2
3
2
3
1
1
33-1/2" [850]
24" [609] 40-3/4 " [1035]
14-1/2" [368]
Clearance
2" [51]
14" [356]
20" [508]
25" [635]
1
Warning: Plumbingandelectricalconnectionsshould
bemadebyqualifiedpersonnelwhowillobserveallthe
applicableplumbing,sanitaryandsafetycodes.
Dimensionsshownininches&[mm]
7/09
SPECIFICATIONS
Capacity
NSFRacksperhr. 24
Motor Horsepower
Wash 1
Water Consumption
Gal.perhr.(max.use)
USgal. 20.4
Imp.gal. 17.5
Gal.perrack
USgal. 0.85
Imp.gal. 0.7
Temperatures °F/ °C
Wash(minimum) 150/66
Rinse(minimum) 180/82
Heating
Tankheat,electric(kW) 2
Electricbooster
(kWrequiredfor40°F/22°Crise) 4
Time Cycle in Seconds
Wash 100
Rinse 15
Dwell 5
Total 120
IUH351
UndercounterHighTemperature
OverflowTypeDishwashingMachine
withBuilt-inBoosterHeater
DuetoanongoingvalueanalysisprogramatChampion,specificationsinthiscatalogaresubjecttochangewithoutnotice.
Utilities
1 Electrical
208-240/50-60/1;2wire+ground;hardwiringrequired(seeboxesbelow)
2 Hot Water
140°F/60°C Min., connection for 40°F/22°C rise booster.
5ft.[1524]long,1/2"[12]I.D.flexiblefillhosewith3/4"[19]NPTconnection.
Flowpressure:18-22psi(124-152kPa)
3 Drain Connection
6ft.[1829]long,1"[25]I.D.flexiblehose.
Max.drainflow:8USgpm/6.9Imp.gals.
Elec. Specs
Rated
Amps
Minimum
Supply
Circuit
Ampacity
Maximum
Overcurrent
Protective
Device
208/50-60/1 22 30 30
240/50-60/1 24 30 30
IUH351with 40°F/22°C Rise ElectricBooster
Plan ViewFront View Side View
Uncrated Crated
Height 33-1/2" [851] 39-1/2" [1003]
Width 24" [609] 25" [635]
Depth 25" [635] 25-1/2" [648]
Ship Wt. lbs 148 [67 kg] 165 [57 kg]
*Frontlevelingfeetprovided.
L1 L2
G
Note:
Electrical supply
service must be
a 3-wire plus
ground for
connection
as shown.