FSR FL-600P-SLD-ALM-C U-Cover User manual

Type
User manual

This manual is also suitable for

FSR 244 Bergen Boulevard, Woodland Park, NJ 07424, Phone: 973.785.4347 - Fax: 973.785.4207
43202 LIT1334B
BOX INSTALLATION - STEP 1
LOCATE AND POSITION BOX IN ACCORDANCE WITH FLOOR
PLANS. TOP SURFACE OF TEMPORARY COVER MUST BE SET
TO MATCH THE HEIGHT OF THE FINISHED FLOOR - ie STONE,
WOOD OR CONCRETE - SEE TYPICAL INSTALLATION HEIGHTS.
LEVEL AND ANCHOR BOX AS REQUIRED. USE SCREWS, NAILS,
OR WIRE TO PREVENT BOX FROM FLOATING DURING POUR.
REMOVE AND RETAIN TEMPORARY COVER AND SCREWS.
ROUTE CONDUITS TO BOX AS REQUIRED. GANG BRACKET
SCREWS MUST BE IN PLACE AND BOTTOMED TO ENSURE
SCREW VOIDS AFTER POUR. PLACE THIS INSTALLATION GUIDE
BACK INTO BOX, ALONG WITH ALL SUPPLIED ITEMS, AND
REINSTALL TEMPORARY COVER.
BOX INSTALLATION - STEP 2
SCREED TO TOP OF BOX SURFACE FOR 3/16" THICK
CARPET/FLOORING OR SPECIFIC HEIGHT TO ALLOW
FOR THICKER FINISHED FLOOR MATERIAL. HAND
TROWELING RECOMMENDED NEAR BOX EDGES.
BOX HAS NO HEIGHT ADJUSTMENT AFTER
CONCRETE POUR.
TEMPORARY
COVER
(8) #6-32 FLAT HEAD SCREW
CONCRETE SURFACE OR TOP
OF FINISHED FLOOR MATERIAL
(4) LEVELING BOLT
FL-600P INSTALLATION INSTRUCTIONS
INSTALLING ELECTRONIC COMPONENTS
PULL WIRES AND CABLES TO BOX AS NECCESSARY (REMOVAL OF
GANG MOUNTING BRACKETS MAY BE REQUIRED). TERMINATE
WIRES AND CABLES TO ELECTRONIC COMPONENTS, AND INSTALL
ELECTRONIC COMPONENTS ONTO GANG MOUNTING BRACKETS.
REINSTALL TEMPORARY COVER IF FINISHED COVER IS TO BE
INSTALLED AT A LATER DATE.
INSTALLED
ELECTRONIC
COMPONENT
GANG
MOUNTING
BRACKET
(2) #8-32 x .25 LG
FLAT HEAD
SCREW
DIVIDER ASSEMBLY
GANG
MOUNTING
PLATE
(2) #8-32 x .375 LG
SELF TAPPING
PAN HEAD
SCREW
GANG PLATE ASSEMBLY
GANG DIVIDER ASSEMBLY
4" BOX DIVIDER 5"-6" BOX DIVIDER 7"-12" BOX DIVIDER
(2) #8-32 x .25 LG
PAN HEAD
SCREW
DIVIDER HOLDER
DIVIDER
(2) #8-32 x .25 LG
PAN HEAD
SCREW
DIVIDER HOLDER
DIVIDER
DIVIDER HOLDER
(2) #8-32 x .25 LG
PAN HEAD
SCREW
DIVIDER
DIVIDER HOLDER MUST BE ORIENTED AS SHOWN WHEN ATTACHING
TO DIVIDERS, IN ORDER TO PROPERLY ASSEMBLE BOX INTERIOR.
SMALL GAP
FILLER*
LARGE GAP
FILLER*
* DIVIDER ASSEMBLY FOR 5" & 7" BOXES
POSITION DIVIDER ASSEMBLY IN BOX BEFORE INSTALLING
GANG PLATE ASSEMBLY. SECURE DIVIDER ASSEMBLY TO
GANG PLATE ASSEMBLY WITH SCREWS AS NOTED.
* GAP FILLERS ARE OPTIONAL, PER DESIRED
CONFIGURATION (SEE PREVIOUS PAGE),
AND ARE INSTALLED SIMILARLY TO
DIVIDER ASSEMBLIES.
(FOR USE WITH FL-600P SERIES COVERS ONLY)
CONCRETE
SCREED FLUSH
FLOOR BOX
TEMPORARY
COVER
CARPET
CONCRETE
FLOOR BOX
1/8" THICK
COVER WITH
EDGING
CONCRETE FLOOR BOX
1/8" THICK
COVER WITH
EDGING
FINISHED
FLOOR
CONCRETE
TEMPORARY
COVER
FLOOR BOX
SCREED FLUSH
CONCRETE
FINISHED
FLOOR
SHIM TO VINYL
THICKNESS
1/8" THICK COVER
FLOOR BOX
CONCRETE FLOOR BOX
1/8" THICK COVER
TYPICAL INSTALLATION HEIGHTS FLOOR BOX TEMPORARY COVER WILL EITHER BE INSTALLED DIRECTLY ON THE BOX OR SHIMMED
BASED ON THE COVER AND FLOORING SPECIFICATIONS. SHIM KITS SOLD SEPARATELY (FL-600P-CSK).
THE TEMPORARY COVER MAY NOT BE FLUSH WITH THE FINISH FLOOR IN ALL INSTALLATIONS.
Carpeted or Tile Floors, Cover types - BLP, BSQ, B, SLP, SSQ, S
COVER FLUSH WITH CONCRETE
(FOR 1/8" THICK COVER) CARPET FLOORING TILE OR LAMINATE FLOORING
STAINED FLOORINGVINYL FLOORINGCOVER FLUSH WITH CONCRETE
(FOR 1/8" THICK COVER)
Vinyl or Stained Concrete, Cover types - BK, SS, BRS
GANG MOUNTING BRACKET CONFIGURATION
PER CUSTOMER SPECIFICATIONS, CONFIGURE GANG MOUNTING BRACKETS AS
SHOWN BELOW AND REASSEMBLE INTO BOX.
REMOVABLE LARGE CENTER DIVIDER
REMOVABLE SMALL CENTER DIVIDER
REMOVABLE SMALL CENTER DIVIDER
REMOVABLE LARGE CENTER DIVIDER
CENTER DIVIDER CONFIGURATION (NOT APPLICABLE ON 4" BOX)
SET ASIDE TEMPORARY COVER AND SCREWS FOR POSSIBLE RE-INSTALLATION.
REMOVE AND RETAIN GANG MOUNTING BRACKETS AND SCREWS TO CONFIGURE
CENTER DIVIDERS.
POSSIBLE GANG DIVIDER LOCATION
"5 GANG SIDE" MOUNTING BRACKET CONFIGURATIONS
5 OR 6 GANG MOUNTING PLATE DIVIDER HOLDER
OPTIONAL DIVIDER
LARGE GAP FILLER
SMALL GAP FILLER
"6 GANG SIDE" MOUNTING BRACKET CONFIGURATIONS
1G 1G 2G 1G 1G 3G 1G 3G 1G 1G 4G
2G 2G 2G 3G 4G 1G 5G
1G 3G 1G 3G
2G 2G 2G 2G
1G 4G
2G 3G 3G 1G
2G 2G
3G 2G 4G 1G 6G
"6 GANG SIDE"
"5 GANG SIDE"
5 GANG SIDE
6 GANG SIDE
CONCRETE
SCREED FLUSH
FLOOR BOX
SHIM 1/4"
TEMPORARY
COVER
CONCRETE
SHIM TO VINYL
THICKNESS
FLOOR BOX
3/8" THICK COVER
FINISHED
FLOOR
CONCRETE
3/8" THICK COVER
FLOOR BOX
CONCRETE
3/8" THICK
COVER
FINISHED
FLOOR
FLOOR BOX
SLEEPER
SYSTEM
(IF USED)
CONCRETE SLEEPER
SYSTEM
(IF USED)
FLOOR BOX
1/8" THICK
COVER
FINISHED
FLOOR
CONCRETE
TEMPORARY
COVER
FLOOR BOX
FINISHED
FLOOR
1/4" (SEE NOTE)
CONCRETE
TEMPORARY COVER
FLOOR BOX
FINISHED
FLOOR EDGING
HEIGHT
CONCRETE
FINISHED FLOOR
SLEEPER SYSTEM (IF USED)
FLOOR BOX
1/8" THICK COVER
WITH EDGING
COVER ABOVE CONCRETE
(FOR COVER WITH EDGING) WOOD FLOORING
Wood / Floating Wood, Cover types - BLP, BSQ, B, SLP, SSQ, S
FOR 3/8" THICK COVER LOWER TEMPORARY
COVER AN ADDITIONAL 1/4" FROM FINISHED
FLOOR DIMENSION OR USE SHIM KIT
NOTE:
COVER ABOVE CONCRETE
(FOR COVER WITHOUT EDGING)
Wood / Floating Wood, Cover types - BK, SS, BRS (1/8"), SLD-ALM, SLD-Color (3/8")
WOOD FLOORING WOOD FLOORING
STAINED FLOORINGVINYL FLOORING
Vinyl or Stained Concrete, Cover types - SLD-ALM, SLD-Color
COVER FLUSH WITH CONCRETE
(FOR 3/8" THICK COVER)
FLOOR BOX TEMPORARY COVER WILL EITHER BE INSTALLED DIRECTLY ON THE BOX OR SHIMMED
BASED ON THE COVER AND FLOORING SPECIFICATIONS. SHIM KITS SOLD SEPARATELY (FL-600P-CSK).
THE TEMPORARY COVER MAY NOT BE FLUSH WITH THE FINISH FLOOR IN ALL INSTALLATIONS.
TYPICAL INSTALLATION HEIGHTS
  • Page 1 1
  • Page 2 2

FSR FL-600P-SLD-ALM-C U-Cover User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI