- NOTICE -
This Manual is prepared for the use of trained Hobart Service
Technicians and should not be used by those not properly
qualified.
This manual is not intended to be all encompassing. If you have
not attended a Hobart Service School for this product, you should
read, in its entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Hobart Service Technician.
The reproduction, transfer, sale or other use of this manual,
without the express written consent of Hobart, is prohibited.
This manual has been provided to you by ITW Food Equipment
Group LLC ("ITW FEG") without charge and remains the property
of ITW FEG, and by accepting this manual you agree that you will
return it to ITW FEG promptly upon its request for such return at
any time in the future.
SERVICE MANUAL
A product of Vulcan-Hart 3600 North Point Blvd Baltimore, MD 21222
F24682 Rev. G (1219)
TABLE OF CONTENTS
SERVICE UPDATES ....................................................................................... 4
SERVICE UPDATES - VC4G / VC6G ................................................................... 4
TIS DOCUMENT LIST - VC4G AND VC6G .............................................................. 4
GENERAL .................................................................................................. 6
INTRODUCTION ....................................................................................... 6
INSTALLATION ........................................................................................ 6
OPERATION ........................................................................................... 6
CLEANING ............................................................................................. 6
REFERENCE INFORMATION .......................................................................... 6
LUBRICATION ......................................................................................... 6
SPECIFICATIONS ...................................................................................... 6
TOOLS ................................................................................................. 7
REMOVAL AND REPLACEMENT OF PARTS ............................................................... 8
COVERS AND PANELS ................................................................................ 8
TOP FRONT COVER ............................................................................... 8
BOTTOM FRONT COVER .......................................................................... 8
CONTROL PANEL ................................................................................. 8
RIGHT SIDE PANEL ................................................................................ 8
CONTROL PANEL COMPONENTS ..................................................................... 9
COMPONENT PANEL COMPONENTS ................................................................ 10
TEMPERATURE PROBE (VC4GD/6GD) ............................................................... 11
GAS BURNER ........................................................................................ 12
GAS ORIFICE ......................................................................................... 13
GAS SOLENOID VALVE .............................................................................. 14
IGNITION CONTROL MODULE ....................................................................... 15
SPARK IGNITER AND FLAME SENSE ................................................................ 16
BLOWER AND MOTOR ENDING AT SERIAL NUMBER 481913935 .................................... 17
BLOWER AND MOTOR STARTING AT SERIAL NUMBER 481913936 ................................. 19
OVEN DOORS (SIMULTANEOUS DOORS) ENDING AT SERIAL NUMBER 481907145 ................ 20
ASSEMBLY REMOVAL ........................................................................... 20
DISASSEMBLY ................................................................................... 21
OVEN DOORS (SIMULTANEOUS DOORS) STARTING AT SERIAL NUMBER 481907146 .............. 21
OVEN DOORS AND BEARINGS (INDEPENDENT DOORS) ENDING AT SERIAL
NUMBER 481907145 .............................................................................. 22
DOOR CATCH BALL ASSEMBLY (INDEPENDENT DOORS) ........................................... 23
OVEN DOORS (INDEPENDENT DOORS) STARTING AT SERIAL NUMBER 481907146 ............... 23
ROLLER LATCH ASSEMBLY (INDEPENDENT DOORS) ............................................... 24
DOOR WINDOW ...................................................................................... 24
DOOR SWITCH ....................................................................................... 25
MECHANICAL KX THERMOSTAT (VC4GS/6GS) ...................................................... 25
HIGH LIMIT THERMOSTAT ........................................................................... 26
INTERIOR LIGHTS (REAR MOUNTED, ROUND) ...................................................... 26
INTERIOR LIGHTS (SIDE MOUNTED, SQUARE) ...................................................... 27
COOLING FAN ........................................................................................ 29
SERVICE PROCEDURES AND ADJUSTMENTS ........................................................... 30
SOLID STATE TEMPERATURE CONTROL CALIBRATION (VC4GD/6GD) ............................. 30
MECHANICAL THERMOSTAT CALIBRATION (VC4GS/6GS) .......................................... 32
SOLID STATE TEMPERATURE CONTROL TEST (VC4GD/6GD) ...................................... 33
TEMPERATURE PROBE TEST (VC4GD/6GD) ......................................................... 34
GAS PRESSURE ADJUSTMENT (UNITS UP TO FEBRUARY 2015) ................................... 34
GAS VALVE PRESSURE CHECK (UNITS AFTER FEBRUARY 2015) .................................. 36
VERIFICATION OF SPARK AT IGNITOR .............................................................. 37
DOOR SWITCH ADJUSTMENT ....................................................................... 37
BLOWER ADJUSTMENT .............................................................................. 38
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS
F24682 Rev. G (1219) Page 2 of 93
DOOR ADJUSTMENT ................................................................................. 38
DOOR STRIKE ADJUSTMENT (INDEPENDENT DOORS) ............................................. 39
DOOR CATCH BALL ADJUSTMENT (INDEPENDENT DOORS) ........................................ 40
DOOR CHAIN ADJUSTMENT (SIMULTANEOUS DOORS) ............................................. 41
INTRODUCTION .................................................................................. 41
PROCEDURE ..................................................................................... 41
COMPUTER CONTROL (VC4GC/VC6GC) ............................................................. 42
OPERATION ...................................................................................... 42
SETUP MODE .................................................................................... 42
PROBE TEST ..................................................................................... 43
SOLID STATE RELAY TEST ...................................................................... 43
COMPUTER CONTROL CALIBRATION (VC4GC/VC6GC) ............................................. 43
FLAME SENSE CURRENT TEST ...................................................................... 44
SERVICE PROGRAMMING AND TESTING ............................................................ 47
ELECTRICAL OPERATION ................................................................................ 51
COMPONENT FUNCTION ............................................................................ 51
COMPONENT LOCATION ............................................................................. 52
SEQUENCE OF OPERATION ......................................................................... 57
VC4GS, VC6GS WITH ROAST & HOLD OPTION (MECHANICAL KX THERMOSTAT) .............. 57
VC4GD, VC6GD WITH ROAST & HOLD OPTION (SOLID STATE
TEMPERATURE CONTROL) .................................................................. 62
VC4GC, VC6GC (ROAST & HOLD STANDARD ON COMPUTER MODEL) ......................... 67
COOL DOWN CYCLE (COMPUTER CONTROL MODEL) .......................................... 69
SCHEMATICS ............................................................................................ 70
VC4GS, VC6GS MECHANICAL (KX) CONTROLS ..................................................... 70
VC4GS, VC6GS MECHANICAL (KX) CONTROLS, ROAST & HOLD OPTION ........................... 71
VC4GD, VC6GD SOLID STATE TEMPERATURE CONTROL .......................................... 72
VC4GD, VC6GD SOLID STATE TEMPERATURE CONTROL, ROAST & HOLD OPTION ................ 74
VC4GC, VC6GC COMPUTER CONTROL (ROAST & HOLD STANDARD) .............................. 75
WIRING DIAGRAMS ...................................................................................... 77
VC4GS, VC6GS MECHANICAL (KX) CONTROLS ..................................................... 77
VC4GS, VC6GS MECHANICAL (KX) CONTROLS, ROAST & HOLD OPTION ........................... 79
VC4GD, VC6GD SOLID STATE TEMPERATURE CONTROL .......................................... 81
VC4GD, VC6GD SOLID STATE TEMPERATURE CONTROL, ROAST & HOLD OPTION ................ 84
VC4GC, VC6GC COMPUTER CONTROL (ROAST & HOLD STANDARD) .............................. 86
TROUBLESHOOTING ..................................................................................... 89
ALL MODELS ......................................................................................... 89
IGNITION MODULE DIAGNOSTICS ................................................................... 90
COMPUTER CONTROL MODELS ONLY .............................................................. 91
ERROR CODES .................................................................................. 92
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS
© VULCAN 2019
Page 3 of 93 F24682 Rev. G (1219)
SERVICE UPDATES
SERVICE UPDATES - VC4G / VC6G
June 2019
Added SERVICE PROGRAMMING AND
TESTING.
October 2018
Updated and Added Data Modules
BLOWER AND MOTOR Starting at Serial
Number 481913936
OVEN DOORS (SIMULTANEOUS DOORS)
Starting at Serial Number 481907146
OVEN DOORS (INDEPENDENT DOORS)
Starting at Serial Number 481907146
INTERIOR LIGHTS (Side Mounted, Square)
INTERIOR LIGHTS (Rear Mounted, Round)
DOOR ADJUSTMENT
COMPONENT LOCATION
FLAME SENSE CURRENT TEST
VC4GS, VC6GS Mechanical (KX) Controls,
Roast & Hold Option
VC4GD, VC6GD Solid State Temperature
Control
VC4GC, VC6GC Computer Control (Roast &
Hold Standard)
IGNITION MODULE DIAGNOSTICS
TIS DOCUMENT LIST - VC4G AND VC6G
SERVICE TAB
Document Title Document Type
VC4G and VC6G Service Manual Service Manual
Watlow Controller Replaced By NCC Controller Technical Service Bulletin (TSB)
SERVICE TAB (Multimedia)
Document Title Document Type
3700 Oven Quick Start Guide Operator
Repair Flood-Damaged Food Equipment Misc
Convection Oven Computer Control Guide Operator
VC4GD, VC4GC, VC6GD, VC6GC, HGC5, HGC5X,
HGC5D, HGC5DX, & WKGD Installation and Operation
I &O Manual
Fundamentals of Gas Service Instructions
TSB 1037A Hobart to Vulcan "Common" Model Cross
Reference List
Technical Service Bulletin (TSB)
Technical Service Bulletin (TSB)
Rating Plate Locations on Current Vulcan-Hart/Wolf
Range Equipment
Service Bulletin
PARTS TAB
Document Title Document Type
Part Catalog for VC4G and VC6G Parts Catalog
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - SERVICE UPDATES
F24682 Rev. G (1219) Page 4 of 93
DIAGRAMS TAB
Document Title Document Type
HGC5, DGC5, VC4G, WKGD Series Wiring Diagram
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - SERVICE UPDATES
Page 5 of 93 F24682 Rev. G (1219)
GENERAL
INTRODUCTION
Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model
unless the picture or illustration needs to be model specific.
Models
MODEL
FEATURES OPTIONS
CAVITY
DEPTH
TEMPERTURE
CONTROL
DOORS
(50/50)
COOK
TIMER
COOK
TIMER
OR
HOLD
TIMER
COOK
&
HOLD
BLOWER
208/240/60/1
VC4GS 26.5" Mechanical (KX)
Independent
1
2
1-Hour Dial 5-Hour Dial Optional Optional
VC6GS 30.5" Mechanical (KX)
Independent
1
2
1-Hour Dial 5-Hour Dial Optional Optional
VC4GD 26.5" Solid State
Independent
1
3
1-Hour Dial 5-Hour Dial Optional Optional
VC6GD 30.5" Solid State
Independent
1
3
1-Hour Dial 5-Hour Dial Optional Optional
VC4GC 26.5" Computer
Independent
1
3
24-Hour
Digital
Built in Built in Optional
VC6GC 30.5" Computer
Independent
1
3
24-Hour
Digital
Built in Built in Optional
1
Simultaneous doors are optional (with or w/o window).
2
Stainless steel doors w/o window (standard).
3
Stainless steel doors with window (standard).
INSTALLATION
Refer to the Instructions Manual for detailed
installation instructions on single or stacked ovens.
OPERATION
Refer to the Instructions Manual for specific operating
instructions.
CLEANING
Refer to the Instructions Manual for specific cleaning
instructions.
REFERENCE INFORMATION
Refer to the Parts Catalog F43031 for parts
information.
LUBRICATION
Cavity blower motor has sealed bearings and
requires no additional lubrication.
Huskey™ TF-1000 grease or equivalent high
temperature Teflon grease.
SPECIFICATIONS
Electrical
Voltage - 120/60/1
Amps - 8.0 Amps
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - GENERAL
F24682 Rev. G (1219) Page 6 of 93
Input BTU Rating
Natural Gas - 44,000 BTU input at 3.5 in. W.C.
Units after Serial Number Break (VC4GD 481835388,
VC6GD 481835406, VC4GD 541077665) Natural
Gas - 50,000 BTU input at 5.0 in. W.C.
Propane Gas - 44,000 BTU input at 10.0 in. W.C.
Units after Serial Number Break (VC4GD 481835394
& 541077965, VC6GD 481835429) Propane Gas -
50,000 BTU input at 10.0 in. W.C.
Gas Line Pressures
Natural - Recommend (in. W.C.) 7.0, Min 5.0
Natural - Recommend (in W.C.) 8.0, Min 6.0 for Units
after Serial Number Break (VC4GD 481835388,
VC6GD 481835406, VC4GD 541077665)
Propane - Recommend (in. W.C.) 11.0, Min 11.0 (All
Propane Units)
Maximum 14.0 in. W.C. (Nat. or Prop.)
TOOLS
Standard
Standard set of hand tools
VOM with ability to measure micro amp current
VOM with minimum of NFPA-70E CAT III 600V,
UL/CSA/TUV listed. Sensitivity of at least 20,000
ohms per volt. Meter leads must also be rated at
CAT III 600V.
Gear Puller to remove blower
Special
Temperature tester (thermocouple type)
Manometer
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - GENERAL
Page 7 of 93 F24682 Rev. G (1219)
REMOVAL AND REPLACEMENT OF PARTS
COVERS AND PANELS
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
SHUT OFF THE GAS BEFORE SERVICING THE
UNIT.
Top Front Cover
1. The top front cover is secured with four (4)
screws, two on each side of cover. Remove these
screws then remove the cover from the oven.
Fig. 1
2. Reverse the procedure to install.
Bottom Front Cover
1. The bottom front cover is secured with four (4)
screws, two on each side of cover. Remove these
screws then remove the cover from the oven.
Fig. 2
2. Reverse the procedure to install.
Control Panel
1. Remove three (3) screws on the right side which
secure the control panel then pull the panel away
from the oven.
Fig. 3
NOTE: If the oven has a mechanical (KX type)
thermostat, it must be removed from the control panel
first, before removing the control panel.
2. Disconnect the temperature probe leads from the
solid state temperature control.
3. Unplug the wire harness connector to the control
panel components.
4. Reverse the procedure to install.
Right Side Panel
1. Remove the screws which secure the right side
of the top front cover, bottom front cover and
control panel.
2. Remove the remaining six screws securing the
right side panel.
Fig. 4
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F24682 Rev. G (1219) Page 8 of 93
3. Pull the right side panel out at the bottom then
down to remove.
4. Reverse the procedure to install.
CONTROL PANEL COMPONENTS
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Removable Components Procedure
1. Remove the Control Panel.
2. Remove the component being replaced.
3. Reverse the procedure to install the replacement
component, then check oven for proper
operation.
Fig. 5
Fig. 6
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
Page 9 of 93 F24682 Rev. G (1219)
Fig. 7
COMPONENT PANEL
COMPONENTS
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Removable Components Procedure
1. Remove the Right Side Panel.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the Control
Panel.
2. Disconnect the wire leads to the component
being replaced.
3. Remove the component.
4. Reverse the procedure to install the replacement
component and check oven for proper operation.
Fig. 8
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F24682 Rev. G (1219) Page 10 of 93
Fig. 9
Fig. 10
TEMPERATURE PROBE (VC4GD/
6GD)
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
1. Remove the Right Side Panel.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the Control
Panel.
2. Disconnect the probe leads from the solid state
temperature control.
3. Remove the racks and right rack support.
4. Remove the probe guard.
1st Generation Production Guard Shown
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
Page 11 of 93 F24682 Rev. G (1219)
Fig. 11
5. Remove probe by pushing it through the oven
wall and into the control panel area.
Fig. 12
NOTE: The hole in the oven cavity wall does not line
up straight with the oven cavity outer shell, therefore
the probe must be removed at an angle.
6. Reverse the procedure to install the replacement
probe.
When installing a 2nd generation guard, the tip of the
probe should be located near the center of the large
cutout, as shown in Fig. 13. The end with the wire
attached should be protected by the guard. It is
possible to damage the probe/wire with force from a
tray if probe is not protected properly.
Fig. 13
7. Adjust the temperature control as outlined under
SOLID STATE TEMPERATURE CONTROL
CALIBRATION (VC4GD/6GD).
GAS BURNER
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
SHUT OFF THE GAS BEFORE SERVICING THE
UNIT.
1. Remove the BOTTOM FRONT COVER.
2. Disconnect the ignition cable and the flame
sense lead wire.
Fig. 14
3. Remove the bolts securing the gas manifold to
the oven and place the manifold to the side.
Fig. 15
4. Remove the screws securing the burner cover
then lift out.
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F24682 Rev. G (1219) Page 12 of 93
Fig. 16
5. Grasp the burner and lift out.
Fig. 17
6. Reverse procedure to install the replacement
burner.
NOTE: Ensure that burner positioning bracket (U
shaped end) is inserted into slot at the rear of the
burner chamber.
NOTE: When installing current production burner
covers:
Lay cover flat over burner with openings
aligned behind ignitor.
Push burner into unit and flip cover 90° up
and align mounting holes.
CURRENT PRODUCTION UNIT SHOWN
7. Check for proper operation.
GAS ORIFICE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
SHUT OFF THE GAS BEFORE SERVICING THE
UNIT.
1. Remove the Bottom Front Cover.
2. Remove the bolts securing the gas manifold to
the oven and place the manifold to the side.
Fig. 19
3. Remove the gas orifice from the spud on the
manifold and replace with the correct orifice for
the given altitude.
Fig. 20
4. Reverse procedure to install and check for proper
operation.
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
Page 13 of 93 F24682 Rev. G (1219)
GAS SOLENOID VALVE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
SHUT OFF THE GAS BEFORE SERVICING THE
UNIT.
1. Remove the CONTROL PANEL and the RIGHT
SIDE PANEL.
NOTE: if right side panel is not accessible, this
component can be serviced by removing the
CONTROL PANEL.
2. Disconnect the lead wires.
3. Disconnect the compression fittings to the valve.
FIRST GENERATION UNIT SHOWN (Before April
2005)
SECOND GENERATION UNIT SHOWN (After April
2005 thru February 2015)
CURRENT PRODUCTION SHOWN (After February
2015)
4. Loosen the bolts securing the valve and bracket
assembly then remove the screws securing the
valve to the bracket.
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F24682 Rev. G (1219) Page 14 of 93
FIRST GENERATION UNIT SHOWN (Before April
2005)
SECOND GENERATION UNIT SHOWN (After April
2005 thru February 2015)
CURRENT PRODUCTION SHOWN (After February
2015)
5. Reverse the procedure to install the replacement
gas valve.
NOTE: Clean the pipe threads and apply pipe joint
compound to threads. Any pipe joint compound used,
must be resistant to the action of propane gases.
All gas joints disturbed during servicing must be
checked for leaks. Check with a soap and water
solution (bubbles). Do not use an open flame.
6. Verify gas pressure as outlined under GAS
PRESSURE ADJUSTMENT (for units before
February 2015) and GAS VALVE PRESSURE
CHECK (for units after February 2015) and check
for proper operation.
IGNITION CONTROL MODULE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
SHUT OFF THE GAS BEFORE SERVICING THE
UNIT.
1. Remove the Right Side Panel.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the Control
Panel.
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
Page 15 of 93 F24682 Rev. G (1219)
2. Loosen the screws securing the mounting
bracket to the component panel and remove the
bracket.
Fig. 27
NOTE: When replacing ignition cable, order service
kit which includes ignition cable and insulation cap for
the coil.
3. Disconnect the lead wires and igniter cable from
the ignition module board.
Fig. 28
4. Remove the ignition module board from the
mounting bracket.
5. Reverse the procedure to install the replacement
ignition module board.
SPARK IGNITER AND FLAME
SENSE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
SHUT OFF THE GAS BEFORE SERVICING THE
UNIT.
1. Remove the gas burner as outlined under GAS
BURNER.
2. Remove the screws securing the ignitor and
flame sense to burner then remove the
assembly.
Fig. 29
3. Reverse the procedure to install the assembly
and check for proper operation.
NOTE: Check to ensure the spark gap distance is
approximately 1/8". If the gap appears to be excessive
or poor sparking is occurring then adjust.
PREVOUS PRODUCTION SHOWN
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F24682 Rev. G (1219) Page 16 of 93
CURRENT PRODUCTION SHOWN
BLOWER AND MOTOR Ending at
Serial Number 481913935
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
SHUT OFF THE GAS BEFORE SERVICING THE
UNIT.
1. Take out the racks and rack supports.
2. Remove screws securing the “snorkel” and
remove the snorkel.
Fig. 32
3. Remove screws securing baffle panel and
remove the panel.
Fig. 33
4. If replacing:
A. Blower Only - Loosen set screws on blower
hub and using a bearing puller, remove
blower from motor shaft.
1) Reverse procedure to install and adjust
blower position as outlined under
BLOWER ADJUSTMENT.
B. Motor - perform step 4A and continue
procedure.
5. Remove the screws securing the air baffle to the
rear wall at the lower right hand corner.
Fig. 34
6. Remove the nuts that secure the motor mounting
plate to the rear wall.
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
Page 17 of 93 F24682 Rev. G (1219)
Fig. 35
7. Place a piece of cardboard on the bottom of the
oven cavity to protect its surface from any
damage during motor assembly removal.
8. Pull the motor assembly into the oven cavity and
place it on the cardboard.
9. Remove the junction box cover from the motor,
disconnect lead wires and remove the conduit.
10. Remove motor mounting bolts and flat washers
then lift the motor from the mounting plate.
11. Position the replacement motor on the motor
mounting plate and install mounting bolts and
washers. Hand tighten mounting bolts only.
12. Reconnect lead wires at the motor, replace
conduit and junction box cover.
NOTE: Check data plate on motor for wiring
schematic. The motor must rotate clockwise when
viewed from the shaft end.
Fig. 36
13. Slide blower onto motor shaft until hub is flush
with end of shaft then tighten set screws.
14. Adjust motor position until blower is parallel to
motor mounting plate as outlined under
BLOWER ADJUSTMENT.
15. Position motor mounting plate on the rear wall
and secure with nuts and washers.
16. Replace the baffle panel and “snorkel”.
17. Replace the air baffle on the rear wall at the lower
right hand corner.
18. Remove cardboard from the bottom of the oven
cavity.
19. Install rack guides and racks.
20. Check oven for proper operation.
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F24682 Rev. G (1219) Page 18 of 93
BLOWER AND MOTOR Starting at
Serial Number 481913936
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
1. Remove RIGHT SIDE PANEL(S).
2. Disconnect motor harness (1, Fig. 37).
Fig. 37
3. Pinch cord grip together to remove from rear
panel.
Fig. 38
4. Push motor wiring harness/cord out hole in rear
panel.
5. Remove racks.
6. Remove screws securing "snorkel" and remove
snorkel.
Fig. 39
7. Remove blower baffle screws (2, Fig. 40) if
applicable.
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
Page 19 of 93 F24682 Rev. G (1219)
Fig. 40
8. Remove motor mounting plate nuts (1, Fig. 40).
9. Place a piece of cardboard on bottom of oven
cavity to protect its surface from any damage
during motor assembly removal.
10. Pull motor assembly into oven cavity and place
on cardboard.
11. Remove motor mounting bolts and washers and
lift motor off mounting plate.
Fig. 41
NOTE: Motor graphics are shown with motor
installed.
12. Remove drip pan from motor and install onto
replacement motor.
Fig. 42
13. Reverse procedure to install.
14. Verify operation.
OVEN DOORS (SIMULTANEOUS
DOORS) Ending at Serial Number
481907145
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Assembly Removal
1. Remove the Top Front Cover and Bottom Front
Cover.
2. Remove the door switch lever.
Fig. 43
3. Remove the top bearing retainers and top
bearings.
VC4G & VC6G SERIES FULL SIZE CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F24682 Rev. G (1219) Page 20 of 93
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93

Vulcan VC4GC User manual

Category
Cookers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI