York LINC485 is a device that can extend the length of a network or subnetwork beyond the 4000 ft. (1220 m) and 31-node RS485 limitation. It can also be used to divide a network into subnetworks, providing communication management between them and the main network. The LINC485 operates on ISN networks which use Rev. 6, Rev. 7, or UCS software and can be set to operate at a network transfer speed of either 19.2 or 50 kbaud. It has a simple DIP switch setup that facilitates a wide variety of network configurations without the need for a computer interface. The LINC485 also has visual indicators of operating and communication status, making it easy to monitor its performance.

York LINC485

York LINC485 is a device that can extend the length of a network or subnetwork beyond the 4000 ft. (1220 m) and 31-node RS485 limitation. It can also be used to divide a network into subnetworks, providing communication management between them and the main network. The LINC485 operates on ISN networks which use Rev. 6, Rev. 7, or UCS software and can be set to operate at a network transfer speed of either 19.2 or 50 kbaud. It has a simple DIP switch setup that facilitates a wide variety of network configurations without the need for a computer interface. The LINC485 also has visual indicators of operating and communication status, making it easy to monitor its performance.

Universal LINC485 Repeater/Router
Extends network length from 4000 ft.
(1220 m) to 12,000 ft. (3660 m).
Increases network “size” to 92 sub-
networks with over 8000 controllers.
Single device functions as either a
repeater or router, simplifying stock and
inventory requirements.
Simple DIP switch setup facilitates a
wide variety of network configurations
without a computer interface.
DIN rail mounting is standard.
Visual indicators of operating and com-
munication status.
UL916 pending. Complies with relevant
CE EMC and safety directives.
Features and Benefits
The Universal LINC485 Repeater/Router provides a
simple, universal method for segmenting or extending
a YORK ISN Local Area Network (LAN). This small,
economical device can be located exactly where
needed in a small space with minimal setup time and
configuration effort.
By using DIP switches on the device, the Universal
LINC485 may be configured to function as a repeater,
extending the length of the network, or as a router,
dividing the network into subnetworks. The DIP
switches are also used to set the subnetwork address.
The DIP switches eliminate the need to connect a
computer and set software, as required for many types
of devices.
When functioning as a repeater, the Universal
LINC485 extends a network or subnetwork beyond the
4000 ft. (1220 m) and 31 node RS485 limitation. A
maximum of 2 repeaters per network or subnetwork
allow an overall length of 12,000 ft. and maximum of
92 nodes on a network (91 for a subnetwork).
When functioning as a router, the Universal LINC485
provides communication management between sub-
networks and the main network. Packet information is
not transferred beyond the Universal LINC485 unless
a different subnetwork is addressed. This limits the
overall traffic throughout the network by keeping
“local” data within the local sub-network.
Connection to the LAN is completed using a twisted-
pair, shielded cable attached to individual screw
terminals. 5 VDC power can be supplied from either
an optional power supply or directly from the network,
if located within 3 ft. (1 m) of a newer controller
equipped with a USB-style connector.
When located in a more remote location, a separate
5 VDC Power Supply is available for connection to a
115/230 VAC power source. DIN rail mounting is
standard for the Universal LINC485 as well as the
optional Power Supply. For additional versatility, the
LINC may be attached directly to the Power Supply
and the assembly mounted on a DIN rail or fixed
directly to a panel.
The Universal LINC485 operates on ISN networks
which use Rev. 6, Rev. 7, or UCS software. A DIP
switch sets the Universal LINC485 to operate at a
network transfer speed of either 19.2 or 50 kbaud.
A System Status LED provides information on the
operating condition of the device. Two additional
LEDs at each port provide information concerning the
communication status of each port.
SPECIFICATIONS
Universal LINC485
REPEATER/ROUTER
NEW RELEASE
Form 450.20-S30 (702)
2 YORK INTERNATIONAL
Typical LAN Configuration utilizing Universal LINC485
Base Network 99
Each segment may contain up to 32 nodes.
Each subnetwork may contain 3 segments.
Node 30 Node 32 Node 61 Node 63 Node 91
Subnetwork
Universal
LINC485
Subnetwork
The Base Network may contain a combination of up to 92 subnetworks or
nodes, providing Repeaters are used between segments of 32 RS485 drivers.
Universal
LINC485
Universal
LINC485
Universal
LINC485
Node 31 Node 62
Node 1
Subnetwork
Universal
LINC485
Nodes on the incoming side of a repeater must be lower than the repeater node.
Nodes on the outgoing side of a repeater must be higher than the repeater node.
Universal
LINC485
Universal
LINC485
Repeater
Router
Repeater
Router
Repeater
Repeater
Connection
To provide simple connection the Universal LINC485
uses the same connectors as all YORK ISN control-
lers-a removable, 5-screw press-in connector. In
addition to the screw connector, newer ISN controllers
utilize a USB-style connector. This additional connec-
tor provides a simple method for connecting Universal
LINCs to the controller. If within 3 ft. (1 m) of a new-
style controller equipped with a USB-style LINC port,
sufficient power is provided through the LAN connec-
tion. For installations at greater distances and older
controllers, an optional 5 VDC Power Supply is
available.
Mounting Configurations
The Universal LINC485 provides several mounting
methods for greater installation flexibility. Shipped in
a housing with a DIN rail mounting clip, the unit can
be attached to any open DIN rail space within an
existing controller. If the controller does not use DIN
rail, the Universal LINC can be removed from the
housing and secured inside the controller with small
screws (1/8 in./4 mm or smaller).
If space is unavailable inside the controller enclosure,
a small, auxiliary enclosure is available. The auxiliary
enclosure includes a DIN rail to mount the Universal
LINC and an accompanying 5 VDC Power Supply. (It
also accepts the TDCE controllers.)
YORK INTERNATIONAL 3
Universal LINC485 and Optional Power Supply Mounting Dimensions
3.93 in. (100 mm)
2.75 in. (70 mm)
UNIVERSAL
LINC485
TX
RX
TX
RX
SCREEN
P3
P2
GND
5VDC
GND
P2
P3
USHL
LAN
PORT 2
LAN
PORT 1
STATUS
S1
MODE
1
2
4
8
16
32
64
CS
OFF
ON
0.16 in. (4 mm) dia. (2x)
2.16 in. (55 mm)
on DIN rail
1.00 in. (25 mm)
Panel Mount
S1 LINC
OFF ROUTER
ON REPEATER
MODE SWITCH IS
FOR 50K REPEATER
ONLY. SEE MANUAL
CS OFF 19K2 LAN
CS ON 50K LAN
5VDC
Universal LINC485 with Optional Power Supply
Mounted in Optional DIN Rail Box
5 VDC Power Supply
The optional 5 VDC Power Supply takes advantage of
the same flexibility included with the Universal LINC.
Shipped within the same style housing, it also includes
a DIN rail mounting clip. If space allows it may be
clipped to a DIN rail inside a controller enclosure. If
space is at a premium, the Universal LINC can be
removed from the housing and attached to the top of
the power supply in “piggy-back” fashion. Both items
can then be attached to a DIN rail, requiring a smaller
foot-print.
If DIN rails are not available, the 5 VDC Power
Supply can be removed from the housing and attached
directly to a panel. And, as mentioned previously, it
can also be installed inside the auxiliary enclosure
alongside the Universal LINC.
SPECIFICATIONS
General Primary Power Source 5 VDC, (±5%)
Frequency N/A
Power Consumption Nominal 180 mA; Limited to 250 mA
Storage Temperature -40 to 160° F (-40 to 70° C)
Operating Environment 32 to 122° F (0 to 50° C)
10 to 95% RH non-Condensing
Size (H x W x D) 3.93 x 2.75 x 2.17 in. (100 X 70 X 55 mm) on DIN rail
Weight 0.44 lb. (0.20 kg)
Electrical Processor NEC V25 operating at 8 MHz
Memory PROM 256 kbytes
Memory RAM 128 kbytes
User Functions Port 1 RS485 LAN Port/USB Cable
Port 2 RS485 LAN Port
Terminations Removable Terminal Strips. Max Cable Size 16 AWG (1.5 mm² CSA)
Status LEDs System Status; Port 1 LAN Status; Port 2 LAN Status
Switch Selections Device Type; Mode Selection; Node Address (1-98); LAN Transfer Rate
Network Cable Shielded, Twisted-Pair (Belden 9272 or Equivalent)
Optional Power Supply Kit 115/230 VAC (±10%)
Frequency 50/60 Hz (±10%)
Power Consumption Nominally 2 VA
Maximum Power Output 300 mA
Size (H x W x D) 3.78 x 3.66 x 2.95 in. (96 X 93 X 75 mm) on DIN rail
Weight 1.1 lb. (0.5 kg)
Optional USB Cable USB-Style Connector to 5-Pin Push-in Connector
Cable Length 39 in. (1 m)
Ordering Information
Universal LINC485 371-04138-002
5 VDC Power Supply (115 VAC Input) 371-04130-001
5 VDC Power Supply (230 VAC Input) 371-04130-002
Patch Cable 371-01429-000
Small Enclosure with DIN Rail 371-04131-000
Agency UL 916 Pending
FCC Part 15 Conducted and Radiated
LVD Standard EN60950
Emission Standard EN55022; 1994 Class A
CE (Satisfying all the relevant EMC directives) and IEC950/EN60950 (Safety directive)
P.O. Box 1592, York, Pennsylvania USA 17405-1592 Unit 1, Red Shute Hill, Hermitage, Newbury, Berks RG18 9QL United Kingdom
Tele. 800-861-1001 website: www.york.com Tele: +44 (0)1635 202200 e-mail: controls[email protected]
Copyright © by York International Corporation 2002 Subject to change without notice. Printed in USA
Form 450.20-S30 (702) ALL RIGHTS RESERVED
New Release
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

York LINC485 User manual

Category
Bridges & repeaters
Type
User manual

York LINC485

York LINC485 is a device that can extend the length of a network or subnetwork beyond the 4000 ft. (1220 m) and 31-node RS485 limitation. It can also be used to divide a network into subnetworks, providing communication management between them and the main network. The LINC485 operates on ISN networks which use Rev. 6, Rev. 7, or UCS software and can be set to operate at a network transfer speed of either 19.2 or 50 kbaud. It has a simple DIP switch setup that facilitates a wide variety of network configurations without the need for a computer interface. The LINC485 also has visual indicators of operating and communication status, making it easy to monitor its performance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI