Premier RO-TFM-5SV Installation, Operation and Maintenance Manual

Type
Installation, Operation and Maintenance Manual

This manual is also suitable for

Page 1
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
RO-TFM-4SV /W50
RO-TFM-5SV /W50
PREMIER 25
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Save manual for future reference
MODELS
Warning
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
or operating parameters may lead to the product’s failure.
(3$(797HVWYHUL¿HGSHUIRUPDQFH
Physical removal of microbial
contamination agents in drinking water.
6\VWHP7HVWHGDQGFHUWL¿HGE\:4$DJDLQVW16)$16,
6WDQGDUGIRUWKHUHGXFWLRQRIWKHFODLPVVSHFL¿HGRQWKH
performance data sheet.
Watts Premier 8716 W Ludlow Drive, Suite 1 Peoria, AZ 85381
Phone: 800-752-5582 www.premierH2o.com Fax: 623-866-5666
Manual: 199348 Manual Date: 09/06/2016
Page 2
Thank you for your purchase of a state of the art Premier Reverse Osmosis (RO) water treatment system. Water quality
concerns are becoming more of a focus for the public. You may have heard about contaminants in the drinking water, such
as Arsenic, Chromium, Cryptosporidium or Giardia. There may also be some local water issues such as high levels of Lead
and Copper. This Premier water treatment system has been designed and tested to provide you with high quality drinking
water for years to come. The following is a brief overview of the system.
Your Reverse Osmosis System:
Osmosis is the process of water passing through a semi permeable membrane in order to balance the concentration of
contaminants on each side of the membrane. A semi permeable membrane is a barrier that will pass some particles like clean
drinking water, but not other particles like arsenic and lead.
Reverse osmosis uses a semi permeable membrane; however, by applying pressure across the membrane, it concentrates
contaminants (like a strainer) on one side of the membrane, producing crystal clear water on the other. This is why RO
V\VWHPVSURGXFHERWKFOHDQGULQNLQJZDWHUDQGZDVWHZDWHUWKDWLVÀXVKHGIURPWKHV\VWHP7KLVUHYHUVHRVPRVLVV\VWHPDOVR
XWLOL]HVFDUERQEORFN¿OWUDWLRQWHFKQRORJ\DQGFDQWKHUHIRUHSURYLGHDKLJKHUTXDOLW\GULQNLQJZDWHUWKDQFDUERQ¿OWUDWLRQ
systems alone.
<RXUV\VWHPLVDIRXURU¿YHVWDJH52ZKLFKLVEDVHGXSRQVHSDUDWHWUHDWPHQWVHJPHQWVZLWKLQWKHRQHFRPSOHWHZDWHU
¿OWUDWLRQV\VWHP7KHVHVWDJHVDUHDVIROORZV
6WDJH±6HGLPHQW¿OWHUUHFRPPHQGHGFKDQJHPRQWKV
7KH¿UVWVWDJHRI\RXU52V\VWHPLVD¿YHPLFURQVHGLPHQW¿OWHUWKDWWUDSVVHGLPHQWDQGRWKHUSDUWLFXODWHPDWWHU
like dirt, silt and rust which affect the taste and appearance of your water.
6WDJHDQG±&DUERQ¿OWHUVUHFRPPHQGHGFKDQJHPRQWKV
7KHVHFRQGDQGWKLUGVWDJHVHDFKFRQWDLQDPLFURQFDUERQEORFN¿OWHU7KLVKHOSVHQVXUHWKDWFKORULQHFKORUDPLQHV
and other materials that cause bad taste and odor are greatly reduced.
6WDJH0HPEUDQHUHFRPPHQGHGFKDQJH\HDUV
Stage four is the heart of the reverse osmosis system, the RO membrane. This semi permeable membrane will
effectively take out TDS & Sodium and a wide range of contaminants such as Percholate, Chromium, Arsenic,
Copper, Lead as well as Cysts, such as Giardia and Cryptosporidium. Because the process of extracting this high
quality drinking water takes time, your RO water treatment system is equipped with a storage tank.
6WDJH&DUERQLQOLQH¿OWHUUHFRPPHQGHGFKDQJHPRQWKV
7KH¿QDOVWDJHLVDQLQOLQHJUDQXODUDFWLYDWHGFDUERQ*$&¿OWHU7KLV¿OWHULVXVHGDIWHUWKHZDWHUVWRUDJHWDQN
DQGLVXVHGDVD¿QDOSROLVKLQJ¿OWHU
Note: Filter & Membrane life may vary based upon local water conditions and/or use patterns.
System Maintenance
Just because you can not taste it, does not mean that it is not there. Contaminants such as Lead, Chromium and Arsenic are
XQGHWHFWDEOHWRWKHWDVWH$GGLWLRQDOO\RYHUWLPHLI\RXGRQRWUHSODFHWKH¿OWHUHOHPHQWVRWKHUEDGWDVWHVDQGRGRUVZLOO
be apparent in your drinking water.
,WLVLPSRUWDQWWRFKDQJHRXW\RXU¿OWHUVDWWKHUHFRPPHQGHGLQWHUYDOVDVLQGLFDWHGLQWKLVV\VWHPPDQXDO:KHQUHSODFLQJ
WKH¿OWHUHOHPHQWVSD\VSHFLDODWWHQWLRQWRDQ\FOHDQLQJLQVWUXFWLRQV6KRXOG\RXKDYHDQ\IXUWKHUTXHVWLRQVSOHDVHUHIHUWR
our web site at www.premierh2o.com or call our customer service department at 
With proper installation and maintenance, this system will provide you with high quality water for years to come.
All of Premiers water enhancement products are rigorously tested by independent laboratories for safety and reliability.
,I\RXKDYHDQ\TXHVWLRQVRUFRQFHUQVSOHDVHFRQWDFWRXUFXVWRPHUVHUYLFHGHSDUWPHQWDW
RXWVLGH86$RUUHIHUWRRXURQOLQHWURXEOHVKRRWLQJJXLGHDWZZZSUHPLHUKRFRP
Page 3
Table of Contents
Operational Parameters ................................................................................................................... 4
Contents of Reverse Osmosis System ............................................................................................ 4
Installation & Startup
7RROV5HFRPPHQGHG)RU,QVWDOODWLRQ .............................................................................................. 4
Plumbing diagram and parts list ...................................................................................................... 5
'ULOOD+ROHIRUWKH5HYHUVH2VPRVLV)DXFHW .................................................................................. 6
+RZWRXVH4XLFN&RQQHFW)LWWLQJVRQ<RXU526\VWHP ................................................................ 6
6WDQGDUG)DXFHW,QVWDOODWLRQ ........................................................................................................... 7
7RS0RXQW)DXFHW,QVWDOODWLRQ ........................................................................................................ 8
+HOSIXO,QVWDOODWLRQ7LSVIRUWKH3UHPLHU7RS0RXQW)DXFHW ............................................................ 9
$GDSWD9DOYH,QVWDOODWLRQ ............................................................................................................. 10
'UDLQ6DGGOH,QVWDOODWLRQ................................................................................................................ 10
Drain Saddle Tube Connection.......................................................................................................11
*UHHQ7XEH&RQQHFWLRQ)HHG:DWHU .......................................................................................... 12
Reverse Osmosis Module Mounting.............................................................................................. 12
Red 1/4” Tube Connection............................................................................................................. 12
7DQN%DOO9DOYH,QVWDOODWLRQ ............................................................................................................ 12
Blue Tube Connection - Storage Tank ........................................................................................... 12
6WDUWXS,QVWUXFWLRQV....................................................................................................................... 13
Maintenance & Troubleshooting
Six Month Maintenance ................................................................................................................. 14
Annual Maintenance ..................................................................................................................... 15
Membrane Replacement .............................................................................................................. 16
Check Air Pressure in the Tank ..................................................................................................... 17
3URFHGXUHIRU([WHQGHG1RQ8VH0RUHWKDQPRQWKV .............................................................. 17
Troubleshooting ............................................................................................................................ 18
Product Technical & Warranty Information
Performance Data Sheet ................................................................................................................ 19
$UVHQLF)DFW6KHHW ......................................................................................................................... 20
Service Record ............................................................................................................................... 21
/LPLWHG:DUUDQW\ ............................................................................................................................ 22
%HIRUHLQVWDOODWLRQSOHDVHWDNHDPRPHQWWR¿OORXWWKHZDUUDQW\FDUGRQSDJH
Page 4
Installation must comply with State and local plumbing regulations. Do not use with water that is micro
biologically unsafe or of unknown quality without adequate disinfection before or after the system.
System is intended to be installed using the cold water supply only.
Tools Recommended For Installation
'LDPRQG7LSSHG+ROH6DZELWIRUIDXFHWRSHQLQJ&RXQWHU7RSV3RUFHODLQ6WDLQOHVV6LQNV
´$GMXVWDEOH:UHQFK Phillips bit for electric drill
2SHQ(QG:UHQFK 1HHGOH1RVH3OLHUV
´2SHQ(QG:UHQFK Adjustable Pliers
Electric Drill Sharp Knife
1/8" diamond tip bit, pilot hole Phillips Screw Driver
1/4” drain saddle hole
Contents of the Reverse Osmosis (RO) System
Operating Temperatures: Maximum 100°)& Minimum 40)&
Operating Pressure: 0D[LPXPSVLNJFP
2
0LQLPXPSVLNJFP
2
pH Parameters: Maximum 11 Minimum 2
Iron: Maximum 0.2 ppm
TDS (Total Dissolved Solids) < 1800 ppm
Turbidity 178
Hardness Maximum 10 Grains Per Gallon *
Hardness: Recommended hardness not to exceed 10 grains per gallon, or 170 parts per million.
* System will operate with hardness over 10 grains but the membrane life may be shortened.
Addition of a water softener may lengthen the membrane life.
Copper Tube: Reverse Osmosis water should not be run through copper tube as the purity of the
water will leach copper causing an objectional taste in water and pin holes may form in the tube.
Water Pressure: The operating water pressure in your home should be tested over a 24 hour
SHULRGWRDWWDLQWKHPD[LPXPSUHVVXUH,IWKHLQFRPLQJZDWHUSUHVVXUHLVDERYHSVLWKHQD
water pressure regulator is required. A booster pump is needed for incoming water pressure
under 40psi.
Operational Parameters
INSTALLATION & STARTUP
7DQN±%OXHRU:KLWH
0RGXOH±%OXHRU:KLWH)LOWHUV3UH,QVWDOOHG
1 Parts Bag
)DXFHW%DJ
1 Manual
5 Stage RO System has 3 vertical bowls. 4 Stage RO System has 2 bowls.
If any of the items are missing please contact Premier prior to installing.
Page 5
MEMBRANE HOUSING
STORAGE TANK
FEED WATER
POST-FILTER
TEE
FITTING
DRAIN
SADDLE
CARBON
PRE-FILTER
SHUT-OFF
VALVE
SEDIMENT
PRE-FILTER
CARBON
PRE-FILTER
FLOW
THIRD FILTER BOWL
ON FIVE-STAGE ONLY
MAIN WATER SUPPLY
SHUT-OFF VALVE
ADAPT-A-VALVE
TO
KITCHEN
SINK
BLUE
RED
GREEN
GREENGREEN
BLUE
BLUE
BLUE
FAUCET
16
14
14
12
11
23
1
9
10
17
10
10
19
7
TANK
VALVE
15
8
21
21
21
2 3 3
TANK STAND
20
6
4
5 5 5
13
18
17
DRAIN
BLUE
11
24
,7(0 3$57 '(6&5,37,21
1 560010 *$&,1/,1(),/7(5)
1 ALT 560005 *$&,1/,1(),/7(5)
2 104017 6(',0(17),/7(5'(30
3 101009 &$5%21%/2&.0
3 ALT 100036 *$&&8,1
4 560018 *3'520(0%5$1(#:
4 ALT 560014 *3'520(0%5$1(
5 500015 +286,1*6%/8(%/.)
5 ALT 500017 +286,1*6:+,7(:+,7()
6 500075 0(0%5$1(+286,1*
7 116001 )$8&(73$,5*$3&+520(
8 ALT 116094 )$8&(772302817&+520($,5*$3
8 119007 6725$*(7$1.*$/:+,7(
9 125017 &211(&7253/$67,&&[0
9 ALT 400031 &211(&7253/$67,&&;0
,7(0 3$57 '(6&5,37,21
10 125031 (/%2:3/$67,&&[0
11 125034 (/%2:3/$67,&&[0
12 125063 7((3/$67,&0[&[&
13 125041 81,213/$67,&&[&
14 131021 +(;1,33/(/)%5$660[0
15 134039 7$1.9$/9()[&
16 560080 ADAPT-A-VALVE
17 164006 &/,30(0%5$1(72%5$&.(7
18 164010 &/,30(0%5$1(72,1/,1(),/7(5
19 164056 '5$,16$''/(4&
20 119028 7$1.67$1'
21 113029 25,1*),/7(5+286,1*3.
22 199348 0$18$/
23 134003 $8720$7,&6+872))9$/9(
24 622055 )/2:5(675,&725*5((1#*3'
24 ALT 622052 )/2:5(675,&7255('#*3'
FLOW DIAGRAM
THE FOLLOWING MODELS
CONTAIN A 50 GPD RO
MEMBRANE PRE-INSTALLED:
RO-TFM-4SV-W50 &
RO-TFM-5SV-W50
Page 6
After drilling, remove all sharp edges and make sure the surroundings
of the sink are cooled before mounting the faucet.
Step 3
Step 4
Determine desired location for the RO faucet on your sink and place
a piece of masking tape over where the hole is to be drilled. Mark the
center of the hole on the tape.
Step 1
8VLQJDYDULDEOHVSHHGGULOOVHWRQWKHVORZHVWVSHHGGULOOD³SLORW
hole through both porcelain and metal casing of sink at the marked
FHQWHURIWKHGHVLUHGORFDWLRQ8VHOXEULFDWLQJRLORUOLTXLGVRDSWRNHHS
WKHGULOOELWFRRO,IGULOOELWJHWVKRWLWPD\FDXVHWKHSRUFHODLQWRFUDFN
RUFKLS
8VLQJD
¼” diamond tip hole saw, proceed to drill the large hole. Keep
drill speed on the slowest speed and use lubricating oil or liquid soap
to keep the hole saw cool during cutting.
Step 2
Counter Top / Porcelain & Stainless Steel Sink
Note:
Most sinks are pre drilled with 1 ¼” diameter hole that you can use for your RO faucet.
(If you are already using it for a sprayer or soap dispenser, see step 1)
Porcelain sinks are extremely hard and can crack or chip easily.
Use extreme caution when drilling. Premier accepts no responsibility for
damage resulting from the installation of faucet. Diamond tip bit recommended.
Marble Counter-top
:HUHFRPPHQGFRQWDFWLQJDTXDOL¿HGFRQWUDFWRUIRUGULOOLQJDKROHLQDmarble counter-top.
Drill a Hole for the Reverse Osmosis Faucet
How to use the Quick Connect Fittings
7RPDNHDFRQQHFWLRQWKHWXEHLVVLPSO\SXVKHGLQWRWKH¿WWLQJ7KHXQLTXHORFNLQJV\VWHPKROGVWKHWXEH¿UPO\LQSODFH
ZLWKRXWGHIRUPLQJLWRUUHVWULFWLQJÀRZ8VHWKHVWHSVEHORZLQUHIHUHQFHWRDQ\TXLFNFRQQHFWWXEHFRQQHFWLRQV
,WLVHVVHQWLDOWKDWWKHRXWVLGHGLDPHWHUEHIUHHRIVFRUH
marks and that burrs and sharp edges be removed before
LQVHUWLQJLQWR¿WWLQJ
)LWWLQJJULSVEHIRUHLWVHDOV (QVXUH WXEH LV SXVKHG LQWR
the tube stop.
3XVKWKHWXEHLQWRWKH¿WWLQJWRWKHWXEHVWRS7KHFROOHW
JULSSHUKDV VWDLQOHVV VWHHO WHHWK ZKLFK KROG WKH WXEH
¿UPO\LQSRVLWLRQZKLOHWKH2ULQJSURYLGHVDSHUPDQHQW
leak proof seal.
3XOORQWKHWXEHWRFKHFNWKDWLWLVVHFXUH,WLVDJRRGSUDFWLFH
to test the system prior to leaving site and /or before use.
To disconnect, ensure the system is
depressurized before removing the tube. Push in the col-
OHFWVTXDUHO\DJDLQVWIDFHRI¿WWLQJ :LWK WKH FROOHW KHOG
LQWKLVSRVLWLRQWKHWXEHFDQEHUHPRYHG7KH¿WWLQJFDQ
then be reused.
Page 7
)HHGERWKWKHUHGDQGEODFNWXELQJ
through the pre drilled hole in the sink/
counter until faucet is seated.
8QGHUWKHVLQNRQWRWKHWKUHDGHG
IDXFHWVWHPLQRUGHU¿UVWVOLGH RQ WKH
VORWWHGZDVKHULWHPWKHZKLWHVSDFHU
ZLWKWKHRSHQHQG83LWHPWKHSODLQ
ZDVKHULWHPWKHKH[QXWZDVKHU
LWHPDQGODVWO\VHFXUHZLWKQXWLWHP

Step 6
Premier Standard Faucet Installation
Step 5
1. Faucet
 %ODFN'UDLQ7XEH´%ODFN
 5HG7XEH´
4. Escutcheon Plate
5. Full Circle Rubber Gasket
 6ORWWHG0HWDO:DVKHU
 3ODVWLF6OHHYH
 3ODLQ:DVKHU
 +H[1XW:DVKHU
 +H[1XW
11. Plastic Tube Insert
 :KLWH3ODVWLF'HOULQ6OHHYH
 :DWHU&RQQHFWRU1XW
 %OXH7XEH´
Parts List
1
2
3
4
7
8
9
10
1
11
12
13
14
Connect Blue Tube from the RO to the Faucet
Step 7
Locate the blue 1/4” tube attached to the RO module labeled
³)DXFHW´5HPRYHDEUDVVQXWSODVWLFVOHHYHDQGEUDVVLQVHUWIURP
the faucet parts bag. To assemble, place the brass nut on the blue
WXEH¿UVWWKHQWKHVOHHYHVPDOOWDSHUHGHQGRIVOHHYHPXVWSRLQW
WRWKHHQGRIWXEHDQGWKHQSXVKWKHEUDVVLQVHUWDOOWKHZD\LQWR
WKHHQGRIWKHWXEH6HH3LFWXUH
,QVHUWWKHEOXHWXEHLQWRWKHHQGRIWKHIDXFHWVKDQNDQGXVHD
wrench to tighten the brass nut securely.
Step 8
Page 8
Premier Monitored (Top Mount) Faucet Installation
1
2
3
4
4. Feed the toggle bolt and tubes through the mounting hole in The
VLQN7HVW¿WIDXFHWSODFHPHQW
 Using a Phillips head screwdriver torque the toggle bolt through
the spout hole until the faucet is secure. Do not overtighten!
$´´0RXQWLQJKROHLVUHTXLUHGIRUIDXFHWLQVWDOODWLRQ
8. Pull the Battery Safety Tab out to activate faucet monitor. Make sure that
WKHFOHDUGUDZHULV¿UPO\VHDWHGLQWKHIDXFHWEDVH7KHPRQLWRUZLOOÀDVK
EULHÀ\RQFHDFWLYDWHG
7. Insert spout into the faucet base until fully seated.
8
7
A) Connect tubes to the RO faucet (Figure A)
B) Mount the RO faucet (Figure B)
&3XOO%DWWHU\7DEDQG,QVWDOO6SRXW)LJXUH&
7KLV52IDXFHWLVHTXLSSHGZLWKTXLFNFRQQHFW¿WWLQJVIRUHDV\WXEH
installation. To connect tubes, simply push them ¿UPO\ into their
FRUUHVSRQGLQJ¿WWLQJRQWKH52IDXFHWXQWLOIXOO\VHDWHG
1.&RQQHFW´
BLUE tube (Parts Bag) ´)LWWLQJRQ7RJJOH%ROW
2. &RQQHFW´BLACK tube (Parts Bag) ´)LWWLQJRQEDVHRIIDXFHW
3.&RQQHFW´RED tube (Parts Bag) ´)LWWLQJRQEDVHRIIDXFHW
$SSUR[LPDWHO\´RIWKHWXEHVKRXOGJRLQWRWKH¿WWLQJ
A
B
C
 Peel the white backing paper off the seal on the bottom of the
IDXFHWEDVHDQGSUHVV¿UPO\RYHUWKHPRXQWLQJORFDWLRQ
³7KLVSURGXFWFRQWDLQVDEXWWRQFHOOEDWWHU\,IVZDOORZHGLWFRXOGFDXVH
VHYHUHLQMXU\RUGHDWKLQMXVWKRXUV6HHNPHGLFDODWWHQWLRQLPPHGLDWHO\´
&$87,21
9.'HWHUPLQHZKHUHWKH´EOXHWXELQJIURPWKHIDXFHWDQGWKH´EOXH
WXELQJPDUNHG³)$8&(7´IURPWKH520RGXOHZRXOGMRLQWRJHWKHU
comfortably. Cut the tubes leaving a straight cut on both tubes. Insert the
´EOXHWXEHPDUNHG³)$8&(7´IURPWKH52PRGXOHLQWRWKH
´HQGRIWKH´[´TXLFNFRQQHFWXQLRQVXSSOLHGLQWKHSDUWVEDJ
0DNHVXUHWKHWXEHLVSXVKHGLQDOOWKHZD\WRWKHWXEHVWRS,QVHUWWKH´
EOXHWXEHIURPWKHIDXFHWLQWRWKH´RSHQHQGRIWKH´[´TXLFN
connect union. Make sure the tube is pushed in all the way to the tube stop.
Page 9
Helpful Installation Tips for the Premier Top Mount Faucet
During shipping/handling the tog
gle bolt on your new faucet may
push up out of position. Prior to the
install, hold the faucet as shown in
the picture and pull down on the
wing nut. This will ensure that the
2ULQJVDUHLQWKHLUSURSHUSRVLWLRQ
and that your faucet will have a
good seal.
Disassembling your faucet is never
recommended as this could void
your warranty. If it is necessary to
remove the fitting at the end of the
toggle bolt you must follow the fol
ORZLQJSURFHGXUHIRUUHDVVHPEO\
3ULRU WR UHFRQQHFWLQJ WKH ILWWLQJ
to the toggle bolt, you must insert
WKH´EOXHWXEHLQWRWKHILWWLQJ
7KHUH DUH VPDOO 2ULQJV LQVLGH RI
the fitting that could be pushed out
of position if the blue tube is not
fully inserted first. Failure to do so
may cause the faucet to leak.
Page 10
Turn off the cold water supply to the faucet by turning the angle stop valve completely off.
Open cold water sink faucet to relieve pressure.
Step 9
Step 10
&KRRVLQJWKHFRQ¿JXUDWLRQWKDW¿WV\RXUSOXPELQJDWWDFKWKHDGDSWDYDOYHDVLOOXVWUDWHGLQ
the four photos above.
Adapt-a-Valve Installation
'RQRWXVH7HÀRQWDSHZLWKWKH$GDSWD9DOYHWARNING:
Caution:
Water supply line to the system must be from the cold water supply line only.
Hot water will severely damage your system.
´&RQ¿JXUDWLRQ
(With Brass Fittings)
* Insert White Washer
´&RQ¿JXUDWLRQ
(Without Brass
Fittings)
*White
Wa s h er
Hot
Supply
Cold
Supply
Hot
Supply
Cold
Supply
Verify contents prior to installation:
3ODVWLF$GDSWD9DOYHZLWKEODFNFROOHW
%UDVV$GDSWHUQRZDVKHU
%UDVV$GDSWHUZLWKEODFNZDVKHU
:KLWHUXEEHUZDVKHU
0DNHVXUHWKDWWKHEODFNFROOHWLVLQVWDOOHGLQWRWKH´RSHQLQJRQWKH$GDSWDYDOYH
'RQ¶WIRUJHWWRLQVWDOOWKHZKLWHFRPSUHVVLRQZDVKHUZLWKWKH´FRQ¿JXUDWLRQ
%UDVVDGDSWHU$GRHVQRWQHHGWREHWLJKWHQHGZLWKDZUHQFKRQO\¿QJHUWLJKW
Black
Collet
A
TIPS:
A
White
Wa s h er
Page 11
'UDLQ6DGGOH¿WVVWDQGDUGó´±ò´GUDLQSLSHV
Drain Saddle Installation
Step 11
Step 12
Step 13
The drain saddle must be installed at least 1 ½” above the nut
of the P-Trap elbow or cross bar from the garbage disposal to
LQVXUHSURSHUGUDLQDJH8VLQJWKH´GULOOELWGULOOLQWRWKHGUDLQ
SLSHDWEHVWDYDLODEOHORFDWLRQDVVSHFL¿HGDERYHIRUGUDLQVDGGOH
installation. Take extreme caution to only drill through one side
of the drain pipe.
The small square black foam gasket with a circle cut out of the middle
must be applied to the inside of the drain saddle. Remove sticky tape
backing and stick to the drain saddle as shown.
1 Semicircle bracket with opening
6FUHZV)RDPJDVNHW
1XWVIRUVFUHZV  6HPLFLUFOHEUDFNHW
Gather the pieces of the drain saddle:
Caution:
Do not over tighten the screws. It may crack the drain saddle.
If you have a garbage disposal, do not install the drain saddle near it.
Installation of the drain saddle must be either above the garbage disposal, or
if a second sink drain is available, install it above the cross bar on the second
drain. Installation of the drain saddle near a garbage disposal may cause
the drain line to plug. If no other installation of drain line is available, Premier
offers drain line installation kit (part number 164020) that can be used with
garbage disposals.
Caution:
The black 3/8” drain tube must be as SHORT and STRAIGHT as possible to the drain
saddle, making a downward slope from faucet to drain saddle to allow for proper
drainage. This is a gravity fed line and if there is any bend or dip in the tube, the rinse
ZDWHUZLOOQRWÀRZLQWRWKHGUDLQSURSHUO\:DWHUPD\EDFNXSDQGFRPHRXWWKHDLU
gap hole in the back of the faucet.
IMPORTANT:
Measure the 3/8” black tube from faucet to the drain saddle on the
drain pipe and make a straight cut to the correct length.
&RQQHFWWKHEODFNWXEHWRWKHRSHQTXLFNFRQQHFW¿WWLQJRQWKHGUDLQ
saddle by pushing the tube all the way to the tube stop.
Step 16
Step 15
Assemble the drain saddle around the drain pipe and align drain
VDGGOH¿WWLQJRSHQLQJZLWKWKHKROHGULOOHGLQWKHSUHYLRXV
step - you may use a small screwdriver to feed through the drain
VDGGOHLQWRWKHGUDLQSLSHWRDLGZLWKWKHDOLJQPHQW8VLQJD3KLOOLSV
screw driver tighten the drain saddle bolts evenly and securely on
both sides.
Step 14
Page 12
Reverse Osmosis Module Mounting
Step 18
Determine best location for the RO module to be mounted to allow
IRUIXWXUHV\VWHPPDLQWHQDQFH8VLQJWKHPRXQWLQJKROHVRQWKH
bracket, mark the location for the mounting screws on the cabinet
ZDOOXQGHUWKHVLQN,QWKHSDUWVEDJORFDWHWKHWZRVHOIWDSSLQJ
VFUHZV8VLQJDQHOHFWULFGULOOZLWKD3KLOOLSVELWVFUHZWKHPLQWR
the cabinet at the marked location. Hang the module on the screws
using the mounting holes in the bracket
Green Tube Connection
Step 17
/RFDWHJUHHQWXEHDWWDFKHGWRWKH520RGXOH,QVHUWWKHRSHQ
HQGRIWKHJUHHQ´WXEHLQWRWKHRSHQ´TXLFNFRQQHFW¿WWLQJ
on the plastic water feed valve making sure the tube is pushed in
all the way to the tube stop.
Step 19
Red 1/4” Tube Connection (from faucet)
8VLQJWKHZKLWHSODVWLFXQLRQIRXQGLQWKHSDUWVEDJGHWHUPLQHZKHUH
the 1/4” red tubing from the faucet and the 1/4” red tubing from the
RO membrane housing would join together comfortably. Cut red tube
IURP52IDXFHWWROHQJWKOHDYLQJDVWUDLJKWFXWHGJH,QVHUWWKHUHG
tube from RO faucet in one end of the white plastic union and the
UHGWXEHIURP52PHPEUDQHKRXVLQJLQWKHRWKHUHQG8VHD´
wrench to tighten both of the white plastic nuts securely.
Green Tube
$GDSWD9DOYH
7HÀRQWDSHPXVWEHDSSOLHGLQDFORFNZLVHGLUHFWLRQ:UDS
WRWXUQVDURXQGWKHPDOHSLSHWKUHDGV037RQWKH
VWDLQOHVVVWHHO¿WWLQJRQWRSRIWKHWDQN
Tank Ball Valve Installation
7KUHDGWKHHOERZEDOOYDOYHVXSSOLHGLQWKHSDUWVEDJ
onto the stainless steel connector on the tank.
Note: Do not over-tighten plastic connections.
Step 20
Step 21
Blue Tube Connection (From The Tank to Shut off Valve)
3RVLWLRQWDQNLQGHVLUHGORFDWLRQ6WDQGLWXSULJKWRUOD\LWRQLWVVLGHXVLQJWKHEODFNSODVWLF
VWDQG0HDVXUHWKHEOXHWXEHPDUNHG³7$1.´IURPWKH52PRGXOHWRWKHWDQNDQGFXWLW
WROHQJWKOHDYLQJDVWUDLJKWVTXDUHHGJH7RFRQQHFWWKHEOXHWXEHWRWKHEDOOYDOYH¿WWLQJ
slip the blue tube through the white compression nut, hand tighten the white nut and add 1/4
turn with a wrench.
Step 22
Note:6HWWKHEOXHEDOOYDOYHNQRELQOLQHZLWKWKHEOXHWXEHWKLVLVWKH³RSHQ´SRVLWLRQ
Page 13
Start up Instructions
If you have connected your RO system to a refrigerator / ice maker, make sure the ice maker is
RIIGRQRWDOORZZDWHUWRÀRZWRWKHLFHPDNHUXQWLOÀXVKLQJ6WHSLVFRPSOHWHDQGWKHWDQN
KDVEHHQDOORZHGWR¿OOFRPSOHWHO\&RQQHFWLRQIURPWKH52WRWKHLFHPDNHUV\VWHPVKRXOG
have an in-line valve installed before the ice maker so it can easily be closed to prevent water
ÀRZLQJWRWKHLFHPDNHUGXULQJVWDUWXSDQGSHULRGLFPDLQWHQDQFH<RXUVWRUDJHWDQNPXVWEH
DOORZHGWR¿OOXSIXOO\LQRUGHUIRUWKHLFHPDNHUV\VWHPWRZRUNSURSHUO\
$IWHUWKHVWRUDJHWDQNKDV¿OOHGRSHQWKH52)DXFHWWRÀXVKWKHWDQNFRPSOHWHO\<RXZLOO
NQRZWKDWWKHWDQNLVHPSW\ZKHQWKHÀRZUDWHIURPWKH52IDXFHWLVGRZQWRDWULFNOH5HSHDW
this step two more times. The fourth tank can be used for drinking.
2SHQWKH52IDXFHWDQGOHDYHLWRSHQXQWLOZDWHUEHJLQVWRWULFNOHRXWWKLVPD\WDNHDIHZ
PLQXWHVDQGWKHZDWHUZLOOFRPHRXWVORZO\
Step 4
Turn on the incoming cold water at the angle stop valve and the
$GDSWD9DOYH&KHFNWKHV\VWHPIRUOHDNVDQGWLJKWHQDQ\¿WWLQJV
DVQHFHVVDU\&KHFNIUHTXHQWO\RYHUWKHQH[WKRXUVWRHQVXUH
QROHDNVDUHSUHVHQW
Step 3
Step 2
Note:
Step 1
&ORVHWKH52IDXFHWDOORZLQJWKHVWRUDJHWDQNWR¿OOZLWKZDWHU,WPD\WDNHWRKRXUVWR
¿OOWKHWDQNFRPSOHWHO\GHSHQGLQJRQWKHSURGXFWLRQFDSDELOLW\RIWKHPHPEUDQHORFDOZDWHU
temperature and water pressure.
Flushing of the tank 3 times is only necessary during the initial startup and after replacing the
membrane.
'XULQJWKH¿OOSHULRG\RXPD\KHDUZDWHUWULFNOLQJZKLFKLVDQRUPDORFFXUUHQFH
Note:
Note:
&RQJUDWXODWLRQV
<RXKDYHFRPSOHWHGWKHLQVWDOODWLRQRI\RXUQHZ5HYHUVH2VPRVLVV\VWHP
3OHDVH)ROORZWKH6WDUWXS,QVWUXFWLRQV
7KHÀXVKLQJSURFHVVVKRXOGWDNHDERXWDGD\WRFRPSOHWH
ON
Page 14
6 Month System Maintenance
Step 1
Step 3
2SHQ52)DXFHWWRGHSUHVVXUL]HV\VWHPEHIRUHDWWHPSWLQJWRUHPRYH¿OWHUKRXVLQJVWKLV
may take a few minutes.
Items needed:
6WDJH6HGLPHQW)LOWHUSDUW
6WDJH&DUERQ%ORFN)LOWHUSDUW:KLWH(QG&DSV
Note:
7KH¿OWHUZUHQFKSLFWXUHG3DUWPD\EHSXUFKDVHGIURP3UH-
PLHUWRDLGZLWKWZLVWLQJRII¿OWHUKRXVLQJVQRWUHTXLUHG
Turn off the incoming water supply to the RO at the feed water valve.
)ROORZWKHJUHHQWXEHDZD\IURPWKH52V\VWHPWR¿QGWKHYDOYH
Close the tank Ball valve.
Step 2
)RUPRUHOHYHUDJH\RXPD\OHDYHWKH52PRGXOHDWWDFKHGWRZDOORI
FDELQHW,I\RXDUHXQDEOHWRDFFHVVWKHPRGXOHZKLOHLWLVPRXQWHG
UHPRYHLWSULRUWRFKDQJLQJ¿OWHUV6WDUWLQJZLWKWKHFORVHVWKRXVLQJ
6WDJHUHPRYHLWE\WXUQLQJLWFORFNZLVHOHIWHPSW\ZDWHUWKHQ
GLVFDUG¿OWHU&RQWLQXHRQWRWKH
nd
KRXVLQJ6WDJHDQG
rd
housing
6WDJH
Step 4
&OHDQWKH¿OWHUKRXVLQJVERZOVZLWKDPLOGVRDSVROXWLRQDQGULQVH
with water. Check O-rings and lubricate with water soluble lubricant.
KY Jelly
® or other water based lubricants may be used. Petroleum
based lubricants (such as Vaseline®) must not be used.
Step 5
%HIRUHUHLQVWDOOLQJWKH¿OWHUERZOVEDFNRQWRWKHV\VWHPFKHFN2
rings to make sure they are still in place. *
Caution:
Note:
If you own a four stage system it will not have the third stage.
A four stage system has two vertical housings instead of three.
,QVHUWDQHZVHGLPHQW¿OWHUFORWKOLNHDSSHDUDQFHLQWRWKHVW¿OWHU
KRXVLQJZKLFKLVWKHRQHRQWKHZDWHULQOHWVLGHJUHHQWXELQJIURP
WKHIHHGZDWHUYDOYHRIWKH52V\VWHPDQGUHLQVWDOOKRXVLQJ
Step 6
,QVHUWWKHQHZ&DUERQ%ORFN¿OWHU:KLWHHQGFDSVSODVWLFQHWWLQJ
LQWRWKHVHFRQGDQGWKLUG¿OWHUERZOVDQGUHLQVWDOOKRXVLQJV
Step 7
Step 8
Turn on the water supply to the unit at adapt-a-valve.
.HHSWKH52IDXFHWRSHQXQWLOZDWHUEHJLQVWRWULFNOHRXWLWZLOOFRPH
RXWVORZO\
Step 10
Step 9
Close the RO faucet and open tank ball valve.
2UGHU¿OWHUVE\FDOOLQJRUEX\RQOLQHDWZZZSUHPLHUKRFRP
*
Loosen
OFF
0$,17(1$1&(7528%/(6+227,1*
Page 15
Annual Maintenance
¥6WDJH6HGLPHQW)LOWHU31 ¥6WDJH´)LQDO3ROLVKLQJ,QOLQHILOWHU
¥6WDJH&DUERQ%ORFN)LOWHU31  31
¥&XSRIFRPPRQKRXVHKROGEOHDFK
NOTICE: Sanitizing of unit is recommended - RO storage tank must be drained.
6WHS 3HUIRUPVWHSVWKURXJKLQWKH6L[0RQWK6\VWHP0DLQWHQDQFH3DJH
NOTICE: If not sanitizing the system, skip to step 11
6WHS 5HPRYHWKH52PHPEUDQHIURPLWVKRXVLQJDQGUHVWLQDFOHDQVDQLWDU\SODFH5HIHU
WR³0HPEUDQH5HSODFHPHQW´VHFWLRQRQSDJHIRUGLUHFWLRQVRQUHPRYLQJWKHPHP-
EUDQH5HSODFHFDSRQWRHPSW\PHPEUDQHKRXVLQJDQGUHFRQQHFWJUHHQWXELQJ
6WHS /HDYLQJWKHILOWHUVRXWUHSODFHVWDJHHPSW\ILOWHUKRXVLQJKDQGWLJKWRQWRXQLW
0HDVXUHSRXUFXSRIFRPPRQKRXVHKROGEOHDFKLQWRWKHVWILOWHUKRXVLQJ6WDJH
DQGKDQGWLJKWHQRQWRXQLW
DANGER
!
,)%/($&+*(76,1(<(6+ROGH\HRSHQDQGULQVHVORZO\DQGJHQWO\ZLWKZDWHU
IRUPLQXWHV5HPRYHFRQWDFWOHQVHVLISUHVHQWDIWHUWKHILUVWPLQXWHVWKHQ
continue rinsing eye. Call a poison control center or doctor for treatment advice.
6WHS :LWKWKH52IDXFHWLQWKHFORVHGSRVLWLRQWXUQRQWKHLQFRPLQJZDWHUVXSSO\WRWKH
system by turning the adapt-a-valve counter clockwise. Let the unit fill with water
DSSUR[LPDWHO\PLQXWHVDOORZLQJWKHEOHDFKWRGLOXWH
Step 5: Let the system sit idle for 1 minute
Step 6: Drain the system completely
6WHS /HWWKHV\VWHPILOODJDLQDSSUR[LPDWHO\PLQXWHVDQGVLWLGOHIRUPLQXWHVEHIRUH
draining the system again.
Step 8: Turn off the incoming water at the adapt-a-valve and open the faucet to make sure all
the water has been drained
Step 9: Open the membrane housing and re-install the RO membrane while making sure not to
NLQNWKH2ULQJV5HIHUWR³0HPEUDQH5HSODFHPHQW´VHFWLRQRQSDJHIRUGLUHFWLRQV
RQLQVWDOOLQJWKHPHPEUDQH7LJKWHQWKHFDSEDFNRQWKHKRXVLQJDQGUHFRQQHFWJUHHQ
tubing.
Step 10: Remove filter housings Stage 1, 2 and 3 and empty water.
NOTICE: Before re-installing the filter bowls back on to the system , check O-rings to
make sure they are still in place and lubricate with water soluble lubricant.
6WHS ,QVHUWWKHQHZVHGLPHQWILOWHUFORWKOLNHDSSHDUDQFHLQWRWKHVWILOWHUKRXVLQJZKLFKLV
WKHRQHRQWKHZDWHULQOHWVLGHJUHHQWXELQJIURPWKHDGDSWDYDOYHRIWKH52V\VWHP
and re-install housing.
6WHS ,QVHUWWKHQHZ&DUERQ%ORFNILOWHU:KLWH(QG&DSVLQWRWKHQGDQGUGKRXVLQJDQG
re-install housing.
Step 13: The final in-line filter is located on the blue tube between the storage tank and the RO
faucet. Remove it by loosening the compression fittings on both ends of the filter and
UHSODFHZLWKQHZILOWHU'LVFDUGXVHGILQDOILOWHUDIWHUVDQLWL]LQJ
127,&( 7KHDUURZRQWKH¿QDO¿OWHUPXVWEHSRLQWLQJWRZDUGVWKH52IDXFHWDZD\IURP
SANITATION STEPS
Page 16
Membranes have a life expectancy between 2 and 5 years, depending on the incoming water
conditions and the amount the RO system is used. This reverse osmosis membrane is critical for
HIIHFWLYHUHGXFWLRQRIWRWDOGLVVROYHGVROLGV7'67KHSURGXFWZDWHUVKRXOGEHWHVWHGSHULRGLFDOO\WR
verify that the system is performing satisfactorily.
1RUPDOO\DPHPEUDQHZRXOGEHUHSODFHGGXULQJDVHPLDQQXDORUDQQXDOILOWHUFKDQJH+RZHYHULI
at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis
water, it could be time to replace the membrane. Premier recommends replacing the membrane
when TDS reduction falls below 75%.
NOTE: A water sample may be sent to Premier for a free diagnosis of your membrane
performance. To send a water sample, use two (2) clean containers and fill ½ cup of tap
water in one container and ½ cup of reverse osmosis water in 2nd container. Clearly label
each sample. Send the samples to the address listed on the cover of this manual attention
“Water Samples”. Premier will test the water and mail or call you with the results.
Step 1: Turn off the incoming water supply to the RO system.
6WHS 2SHQWKH52)DXFHWDQGDOORZZDWHUWRGUDLQIURPWKHWDQNXQWLO
it is completely empty.
Step 3: Disconnect the green tube from the elbow on the end cap of the
membrane housing.
Removing the membrane:
Step 4: Remove the end cap from the membrane housing by turning it
counter clockwise to loosen.
6WHS 8VLQJDSDLURISOLHUVJULSWKH39&WXEHRIWKH52PHPEUDQH
and pull firmly on the membrane to remove from the housing and
discard.
Installing the membrane:
Step 6: Lubricate the O-rings on the new membrane with a water soluble
OXEULFDQWVXFKDV.<-HOO\,QVHUWWKHHQGZLWKWKHWZREODFN
O-rings on the PVC tube first into the housing.
Step 7: Once membrane has been inserted into the housing you must take your thumbs and give
a firm push to properly seat the membrane. Replace membrane housing cap and tighten.
Step 8: Re-attach the green tube to the elbow fitting on the end cap of the membrane housing.
6WHS )ROORZWKH6WDUW8S,QVWUXFWLRQVRQSDJH
Membrane Replacement
7KLVUHYHUVHRVPRVLVV\VWHPFRQWDLQVDUHSODFHDEOHFRPSRQHQWWKH52PHPEUDQHZKLFKLVFULWL-
FDOWRWKHHI¿FLHQF\RIWKHV\VWHP5HSODFHPHQWRIWKLVUHYHUVHRVPRVLVPHPEUDQHVKRXOGEHZLWK
RQHRILGHQWLFDOVSHFL¿FDWLRQVDVGH¿QHGE\3UHPLHUWRDVVXUHWKHVDPHHI¿FLHQF\DQGFRQWDPLQDQW
reduction performance.
the RO storage tank.
TIP: This is a good time to check the air pressure in your storage tank. For instruc-
tions please see page 17.
6WHS )ROORZ6WHSVWKURXJKLQWKH6L[0RQWK6\VWHP0DLQWHQDQFH3DJHIRUVWDUWXS
directions.
Page 17
Once all water in the tank is purged, check air pressure using an air pressure gauge, it should
UHDGEHWZHHQ36,'LJLWDODLUSUHVVXUHJDXJHLVUHFRPPHQGHG
Check Air Pressure in the Tank
Important:
Step 3
Check air pressure only when tank is empty of water!
Step 1
Turn off the incoming water supply to the RO.
2SHQWKH52)DXFHWDQGDOORZZDWHUWRGUDLQIURPWKHWDQNXQWLO
it is completely empty.
Step 2
Check air pressure in the storage tank when you notice a decrease in available water from
the RO system. Air can be added with a bicycle pump using the schrader valve that is located
on the lower side of the tank behind the blue plastic cap.
Tip:
When water from the RO faucet slows to a trickle, with the faucet still in the open posi-
tion, you may add air to the tank to purge any left over water, this will ensure that the
tank is completely empty.
Procedure for Extended Non-Use (More than 2 months)
7XUQRIIWKHZDWHUVXSSO\DQGRSHQWKH52IDXFHWWRHPSW\WKHVWRUDJHWDQN6DYHDIHZ
RXQFHVRI52ZDWHU2QFHWKHVWRUDJHWDQNLVHPSW\UHPRYHWKHPHPEUDQHDQGSODFHLWLQ
a sealed plastic bag with the RO water saved earlier and store in your refrigerator.
'2127)5((=(
)RUUHVWDUWUHLQVWDOOPHPEUDQH6HHSDJHIRUPHPEUDQHLQVWDOODWLRQSURFHGXUHDQGIROORZ
startup procedure on page 13.
Step 4
)ROORZVWDUWXSSURFHGXUHRQSDJH
Page 18
TROUBLE SHOOTING
Problem Cause Solution
/RZ6ORZ3URGXFWLRQ /RZ:DWHU3UHVVXUH $VVXUHDPLQLPXPRISVLLQFRPLQJZDWHUSUHVVXUH
Premier sells a booster pump if home water pressure is
low. Make sure water supply is turned on and feed water
valve is all the way open.
Crimps in tubing Check tubing and straighten or replace as necessary.
&ORJJHGSUH¿OWHUV 5HSODFHSUH¿OWHUV
)RXOHGPHPEUDQH 5HSODFHPHPEUDQH
0LON\FRORUHG:DWHU $LULQV\VWHP $LULQWKHV\VWHPLVDQRUPDORFFXUUHQFHZLWKLQLWLDO
start up of the RO system. This milky look will
GLVDSSHDUGXULQJQRUPDOXVHZLWKLQZHHNV,I
FRQGLWLRQUHRFFXUVDIWHU¿OWHUFKDQJHGUDLQWDQNWR
times.
:DWHUFRQVWDQWO\ /RZZDWHUSUHVVXUH 6HH$ERYH
running, unit will not
shut off Crimp in supply tube Check tubing and straighten or repair as necessary.
High water pressure Check incoming water pressure to make sure it does
not exceed 80 psi. A pressure relief valve may be
necessary.
High pressure in Tank Empty storage tank of water. Set tank air pressure
between 5-7 psi. See previous page.
/RZ3UHVVXUHLQ7DQN  8VHD'LJLWDO$LU*DXJHIRUEHVWUHVXOWV7KHHPSW\
tank pressure should be 5-7 psi. See page 78.
1RLVH:DWHUIURPIDXFHW&ULPSRUUHVWULFWLRQ &KHFNWXELQJDQGVWUDLJKWHQRUUHSDLUDVQHFHVVDU\
vent hole or noise from in drain line Straighten all drain lines. Clear blockage. Cut off any
drain. Excess tubing
Drain tube clogged Caused from dishwasher or garbage disposal.
Disconnect the 3/8” black line at the drain, clean the
3/8” black line out with a wire, then reconnect. Blowing
air through the line will not always remove the clog.
6PDOODPRXQWRIZDWHULQ 6\VWHPVWDUWLQJXS 1RUPDOO\LWWDNHVKRXUVWR¿OOWDQN1RWHORZ
storage tank incoming water pressure and/or temperature can
drastically reduce production rate.
/RZZDWHUSUHVVXUH 6HHDERYH
To much air in tank Tank air pressure should be 5-7 psi when empty of water.
,IEHORZSVLDGGDLURUEOHHGLIDERYHSVL
Check only when tank is empty of water.
See previous page.
:DWHUOHDNVIURPWKHEOXH 1RWSURSHUO\WLJKWHQHG 7LJKWHQWKHERZO
RUZKLWH¿OWHUKRXVLQJ .LQNHG2ULQJ 7XUQRIIWKHZDWHUVXSSO\DQGUHOHDVHWKHSUHVVXUH
Replace the O-ring if necessary. Then lubricate it and
PDNHVXUHWKH2ULQJLVVHDWHGLQWKH¿OWHUERZO
SURSHUO\EHIRUHUHLQVWDOOLQJWKH¿OWHUERZO
/RZZDWHUÀRZIURPIDXFHW &KHFNDLUSUHVVXUHLQWDQN 8VHD'LJLWDO$LU*DXJHIRUEHVWUHVXOWV7KHHPSW\
tank pressure should be 5-7 psi. See page 17.
Page 19
5(&200(1'('5(3/$&(0(173$576$1'&+$1*(,17(59$/6
1RWH'HSHQGLQJRQLQFRPLQJIHHGZDWHUFRQGLWLRQVUHSODFHPHQWWLPHIUDPHPD\YDU\
Description Change time Frame
6HGLPHQW3UH¿OWHU  0RQWKV
&DUERQ3UH¿OWHU  0RQWKV
)LQDO&DUERQ¿OWHU  0RQWKV
520HPEUDQH  WR\HDUV
Depending on water chemistry, water temperature, and water pressure Premiers R.O. Systems production and performance will vary.
(I¿FLHQF\UDWLQJPHDQVWKHSHUFHQWDJHRIWKHLQÀXHQWZDWHUWRWKHV\VWHPWKDWLVDYDLODEOHWRWKHXVHUDVUHYHUVHRVPRVLVWUHDWHGZDWHUXQGHU
RSHUDWLQJFRQGLWLRQVWKDWDSSUR[LPDWHW\SLFDOGDLO\XVDJH5HFRYHU\UDWLQJPHDQVWKHSHUFHQWDJHRIWKHLQÀXHQWZDWHUWRWKHPHPEUDQHSRUWLRQRI
the system that is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage
tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY INFORMATION.
3KRQH)D[ZZZ3UHPLHU+RFRP
*(1(5$/86(&21',7,216
1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that
LVPLFURELRORJLFDOO\XQVDIHRUXQNQRZQTXDOLW\ZLWKRXWDGHTXDWHGLVLQIHFWLRQEHIRUHDQGDIWHUWKHV\VWHP6\VWHPVFHUWL¿HGIRUF\VWUHGXFWLRQPD\EHXVHGRQ
GLVLQIHFWHGZDWHUWKDWPD\FRQWDLQ¿OWHUDEOHF\VWV
2SHUDWLQJ7HPSHUDWXUH 0D[LPXP)& 0LQLPXP
2SHUDWLQJ:DWHU3UHVVXUH 0D[LPXPSVLNJFP 0LQLPXPSVLNJFP
S+ WR
0D[LPXPLURQSUHVHQWLQLQFRPLQJIHHGZDWHUVXSSO\PXVWEHOHVVWKDQSSP
+DUGQHVVRIPRUHWKDQJUDLQVSHUJDOORQSSPPD\UHGXFHPHPEUDQHOLIHH[SHFWDQF\
5HFRPPHQG7'67RWDO'LVVROYHG6ROLGVQRWWRH[FHHGSSP
Watts Premier
8716 W Ludlow Drive Suite #1
Peoria, AZ 85381
5 SV Deluxe, CRO-TFM-5SV, Ultra 5 and Pur-Tek, Premier 25, Premier RO-4, Premier RO-5, RO-TFM-4SV, RO-TFM-5SV
6\VWHPFRQIRUPVWR16)6WDQGDUGIRUVSHFL¿FFODLPV
7KLVV\VWHPKDVEHHQWHVWHGDFFRUGLQJWR16)$16,IRUUHGXFWLRQRIWKHVXEVWDQFHVOLVWHGEHORZ7KHFRQFHQWUDWLRQRIWKHLQGLFDWHGVXEVWDQFHVLQZDWHU
HQWHULQJWKHV\VWHPZDVUHGXFHGWRDFRQFHQWUDWLRQOHVVWKDQRUHTXDOWRWKHSHUPLVVLEOHOLPLWIRUZDWHUOHDYLQJWKHV\VWHPDVVSHFL¿HGLQ16)$16,7KLV
V\VWHPKDVEHHQWHVWHGIRUWKHWUHDWPHQWRIZDWHUFRQWDLQLQJSHQWDYDOHQWDUVHQLFDOVRNQRZQDV$V9$VRUDUVHQDWHDWFRQFHQWUDWLRQVRIPJ/RU
less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free
chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
FKORULQHLVQRWVXI¿FLHQWWRHQVXUHFRPSOHWHFRQYHUVLRQRIWULYDOHQWDUVHQLFWRSHQWDYDOHQWDUVHQLF3OHDVHVHHWKH$UVHQLF)DFWVVHFWLRQRIWKH3HUIRUPDQFH'DWD
Sheet for further information.
$YJ,Q $YJ(II 5HGXFWLRQ S+ 3UHVVXUH 0D[(II ,QIFKDOOHQJH 0D[$OORZDEOH
(mg/L) (mg/L) mg/L concentration concentration
mg/L mg/L
$UVHQLF3HQWDYDOHQW XJ/ XJ/  SVL XJ/  PJ/
%DULXP5HGXFWLRQ     SVL   
&DGPLXP5HGXFWLRQ     SVL   
&KURPLXP+H[DYDOHQW     SVL   
&KURPLXP7ULYDOHQW     SVL   
&RSSHU5HGXFWLRQ     SVL   
&\VWV PO PO  SVL  PLQLPXPP/ 1$
)OXRULGH5HGXFWLRQ     SVL   
/HDG5HGXFWLRQ     SVL   
5DGLXP S&L/ S&L/   SVL S&L/ S&L/ S&L/
6HOHQLXP    SVL   
7'6     SVL  PJ/ 
7XUELGLW\ 178 178  SVL 178 178 178
5HFRYHU\ 'DLO\3URGXFWLRQ5DWH*3'#: (I¿FLHQF\
* All Prices Subject to change without notice
7(&+1,&$/:$55$17<,1)250$7,21
Page 20
$UVHQLF$VLVDQDWXUDOO\RFFXUULQJFRQWDPLQDQWIRXQGLQPDQ\JURXQGZDWHUV$UVHQLFLQ
ZDWHUKDVQRFRORUWDVWHRURGRU,WPXVWEHPHDVXUHGE\DQDUVHQLFWHVWNLWRUODEWHVW
Public water utilities must have their water tested for arsenic. You can obtain the results from
\RXUZDWHUXWLOLW\FRQWDLQHGZLWKLQ\RXUFRQVXPHUFRQ¿GHQFHUHSRUW,I\RXKDYH\RXURZQ
well, you will need to have the water evaluated. The local health department or the state
HQYLURQPHQWDOKHDOWKDJHQF\FDQSURYLGHDOLVWRIWHVWNLWVRUFHUWL¿HGODEV
7KHUHDUHWZRIRUPVRIDUVHQLFSHQWDYDOHQWDUVHQLFDOVRFDOOHG$V9$VDQGWULYDOHQW
DUVHQLFDOVRFDOOHG$V,,,$V,QZHOOZDWHUDUVHQLFPD\EHSHQWDYDOHQWWULYDOHQWRUD
combination of both. Although both forms of arsenic are potentially hazardous to your health,
trivalent arsenic is considered more harmful than pentavalent arsenic.
RO systems are very effective at removing pentavalent arsenic. A free chlorine residual will
rapidly convert trivalent arsenic to pentavalent arsenic. Other water treatment chemicals
such as ozone and potassium permanganate will also change trivalent arsenic to pentavalent
DUVHQLF$FRPELQHGFKORULQHUHVLGXDODOVRFDOOHGFKORUDPLQHZKHUHLWGRHVFRQYHUWWULYDOHQW
arsenic to pentavalent arsenic, may not convert all the trivalent arsenic in to pentavalent
DUVHQLF,I\RXJHW\RXUZDWHUIURPDSXEOLFZDWHUXWLOLW\FRQWDFWWKHXWLOLW\WR¿QGRXWLIIUHH
chlorine or combined chlorine is used in the water system.
This Premier reverse osmosis system is designed to remove up to 98% of pentavalent arsenic.
,WZLOOQRWFRQYHUWWULYDOHQWDUVHQLFWRSHQWDYDOHQWDUVHQLF8QGHUODERUDWRU\VWDQGDUGWHVWLQJ
FRQGLWLRQVWKLVV\VWHPUHGXFHGPJ/SSPSHQWDYDOHQWDUVHQLFWRXQGHUPJ/
SSPWKH86(3$VWDQGDUGIRUGULQNLQJZDWHU$FWXDOSHUIRUPDQFHRIWKHV\VWHPPD\YDU\
GHSHQGLQJRQVSHFL¿FZDWHUTXDOLW\FRQGLWLRQVDWWKHFRQVXPHU¶VLQVWDOODWLRQ,QDGGLWLRQWR
the independent laboratory standard testing conditions Premier has conducted additional
¿HOGWHVWLQJRQRXUUHYHUVHRVPRVLVXQLWVWRGHWHUPLQHWULYDOHQWDUVHQLFUHGXFWLRQFDSDELOLWLHV
%DVHGXSRQ3UHPLHU¿HOGWHVWLQJLWKDVEHHQGHWHUPLQHGWKDWWKH52XQLWVDUHFDSDEOHRI
reducing up to 67% of trivalent arsenic from the drinking water.
The RO membrane component of this Premier reverse osmosis system must be maintained
DFFRUGLQJWRLWVUHFRPPHQGHGPDLQWHQDQFHF\FOH6SHFL¿FFRPSRQHQWLGHQWL¿FDWLRQDQG
ordering information can be found in the installation/operation manual maintenance section,
by phone at 1-800-752-5582 or online www.premierh2o.com
Arsenic Fact Sheet
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Premier RO-TFM-5SV Installation, Operation and Maintenance Manual

Type
Installation, Operation and Maintenance Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI