NDICLED3 UNIVERSAL 3-POSITION LED FIXTURE
DL/ADJ/WW FOR TRIMMED & TRIMLESS CEILING APPLICATIONS
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
NOTE: FIXTURE INSTALLATION CONSISTS OF (1) HOUSING, (1) OPTIC, & (1) TRIM ASSEMBLY
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FIRE RISK: open top cover to remove foam packaging material before installation
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable parts inside.
WARNING: Suitable for wet locations where the ambient temperature is 0°C minimum, +40°C maximum.
WARNING: Suitable for installation in Non-Accessible and Accessible Ceilings.
WARNING: Suitable for installation in Insulated Ceilings & Non-Insulated Ceilings.
HOUSING ROUGHIN INSTALLATION
1. Nailer bars are provided for use with wood joist
installations. Insert through Nailer Bar Slots in
Buttery Brackets and secure accordingly. C-Channels
are optionally available, consult factory. Consult local
building codes for nal support of xture.
2. Remove appropriate Knock out on Junction box. Press
Clip to remove the Junction Box Cover.
3. Feed the supply wires through Knock out hole and
connect to the driver. Re-install Junction Box Cover. See
wiring section for details.
4. The xture can be adjusted to dierent heights above
the Ceiling surface. For height adjustment, loosen the
Wing Nut and slide the Buttery Bracket. If necessary
remove the Wing Nut and insert in screw in dierent
hole provided on the Buttery Bracket. (Fig: 2)
5. Adjust both the Buttery Brackets such that the Plaster
Collar of Rough-In Section is ush with the nished
Ceiling surface. Tighten the Wing nuts.
Rough-in Section
(Bottom of the
Rough-in Section
to be ush with
nished ceiling)
Buttery Brackets
Knock Out
Clip
Junction
Box Cover
Fig: 1
Buttery
Bracket
Wing Nut
Fig: 2
Nailer Bar Slot
RAB NDIC3 xtures are IC rated allowing xtures to be
completely covered with insulation and also complies with
ASTM E283 Energy Code Standard for minimum air leakage.
MOUNTING BARS
A
A
B B
C C
D D
4
1234
23
R
AB
SCALE 0.500
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
27" C-CHANNEL
MATERIAL: PART No.: DRAWING NAME:
22 GA EC STL 15154-27 15154-27 C-CHANNEL
DATE: REV DATE: REV
3-9-12
DRAWN BY:
DH
SCALE
1/2
SHEET:
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
REV DESCRIPTION DATE
1
QUOTATION DRAWING
11-14-12
SCALE 0.500
.500
[12,7]
1.500
[38,1]
27.000
[685,8]
.201 (2)
[5,11]
.250
[6,35]
.220
[5,59]
A
A
B B
C C
D D
4
1234
23
R
AB
SCALE 0.500
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
27" C-CHANNEL
MATERIAL: PART No.: DRAWING NAME:
22 GA EC STL 15154-27 15154-27 C-CHANNEL
DATE: REV DATE: REV
3-9-12
DRAWN BY:
DH
SCALE
1/2
SHEET:
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
REV DESCRIPTION DATE
1
QUOTATION DRAWING
11-14-12
SCALE 0.500
.500
[12,7]
1.500
[38,1]
27.000
[685,8]
.201 (2)
[5,11]
.250
[6,35]
.220
[5,59]
Nailer Bar
13” adjustable to 24”
(provided with xture)
C Channel-27”
(order Cat #: C-Chan 27)
Available upon request
C Channel-51”
(order Cat #: C-Chan 51)
Available upon request
NDICLED3R
Cut-Out Diameter: 3.5”
Ceiling
NDICLED3S
Cut-Out: 3.5” x 3.5”
Plaster Collar
NDICLED3 UNIVERSAL 3-POSITION LED FIXTURE
DL/ADJ/WW FOR TRIMMED & TRIMLESS CEILING APPLICATIONS
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
OPTIC HOLDER INSTALLATION (Fig. 3)
(3) INTERCHANGEABLE OPTIC ASSEMBLIES ARE AVAILABLE:
Optic guide
Downlight trims: 80° or 50°
Adjustable trims: 40° or 20°
Wallwasher trims: ONLY 50°
1. To install Optic Holder, align each outer Lock Tab (3) to
the three open slots (Lock Tab Openings) on housing LED
Heatsink Assembly as shown with 3 bold arrows
2. Push up/in and twist clockwise until Optic Holder is secure
3. LED Heatsink Assembly may begin to rotate, but will come
to a stop as Optic Holder is twisted into correct position
Positioning, Aiming, and Locking
NDICLED3 ships preset in standard Downlight Position (Fig.
4). To make adjustments, a screwdriver with a maximum shaft
diameter of 3/16” is required.
1. Insert screwdriver into vertical lock screw Snoot and loosen
screw until Optic Assembly begins to move
2. To set in Wallwasher Position (Fig. 5), locate Optic
Assembly over yellow highlighted indent and lock into
place
To set Adjustable Position (Fig. 6), move Optic Assembly
into desired position and lock into place
3. To ensure horizontal axis locking, see label in ceiling collar
indicating lock location. Rotate Optic Assembly with
screwdriver into desired position and tighten with thumb.
80° OPTIC ASSY
40°/50° OPTIC ASSY 20° OPTIC ASSY
LED
Heatsink
Assembly
Lock Tab
(1 of 3)
Optic Holder
Snoot
Downlight Lock Indent Optic Assembly
Downlight Position
Wallwash Position Adjustable Position
Downlight Lock Indent Wallwasher Lock Indent
Snoot
Optic Assembly
Snoot
Downlight Lock Indent Wallwasher Lock Indent
Fig. 3
Fig. 4
Fig. 5 Fig. 6
Lock Tab
Opening
(1 of 3)
NDICLED3 UNIVERSAL 3-POSITION LED FIXTURE
DL/ADJ/WW FOR TRIMMED & TRIMLESS CEILING APPLICATIONS
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TRIM CONE INSTALLTION
TRIM: FLANGED TYPE
For Wallwasher and Adjustable Trims Only. (Fig. 7)
1. Position Trim Cone in center of xture opening
2. Visually locate red Trim Alignment Arrow on xture and
red Trim Aligment Label on Trim Cone
3. Making sure the Arrow and Label face eachother, push
Trim Cone up into xture opening until Trim Flange is
ush to Sheet Rock
TRIMLESS: SHEETROCK ONLY
Requires Spackle Flange Accessory TSF3R or TSF3S. (Fig. 8 &9)
1. Place Spackle Flange on Ceiling and align opening with
Ceiling cutout and xture opening
2. Carefully mark the screw hole openings on Ceiling and
remove Spackle Flange
3. Use a 3/16” drill bit to drill Ceiling
NOTE: DO NOT DRILL HOLES DEEPER THAN THE CEILING
THICKNESS
4. Install 8x7/8” Wall Anchors (supplied) into Ceiling
5. Re-install Spackle Flange with Countersunk Screws
(supplied)
6. Tape and spackle over Spackle Flange accordingly.
DO NOT ALLOW ANY JOINT COMPOUND OR DEBRIS INSIDE
FRAME OPENING. ALWAYS KEEP DEBRIS COVER IN PLACE
UNTIL TRIM INSTALLATION.
7. Position Trim Cone in center of xture opening
8. Visually locate red Trim Alignment Arrow on xture and
red Trim Aligment Label on Trim Cone
9. Making sure the Arrow and Label face eachother, push
Trim Cone up into xture opening until Trim is ush with
Ceiling
Fig. 7
Trim Cone
Trim
Alignment
Label
Trim
Alignment
Arrow
Trim Flange
Fig. 9
8x3/4”
Countersunk
Screws4)
Trim
Spackle Frame
Wall Anchor (4)
Sheet Rock
Ceiling
Wall Anchors (4)
Fig. 8
Spackle Flange
Ceiling
8x3/4”
Countersunk
Screws4)
Sheet Rock
NDICLED3 UNIVERSAL 3-POSITION LED FIXTURE
DL/ADJ/WW FOR TRIMMED & TRIMLESS CEILING APPLICATIONS
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TROUBLESHOOTING
1. Check that the line voltage at the xture is correct. Refer to
wiring directions.
2. Is the xture grounded properly?
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to
touch. Do not clean or maintain while xture is energized.
1. Do not open xture to clean the LED. Do not touch
the LED.
2. Do not touch reector, lens or trim cone.
3. Do not clean any xture surface with wood base cleaning
material such as paper towels or tissues. Only use microber
cleaning cloth.
Fig: 10
Fig: 11
Fig: 12
WIRING
RISK OF FIRE. Universal voltage driver permits operation at
120V thru 277V, 50 or 60 Hz.
For Non-Dimming, Electronic Low Voltage (ELV) and Triac
Dimming follow the wiring directions in Fig. 10.
1. Connect the GROUND wire from xture to supply ground
2. Connect the black xture lead to the (+) LINE supply lead
3. Connect the white xture lead to the (-) COMMON supply
lead
For 0-10V dimming (Fig. 11).
Lutron L3D Hi-Lume series drivers work with Lutron 3-Wire
Control (Fig. 12)
Note: See www.lutron.com for complete instructions and
functional compatibility of Lutron drivers with Lutron or
other control systems/ dimmers.
Note: These instructions do not cover all details or variations in
equipment nor do they provide for every possible situation during
installation, operation or maintenance. RAB cannot troubleshoot Lutron
systems and have provided only basic information. See
www.lutron.com for complete instructions and functional compatibility
of Lutron Drivers with Lutron or other Control systems/dimmers.
NDICLED3 UNIVERSAL 3-POSITION LED FIXTURE
DL/ADJ/WW FOR TRIMMED & TRIMLESS CEILING APPLICATIONS
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
Easy Answers
rabweb.com
Visit our website for product info
Tech Help Line
Call our experts - 888 722-1000
e-mail
Answered promptly - sales@rabweb.com
Free Lighting Layouts
Answered online or by request
© 2017 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
DIMENSIONAL DRAWINGS
NDICLED3 IN 0417
NDICLED3R
12.19"
7.75"
11.59"
6.0"
1.0"
3.46"
11.59"
8.86"
11.59"
8.86"
3.47"x3.47"
6.0"
1.0"
11.59"
12.19"
7.75"
NDICLED3S
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

RAB Lighting NDICLED3R-25LYNHC-TL Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI