Identification:
Technical Bulletin:
Date:
Issuer:
Factory:
D06
CG2007-17 (page 1 of 2), 2
nd
ed.
19 November 2007
R. Sartor (DWS Customer Support)
CGX – Dishwashing – Pordenone (I)
Subject
Low Boiler Temperature in WTM & RTC/WTC
Model
Modular Rack Type range (Electrolux WTM series) and Compact Rack Type
range (Electrolux WTC series and Zanussi RTC series).
Problem
Low boiler temperature.
Reason
Water flow, temperature gap and power are in relation as follow (unless water
turbulences in the boiler that may delay the water temperature increase):
[]
[]
[]
186,4min/
60
.
∗
∗
=°
lWaterFlow
kWpower
Cgaptemp
or
[]
]
]
60
.186,4min/ CgaptemplWaterFlow
kWpower
°∗∗
=
Therefore reasons of low boiler temperature can be:
1. Higher rinse water flow than it should be (either 4 l/min or 5 l/min according
to the model)
2. Lower inlet water temperature than it’s required (50°C for models without
ESD, 15°C for models with ESD)
3. Lower actual boiler power than it should be because:
• Not working boiler heater
• Lower voltage supply than 400V (208V/240V for US range versions). In
fact the actual power is:
)
PowerRate
ageSupplyActualVolt
rActualPowe ∗=
2
2
400
For instance, a 12 kW boiler heater supplied with 380V instead of 400V has
an actual heating power of 10,8 kW (10% less than the nominal power rate).
Since September we have marked the screw to adjust the water flow and
removed the knob (in order to minimize change in the water flow rate by
unauthorized people, e.g. chemical engineers).
Action in
field
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380636
++39 0434 385646
Share more of our thinking at www.electrolux.com