TA/600EN 24811460 25-02-15
The rst number ashes ; use the arrows to en-
ter the rst digit of the code, touch the area highlighted
to move on to the next digit; pressing button at
any time means the code entered is considered valid and
you move on to the next parameter to be congured.
Setting the type of heat management algorithm
Use the arrows to choose the type of algorithm
to apply for system management from:
= Differential
= Proportional Integral
Dierential Algorithm
If, on screen , using the arrows, the dierential
algorithm type has been chosen, press the button
to customise the value of the dierential, using the
arrows .
Note. The range of adjustment goes from 0 to 1°C.
This function is useful for environments that are par-
ticularly hard to air condition, with extreme variations
Changing the calibration of the temperature
detection probe
If the location of the device does not permit suitable
detection of the temperature, it is possible to change
the temperature detected by ±3 °C with increases of a
tenth of a degree.
Use the arrows to change the data detected
by the desired value and/or press the button to move
on to the next parameter to be congured.