PEAK-System PCAN-MiniDiag FD Quick start guide

Type
Quick start guide

PEAK-System PCAN-MiniDiag FD is a versatile device designed for basic diagnostics and checking of CAN and CAN FD buses. It features various functions to assist you in troubleshooting and evaluating the performance of your CAN bus systems. With its compact size and user-friendly interface, the PCAN-MiniDiag FD offers convenient and efficient ways to:

  • Obtain system information, including firmware and hardware versions, serial number, and battery voltage.
  • Check voltage levels at specific pins of the D-Sub connector, ranging from -40 to 43 V.
  • Measure minimum and maximum voltage values for CAN-High and CAN-Low signals within a range of -5 to 8 V.

PEAK-System PCAN-MiniDiag FD is a versatile device designed for basic diagnostics and checking of CAN and CAN FD buses. It features various functions to assist you in troubleshooting and evaluating the performance of your CAN bus systems. With its compact size and user-friendly interface, the PCAN-MiniDiag FD offers convenient and efficient ways to:

  • Obtain system information, including firmware and hardware versions, serial number, and battery voltage.
  • Check voltage levels at specific pins of the D-Sub connector, ranging from -40 to 43 V.
  • Measure minimum and maximum voltage values for CAN-High and CAN-Low signals within a range of -5 to 8 V.
PCAN-MiniDiag FD
Quick Start Guide
Operation
Voltage Supply
Insert the three supplied AAA batteries into the
battery case on the underside of the device.
CAN Connection
Connect the PCAN-MiniDiag FD to a CAN bus
via the D-Sub connector on the rear of the
device. The pin assignment corresponds to the
specification CiA® 303-1 (pin 2: CAN-Low, pin 7:
CAN-High).
Switching On and Off
Press the Enter key once to switch on
the PCAN-MiniDiag FD. Press and hold
the Enter key for three seconds to
switch the device off again.
Operating the Device
Navigating between device
functions and selecting
settings.
Opening the options of the current
device function or discarding
changed settings.
Executing actions or confirming
changed settings.
Device Functions
The PCAN-MiniDiag FD has eight functions for
basic diagnosis and checking of CAN and
CAN FD buses.
System Info: Indication of firmware and
hardware version, serial number, and
battery voltage
D-Sub Voltages: Voltage check at the pins 6
and 9 in the range from -40 to 43 V
CAN Min/Max: Measurement of minimum
and maximum voltage values for CAN-High
and CAN-Low in the range from -5 to 8 V
CAN Voltages: Measurement of dominant
and recessive levels for CAN-High and
CAN-Low in the range from -5 to 8 V
CAN Voltages 2: Measurement of minimum,
mean, and maximum values of the
dominant and recessive levels
Termination: Measurement of termination
on the CAN bus
Bit Rate: Automatic detection or manual
configuration of the transmission rates
Bus Load: Measurement of the CAN bus
load with display in diagram
Statistics: Counter for CAN, CAN FD, and
error frames
Attention! Do not apply voltages out of the
measuring ranges in order to avoid damage to
devices and persons.
Simplified EU Declaration
of Conformity
PEAK-System Technik GmbH declares: The
product PCAN-MiniDiag FD (IPEH-003070) is in
compliance with the EU directives 2014/30/EU
(EMC) and 2011/65/EU (RoHS 2).
The full text of the EU Declaration of
Conformity can be found in the detailed
documentation of the PCAN-MiniDiag FD.
Documentation
You can open the detailed
documentation of the
PCAN-MiniDiag FD with
this link:
www.peak-system.com/quick/Doc3070E
PEAK-System Technik GmbH
Otto-Roehm-Str. 69, 64293 Darmstadt
Germany
Phone: + 49 6151 8173-20
E-mail: info@peak-system.com
www.peak-system.com
© 2020-01 PEAK-System Technik GmbH
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

PEAK-System PCAN-MiniDiag FD Quick start guide

Type
Quick start guide

PEAK-System PCAN-MiniDiag FD is a versatile device designed for basic diagnostics and checking of CAN and CAN FD buses. It features various functions to assist you in troubleshooting and evaluating the performance of your CAN bus systems. With its compact size and user-friendly interface, the PCAN-MiniDiag FD offers convenient and efficient ways to:

  • Obtain system information, including firmware and hardware versions, serial number, and battery voltage.
  • Check voltage levels at specific pins of the D-Sub connector, ranging from -40 to 43 V.
  • Measure minimum and maximum voltage values for CAN-High and CAN-Low signals within a range of -5 to 8 V.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI