Z-Wave VRI10-1LZ Installation guide

Category
Dimmers
Type
Installation guide
Single Pole (One location) or 3-Way (Multi-location)
Scene Capable Incandescent Dimmer
Cat. No. VRI1
Ø
-1L, 1000W (Lighted)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
DI-000-VRI10-02A
WARNINGS AND CAUTIONS:
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualiedelectrician.
• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,uorescentlighting,amotor-oratransformer-operatedappliance.
• Usewithincandescentor120Vhalogenxturesonly.
•
Vizia RF +
TM
dimmersarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleVizia+™orViziaRF+
TM
remotesformulti-locationdimming.
• Useonlyone(1)ViziaRF+™dimmerinamulti-locationcircuitwithupto9coordinatingremotes(withoutLEDs)orupto4matchingremotes(withLEDs).Theremote(s)willturnthe
lightonatthebrightnesslevelselectedatthedimmer.
WARNINGS AND CAUTIONS:
• Dimmermaynotoperatewithdiodedlamps(SylvaniaDesigner16™orPhilipsPAR-16™).
• Totalminimumloadmustexceed40W.
• Dimmermayfeelwarmtothetouchduringnormaloperation.
• Recommendedminimumwallboxdepthis2-1/2”.
• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.
• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.
• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.
INSTALLING YOUR DIMMER
NOTE: UsecheckboxeswhenStepsarecompleted.
2
4
BK
RD
YL/RD
1
3
5
Coordinating Remote
Dimmer
5
2
1
Black
Green
R ed
Yellow/Red
4
3
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote (no LEDS)
YL/RD
YL/RD
RD
WH
RD
BK
BK
Black
Do not use for
incandescent
applications.
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Tools needed to install your Dimmer
Slotted/PhillipsScrewdriver ElectricalTape
Pliers Pencil
Cutters Ruler
3-Way Wiring with Coordinating Remote
(no LEDs) Application:
Step 4b
Green
Ground
Hot (Black)
Neutral (White)
Load
Dimmer
Black
White
Line
120VAC, 60Hz
Black
Yellow/Red
Red
Insulating
Label
Single-Pole Wiring Application:
Step 4a
Black
Green
Red
Yellow/Red
Dimmer
Insulating Label:
This wire is used in
3-way installations
only. For single pole
installations, do
not remove this
insulating label.
4
3
2
1
IMPORTANT:
For3-Wayapplications,notethatoneofthescrewterminals
fromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)
orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthe
common(LineorLoad)inboththedimmerwallboxandremotewallbox.
Step 2
Identifying your wiring application
(most common):
NOTE:Ifthewiringinthewallboxdoesnotresemble
anyofthesecongurations,consultaqualied
electrician.
2
4
3
1
2
4
1
5
3
3-Way
1. Line or Load
(See important
instruction
below)
2. Neutral
3. Ground
4. FirstTraveler
– note color
5. SecondTraveler
– note color
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
INTRODUCTION
Leviton’s
Vizia RF +
TM
componentsaredesignedtocommunicate
witheachotherviaRadioFrequency(RF)toprovideremotecontrol
ofyourlighting.UsingRFtechnologyallowsLevitontoprovidethe
greatestsignalintegritypossible.EachmoduleinLeviton’s
Vizia
RF +
TM
componentlineisaZ-Wave
®
enableddevice.InaZ-Wave
®
network,eachdeviceisdesignedtoactasarouter.Theserouters
willre-transmittheRFsignalfromonedevicetoanotheruntilthe
intendeddeviceisreached.Thisensuresthatthesignalisreceived
byitsintendeddevicebyroutingthesignalaroundobstaclesand
radiodeadspots.TheSceneCapableIncandescentDimmeris
compatiblewithanyZ-Wave
®
enablednetwork,regardlessofthe
manufacturerandcanalsobeusedwithotherdevicesdisplaying
theZ-Wave
®
logo.
CAUTION:
RemembertoexercisegoodcommonsensewhenusingtheTimer
featuresofyourremote,especiallywhenschedulingunattended
devices.Therecanbesomeunexpectedconsequencesifnot
usedwithcare.Forexample,anemptycoffeepotcanberemotely
turnedon.Ifthatshouldhappen,yourcoffeepotcouldbedamaged
fromoverheating.Ifanelectricheateristurnedonbyremote
controlwhileclothingisdrapedoverit,arecouldresult.DO NOT
USEtheremoteforthecontrolofhighpowerheatingappliances
suchasportableheaters.Thisdevicewillnotcontrollightingthatis
usedwithelectroniclow-voltageandhighfrequencypowersupply
transformers,norhighpressuredischargelamps(HIDlighting).
Thisincludesmercury-vapor,sodiumvaporandmetalhalidelamps.
• SoftfadeON/OFF
• Scenecapable
• Twowaycommunication
• RFreliability
• NoNeutralwirerequired
FEATURES
• ON/OFFLEDandBrightness
levelLED
• Easeofinstallation–Nonew
wiring
• CompatiblewithotherZ-Wave
®
enableddevices
Changing the color of your Dimmer:
Yourdevicemayincludecoloroptions.Tochangecolorofthe
face,proceedasfollows:
Line up tabs
and press in
sides one at a
time to attach
Push in
side at tab
to release
Installing Dimmer by itself or with other devices
IfinstallingDimmerinasingledeviceapplication,proceedwiththe
INSTALLING YOUR DIMMERsection.IfinstallingDimmerinamulti-
deviceapplication,proceedasfollows:
MULTI-DEVICE APPLICATION:
Inmulti-dimmerinstallations,thereductionofthedimmer’scapacityis
required.Refertothechartformaximumloadperdimmer.
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Cat. No.
VRI1
Ø
1000W
Single
800W
Two Devices
650W
More than 2 Devices
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Dimmer
Remote (with LEDs)
YL/RD
Red
WH
BK
Black
Black
White
Yellow/
Red
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Additional
Neutral Wire
BK
RD
YL/RD
Matching Dimmer Remote
4
3
1
2
5
Dimmer
Black
Green
Re d
5
2
1
Yellow/Red
4
3
Step 4c
3-Way Wiring with Matching Remote
(w/LEDs) Application:
Strip Gage
(measure bare wire
here or use gage on
back of the dimmer)
5/8”
(1.6 cm)
cut
(if necessary)
Step 3
Preparing and connecting wires:
• Makesurethattheendsofthewiresfromthewall
boxarestraight (cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
• For Single Pole Application, go to Step 4a.
• For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b.
• For 3-Way Matching Remote (with LEDs) Application, go to Step 4c.
NOTE: ThedimmermustbeinstalledinawallboxthathasaLoad
connection.Thematchingremotemustbeinstalledinawallboxwith
aLineHotconnectionandaNeutralconnection.ANeutralwiretothe
matchingremoteneedstobeaddedasshown.
Ifyouareunsureaboutanypartoftheseinstructions,consulta
qualiedelectrician.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotes
cannotexceed300ft.
WIRING MATCHING REMOTE (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchandFirstTravelertoremoteterminalscrewmarked“BK”.
• SecondTravelerwallboxwirefromdimmertoremoteterminal
screwmarked“YL/RD”(note wire color).Thistravelerfromthe
remotemustgototheterminalscrewonthedimmer
marked“YL/RD”.
• LineNeutralwallboxtoremoteterminalscrewmarked“WH”.
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
GreenorbarecopperwireinwallboxtoGreendimmerlead.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchto
Reddimmerlead.
• FirstTravelerLineHottoBlackdimmerlead.
• RemoveRedinsulatinglabelfromYellow/Reddimmerlead.
• SecondTravelerwallboxwire(note color as above)toYellow/Red
dimmerlead.Thistravelerfromthedimmermustgototheterminal
screwontheremotemarked“YL/RD”.
• ProceedtoStep5.
Step 1
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER
atcircuitbreakeror
fuseandtest
thatpowerisoff
beforewiring!
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
Remove all
inner side
sections
Do not
remove
outer side
sections
WIRE NUT / # OF CONDUCTOR COMBINATION CHART
1-#12w/1to3#14,#16or#18
2-#12w/1or2#16or#18
1-#14w/1to4#16or#18
2-#14w/1to3#16or#18
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreendimmerlead.
• LineHotwallboxwiretoBlackdimmerlead.
• LoadwallboxwiretoReddimmerlead.
• Yellow/ReddimmerleadshouldhaveRedinsulationlabelafxed.
NOTE:IfinsulatinglabelisnotafxedtoYellow/Reddimmerlead,
useelectricaltapetocover.
• Proceed to Step 5.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE:WhenusingthecoordinatingremotewithoutLEDs,thedimmercanbe
installedoneithertheLineorLoadsideofthe3-waycircuit.
NOTE: Maximumwirelengthfromdimmertoallinstalledremotescannot
exceed300ft.
GreenorbarecopperwireinwallboxtoGreendimmerlead.
• LineHot(common)wallboxwireidentied(tagged)whenremovingoldswitch
toBlackdimmerlead.
• FirstTravelerwallboxwiretoReddimmerlead(note wire color).Thistraveler
fromthedimmermustgototheterminalscrewontheremotemarked“RD”.
• RemoveRedinsulatinglabelfromYellow/Reddimmerlead.
• SecondTravelerwallboxwiretoYellow/Reddimmerlead(note wire color).
Thistravelerfromthedimmermustgototheterminalscrewontheremote
marked“YL/RD”.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximumwirelengthfromdimmertolastremoteis300ft.
GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchtoterminal
screwmarked“BK”.
• FirstTravelerwallboxwire(note color as above)toterminalscrewmarked
“RD”.ThistravelerfromtheremotemustgototheReddimmerlead.
• SecondTravelerwallboxwire(note color as above)toterminalscrew
marked“YL/RD”.ThistravelerfromtheremotemustgototheYellow/Red
dimmerlead.
• Remoteterminalscrewmarked“WH”shouldhaveWhiteinsulationlabel
afxed.NOTE: Ifinsulatinglabelisnotafxedtoterminalscrewmarked“WH”,
useelectricaltapetocover.
• ProceedtoStep5.
Including Scene Capable Dimmer into
Z-Wave
®
Network:
Restore Power: Restorepoweratcircuitbreakeror
fuse.Installation is complete.
D)ThePrimaryProgrammer/ControllerwillassignanodeIDnumber
(Name)forthismodule.
NOTE: ThisIDnumber(Name)willbestoredinthecontrollerlibrary
tobeusedforfuturereference.
NOTE: Youmayeditthename
ofthisdeviceatthistime.
E) The dimmer is now installed in
the network.
NOTE: Ifadimmerhasbeen
successfullyIncludedinthenetwork
andtheusertriestoIncludeitagain
withoutrstexcludingitfromthe
network,themodulewillretainthe
rstnodeIDithadreceivedand
ignorethesecond.
Testing your Dimmer prior to mounting in
wall box:
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
LevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenetofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchveyearperiodtheproductisreturnedprepaid,withproofof
purchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,
abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandtnessforaparticular
purpose,islimitedtoveyears.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.
• Restorepoweratcircuitbreakerorfuse.
• PresspaduntillocatorlightisOFF.Lights
shouldturnON.IflightsdonotturnON,
presstherighthalfofDIM/BRIGHTbaruntil
thelightsbrighten.
If lights still do not turn ON, refer to the
TROUBLESHOOTING section.
NOTES:
• Ifusinganon-LevitonProgrammer/Controller,
refertotheProgrammer/Controllerinstruction
sheetforIncludingadevice.
• IfusingtheVRCPG'sInstallChecklistfeature,
godirectlytoStepB.
A)IfusingaLevitonZ-Wave
®
Programmer/
Controller,Cat.No.VRCPG,presstheMenu
buttonandscrolldowntoSystemSetup.
PressthecenterbuttontoselectSystem
SetupMenu.ChooseAdvancedSettings.
PressthecenterbuttontoselectNetwork.
B)Whilestandingclosetothemodule(approx.
2-5ft),pressthecenterbuttonto<Include>
deviceinthenetwork.
NOTE:Onlyonedevicemaybeincludedatatime.DO NOTput
multipledevicesintotheInclusionmodeatanytime.
C) WhiletheProgrammer/ControllerisintheInclusionmodeandthe
LocatorLEDisONonthedimmer,pushthepushpadtoturnON
thedimmer.TheProgrammer/Controllerwillverifyinclusionand
thelocatorLEDwillturnOFFonthedimmer.
IfthedimmerisashingAmberwhileintheInclusionmode,the
Programmer/Controllerisstilltryingtocommunicatewiththe
dimmer.Waituntilthedevicestopsashing,thenpresspushpad.
NOTE:IfthelocatorLEDonthedimmerturnssolidRedwhile
including,therehasbeenacommunicationerror.Referto
Troubleshootingsection.
DI-000-VRI10-02A2008©LevitonMfg.Co.,Inc.
ProtectedunderU.S.PatentNumber6,388,399andpatentspending
andlicensedunderU.S.PatentsNumbers5,905,442,and5,982,103
Programmer/Controller
Cat. No. VRCPG
Menu
Button
Center
Button
• Lights Flickering
- Lamphasabadconnection.
- Wiresnotsecuredrmlyunderterminalscrewsofdimmer
and/orremote.
- Localswitch,ON
• Light does not turn ON and Locator LED does not turn ON
- Circuitbreakerorfusehastripped.
- Lampisburnedout.
- LampNeutralconnectionisnotwired.
- Conrmthatthedeviceisbeingsuppliedfroma120V,60HzAC
sourceONLY.
- Conrmthatunitisprogrammedproperly.Repeat“TOINSTALL”
sectiontoverifythatithasbeenincludedintheZ-Wave™
network.
• Intermittent dimmer operation
- Minimumloadisunder40W.
- ConrmthattheLoadbeingcontrolleddoesnotexceedthe
1000Wdimmerlimit.
• Remote does not operate lights
- Ensurethattotalwirelengthdoesnotexceed300ft.
TROUBLESHOOTING
For additional information, contact Leviton’s Techline
at 1-800-824-3005 or visit Leviton’s website at
www.ViziaRFplus.com
NOTE:Thelocatorlightwillilluminatewhen
theloadisintheOFFpositiontofacilitate
accessinthedark.
NOTE:Ifusingthedimmerina3-way
application,thelightswillturnONat
brightnesssetondimmer’sDIM/BRIGHTbar.
Thelightingcanbecontrolledfromeitherthe
dimmerortheremotelocation.
Push Pad (Default settings)
Turn ON from OFF position:
Tap–LightsturnONtopresetlevel.
PressandHold–LightsturnONtofullbright.
Turn OFF from ON position:
Tap–LightsturnOFF.
LED Brightness
Display
DIM/BRIGHT
Bar
Push
Pad
Locator
Light
OPERATION
Installationmaynowbecompleted
bytighteningmountingscrewsinto
wallbox.Attachwallplate.
Dimmer Mounting:
TURN OFF POWER AT
CIRCUIT BREAKER
OR FUSE.
Step 7
Step 6
NOTE: ItisveryimportanttoaccuratelyExcludedevicesfromthe
networkwhenmovingorremovingadevicefromaZ-Wave
®
network.
ThisensuresthatallinformationhasbeenremovedfromyourPrimary
Programmer/Controller’sinformationtableandisnotcountedontobea
partofthemeshnetwork.
A)IfusingaLevitonZ-Wave
®
Programmer/Controller,Cat.No.VRCPG,
presstheMenubuttonandscrolldowntoSystemSetup.Press
thecenterbuttontoselectSystemSetupMenu.ChooseAdvanced
Settings.PressthecenterbuttontoselectNetwork.
B) Whilestandingclosetothedimmer,pressthecenterbuttonto
<Exclude>devicefromthenetwork.WhiletheProgrammer/Controller
isintheExclusionmodeandthelocatorLEDisONonthedimmer,
pressthepushpadonthedimmer.TheProgrammer/Controllerwill
verifyExclusionandthelocatorLEDwillturnOFFonthedimmer.
IfthedimmerisashingAmberwhileintheExlusionmode,the
Programmer/Controllerisstilltryingtocommunicatewiththedimmer.
Waituntilthedevicestopsashing,thenpressthepushpad.
Factory Default:
Ifyourdimmerisnotresponding,oryouareunabletocontrolitafter
youhavetriedtoInclude/Excludeitmultipletimes,itmaybenecessary
toresetthedimmertoitsoriginalfactorysettings.Toaccomplishthis,
proceedasfollows:
• Onthedimmer,engageheair-gapswitch(refer to Operation
section)andwait5seconds.Presspushpadbackintoframeand
holdpushpaduntilthelocatorLEDturnsAmberandthenturns
Red.Thedimmerisnowreset.Oncethedimmerisreset,itwillbe
necessarytoRe-Includeittoanetworkbeforeitcanbeused.
CAUTION:SETTINGADEVICETOAFACTORYDEFAULTDOES
NOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSION
PROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICE
FROMTHEPRIMARYCONTROLLER’SINFORMATIONTABLE.
FAILURETODOSOMAYRESULTINASYSTEMTHATISSLOWTO
RESPOND,ORMAYFAILTORESPONDTOSOMEDEVICES.
Step 9
Excluding Dimmer from Network:
Step 8
NOTE: Dresswireswithabend
asshownindiagraminorderto
relievestresswhenmounting
device.
Positionallwirestoprovideroominoutlet
wallboxfordevice.
• Ensurethattheword“TOP”isfacingup
ondevicestrap.
• Partiallyscrewinmountingscrewsinwall
boxmountingholes.
Step 5
A-2) TheLocatorLEDwillblink2timespersecondtoindicatethe
deviceisinProgramModeA-2, Minimum Brightness Level.
TochangetheMinimum Brightness Levelfrom1-50%,use
theDIM/BRIGHTBar.Thelightoutputwillreecttheminimum
brightnesslevelselected.BytappingthePushPadthissettingwill
automaticallybesavedandthedevicewilladvancetothenext
programmingmode,A-3.
A-3) TheLocatorLEDwillblink3timespersecondtoindicateProgram
Mode A-3, Preset ON Level.TochangethecurrentPreset ON
Levelfrom1-100%,usetheDIM/BRIGHTBar.Ifthisfeatureis
notdesired,pressandholdthelefthalfoftheDIM/BRIGHTBar
(
v
)
untilnoLEDislit(defaultsetting).BytappingthePushPad
thissettingwillautomaticallybesavedandthedevicewill
exit
ProgrammingModeA.
Program Mode B
To enter Program Mode B:
PressandholdthePushPadandthenthelefthalfofthe
DIM/BRIGHTBar(
v
)for5secondsuntiltheLocatorLEDandrightmost
LED(LED7)begintoblink.
B-1) UponreleasingthePushPadandthelefthalfofthe
DIM/BRIGHTBar(
v
),theLocatorLEDwillcontinuetoblinkonce
persecondindicatinghedimmerisinProgramModeB-1, ON
Fade Rate.TochangetheON Fade Rate,usetheDIM/BRIGHT
BartomovetheLEDtothedesiredpresetlevelaccordingtoChart
B.BytappingthePushPadthissettingwillautomaticallybesaved
andthedevicewilladvancetothenextprogrammingmode,B-2.
B-2) TheLocatorLEDwillblink2timespersecondtoindicateProgram
Mode B-2, OFF Fade Rate.TochangetheOFF Fade Rate,use
theDIM/BRIGHTBartomovetheLEDtothedesiredpresetlevel
according to Chart B.BytappingthePushPadthissettingwill
automaticallybesavedandthedevicewilladvancetothenext
programmingmode,B-3.
LED Brightness
Display
1 2 3 4 5 6 7
Definition of A Modes
A-1) EnergySave:Setsthemaximumbrightnesslevelforenergy
savings.
A-2) MinimumBrightnessLevel:Setstheminimumdimminglevel.
A-3) PresetONLevel:Setstheturnonbrightnesslevelregardlessof
theprevioussetlightlevel(formerlyDimLock).
Definition of B Modes
B-1) ONFadeRate:Setstheamountoftimeinsecondsittakesthe
lightstoturnONtomaximumbrightness.
B-2) OFFFadeRate:Setstheamountoftimeinsecondsittakesthe
lightstoturnOFFfrommaximumbrightness.
B-3) LEDOptions:SetsthetimeperiodinsecondstheLocatorLED
andBrightnessdisplaywillstayonbeforeextinguishing.
Definition of LEDs
LeftmostLED=LED1
RightmostLED=LED7
NOTES:
• Thedevicewillexitprogramming
modeafter3minutesofinactivity.
• Pressingthepushpadatanytime
duringprogrammingwilladvancethe
devicetothenextprogrammingmode.
ADVANCED PROGRAMMING FEATURES
Program Mode A
To enter Program Mode A:
PressandholdthePushPadandthentherighthalfofthe
DIM/BRIGHTBar
(
^
)
for5secondsuntiltheLocatorLEDand
leftmostLED(LED1)begintoblink.
A-1) UponreleasingthePushPadandtherighthalfofthe
DIM/BRIGHTBar
(
^
)
,theLocatorLEDwillcontinuetoblink
oncepersecondandtherightmostLEDwillilluminateto
displaythedeviceisinProgramModeA-1, Energy Save.The
defaultenergysavemodeis100%i.e.fullbright.Tochange
the Energy Savelevel,usetheDIM/BRIGHTBartomove
thecorrespondingLEDtothedesireddiscretepresetlevel
according to Chart A.BytappingthePushPadthissettingwill
automaticallybesavedandthedevicewilladvancetothenext
programmingmode,A-2.
B-3)
TheLocatorLEDwillblink3timespersecondtoindicateProgram
Mode B-3, LED Options.TochangetheLED Optionssettings,
usetheDIM/BRIGHTBartomovetheLEDtothedesiredpreset
settingaccordingtotheChart B-3.BytappingthePushPad
thissettingwillautomaticallybesavedandthedevicewillexit
Programming
ModeB.
LED
LED 1
LED 2 (Default)
LED 3
LED 4
LED 5
LED 6
LED 7
FADE ON
0 seconds (instant)
0.5 seconds
1.5 seconds
3.0 seconds
6.0 seconds
10 seconds
25 seconds
0 seconds (instant)
0.5 seconds
1.5 seconds
3.0 seconds
6.0 seconds
10 seconds
25 seconds
FADE OFF
Chart B
When indicator
light is at LED #
7
6
5
4
3
2
1
Light output is at
100%
97%
95%
90%
85%
80%
75%
Energy consumption
savings amounts to
0%
5%
8%
11%
14%
17%
20%
Chart A
Chart B-3
LED
LED 1
LED 2
LED 3
LED 4
LED 5
LED 6
LED 7
LOCATOR LED TIMEOUT
Active
Active
Active
Active
Turns off 5 sec. after use
Turns off 5 sec. after use
Turns off 5 sec. after use
LED BRIGHTNESS DISPLAY OPTIONS
Active
Turns off 5 sec. after use
Active
Turns off 5 sec. after use
LED Bar active
LED Bar turns off 5 sec. after use
LED Bar turns off 5 sec. after use
VRCPG
Programmer/
Controller
NOTE: Remotemustbeinclose
proximitytodimmerwhenincluding
innetwork.
DIM/BRIGHT Bar
BRIGHTEN:
PressrighthalfofDIM/BRIGHTBar–Lightsbrightentodesiredlevel.
DIM:
PresslefthalfofDIM/BRIGHTBar–Lightsdimtodesiredlevel.
IfyoucontinuetoholdthelowerhalfoftheDIM/BRIGHTBar,thelights
willDIMtominimumlevelandthenturnOFF.
NOTE:WhenlightsareOFFyoucanchangethe
lightlevelthatthelightswillturnONtousingthe
DIM/BRIGHTBar.
Ifthereisapoweroutage,whenthepoweris
restoredthelightswillreturntothelastsetting
beforethepowerinterruption.
Air-Gap Switch:Onthedimmeronly,engage
theair-gapswitchbygentlypressingthe
topofthepushpaduntilthebottomlifts
completelyoutoftheframeandaclickis
heard (refer to Figure).LEDswillturnOFF.
Thiswillcutpowertothexturetoreplace
thebulb.Afterservicingiscomplete,pushthe
pushpadbackfornormaloperation.
Cleaning: Cleanwithadampcloth.DO NOT
usechemicalcleaners.
Gently press top
of push pad
Thisequipmenthasbeentestedandfoundtocomplywiththelimits
foraClassBDigitalDevice,pursuanttoPart15oftheFCCRules.
Theselimitsaredesignedtoprovidereasonableprotectionagainst
harmfulinterferenceinaresidentialinstallation.Thisequipment
generates,uses,andcanradiateradiofrequencyenergyand,ifnot
installedandusedinaccordancewiththeinstructions,maycause
harmfulinterferencetoradiocommunications.However,thereisno
guaranteethatinterferencewillnotoccurinaparticularinstallation.If
thisequipmentdoescauseharmfulinterferencetoradioortelevision
reception,whichcanbedeterminedbyturningtheequipmentOFF
andON,theuserisencouragedtotrytocorrecttheinterferenceby
oneormoreofthefollowingmeasures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweentheequipmentandthe
receiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfrom
thattowhichthereceiverisconnected.
• Consultthedealeroranexperiencedradio/tvtechnicianfor
help.
FCC COMPLIANCE STATEMENT
  • Page 1 1
  • Page 2 2

Z-Wave VRI10-1LZ Installation guide

Category
Dimmers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI