Audix M60 Phoenix Connector User guide

  • I've reviewed the wiring instructions for the Audix M60 series, including the M60P and M60NP models. The document provides detailed steps on how to connect and disconnect Phoenix connectors, as well as a recommended wiring scheme. I am ready to address any questions you may have regarding these connectors and the wiring process for the M60.
  • What is included with the M60?
    What is the wiring scheme?
    What wires are recommended for the M60?
STEP 1
The M60 ships with the male Phoenix connector already
attached to the wire, however, a complete set of male and
female connectors are provided for your convenience.
Disconnect the female Phoenix connector from the assembly
by simply pulling apart.
STEP 2
Wiring Scheme:
1 = Ground
2 = Blue (+)
3 = Yellow (-)
Strip back wire and attach to the screw on terminals per the
wiring scheme.
Recommended wire for the M60 is:
Belden 9451P with .124” O.D. or
Belden 82761 with .116” O.D.
STEP 3
Once wires are firmly attached, reconnect both Phoenix
terminals making sure that they are fully engaged and secure.
MODELS M60P, M60NP
Wiring Instructions
M60 with Phoenix Connectors
a
udixusa.com
©2017 Audix Corporation All Rights
Reserved.
Audix and the Audix Logo are
trademarks of Audix Corporation.
/