Buhler DFTA 13 Operating Instructions Manual

Type
Operating Instructions Manual

This manual is also suitable for

Bühler AG
CH-9240 Uzwil, Switzerland
Phone +41 71 955 11 11
Fax +41 71 955 33 79
www.buhlergroup.com
Operating instructions
DFTA-66620-2-en-1803
Throw sifter
DFTA 12, DFTA 13, DFTA 23
2 Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
Preface
The operating instructions have to be handed over to those persons who are
responsible for the operation and the supervision of the machine.
This operating manual includes the information necessary for the operator for instal-
lation, operation and maintenance.
We have refrained from describing tasks requiring no special knowledge.
Instructions for repairs exceeding the normal maintenance tasks are not provided.
Important information
Procedures upon receipt
Inspect the equipment visually in accordance with the delivery contract as soon
as it has been received.
•Storage
Equipment that is not installed immediately must be stored protected from
weather and other influences.
Installation
The assembly and installation of the machine and machine equipment must
only be carried out by observing all installation instructions provided.
Design variants
If different designs are described in the documentation provided, only the infor-
mation concerning the version supplied will apply. We reserve the right to make
modifications due to technical progress up to the time of delivery.
Duty of instruction
Only trained specialists are permitted to commission the system or carry out
maintenance work on it. Prior to initial start-up, the operating personnel are
required to become familiar with the documentation provided.
Additional documents
Designation Identification number
Spare parts catalog DFTA-8011-1
Throw sifter Table of contents 3
© Copyright 2018 Bühler AG DFTA-66620-2-en-1803
Table of contents
1 Safety ........................................................................................................................ 5
1.1 Explanation of safety instructions ................................................................................................. 5
1.2 Safety of personnel....................................................................................................................... 5
1.3 Designated use............................................................................................................................. 6
1.3.1 ATEX authorisation........................................................................................................... 6
1.4 Connecting to the electrical mains................................................................................................ 7
1.5 Safety concept.............................................................................................................................. 7
1.6 Spare and wear parts ................................................................................................................... 7
2 Description ............................................................................................................... 9
2.1 Identification ................................................................................................................................. 9
2.1.1 Identification plate ............................................................................................................ 9
2.1.2 Specification key............................................................................................................... 9
2.1.3 Design variants................................................................................................................. 9
2.2 Design ........................................................................................................................................ 10
2.2.1 DFTA 12 model............................................................................................................... 10
2.2.2 DFTA 13, DFTA 23 models. ........................................................................................... 11
2.3 Function...................................................................................................................................... 12
2.4 Technical data............................................................................................................................. 13
2.4.1 Ambient conditions .........................................................................................................13
2.4.2 Connected load .............................................................................................................. 13
2.4.3 Aspiration ....................................................................................................................... 13
2.4.4 Weights .......................................................................................................................... 13
2.4.5 Determining the mesh widths......................................................................................... 13
2.4.6 Standard mesh widths.................................................................................................... 13
2.4.7 Noise data ...................................................................................................................... 13
2.5 Dimensioned drawings ............................................................................................................... 14
2.5.1 DFTA 12 ......................................................................................................................... 14
2.5.2 DFTA 13 ......................................................................................................................... 15
2.5.3 DFTA 23 ......................................................................................................................... 16
3 Transport ................................................................................................................ 17
3.1 Crane suspension....................................................................................................................... 17
3.1.1 DFTA 12 ......................................................................................................................... 18
3.1.2 DFTA 13, DFTA 23 ......................................................................................................... 18
3.2 Transport weights and volumes .................................................................................................. 18
4 Installation .............................................................................................................. 19
4.1 Site requirements ....................................................................................................................... 19
4.2 Installation .................................................................................................................................. 19
4.3 Product inlet................................................................................................................................ 19
4.4 Product outlet ............................................................................................................................. 20
4.5 Energy connections .................................................................................................................... 20
4.5.1 Vibrator motors............................................................................................................... 20
4 Table of contents Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
4.5.2 Electrical diagram ........................................................................................................... 21
4.6 Earthing ...................................................................................................................................... 22
5 Commissioning.......................................................................................................23
5.1 Checks before start-up ............................................................................................................... 23
5.2 Verifying EC conformity .............................................................................................................. 23
5.3 Vibrator motors ........................................................................................................................... 24
5.3.1 Direction of rotation ........................................................................................................ 24
5.3.2 Adjusting the stroke for DFTA 12 / 13 / 23 ...................................................................... 25
6 Operation.................................................................................................................27
6.1 Product inlet................................................................................................................................ 28
6.1.1 Product distribution over entire width.............................................................................. 28
6.1.2 Adjusting the gates ......................................................................................................... 28
6.1.3 Distribution over one and two sieve decks for DFTA 13 and DFTA 23............................ 28
6.2 Throw sifters ............................................................................................................................... 29
6.2.1 Changing sieves for DFTA 12 and DFTA 13 ................................................................... 29
6.2.2 Changing sieves for DFTA 23 ......................................................................................... 30
6.3 Faults and troubleshooting.......................................................................................................... 31
7 Maintenance............................................................................................................33
7.1 Maintenance plan ....................................................................................................................... 33
7.2 Cleaning...................................................................................................................................... 33
7.3 Changing the sieve clothing........................................................................................................ 34
7.4 Sieve clamping............................................................................................................................ 36
8 Decommissioning...................................................................................................39
8.1 Disassembly ............................................................................................................................... 39
8.2 Disposal ...................................................................................................................................... 39
9 After-sales service..................................................................................................41
9.1 Spare parts ................................................................................................................................. 41
9.2 Contact ....................................................................................................................................... 41
Throw sifter Safety 5
© Copyright 2018 Bühler AG DFTA-66620-2-en-1803
1 Safety
The machine was designed and manufactured in compliance with recognised safety
regulations. In spite of this, inappropriate use can put the user at risk of injury. For
this reason, safety has been given the highest priority.
1.1 Explanation of safety instructions
The corresponding safety instructions are indicated as follows:
1.2 Safety of personnel
Protective covers, hoods and gates must be installed and closed at all times.
Open or missing safety covers are danger spots for crush and cut injuries.
Always keep safety devices in good working condition. Never bypass or disable
any safety devices.
The system must be brought to a standstill before any maintenance work may
be carried out on the machine!
Make sure that all energy sources such as:
–Electricity
–Air
are switched off and disconnected. The lockable safety switch, which interrupts
the power at all poles, must be set to “0” and locked.
Danger!
Indicates an imminently hazardous situation which, if not avoided, can result
in death or grave injury.
Caution!
Indicates a potentially dangerous situation which, if not avoided, can result in prop-
erty damage and production failures.
Explosion hazard!
Indicates a potentially explosive situation which, if not avoided, can result in seri-
ous or fatal injuries and extensive property damage.
Note:
Indicates important information or instructions which, if not observed, can impair
the correct function of the machine and make it impossible to attain performance
parameters.
6 Safety Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
1.3 Designated use
The machine is designed solely for sieving animal feed and milling industry prod-
ucts. Any other use shall be considered noncompliant use.
1.3.1 ATEX authorisation
In areas where there is a risk of explosion, only machines and devices that are
approved for this purpose may be used (see identification plate).
If this symbol appears on the identification plate, the machine may be used in an Ex
zone.
This symbol is followed by the ATEX ID, which indicates the Ex zone in which the
machine may be used and the internal zone to which it may be connected.
Before machines with internal Ex zone can be connected to an installation, it must
be ensured on the installation side that no effective sources of ignition, metal parts
or stones can enter the machine from the installation.
Example:
2/3D means that the machine may be connected on the process side to an
Ex zone 21 and installed (used) in an Ex zone 22.
II 3/3D EEx c T=135°C x (Example)
Identifier for operating instructions
Maximum surface temperature to be expected in
normal operation at full load
Ignition protection class (if standard is applied)
D for dust / G for gas
External category
Internal category
Device group
Ex symbol
External category:
- = May not be installed in an Ex zone
* = Does not contain its own external source of ignition
1 = Conforms to ATEX category 1, connection to zone 20 or 0 is permitted
2 = Conforms to ATEX category 2, connection to zone 21 or 1 is permitted
3 = Conforms to ATEX category 3, connection to zone 22 or 2 is permitted
Internal category:
- = May not be connected to an Ex zone
* = Does not contain its own internal source of ignition
(A2) = (Assembly) with ignition protected devices conforming to ATEX category 2
1 = Conforms to ATEX category 1, connection in zone 20 or 0 is permitted
2 = Conforms to ATEX category 2, connection in zone 21 or 1 is permitted
3 = Conforms to ATEX category 3, connection in zone 22 or 2 is permitted
Throw sifter Safety 7
© Copyright 2018 Bühler AG DFTA-66620-2-en-1803
1.4 Connecting to the electrical mains
Observe the regulations of the local safety authorities.
The power supply must be fuse-protected in accordance with locally applicable
codes and regulations.
Check that the operating voltage and frequency correspond to the specifications
provided on the identification plate and in the control cabinet.
The electrical wiring to the control system must be connected according to the
wiring diagram to ensure that the phase conductors are really switched in the
case of single-phase power supplies.
1.5 Safety concept
The machine is normally part of an installation, and therefore has to be integrated
into the safety concept of the installation.
1.6 Spare and wear parts
Only original spare and wear parts may be used.
If this is not complied with, safe operation is no longer guaranteed, particularly if the
machine is used in an Ex zone.
8 Safety Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
Throw sifter Description 9
© Copyright 2018 Bühler AG DFTA-66620-2-en-1803
2 Description
2.1 Identification
2.1.1 Identification plate
The data indicated by “” have been imprinted on the identification plate according
to the specific machine.
2.1.2 Specification key
2.1.3 Design variants
Note:
Do not remove or cover up the identification plate.
Fig. 2.1
II */** EEx * T=*°C *
2
3
4
1
(1) Place of manufacture
(2) Type
(3) Machine No.
(4) Definition of ATEX ID
DFTA – 12
DFTA – 12 - Ex
Machine approved for use in potentially explosive
zone
Sieve area per sieve bottom = 1.2 m
2
Code
Machine type
Sieve area per sieve bottom
[m
2
]
12 1.2
13 1.3
23 2.3
10 Description Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
2.2 Design
2.2.1 DFTA 12 model
The machine consists of the dust-tight sieve housing which is supported on a frame
by hollow rubber springs. The machine is equipped with two sieve decks. The
clamping levers immediately release the slide-in sieve frames when unclamped,
which allows quick sieve changes. The sieve frame is supported on four hollow rub-
ber springs. This prevents vibrations from being transmitted to the housing.
Fig. 2.2
5
4
3
2
1
6
7
8
9
3
(1) Aspiration hood
(2) Sleeve
(3) Clamping levers for clamping the sieve
(4) Sieve deck (sieve with sieve frame)
(5) Door
(6) Frame
(7) Hollow rubber spring
(8) Vibrator motor
(9) Tension lock
Throw sifter Description 11
© Copyright 2018 Bühler AG DFTA-66620-2-en-1803
2.2.2 DFTA 13, DFTA 23 models
The machine consists of the dust-tight sieve housing which is supported on a frame
by hollow rubber springs. The machine is equipped with three sieve decks or option-
ally two sieve decks with a blind bottom between them (double flow system). The
clamping levers immediately release the slide-in sieve frames when unclamped,
which allows quick sieve changes. The sieve frame is supported on four hollow rub-
ber springs (7). This prevents vibrations from being transmitted to the housing.
Fig. 2.3
3
919
4
58
3672
3
(1) Aspiration hood
(2) Sleeve
(3) Clamping levers for clamping the sieve
(4) Sieve deck (sieve with sieve frame)
(5) Door
(6) Frame
(7) Hollow rubber spring
(8) Vibrator motor
(9) Transition piece
12 Description Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
2.3 Function
Product must be fed into the machine in metered quantities. In the inlet, the product
is evenly spread out over the entire sieve width of the machine. Oscillation of the
entire sieve box is achieved by means of vibrator motors. The sieve vibrations move
the product over the sieves and keep the sieves clean. This operating principle
allows high throughput rates and guarantees good sifting quality.
Fig. 2.4 DFTA 12
Fig. 2.5 DFTA 13 / DFTA 23
3 fractions
Aspiration
Aspiration Aspiration
4 fractions
2 fractions double flow system
(with blind bottom)
Throw sifter Description 13
© Copyright 2018 Bühler AG DFTA-66620-2-en-1803
2.4 Technical data
2.4.1 Ambient conditions
Temperature range: +5 to +50 °C.
2.4.2 Connected load
The connected load is specified according to customer and country.
2.4.3 Aspiration
To achieve good performance when operating the machine, connect the machine to
an aspiration system.
Required air volume:
•10 m3/min (DFTA 12)
•12 m3/min (DFTA 13)
•15 m3/min (DFTA 23)
2.4.4 Weights
2.4.5 Determining the mesh widths
Choosing the correct sieve mesh width is critical for performance and sifting quality.
Choose the mesh widths for the sieve deck according to the following formula:
MW = desired grain size of throughs / 0.8
Select the closest standard mesh width.
Application limit: 2 mm (smallest possible mesh width).
2.4.6 Standard mesh widths
2.4.7 Noise data
Machine type DFTA 12 DFTA 13 DFTA 23
Weights [kg] 330 670 880
Standard mesh widths in [mm]
2.0 2.5 3.15 3.55 4.0 5.0 7.1 9.0 11.0 25.0
Measured data
Equivalent sound pressure level in the machine area L
eq
=77dB (A)
14 Description Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
2.5 Dimensioned drawings
2.5.1 DFTA 12
Fig. 2.6
Throw sifter Description 15
© Copyright 2018 Bühler AG DFTA-66620-2-en-1803
2.5.2 DFTA 13
Fig. 2.7
16 Description Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
2.5.3 DFTA 23
Fig. 2.8
Throw sifter Transport 17
© Copyright 2018 Bühler AG DFTA-66620-2-en-1803
3 Transport
Allow personnel to transport the system only if they are familiar with the task and
have received proper training.
3.1 Crane suspension
The machine is shipped completely assembled and ready for connection. For trans-
port, the sieve box is fastened in place by four transport stabilisation devices (1) and
(2) that are attached to the sides. These devices are marked with yellow paint and
must be removed before commissioning the machine.
Danger!
Never walk beneath suspended loads.
Caution!
Check to ensure that the crane and lifting gear are designed such that they can
bear the load, and verify their maximum permitted load.
Hoist the machine at the specified suspension points only.
(Refer to Fig. 3.3,
18)
Fig. 3.1
1
2
(1) Upper transport stabilisation device (2) Lower transport stabilisation device
18 Transport Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
3.1.1 DFTA 12
Fasten the ropes to the frame; two ropes on the inlet side and one rope on the outlet
side.
3.1.2 DFTA 13, DFTA 23
Lift at the specified suspension points only.
3.2 Transport weights and volumes
See also Chap. 2.4.4, 13
Fig. 3.2
Fig. 3.3
1
(1) Suspension points
Note:
Always observe the transport weights provided by the forwarder in the shipping
documents.
Throw sifter Installation 19
© Copyright 2018 Bühler AG DFTA-66620-2-en-1803
4 Installation
4.1 Site requirements
Space requirements, floor openings, bearing surfaces and floor loads are in accord-
ance with separate planning documents.
4.2 Installation
Block the assembly area against unauthorised access.
Secure the surrounding area (remove any items that could cause someone to
stumble etc.).
Allow sufficient clearance for performing installation and set-up tasks.
The machine is installed directly to the floor. Fastening holes are provided on
the support plates of the machine frame. The machine must be exactly level hor-
izontally.
4.3 Product inlet
Product must be fed to the inlet directly into the middle of the machine so that the
product stream is distributed evenly over the entire sieve width. Best results are
achieved if the last piece of the inlet pipe is installed vertically to the machine. If that
is not possible, the inlet pipe can be connected at a light pitch (up to max. 45° from
vertical). If the vertical pipe piece to the inlet is longer than 1 m, an additional dead
box must be installed upstream of the sieve inlet.
Fig. 4.1
S = 5 to 10 mm
Note:
At distances greater than “S”, there is a danger that the rubber sleeves will wear
prematurely.
20 Installation Throw sifter
DFTA-66620-2-en-1803 © Copyright 2018 Bühler AG
4.4 Product outlet
Depending on the design, the sieve has 3 to 4 outlets for overs from each sieve deck
(1) and (2) as well as one outlet for throughs (3). When installing the piping be abso-
lutely sure that the individual outlets are connected with each other via adjustable
gates depending on the use of the sieve. Observe the pipe construction diagram!
So that no vibrations are transmitted, the outlets must be connected to the piping
using the rubber sleeves provided. Dimension “S” between the pipes = 5 to 10 mm
(see Fig. 4.1,
19).
4.5 Energy connections
Installation must be carried out in accordance with local and national regulations.
4.5.1 Vibrator motors
To protect the vibrator motor, it is absolutely necessary to install a protective motor
switch or a contactor with thermal overcurrent relays.
Ensure that the connection cables are suspended loosely. Due to the danger of a
cable breaking caused by sieve vibrations, only rubber cables may be used. Con-
necting the limit switch (vibration monitoring) (refer to Fig. 4.3,
21). The distance
between the limit switch and the sieve box is approx. 1 mm.
Note:
At distances greater than “S”, there is a danger that the rubber sleeves will wear
prematurely.
Fig. 4.2
Note:
Due to the axially parallel arrangement of the two vibrator motors, these must run
in opposite rotation direction and must be electrically interlocked with each other
(see Chapter 4.5.2,
21).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Buhler DFTA 13 Operating Instructions Manual

Type
Operating Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI