
Hardware Orientation
Front Panel
Button Instruction
1~8
Selection button for input and
output channel, and number
choice of save or call saving
modes
LOAD
Load button
MENU
Menu and up arrow button
LED
indicator
Power indicator
NEXT
Down arrow button
Mode indicator
TAKE
Confirm button
Com indicator
ALL
Distributor selection button
IR receiver
Receive the infrared signal
SAVE
Save button
LCD Panel
Show operation menu items
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
5
Back Panel
Input Interface
1
DVI Input DVI-D port
Other Interface
3
RS 232 IN serial communication
interface
4
RS 232 OUT serial communication
interface
5
Switch
6
Power IEC-3 port
Output Interface
2
DVI Output DVI-D port
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
6
Operating Instruction
Content
How to Switch between Input and Output Channel
How to Switch One Input to all Outputs
How to Read Device Status
How to Set LOGO Display when Power on
How to Set the EDID
How to Set the Language
How to Realize Cascade Setting
How to Set the Machine Address
How to Realize Signal Auto Take
How to Lock the Front Panel
How to Realize Hot Backup
How to Save the Preset Input and Output Channel
How to Load the Saved Input and Output Channel
How to Reset the Factory Settings
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
7
How to Switch between Input and Output Channel
User can switch the signals between input and output channel by front panel buttons of
DXP D0808, specific operations are as follows:
1. If choose “AUTO TAKE ON”, push any button on output area on the front panel, for example,
choose [5] as the output channel.
Then push any button on Input area on the front panel, for example, choose [3] as the input
channel, the signal of output channel 5 will be switched to the signal of input 3.
2. If choose “AUTO TAKE OFF”, push any button on output area on the front panel, for
example, choose [5] as the output channel.
Then push any button on input area on the front panel, for example, choose [3] as the input
Channel. After setting, push the [TAKE] button to confirm.
Note: Input channel: The signal that will be switched to output channel.
Output channel: The signal that connected to display device.
The number [1]~[8] means channel 1~8.
How to Switch One Input to all Outputs
1. If choose “AUTO TAKE ON”, push the [ALL] button on the front panel.
Then push any button on input area on the front panel, for example, choose [3] as the input
channel, all the signal of output channel will be switched to the signal of input 3.
2. If choose “AUTO TAKE OFF”, push the [ALL] button on the front panel.
Then push any button on Input area in the front panel, for example, choose [3] as the input channel.
Push the [TAKE] button to confirm, all the signal of output channel will be switched to the signal
of input 3.
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
8
How to Read Device Status
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. System default [STATUS] option, if it is not selected, push the [MENU] up arrow button or
[NEXT] down arrow button, and choose [STATUS].
3. Push the [TAKE] button to confirm, user can view the current device status. The first four
screen show each output to the corresponding input channel. The fifth screen shows the
software version, the sixth screen shows the serial number and the seventh screen shows
the machine address.
How to Set LOGO Display when Power on
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [LOGO].
3. Push the [TAKE] button to confirm, and enter to LOGO setting, push the [NEXT] button
to choose “ON” or “OFF”, then push the [TAKE] button to confirm.
How to Set the EDID
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [EDID].
3. Push the [TAKE] button to confirm.
4. Push any button on output area on the front panel, for example, choose [3] as the output channel.
5. Push any button on input area on the front panel, for example, choose [5] as the input channel.
6. Push the [TAKE] to confirm, and the EDID copy finish.
Note: When set the EDID, the output interface must be connected to monitors.
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
9
How to Set the Language
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [LANGUAGE].
3. Push the [TAKE] button to confirm, and enter to the language setting.
4. Push the [NEXT] button to choose the language, for example, choose “ENGLISH”, then
push the [TAKE] button to confirm.
How to Realize Cascade Setting
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [CASCADE].
3. Push the [TAKE] button to confirm, and enter to the cascade setting. Push the [NEXT]
button to choose “ON” or “OFF”, then push the [TAKE] button to confirm.
How to Set the Machine Address
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [MAC ADDR].
3. Push the [TAKE] button to confirm. Push any one of button [1]~[8] on output area to set the
machine address. Push the [TAKE] button to confirm after setting.
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
10
How to Realize Signal Auto Take
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [AUTO TAKE].
3. Push the [TAKE] button to confirm, and enter to the auto take setting. Push the [NEXT]
button to choose “ON” or “OFF”, then push the [TAKE] button to confirm. System default the
status is “ON”, and when switch the signal, user need not to push the [TAKE] button.
How to Lock the Front Panel
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [LOCK].
3. Push the [TAKE] button to confirm. Push the [NEXT] button to choose “ON” or “OFF”, then
push the [TAKE] button to confirm. Push the [MENU] button for 3 seconds to unlock panel.
How to Realize Hot Backup
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [HOT BACKUP].
3. Push the [TAKE] button to confirm, and enter to hot backup function setting. Push the [NEXT]
button to choose “ON” or “OFF”, then push the [TAKE] button to confirm.
Inputs 1 ~ 8 are any combination of backup, it will recall another backup if one signal has
problem. The detailed parameters can be set on windows control program, and invalid for
button operation.
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
11
How to Save the Preset Input and Output Channel
1. Push the [SAVE] button on the front panel, the button light is on. At the same time, some
buttons [1]~[8] in output and input area are on and some flash. Button is on can be saved,
and button flashes will be overwrite.
2. Choose the button on to save, the LED screen will show save complete.
3. If choose the button flash, the information saved before will be overwrite.
4. Push the [TAKE] button to confirm, and push [MENU] button to cancel.
5. Push the [MENU] to exit the save state, or push the [SAVE] button, the light is off, and exit
the save state.
Note: The buttons [1]~[8] on output area corresponding to save 1~8, and the buttons [1]~[8]
on output area corresponding to save 9~16.
How to Load the Saved Input and Output Channel
1. Push the [LOAD] button on the front panel, the button light is on. At the same time, some
buttons [1]~[8] in output and input area are on and some flash. Button on is ready for recall,
and button flashes means just recall. Push the button on to recall.
2. Push the [MENU] button to exit the load state, or push the [LOAD] button, the button light is
off, and exit the load state.
How to Reset the Factory Settings
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [RESET].
3. Push the [TAKE] button to confirm.
4. Push any key to reset factory settings, and push the [MENU] button to exit.
AddressS603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: s[email protected] http://www.rgblink.cn
12
Contact Information
Warranty:
All video products are designed and tested to the highest quality standard and backed by
full 3 years parts and labor warranty. Warranties are effective upon delivery date to
customer and are non-transferable. RGBlink warranties are only valid to the original
purchase/owner. Warranty related repairs include parts and labor, but do not include
faults resulting from user negligence, special modification, lighting strikes, abuse
(drop/crush), and/or other unusual damages.
The customer shall pay shipping charges when unit is returned for repair.
Headquarter: S603~604 Weiye Building Torch Hi-Tech Industrial Development Zone
Xiamen, Fujian Province, P.R.C
Tel: +86-592-5771197
Fax: +86-592-5771202
Customer Hotline: 4008-592-315
Web:
~ http://www.rgblink.com
~ http://www.rgblink.cn
E-mail: s[email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

RGBlink DXP D0808 Quick start guide

Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI