Audix M70 is a professional microphone designed for reliable service and optimal sound quality. Its versatile features make it suitable for various applications, including ceiling installations in conference rooms, auditoriums, and other venues. The M70's low-profile design and threaded post mounting system allow for easy and secure installation, while the included junction box provides convenient access for wiring and maintenance.

Audix M70 is a professional microphone designed for reliable service and optimal sound quality. Its versatile features make it suitable for various applications, including ceiling installations in conference rooms, auditoriums, and other venues. The M70's low-profile design and threaded post mounting system allow for easy and secure installation, while the included junction box provides convenient access for wiring and maintenance.

PROFESSIONAL MICROPHONES
PROFESSIONAL MICROPHONES
AUDIX M70
INSTALLATION GUIDE
Thank you for choosing Audix! Our products are designed to provide many years of
reliable service. Please read this manual before using the system
for optimal installation and operation.
M70 EXPLODED VIEW
M70 JUNCTION BOX ASSEMBLY
M70 WITH
THREADED POST
AND KNURLED NUT
• REMOVE M70 MIC FROM JBM70
• REMOVE FOAM FOR EASY ACCESS TO JMB70 BOX
• DRILL 2 INCH HOLE IN THE CEILING TILE
• PLACE JBM70 BOX OVER THE CEILING TILE 2 INCH HOLE
• INSERT M70 THROUGH HOLE “A” AND ROTATE TO HOLE “B”
• SECURELY TIGHTEN THE KNURLED BRASS FASTENERS
• INSERT FOAM BACK INTO JBM70
• INSERT PLENUM WIRE (BELDEN 9451P OR 82761 OR EQUIVALENT THROUGH STRAIN RELIEF (SEE #2)
• TERMINATE TO MALE TERMINAL BLOCK CONNECTOR (SEE #3)
• INSTALL TO M70 MATING CONNECTOR (SEE #4)
• TIGHTEN STRAIN RELIEF AND CLOSE LID OF JMB70 BOX (SEE #5)
• ADJUST MIC POSITION (SEE #6)
SLIDE THE THREADED POSTS INTO
HOLE “A”. TWIST CLOCKWISE TO HOLE
“B” AND TIGHTEN THE KNURLED NUTS
SECURELY.
3 PIN TERMINAL BLOCK
CONNECTORS
JBM70 UL RATED
PLENUM RATED BOX
BRASS
STRAIN
RELIEF FOR
OUTER CABLE
BOTTOM VIEW OF
JUNCTION BOX
CEILING TILE
WITH2″HOLE
A
B
B
A
MOUNTING AND WIRING INSTRUCTIONS
FOR M70
To adjust microphone,
unscrew the grill assembly.
Wiring:
1 = Ground
2 = Blue (+)
3 = Yellow (-)
Open lid of junction box.
Separate the supplied 3 pin
connectors (male/female).
Connect terminal connectors.
Insert plenum cable through
strain relief nut, then connect to
the terminal.
Recommended cable:
Belden 9451P - .124" O.D. or
Belden 82761 - .116" O.D.
Tighten down the strain relief
nut to hold wire rmly in place
and close junction box lid.
For further information contact Audix at 503.682.6933
www.audixusa.com
3
3
2
1
2
1
6
3
1
4
2
5
Male to Au-
dio Cable
Female to
Mic
SEISMIC/FIRE RESTRAINT INSTRUCTION
CABLE EXPLODED VIEW
CABLE
CABLE STAY
BARREL
PUSH PIN IN
TO RELEASE
CABLE RELEASE
PIN
Wrap the cable around a beam, eyebolt or hanger. Next,
slip the cable through the top of cable stay barrel pulling
excess cable until taut.
To release cable, depress the cable release pin on either
end to release the loop or to extend cable length.
g
g g
g g g
g g
g g
ver 3.0 0715
g
UL RATED PLENUM
RATED BOX
PLENUM RATED CABLE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Audix M70 Installation guide

Type
Installation guide

Audix M70 is a professional microphone designed for reliable service and optimal sound quality. Its versatile features make it suitable for various applications, including ceiling installations in conference rooms, auditoriums, and other venues. The M70's low-profile design and threaded post mounting system allow for easy and secure installation, while the included junction box provides convenient access for wiring and maintenance.