Champion 2000 Datasheet

Category
Juice makers
Type
Datasheet

This manual is also suitable for

(1M) 10/10 Printed in U.S.A.
IDH2000 High Temperature
Door-type
Dishwashing Machine
IDH2000
IDH2000 DOORTYPE
STANDARD FEATURES
NEW Exclusive Built-in booster configured
for both 40° and 70° Rise
NEW Exclusive Field convertible to single or
three phase, 208 or 240 volt, corner or straight
through operation
NEW Exclusive in field convertible to corner
or straight through operation
Rinse Sentry ensures 180°F final rinse
Auto start starts unit when doors are closed
High temperature
Single point connection
High efficiency 1 HP pump
55 racks per hour
Self draining pump
Automatic tank fill
Detergent/chemical connections
Interchangeable upper and lower arm
Top mounted splash proof controls
Automatic drain valve
Vent fan control
Low water tank heat protection
Fresh water rinse
Overflow machine
SPECIFIER STATEMENT
Specified unit will be Champion model IDH2000,
high temperature door-type dishwashing machine.
Features top mounted splash proof controls, Rinse Sentry,
Auto start, interchangeable stainless steel wash and rinse
arms, 55 racks/hr., .90 US gals/rack.
1 year parts and labor warranty.
Champion Industries, Inc.
3765 Champion Blvd, Winston-Salem, NC 27105
Tel: 336/661-1556 Fax: 336/661-1979
www.championindustries.com
Project
Item No.
Quantity
OPTIONS & ACCESSORIES
Drain Tempering Kit
Side Panels
Pressure reducing valve (unmounted)
DH2000 High Temperature
Door-type
Dishwashing Machine
IDH2000
IDH2000 DOORTYPE
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., 3765 Champion Blvd, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
Shipping weight crated: 300 lbs.
Dimensions shown in inches [milineters]
Front View
Door Clearance
Side View
Typical Table Construction
SPECIFICATIONS
Capacities
Racks per hr. (NSF rated) 55
Wash tank (gal.) 9.5
Motor horsepower
1 HP
Water consumption
Gal. per hr. (max. use) 49.5
Gal. per rack .9
Temperature °F
Wash 150
Rinse 180
Heating
Tank heat, electric 5.2 kW
Electric Booster 7.5 kW
Time cycle in seconds
Wash 40
Dwell 1
Rinse 12
Sanitary Dwell 7
Total cycle 60
Warning: Plumbing, electrical connections should be
made by qualified personnel who will observe all the
applicable plumbing, sanitary and safety codes and the
National Electrical Code.
Plan View
Straight Through
Operation
Utilities
1 Water
3/4" NPT Flow pressure 20-25 PSI
Hot water 140°F (82°C)
2 Electrical 40°/70° Booster
40°/ 70°F rise booster
208-220/50/ 1 & 3 (See Box)
3 Drain
2" OD Connection
Gravity flow,
15 GRM max flow
TYPICAL TABLE CONSTRUCTION
[762]
30"
1-1/2" [32] Roll
1-1/8"
[29]
7-1/4"
[184]
21-3/8"
[543]
6" [152]
oor clearance
0
13-1/8 [333]
33-3/4" [857]
59-1/8" [1502]
26-1/8" [663]
30-7/8" [784]
26" [660]
67" [1702]
76" [1930]
Top clearance
Open doors
17-3/8"
[438]
Door
Clearance
65-1/4"
[1657]
67"
0
6"
38-1/2"
59-1/8"
18-3/4"
6-1/2" [165]
13-1/8" [333]
3-1/4" [83]
18-1/16"
[472]
13-1/8" [333]
17-5/8" [440]
18-3/4" [476]
4-1/2"
[114]
19-1/8"
[486]
28.1°
REF
20-3/16"
[513]
Inside
Rails
19-1/8" [486]
13-1/8"
[333]
18-1/8"
[460]
3-3/16"
[81]
3
3
1
2
3
1
2
3
1
3
1
2
1
3
2
2
6" [152]
oor clearance
0
13-1/8 [333]
33-3/4" [857]
59-1/8" [1502]
26-1/8" [663]
30-7/8" [784]
26" [660]
67" [1702]
76" [1930]
Top clearance
Open doors
17-3/8"
[438]
Door
Clearance
65-1/4"
[1657]
67"
0
6"
38-1/2"
59-1/8"
18-3/4"
6-1/2" [165]
13-1/8" [333]
3-1/4" [83]
18-1/16"
[472]
13-1/8" [333]
17-5/8" [440]
18-3/4" [476]
4-1/2"
[114]
19-1/8"
[486]
28.1°
REF
20-3/16"
[513]
Inside
Rails
19-1/8" [486]
13-1/8"
[333]
18-1/8"
[460]
3-3/16"
[81]
3
3
1
2
3
1
2
3
1
3
1
2
1
3
2
2
6" [152]
oor clearance
0
13-1/8 [333]
33-3/4" [857]
59-1/8" [1502]
26-1/8" [663]
30-7/8" [784]
26" [660]
67" [1702]
76" [1930]
T
op clearance
Open doors
17-3/8"
[438]
Door
Clearance
65-1/4"
[1657]
67"
0
6"
38-1/2"
59-1/8"
18-3/4"
6-1/2" [165]
13-1/8" [333]
3-1/4" [83]
18-1/16"
[472]
13-1/8" [333]
17-5/8" [440]
18-3/4" [476]
4-1/2"
[114]
19-1/8"
[486]
28.1°
REF
20-3/16"
[513]
Inside
Rails
19-1/8" [486]
13-1/8"
[333]
18-1/8"
[460]
3-3/16"
[81]
3
3
1
2
3
1
2
3
1
3
1
2
1
3
2
2
6" [152]
oor clearance
0
13-1/8 [333]
33-3/4" [857]
59-1/8" [1502]
26-1/8" [663]
30-7/8" [784]
26" [660]
67" [1702]
76" [1930]
Top clearance
Open doors
17-3/8"
[438]
Door
Clearance
65-1/4"
[1657]
67"
0
6"
38-1/2"
59-1/8"
18-3/4"
6-1/2" [165]
13-1/8" [333]
3-1/4" [83]
18-1/16"
[472]
13-1/8" [333]
17-5/8" [440]
18-3/4" [476]
4-1/2"
[114]
19-1/8"
[486]
28.1°
REF
20-3/16"
[513]
Inside
Rails
19-1/8" [486]
13-1/8"
[333]
18-1/8"
[460]
3-3/16"
[81]
3
3
1
2
3
1
2
3
1
3
1
2
1
3
2
2
6" [152]
oor clearance
0
13-1/8 [333]
33-3/4" [857]
59-1/8" [1502]
26-1/8" [663]
30-7/8" [784]
26" [660]
67" [1702]
76" [1930]
Top clearance
Open doors
17-3/8"
[438]
Door
Clearance
65-1/4"
[1657]
67"
0
6"
38-1/2"
59-1/8"
18-3/4"
6-1/2" [165]
13-1/8" [333]
3-1/4" [83]
18-1/16"
[472]
13-1/8" [333]
17-5/8" [440]
18-3/4" [476]
4-1/2"
[114]
19-1/8"
[486]
28.1°
REF
20-3/16"
[513]
Inside
Rails
19-1/8" [486]
13-1/8"
[333]
18-1/8"
[460]
3-3/16"
[81]
3
3
1
2
3
1
2
3
1
3
1
2
1
3
2
2
Electric 40°/70° Rise Booster
Voltage
Rated
Amps
Maximum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/50/1 65 80 80
240/50/1 75 80 80
208/50/3 40 50 50
240/50/3 45 50 50
  • Page 1 1
  • Page 2 2

Champion 2000 Datasheet

Category
Juice makers
Type
Datasheet
This manual is also suitable for