Euri Lighting ET8-1140H Installation guide

Type
Installation guide
INSTALLATION GUIDE
MODEL #: ET8-1140H
©2016. Euri Lighting | A Division of IRTRONIX Inc. All Rights Reserved
For customer service please call us at 1-888-743-5766
Ofce Hours: 8:00 a.m. – 5:00 p.m. PST Monday-Friday
Questions?
WARNING!
DOUBLE ENDED INSTALLATION IS NOT RECOMMENDED
DUE TO POTENTIAL RISK OF FIRE OR ELECTRIC SHOCK
THIS PRODUCT MAY NOT BE COMPATIBLE WITH ALL BALLASTS, FOR MORE INFORMATION ABOUT BALLAST COMPATIBILITY PLEASE VISIT: WWW.EURILIGHTING.COM
Linear Series | T8 Class
4 ft. Hybrid LED Tube
PLEASE REVIEW THE INSTRUCTIONS AND WARNINGS LISTED BELOW PRIOR TO PROPER INSTALLATION
This LED tube is intended to replace uorescent tube lamps with an ANSI designation 32W/48T8/RS, 32W/48T8
WARNINGS CAUTIONS
Risk of fire / electrical shock Do not use with dimmers.
LED Hybrid Tube bypass ballast installation requires knowledge of luminaire electrical systems.
(If you are not a qualified electrician, please do not attempt bypass ballast installation.)
• Do not look directly at the operating LED Hybrid Tube.
Risk of electric shock – disconnect power at source before installation Do not touch this product with wet hands.
Do not make or alter any open holes in an enclosure of wiring or electrical components during
installation.
Do not disassemble, repair or alter lamp.
If lamp or luminaire exhibits abnormal operation (buzzing, flickering, minimal light, etc.), turn off
power, remove lamp and contact us. For more information please visit www.eurilighting.com or
call our toll-free number 1-888-743-5766.
Designed for indoor applications only.
Suitable for damp locations.
The luminaires shall be grounded.
Be careful not to touch the lamp pins to the metal housing when installing.
This Device is not intended for use with emergency exits or emergency lights.
WHEN BYPASSING A BALLAST ALWAYS HAVE A QUALIFIED ELECTRICIAN DO YOUR ELECTRICAL WORK.
DIRECT REPLACEMENT INSTALLATION INSTRUCTIONS
1. Turn-off power before installation | 2. Replace traditional uorescent tube with LED Hybrid tube | 3.Turn-on power and enjoy your new LED Hybrid Tube.
BYPASS BALLAST INSTALLATION INSTRUCTIONS
Single Ended Bypassing of Magnetic / Electronic Ballast
1. Turn-off power before installation.
2. Remove the existing ballast and existing starter (If present)
3. Replace uorescent tube with LED Hybrid Tube
FOR BYPASS INSTALLATION
SINGLE ENDED INSTALLATION ONLY.
(
PROFESSIONAL INSTALLATION IS REQUIRED.)
STEP 3
OR
L N
LED Hybrid Tube
L N
LED Hybrid Tube
L
N
LED Hybrid Tube
MAGNETIC BALLAST
STEP 1 STEP 2
L N
Fluorescent Lamp
Magnetic Ballast
Traditional Starter
L N
LED Hybrid Tube
Magnetic Ballast
Traditional Starter
»
STEP 1 STEP 2
ELECTRONIC BALLAST
L N
LED Hybrid Tube
Electronic Ballast
L
N
Fluorescent Lamp
a
b
Electronic Ballast
»
  • Page 1 1

Euri Lighting ET8-1140H Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI