CAME TA/P1 Installation guide

Type
Installation guide

Below you will find brief information for Thermostat TA/P1. This device is an indoor thermostat designed for controlling the temperature in a zone within CAME home automation systems. It features an input for connecting an OH/STI or PT1000 temperature sensor and can also function as a digital input for devices such as window contacts. It is adaptable to various wiring systems with subframes and hole cover adapters. The thermostat allows for automatic, manual, scheduled manual, and 'Jolly' temperature control modes as well as zone exclusion. It has a backlit LCD graphic display and is powered by the home automation bus line.

Below you will find brief information for Thermostat TA/P1. This device is an indoor thermostat designed for controlling the temperature in a zone within CAME home automation systems. It features an input for connecting an OH/STI or PT1000 temperature sensor and can also function as a digital input for devices such as window contacts. It is adaptable to various wiring systems with subframes and hole cover adapters. The thermostat allows for automatic, manual, scheduled manual, and 'Jolly' temperature control modes as well as zone exclusion. It has a backlit LCD graphic display and is powered by the home automation bus line.

Thermostat for controlling the
zone temperature
TA/P1
INSTALLATION AND USE MANUAL
EN
English
FA01733-EN
Page 2 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Description
Indoor thermostat, for controlling the temperature in a temperature zone in CAME home-
automation systems.
The device is fitted with an input ( ) to which you can connect an OH/STI remote temperature
sensor or a PT1000-type temperature sensor; the same input may be used as a digital input,
for example, as a window contact.
General Precautions
Important people-safety instructions: READ CAREFULLY!
Installing, programming, commissioning and maintenance must only be done by qualified,
expert sta and in full compliance with the applicable law.
Wear antistatic protective clothing when working on the control board.
Keep these precautions.
Always cut o the electrical power-supply when performing any installation or maintenance
operations.
This product must only be used for its specifically intended purpose. Any other use is
dangerous.
The manufacturer declines all liability for any damage as a result of improper, incorrect
or unreasonable use.
DISPOSAL Make sure the packaging material is not disposed of in nature, but rather disposed
of in compliance with the laws in eect in the country in which the product is being used.
At the end of the product’s life cycle, make sure it is not disposed of in nature. The equipment
must be disposed of in compliance with current laws and its components recycled where
possible. The components that should be recycled are marked with the material’s ID marker.
Pertinent Regulations - The product complies with current pertinent legislative standards.
ABCDE
a b
ABCDE a b
ABCDE a b
Page 3 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Installing
Description of parts
FrameMain body
Screws for fastening
to the recess-mounted box
Cover.
Hole cap adapters.
Subframes
The subframes and appropriately paired hole cover adapters allow the device to be adapted
to most wiring systems available, following the instructions on the following pages.
The System, Playbus, Playbus Young, Chorus brands are owned by GEWISS S.p.A.
The Light, Light Tech, Living International, Axolute, Luna, Livinglight Quadre, Matix, Livin-
glight Tonde, Livinglight AIR, Axolute Air, Living Now brands are owned by BTICINO S.p.A.
The Plana, Eikon, Idea, Idea Rondò, Arché, Eikon Evo brands are owned by VIMAR S.p.A.
The Vela Quadra, Vela Tonda, Serie Cross brands are owned by LEGRAND S.p.A.
The Banquise, Sistema 45, Serie 44 brands are owned by AVE S.p.A.
The Elos brand is owned by ABB S.p.A.
A
A
a
a
A
b
b
Page 4 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
How to pair/adapt the subframes to the wiring systems
GEWISS - Playbus, Playbus
Young.
BTICINO - Matix.
BTICINO - Light, Light Tech,
Living International.
VIMAR - Plana, Eikon.
LEGRAND - Vela Quadra,
Vela Tonda, Serie Cross.
B
a
a
B
a
B
a
a
Page 5 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
VIMAR - Idea, Idea Rondò.
ABB - Elos.
AVE - Banquise, Sistema 45.
C
C
B
Page 6 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
BTICINO - Livinglight Qua-
dre.
VIMAR - Arché
BTICINO - Livinglight Tonde.
GEWISS - Chorus.
GEWISS - System.
BTICINO - Axolute, Luna.
E
E
D
Page 7 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
AVE - Serie 44. BTICINO -
Livinglight AIR.
VIMAR - Eikon Evo.
BTICINO - Axolute Air,
Living Now (with Kit Cover
845XC-0010).
NCNA C
LA
1 2
TA/P1
67200081
G
A
Page 8 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Electrical connections
Install the device in a place suitable
for detecting the room's tempera-
ture, possibly onto an inside wall,
and avoid any nooks, behind doors,
near curtains or heat sources.
Installing
Free type of connection.
We suggest using a BUS CAME NH-C1D cable (insulated for 750 V); alternatively, you can
use a twisted pair cable in compliance with regulatory standard CEI 46-5, and having the
following characteristics:
- 0.28 mm2 conductors' section;
- typical impedance from 90 a 120 Ω;
- capacity at 800 Hz from 60 to 130 nF/km;
- electrical resistance at 20 °C max 67 Ω/Km.
It is important to remember that when using a non-insulated, CEI 46-5-compliant, telephone
twisted pair cable, for the voltages dealt with, it must be laid in specific conduits, and must
not be used to wire 230 V AC voltages.
BUS line connection
Digital input to which it is
possible to connect a button or
remote sensor.
The module must be connected
to the home-automation bus via
a non-screened, non-polarized,
double, twisted cable.
2
1
B
C
ED
Page 9 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
If you have to replace the counter
frame, or the cover, proceed as
shown in figures C, D, E.
Once the frame and counter frame
are assembled, which are chosen
according to the plate that will be
mounted, and after having made all
electrical connections, assemble
the device as shown in figure B.
②③④⑤⑥
⑬ ⑫
⑦⑧⑨⑩⑪
Page 10 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Meaning of the icons on the display and of the function buttons
Using the device
Active window-contact.
Active keypad lock.
System operating
in cooling mode.
System operating
in heating mode.
System operation
in antifreeze mode.
Zone excluded from temperature
control.
Active automatic control of the
temperature zone.
Jolly program in operation.
Active manual control of the
temperature zone.
Active scheduled manual control
of the temperature zone.
Cooling or heating operational
and fan coil speed.
Cooler in operation.
Heater in operation.
Buttons for adjusting the
temperature in manual mode.
Button for selecting the operating
mode. (MANUAL, AUTOMATIC,
JOLLY, EXCLUSION).
Temperature sensor and state-
alert LED.
Button for selecting the datum
to view on the display: detected
temperature or current time
Detected temperature or
current time.
Page 11 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Do not touch the temperature sensor, to prevent it from misreading the detected value.
To clean this device only use a soft, water-moistened cloth.
- This icon appearing on the display means that the keypad is locked by the terminal and
that no operations can be done locally.
- The module can control the zone's temperature even if a control terminal is malfunctioning
or missing.
Identifying the device on home-automation systems
On the back of the device, there is a tag bearing the alphanumerical code that identifies the
device (serial number "SN") within a home-automation system.
To send the serial number or SN to the programming software over the home-automation
bus, press these buttons simultaneously for at least two seconds; the front LED turns
on for one second to confirm that the serial number has been transmitted.
When the front LED is always on, it means the device is malfunctioning.
Local settings allowed on the zone thermostat
The TA/P1 zone thermostat works according to the settings that have been programmed via
the interface of the home-automation system of which it is a part; the only local operation
allowed is the variation of the zone module's operating mode, by pressing this button .
Automatic operation
The module control the temperature, according to the temperature profile set via the home-
automation system's interface.
Manual operation
By pressing these buttons you can change - by ±2 °C - the value set by the home-
automation system's interface; the set temperature will remain steady until it is programmed
otherwise or the mode is changed.
Scheduled manual operation
By pressing these buttons you can establish for how long the temperature, which is set
for manual operation, must be maintained.
After about three seconds from the latest operation, the room-temperature reading will appear.
Jolly
The module controls the temperature according to the temperature profile set via the home-
automation system's interface of the Jolly program.
After about three seconds from the latest operation, the room-temperature reading will appear.
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 12 - Manual FA01733-EN - 10/2021 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Technical features
Home appliance.
Backlit LCD graphic display.
Power supply from bus line.
• Absorption:
8mA MAX (with backlighting on),
5mA (with backlighting o)
Antifreeze temperature: +8 °C.
Room-temperature detection interval:
15 s.
Sensitivity of the temperature sensor
- Range: from 0 to +40 °C
- Resolution: 0.1 °C
- Precision: ±0.3 °C (±0.5°C with
PT1000)
Protection rating: IP30.
Operating temperature: from 0 °C to
+40 °C.
Input used for the auxiliary tem-
perature sensor
Maximum distance of the sensor from
the device: 2 meters.
Types of sensors that can be connected
to the input:
- OH/STI, (NTC 10K, Beta 3977 sensors),
- PT1000, linear variation of 3.85 Ω/°C.
Input used as a digital input
Maximum distance between the button
and the input: 20 m. The distance
is reduced to 10 meters if the input
cables, which are duly insulated, are
laid alongside the mains power-supply
conductors.
Excluding a zone from temperature control
Control over the temperature zone is deactivated.
After about three seconds from the latest operation, the room-temperature reading will appear.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

CAME TA/P1 Installation guide

Type
Installation guide

Below you will find brief information for Thermostat TA/P1. This device is an indoor thermostat designed for controlling the temperature in a zone within CAME home automation systems. It features an input for connecting an OH/STI or PT1000 temperature sensor and can also function as a digital input for devices such as window contacts. It is adaptable to various wiring systems with subframes and hole cover adapters. The thermostat allows for automatic, manual, scheduled manual, and 'Jolly' temperature control modes as well as zone exclusion. It has a backlit LCD graphic display and is powered by the home automation bus line.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI