246653-YTG-E-0108
Johnson Controls Unitary Products 9
NOMENCLATURE
123 4
CONTROL
ADDITIONAL
D = SYNTHESYS CONTROL
CONFIGURATION
VOLTAGE
E = SYNTHESYS CONTROL,
OPTIONS
2 = 208/230-60
DISC., 110V OUTLET
Cu/Cu Condenser Coil
3 = 380-60
F = SYNTHESYS, DISC.
Cu/Cu Evaporator Coil
4 = 460-60
Exhaust VFD (Customer)
5 = 575-60
H = SIMPLICITY CONTROL
(see notes 3 & 7)
7 = 380/415-50
I = SIMPLICITY CONTROL, DISC
NOTES:
110V OUTLET
1. 108KW not available with 208/230V.
J = SIMPLICITY CONTROL,
* Premium Cabinet (6 doors)
2. Standard efficiency motor meets Canadian
DISC, NO 110V OUTLET
* Standard Cabinet (4 doors)
ID BLOWER
(See note 4)
minimum efficiency regulations mandated
K = SIMPLICITY CONTROL W/MODLINC
* Drain Pan - powder coat
A = a, f, i L = d, g, j W = d, e, j
in Canadian Energy Efficiency Regulations.
L = SIMPLICITY CONTROL W/ MODLINC
* Drain Pan - stainless steel
B = a, g, i M = b, f, i X = d, f, h
3. (VFD-CUSTOMER) = Wired for VFD
DISC, 110V OUTLET
C = a, f, j N = b, f, j Y = b, e, h
only; VFD will be customer supplied and
M = SIMPLICITY CONTROL W/MODLINC
*
must
make selections
D = a, g, j O = b, g, i Z = b, e, i
field installed. If VFD Exh is also
DISC, NO 110V OUTLET
N = YCCS CONTROL
P = YCCS CONTROL W/DISC., 110V OUTLET
Q = YCCS ZONING CONTROL
R = YCCS ZONING CONTROL W/DISC.,
110V OUTLET
S = YCCS - VAV CONTROL
T = YCCS - VAV CONTROL W/DISC.,
110V OUTLET
in these options
E = a, e, h P = b, g, j 2 = b, e, j
specified, it will also be cust supplied.
F = a, e, i Q = c, f, i 3 = b, f, h
4. VAV ID Blower requires hot gas bypass .
G = a, e, j R = c, f, j 4 = c, e, h
5. Power exhaust and barometric relief not
H = a, f, h S = c, g, i 6 = c, e, i
available in end return configuration.
CONFIGURATION
I = d, f, i T = c, g, j 7 = c, e, j
6. Air foil fan available on cooling only.
A = 1,2 1 - BOTTOM RETURN
J = d, f, j U = d, e, h 8 = c, f, h
9 = d, g, h
Contact engineering for
B = 1,4 2 - BOTTOM SUPPLY
K = d, g, i V = d, e, i
air foil applications.
C = 1,5
3 - END RETURN
(5)
Air Volume
7. Only available with Hi EFF motors
ECONOMIZER
D = 3,2 4 - REAR SUPPLY
a = CV
A = DUAL ENTH Low leak type
E = 3,4 5 - FRONT SUPPLY
b = VAV (VFD-FACTORY INSTALLED)
B = SINGLE ENTH Low leak type
F = 3,5
c = BYPASS FACTORY VFD
C = DRY BULB ENTH Low leak type
FRONT SUPPLY - COOLING ONLY
d = VAV (VFD-CUSTOMER)
(3)
D = MANUAL Low leak (Not w/PE)
HOT WATER, STEAM & ELECTRIC HEAT -
Fan (See note 6)
E = NONE
BOTTOM SUPPLY ONLY
e = FORWARD CURVE FAN Class I
B = 2,3,5,7 M = 1,3,6,8 X = 2,4,0,7
F = DUAL ENTH Std type
GAS HEAT - BOTTOM OR REAR SUPPLY ONLY
f = FORWARD CURVE FAN Class II
C = 1,4,5,7 N = 2,3,6,8 Y = 1,3,9,8
G = SINGLE ENTH Std type
g = AIR FOIL FAN [always Class II]
D = 2,4,5,7 O = 1,4,6,8 Z = 2,3,9,8
H = DRY BULB Std type
HEAT SOURCE
E = 1,3,6,7 P = 2,4,6,8 2 = 2,4,9,8
N = NATURAL GAS
Blower Mount
F = 2,3,6,7 Q = 1,3,9,7 3 = 1,3,0,8
S = NATURAL GAS, SS HEAT EXCHANGER
h = Neoprene
G = 1,4,6,7 R = 2,3,9,7 4 = 2,3,0,8
EXHAUST
(See note 5)
D = NATURAL GAS, MODULATING HEAT*
i = 1 inch deflection spring
H = 2,4,6,7 S = 1,4,9,7 5 = 1,4,0,8
A = BARO J = 2, 5 S = A, 3
T = NATURAL GAS, MODULATING HEAT, SS *
j = 2 inch deflection spring
I = 1,3,5,8 T = 2,4,9,7 6 = 2,4,0,8
B = 1, 3 K = 2, 6 T = A, 4
HEAT EXCHANGE
J = 2,3,5,8 U = 1,3,0,7 7 = 1,4,9,8
C = 1, 4 L = 2, 7 U = A, 5
E = ELECTRIC HEAT
K = 1,4,5,8 V = 2,3,0,7
D = 1, 5 M = 2, 8 V = A, 6
C = COOLING ONLY
9 = Non-Std
E = 1, 6 N = NONE W = A, 7
W = HOT WATER COIL
ID MOTOR
(See note 2)
F = 1, 7 O = 1, 9 X = A, 8
X = STEAM COIL
1 = 10 HP STD
Condenser Coil Head Press. Ctrl.
G = 1, 8 P = 1, 0 Y = A, 9
2 = 15 HP STD
1 = STANDARD 7 = YES
H = 2, 3 Q = 2, 9 Z = A, 0
3 = 20 HP STD
2 = TECHNICOAT 8 = NO
I = 2, 4 R = 2, 0 2 = 8,000 CFM ERV
HEAT CAPACITY
4 = 25 HP STD (Except 25T)
Piping
(See note 4)
3 = 13,000 CFM ERV
3 = 267 MBH
5 = 10 HI-EFF
3 = STANDARD 4 = HOT GAS BYPASS
5 = 533 MBH
6 = 15 HI-EFF
Evaporator Coil
9 = Non Std Config
8 = 800 MBH (40T ONLY)
7 = 20 HI-EFF
5 = STANDARD
Power Exhaust
4 = 40 KW
8 = 25 HI-EFF (Except 25T)
6 = HI-CAP (30T/40T R22 ONLY)
1 = MODULATING DAMPERS A = VFD MODULATING
MOTOR
8 = 80 KW
9 = 7.5 HP STD (25T Only)
9 = STD W/TECHNICOAT
2 = NON-MOD. (ON/OFF)
1 = 108 KW
(1)
0 = 7.5 HI-EFF (25T Only)
0 = HI-CAP W/T-COAT (30T/40T R22)
0 (ZERO) NO HEAT
Motor
1 = 1 ROW
0 = 5 HP HI-EFF (25T Only) 9 = 5 HP (25T Only)
2 = 2 ROW
3 = 7.5 HP 6 = 7.5 HP HI-EFF
1 = 1 ROW
4 = 10 HP 7 = 10 HP HI-EFF
5 = 15 HP (Except 25 Ton) 8 = 15 HP HI-EFF (Except 25 Ton)
Config
A
13
D
14
3
3
N
5
A
4
PACKAGE
3
6
4
7
FILTERS
C
12
B
8
1
9
A
10
A
11
GENERATION
3
2
Y
1
Y = York Brand R22
A = STAND.
B = 65%
C = 95%
D = 2" HI-EFF
REFRIGERATION
(30T/40T)
3 = 30 TON
4 = 40 TON
2 = 25 TON
BASIC UNIT
Class I blower is limited to 15HP in 25/30Ton
Class I blower is limited to 20HP in 40Ton
Class II blowers are not HP limited