Euri Lighting ET8-2150T-12 Installation guide

Type
Installation guide
USE LED LAMPS ONLY. THIS LUMINAIRE HAS
BEEN MODIFIED TO USE LED LAMPS AND
CAN NO LONGER OPERATE THE ORGINALLY
INTENDED FLUORESCENT LAMPS SAFELY.
FLOURESCENT LAMPS COULD BREAK AND CAUSE PERSONAL INJURY
IF USED IN THIS FIXTURE.
!
WARNING!
INSTALLATION GUIDE
MODEL #:
ET8-2140T-12 / ET8-2150T-12 / ET8-2140T-15 / ET8-2150T-15
©2017. Euri Lighting | A Division of IRTRONIX Inc. All Rights Reserved
For customer service please call us at 1-888-743-5766
Ofce Hours: 8:00 a.m. – 5:00 p.m. PST Monday-Friday
Questions?
WARNING!
DOUBLE ENDED INSTALLATION IS NOT RECOMMENDED
DUE TO POTENTIAL RISK OF FIRE OR ELECTRIC SHOCK
THIS PRODUCT MAY NOT BE COMPATIBLE WITH ALL BALLASTS, FOR MORE INFORMATION ABOUT BALLAST COMPATIBILITY PLEASE VISIT: WWW.EURILIGHTING.COM
Linear Series | T8 Class
4 ft. Bypass Ballast LED Tube
PLEASE REVIEW THE INSTRUCTIONS AND WARNINGS LISTED BELOW PRIOR TO PROPER INSTALLATION
This LED lamp is intended to replace uorescent t8 tube lamps with an ANSI designation 32W/48T8/RS, 32W/48T8
WARNINGS CAUTIONS
Risk of fire
LED tube bypass ballast installation requires knowledge of
luminaire electrical systems.
(If you are not a qualified electrician, please do not attempt installation.)
Risk of electric shock – turn-off power at source before installation
Do not make or alter any open holes in an enclosure of wiring or
electrical components during installation.
If lamp or luminaire exhibits abnormal operation (buzzing, flickering,
minimal light, etc.), turn off power, remove lamp and contact us. For
more information please visit www.eurilighting.com or call our toll-free
number 1-888-743-5766.
Do not use with dimmers.
• Do not look directly at the operating Bypass Ballast LED T8 Lamp.
Do not touch this product with wet hands.
Do not disassemble, repair or alter lamp.
Designed for indoor applications only.
Suitable for damp locations.
The luminaires shall be grounded.
Avoid contact with lamp pins during installation.
This Device is not intended for use with emergency exits or
emergency lights.
WHEN BYPASSING A BALLAST ALWAYS HAVE A QUALIFIED ELECTRICIAN DO YOUR ELECTRICAL WORK.
BYPASS BALLAST INSTALLATION INSTRUCTIONS
Single Ended Bypassing of Magnetic / Electronic Ballast
1. Turn-off power before installation.
2. Remove the existing ballast and existing starter (If present)
3. Replace uorescent tube with LED Tube
4. Remove any pre-existing labels and replace them with the labels provided with this product.
FOR BYPASS INSTALLATION
SINGLE ENDED INSTALLATION ONLY.
(
PROFESSIONAL INSTALLATION IS REQUIRED.)
STEP 3
L N
LED Tube
L
N
LED Tube
MAGNETIC BALLAST
STEP 1 STEP 2
(continue to step 3 below)
L N
Fluorescent Lamp
Magnetic Ballast
Traditional Starter
L N
LED Tube
Magnetic Ballast
Traditional Starter
»
STEP 1 STEP 2 (continue to step 3 below)
STEP 4
ELECTRONIC BALLAST
L N
LED Tube
Electronic Ballast
L
N
Fluorescent Lamp
a
b
Electronic Ballast
»
Bypass Ballast
Remove any pre-existing labels and replace them
with the labels provided with this product.
Use end labeled with letter “A
  • Page 1 1

Euri Lighting ET8-2150T-12 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI