Moyer Diebel MD66, MD-66, MD44 Datasheet

  • Hello! I am an AI chatbot trained to assist you with the Moyer Diebel MD66 Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Printed in U.S.A.
Moyer Diebel – USA
3765 Champion Boulevard, Winston-Salem, NC 27105 Tel: 336/661-1992 Fax: 336/661-1979 800/228-8350
www.moyerdiebel.com
STANDARD FEATURES
Chemical connections
Built in diagnostics
Energy Sentinel
Vent cowls
216 racks per hour
144 gallons per hour/.66 gallons per rack
Anti-jam conveyor system
Single point electrical connection
Single point water connection
2 Hp wash pump
Exhaust fan control
Vent fan interlock connection
Table limit switch connection
MD44 is field convertible left to right or right to left
Convenient top mounted controls
Drain is a manual ball valve
MODEL MD44/MD66 RACK CONVEYOR DISHWASHER
OPTIONS & ACCESSORIES
: 40
°
rise (16kW) Electric Booster
: 70
°
rise (27kW) Electric Booster
: Direction of Operation
: Right to Left
: Left to Right
: Table limit switch
: 22" Prewash (2Hp prewash pump)
: Vent Extenders (set of 2)
: Drain Water Tempering Kit
: Voltage 480/60/3
: Pressure Reducing Valve (unmounted)
(standard with booster)
SPECIFIER STATEMENT
Specified unit will be Moyer Diebel MD44 rack conveyor
dishwashing machine. MD66 rack conveyor dishwashing
machine includes 22" Prewash.
Features include: chemical connections, vent fan interlock and
table limit switch connections, energy sentinel, extended vent
cowls, built in diagnostics and anti-jam conveyor drive system.
1 year parts and labor warranty.
Project
Item No.
Quantity
MD44/MD66
High Temperature Rack Conveyor
Dishwashing Machine
MD66 includes 22" Prewash
MD44 shown
MD44
High Temperature Rack Conveyor
Dishwashing Machine
Side View
Front View
Right to Left
Front View
Left to Right
Plan View
Door
4" [102]
48-1/4" [1,226]
VENT STACK
c
L
DISTANCE
20" [508]
23-7/8" [606]
44" [1,118]
MD44-LR MD44-RL
2 18A 8B
5
2
5
8B
2
5
1
5
1
1
8A
16" [406]25" [635]
1-7/8" [48]
7-3/8" [187]
4-3/4" [121]
5-1/2" [140]
12-3/8" [314]
2-1/8"[54]
2-1/8"[54]
21-3/4" [552]
Opening
2-1/2" [64]
20" [508]
20" [508]
Inside Track
2-1/2" [64]
6" [152] Nominal
Wall Clearance
28-1/2" [724]
8" [203] 8" [203]
44" [1,118]
8" [203] 8" [203]
5-7/8" [149]3" [76]
5-7/8" [149]3" [76]
26" [660]
Door
26" [660]
Door
4-1/8" [105] 4-1/8" [105]
34" [864]
Load
Height
20" [508]
Clearance
7" [178]
12-7/8" [327]
Plumbing
Clearance
7-1/8" [181]
89" [2,261]
Removal
Height
82" [2,083]
Door Open
Height
58-3/8" [1,483]
Machine
Height
Door
4" [102]
48-1/4" [1,226]
VENT STACK
c
L
DISTANCE
20" [508]
23-7/8" [606]
44" [1,118]
MD44-LR MD44-RL
2 18A 8B
5
2
5
8B
2
5
1
5
1
1
8A
16" [406]25" [635]
1-7/8" [48]
7-3/8" [187]
4-3/4" [121]
5-1/2" [140]
12-3/8" [314]
2-1/8"[54]
2-1/8"[54]
21-3/4" [552]
Opening
2-1/2" [64]
20" [508]
20" [508]
Inside Track
2-1/2" [64]
6" [152] Nominal
Wall Clearance
28-1/2" [724]
8" [203] 8" [203]
44" [1,118]
8" [203] 8" [203]
5-7/8" [149]3" [76]5-7/8" [149]3" [76]
26" [660]
Door
26" [660]
Door
4-1/8" [105] 4-1/8" [105]
34" [864]
Load
Height
20" [508]
Clearance
7" [178]
12-7/8" [327]
Plumbing
Clearance
7-1/8" [181]
89" [2,261]
Removal
Height
82" [2,083]
Door Open
Height
58-3/8" [1,483]
Machine
Height
Door
4" [102]
48-1/4" [1,226]
VENT STACK
c
L
DISTANCE
20" [508]
23-7/8" [606]
44" [1,118]
MD44-LR MD44-RL
2 18A 8B
5
2
5
8B
2
5
1
5
1
1
8A
16" [406]25" [635]
1-7/8" [48]
7-3/8" [187]
4-3/4" [121]
5-1/2" [140]
12-3/8" [314]
2-1/8"[54]
2-1/8"[54]
21-3/4" [552]
Opening
2-1/2" [64]
20" [508]
20" [508]
Inside Track
2-1/2" [64]
6" [152] Nominal
Wall Clearance
28-1/2" [724]
8" [203] 8" [203]
44" [1,118]
8" [203] 8" [203]
5-7/8" [149]3" [76]
5-7/8" [149]3" [76]
26" [660]
Door
26" [660]
Door
4-1/8" [105] 4-1/8" [105]
34" [864]
Load
Height
20" [508]
Clearance
7" [178]
12-7/8" [327]
Plumbing
Clearance
7-1/8" [181]
89" [2,261]
Removal
Height
82" [2,083]
Door Open
Height
58-3/8" [1,483]
Machine
Height
Door
4" [102]
48-1/4" [1,226]
VENT STACK
c
L
DISTANCE
20" [508]
23-7/8" [606]
44" [1,118]
MD44-LR MD44-RL
2 18A 8B
5
2
5
8B
2
5
1
5
1
1
8A
16" [406]25" [635]
1-7/8" [48]
7-3/8" [187]
4-3/4" [121]
5-1/2" [140]
12-3/8" [314]
2-1/8"[54]
2-1/8"[54]
21-3/4" [552]
Opening
2-1/2" [64]
20" [508]
20" [508]
Inside Track
2-1/2" [64]
6" [152] Nominal
Wall Clearance
28-1/2" [724]
8" [203] 8" [203]
44" [1,118]
8" [203] 8" [203]
5-7/8" [149]3" [76]5-7/8" [149]3" [76]
26" [660]
Door
26" [660]
Door
4-1/8" [105] 4-1/8" [105]
34" [864]
Load
Height
20" [508]
Clearance
7" [178]
12-7/8" [327]
Plumbing
Clearance
7-1/8" [181]
89" [2,261]
Removal
Height
82" [2,083]
Door Open
Height
58-3/8" [1,483]
Machine
Height
Due to an ongoing value analysis program at Moyer Diebel, specifications contained in this catalog are subject to change without notice.
3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1992 • Fax: 336/661-1979 • www.moyerdiebel.com
Dimensions shown in inches and [millimeters] Shipping weight crated
: 600 lbs. [272 kg]
MODEL MD44 RACK CONVEYOR DISHWASHER
MD66
High Temperature Rack Conveyor
Dishwashing Machine
Side View
Front View
Right to Left
Front View
Left to Right
Plan View
Due to an ongoing value analysis program at Moyer Diebel, specifications contained in this catalog are subject to change without notice.
3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1992 • Fax: 336/661-1979 • www.moyerdiebel.com
Dimensions shown in inches and [millimeters]Shipping weight crated
: 800 lbs. [363 kg]
MODEL MD44 RACK CONVEYOR DISHWASHER
8" [203]
66" [1,676]
66" [1,676]
8" [203]
8" [203]
8" [203]
5-7/8" [149]
5-7/8" [149]
3" [76]
3" [76]
4-1/8" [105] 4-1/8" [105]
34" [864]
Load
Height
20" [508]
Clearance
16" [406]
25" [635]
1-7/8" [48] 7-3/8" [187]
4-3/4" [121]
5-1/2" [140]
7" [178]
12-7/8" [327]
Plumbing
Clearance
7-1/8" [181]
89" [2,261]
Door
Removal
Height
82" [2,083]
Door Open
Height
58-3/8" [1,483]
Machine
Height
34-3/8" [873]
2-1/8"[54] 2-1/8"[54]
70-1/4" [1,784]
VENT STACK DISTANCE
21-3/4" [552]
Opening
2-1/2" [64]
20" [508]
Inside Track
2-1/2" [64]
6" [152] Nominal
Wall Clearance
28-1/2" [724]
59-1/8" [1,502]
12-3/8" [314] 29-3/8" [746]
26" [660]
Door
26" [660]
Door
15" [381]
Door
15" [381]
Door
8A
2 1
5
MD66-LR MD66-RL
8B
8B
8A
5
2
1
1
2
1
1
5
2
2
c
L
8" [203]
66" [1,676] 66" [1,676]
8" [203]
8" [203]
8" [203]
5-7/8" [149]
5-7/8" [149]
3" [76]
3" [76]
4-1/8" [105] 4-1/8" [105]
34" [864]
Load
Height
20" [508]
Clearance
16" [406]
25" [635]
1-7/8" [48] 7-3/8" [187]
4-3/4" [121]
5-1/2" [140]
7" [178]
12-7/8" [327]
Plumbing
Clearance
7-1/8" [181]
89" [2,261]
Door
Removal
Height
82" [2,083]
Door Open
Height
58-3/8" [1,483]
Machine
Height
34-3/8" [873]
2-1/8"[54] 2-1/8"[54]
70-1/4" [1,784]
VENT STACK DISTANCE
21-3/4" [552]
Opening
2-1/2" [64]
20" [508]
Inside Track
2-1/2" [64]
6" [152] Nominal
Wall Clearance
28-1/2" [724]
59-1/8" [1,502]
12-3/8" [314] 29-3/8" [746]
26" [660]
Door
26" [660]
Door
15" [381]
Door
15" [381]
Door
8A
2 1
5
MD66-LR MD66-RL
8B
8B
8A
5
2
1
1
2
1
1
5
2
2
c
L
8" [203]
66" [1,676]
66" [1,676]
8" [203]
8" [203]
8" [203]
5-7/8" [149]
5-7/8" [149]
3" [76]
3" [76]
4-1/8" [105] 4-1/8" [105]
34" [864]
Load
Height
20" [508]
Clearance
16" [406]
25" [635]
1-7/8" [48] 7-3/8" [187]
4-3/4" [121]
5-1/2" [140]
7" [178]
12-7/8" [327]
Plumbing
Clearance
7-1/8" [181]
89" [2,261]
Door
Removal
Height
82" [2,083]
Door Open
Height
58-3/8" [1,483]
Machine
Height
34-3/8" [873]
2-1/8"[54] 2-1/8"[54]
70-1/4" [1,784]
VENT STACK DISTANCE
21-3/4" [552]
Opening
2-1/2" [64]
20" [508]
Inside Track
2-1/2" [64]
6" [152] Nominal
Wall Clearance
28-1/2" [724]
59-1/8" [1,502]
12-3/8" [314] 29-3/8" [746]
26" [660]
Door
26" [660]
Door
15" [381]
Door
15" [381]
Door
8A
2 1
5
MD66-LR MD66-RL
8B
8B
8A
5
2
1
1
2
1
1
5
2
2
c
L
8" [203]
66" [1,676] 66" [1,676]
8" [203]
8" [203]
8" [203]
5-7/8" [149]
5-7/8" [149]
3" [76]
3" [76]
4-1/8" [105] 4-1/8" [105]
34" [864]
Load
Height
20" [508]
Clearance
16" [406]
25" [635]
1-7/8" [48] 7-3/8" [187]
4-3/4" [121]
5-1/2" [140]
7" [178]
12-7/8" [327]
Plumbing
Clearance
7-1/8" [181]
89" [2,261]
Door
Removal
Height
82" [2,083]
Door Open
Height
58-3/8" [1,483]
Machine
Height
34-3/8" [873]
2-1/8"[54] 2-1/8"[54]
70-1/4" [1,784]
VENT STACK DISTANCE
21-3/4" [552]
Opening
2-1/2" [64]
20" [508]
Inside Track
2-1/2" [64]
6" [152] Nominal
Wall Clearance
28-1/2" [724]
59-1/8" [1,502]
12-3/8" [314] 29-3/8" [746]
26" [660]
Door
26" [660]
Door
15" [381]
Door
15" [381]
Door
8A
2 1
5
MD66-LR MD66-RL
8B
8B
8A
5
2
1
1
2
1
1
5
2
2
c
L
(1M) 4/10
MD44/MD66
High Temperature Rack Conveyor
Dishwashing Machine
MODEL MD44/MD66 RACK CONVEYOR DISHWASHER
Utilities
1
Electrical
Machine and booster
2
Hot water
Main connection 3/4" NPT
5
Drain Connection
1-1/2" NPT
8
Vent Stack Connection
A.
Load end 150 CFM @ 1/4" static pressure
B. Unload end 400 CFM @ 1/4" static pressure
Warning: Plumbing and electrical connections
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary and
safety codes.
SPECIFICATIONS
Capacity
Racks per hr. (NSF rated) 216
Conveyor speed (ft/min) 6.0
Motor Horsepower
Wash 2
Prewash (optional) 2
Water Consumption
Per hr. (max. use) 144 US gal
Per rack .67 US gal
Heating
Tank heat, electric (kW) 15
Electric booster
(kW supplied for 40° F rise) 16
Electric booster
(kW supplied for 70° F rise) 27
MD44 with 70° F Rise (27kW) Booster
Elec.
Specs.
Rate
Amps
Maximum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3 128 150 150
240/60/3 113 125 125
480/60/3 57 70 70
7 F Rise, 27kW
Elec.
Specs.
Rate
Amps
Maximum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3 75 90 90
240/60/3 65 80 80
480/60/3 33 40 40
Machine only
Elec.
Specs.
Rate
Amps
Maximum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3 59 70 70
240/60/3 55 70 70
480/60/3 29 40 40
MD66 with 70° F Rise (27kW) Booster
Elec.
Specs.
Rate
Amps
Maximum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3 134 150 150
240/60/3 119 150 150
480/60/3 62 70 70
Machine only
Elec.
Specs.
Rate
Amps
Maximum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3 53 70 70
240/60/3 48 60 60
480/60/3 25 30 30
MD66 with 40° F Rise (16kW) Booster
Elec.
Specs.
Rate
Amps
Maximum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3 103 125 125
240/60/3 93 110 110
480/60/3 48 60 60
MD44 with 40° F Rise (16kW) Booster
Elec.
Specs.
Rate
Amps
Maximum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3 97 125 125
240/60/3 86 110 110
480/60/3 44 60 60
4 F Rise,16kW
Elec.
Specs.
Rate
Amps
Maximum
Supply Ckt.
Conductor
Ampacity
Maximum
Overcurrent
Protective
Device
208/60/3 44 60 60
240/60/3 39 50 50
480/60/3 19 25 25
MD44
Booster Heater Only
MD66
Booster Heater Only
Due to an ongoing value analysis program at Moyer Diebel, specifications contained in this catalog are subject to change without notice.
3765 Champion Boulevard, Winston-Salem, NC 27105 • 336/661-1992 • Fax: 336/661-1979 • www.moyerdiebel.com
/