Currys Essentials C10DH19 User manual

Type
User manual
Safety Warnings
For your continued safety and to reduce the risk of injury or electric shock, please
follow all the safety precautions listed below.
Read all instructions carefully before using the unit and keep them for future
reference.
Retain the manual. If you pass the unit onto a third party, make sure to include this
manual.
Make sure your home voltage matches the voltage displayed on the appliance. If
you are not sure, contact an electrician.
Do not use the appliance in the bathroom or shower room.
Do not place unit appliance near radiators or heating appliances, also do not
operate the unit in direct sunlight.
Do not use the unit near ammable materials or re.
Close supervision is required when the unit is used by or near children.
Ensure that the unit is used on a stable and level surface. If the oor surface is
uneven there is a risk that the appliance could tip over. Also, excessive vibration
and noise may occur.
If the appliance tips over, immediately disconnect from the power supply.
Do not block or restrict the airow around the appliance. Position the unit so that
the air inlet and exhaust grilles are not blocked or restricted in anyway.
Allow 300mm of clearance around the unit.
Do not spray water on the unit as this may cause irreparable damage to the unit
and the risk of electric shock.
Do not unplug the unit from the mains socket with wet hands.
Switch o the power before removing the plug from the mains socket.
To disconnect the power, grip the plug and pull it out from the mains socket.
NEVER pull the mains cable.
Empty the water when the water tank is full or the unit is not in use for a
prolonged period.
Do not push any objects in the air inlet and exhaust grilles.
This appliance is intended for indoor household use and similar applications such
as:
farm houses and by clients in hotels, motels and other residential type
environments;
bed and breakfast type environments;
catering and similar non-retail applications.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not
play with the appliance.
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualied persons in order to avoid a hazard.
WARNING
IT IS HAZARDOUS FOR ANYONE OTHER THAN AUTHORISED SERVICE PERSONNEL
TO CARRY OUT SERVICING OF REPAIRS WHICH INVOLVE THE REMOVAL OF
COVERS.
TO AVOID THE RISK OF AN ELECTRICAL SHOCK DO NOT ATTEMPT REPAIRS
YOURSELF.
10L DEHUMIDIFIER
Instruction Manual
C10DH19
DSG Retail Ltd. (co. no. 504877)
1 Portal Way, London, W3 6RS, UK
EU Representative
DSG Retail Ireland Ltd (259460)
3rd Floor Oce Suite, Omni Park SC
Santry, Dublin 9, Republic of Ireland
The symbol on the product or its packaging indicates that this product
must not be disposed of with your other household waste. Instead, it
is your responsibility to dispose of your waste equipment by handing
it over to a designated collection point for the recycling of waste
electrical and electronic equipment. The separate collection and
recycling of your waste equipment at the time of disposal will help
conserve natural resources and ensure that it is recycled in a manner
that protects human health and the environment.
For more information about where you can drop o your waste for
recycling, please contact your local authority, or where you purchased
your product.
All trademarks are the property of their respective owners and all rights are
acknowledged.
IB-C10DH19-190531V1
Visit Partmaster.co.uk today for the easiest way to buy
electrical spares and accessories. With over 1 million spares
and accessories available we can deliver direct to your door
the very next day. Visit www.partmaster.co.uk or call 0344
800 3456 (UK customers only). Calls charged at National Rate.
For general information about this appliance
and handy hints and tips, please visit
www.knowhow.com/knowledgebank or call 0344 5611234.
Specications
Model C10DH19
Power Supply 220-240V ~ 50Hz
Dehumidification 10 L
Power Input 210 W (30ºC 80% RH)
Rated Power 280 W (35ºC 90% RH)
Capacity of Water Tank 1.8 L
Refrigerant R290 (55 g)
Net Weight 9.6 kg
Dimension (W x D x H) 290 × 190 × 478 mm
Features and specications are subject to change without prior notice.
Thank you for purchasing your new product.
We recommend that you spend some time reading this instruction manual in
order that you fully understand all the operational features it oers.
Read all the safety instructions carefully before use and keep this instruction
manual for future reference.
The appliance shall be installed in accordance with national wiring regulations.
For correct installation of the appliance, the minimum permissible distances to
adjacent structures is 30 cm.
Type and rating of fuses:
PCB fuse: 2010 Serie(s) AC250V; T, 3,15 A; or 5A or 6,3A L (Fuse)
2010 Serie(s) AC250V; T, 2,0 A, L (Fuse 1)
Plug fuse: BS 1362, 13 A
The appliance shall be installed, operated and stored in a room with a oor area
larger than 4 m
2
.
Maximum refrigerant charge amount: 55 g
C10DH19_IB_Final190531V1.indd 1-3 03/06/2019 17:18
Product Overview
Front View
Unpacking
Remove all items from the packaging. Retain the packaging. If you dispose of it
please do so according to local regulations.
The following items are included:
The Main Unit
Instruction Manual
Rear View
Mains Cable
Handle
Removable Water Tank
Air Filter
Control Panel
Before Use
1. Place on a stable, at oor. If the oor surface is not even:
Vibration and noise will occur.
Water may leak from the water tank.
2. Make sure the air openings are clear and free from blockage.
Operation
1. Connect to the mains socket.
2. Press
to switch the unit on or o.
3. Open the air outlet ap. Remember to close the ap when not using the unit.
4. Press
repeatedly to set the desired room humidity. When the environment
humidity is lower than the set humidity, the unit will stop automatically. You
can also select to dehumidify continuously by selecting “CONT.
5. If you need to set auto shut o, press
repeatedly.
Water Tank Full
When the water tank is full, the unit will beep. The WATER FULL indicator will
illuminate and the unit will automatically stop operating.
Turn o the unit and remove the water tank.
Empty the water and then ret the water tank.
Turn the unit on again to continue operation.
Auto-Defrost
When using the appliance in low temperature environments, frost may build
up inside the unit. The unit has an automatic defrosting function and will
automatically activate defrost mode. The DEFROST indicator will illuminate.
Continuous Draining
Water can be automatically emptied
into a oor drain by attaching a water hose (not
included) to the unit.
Insert the water hose (not included)
into the drain outlet as shown. Place or connect
the other end of the hose to a suitable
drainage facility.
Cleaning & Maintenance
Maintenance of your air lter
The air lter of the unit collects dust contained in the air. The build up of dust
reduces the eciency of the unit. To prevent the dust from clogging up the unit,
always use it with the air lter in place.
Always clean the air lter every 2 weeks. If the unit is used in a dusty atmosphere,
clean the air lter more often.
Remove the air lter.
Clean the air lter with a vacuum cleaner. lf the air lter is very dirty, you can
wash it in warm water (never use hot or soapy water). Make sure that the air
lter is dry and retted correctly. Do not bend the lter and ensure it is tted
before operating the unit.
Cleaning the unit
Clean the unit using a damp sponge, and dry it with a clean, soft cloth.
Never use alcohol or any product containing solvents.
Do not immerse the unit in water.
Issue Solution
The WATER FULL indicator is
illuminated.
Empty the water tank.
Refit the water tank in correct position.
Dehumidifying function does not work. Humidity level in the room may be too low.
Air filter may be dirty; clean the air filter.
Make sure that the air openings are not
obstructed.
Excessive noise. Ensure the unit is on a stable flat surface.
Clean the air filter.
No air coming out from the air outlet. Clean the air filter.
Control Panel
Air Outlet Flap
Drain Outlet
Turn the unit on
and o.
Select the auto shut
o function (select
from 2/4/6 hours.)
Illuminates when
the unit enter
defrost mode.
Select the desired
room humidity
(40%/50%/60%)
or continuous
dehumidication
(CONT).
Illuminates when
the water tank is full.
Water Hose
Drain
Outlet
Suitable Environments
This unit is designed to operate in the following ambient room conditions:
• Minimum: 5ºC, 40%RH
Maximum: 35ºC, 90%RH
It is suitable for use in bedrooms, studies, cellars/basements, kitchens, storage
rooms, libraries, galleries and computer rooms.
It is also suitable for use to protect moisture-sensitive items, such as most musical
instruments, cameras and computers.
Benets:
Protects clothes and leather products from becoming mouldy.
Dehumidies ooring and carpets.
Prevents ceiling and windows from condensation.
The hose level must be lower than the drain outlet, see diagrams below. When
the hose is not being used, remove the hose from the drain outlet.
To obtain the best results, avoid opening windows and doors.
The unit is equipped with compressor protection. If the unit has been switched
o and needs to be switched on again immediately, the compressor will delay
3 minutes to start up.
If items are missing or damaged, please contact Partmaster (UK only).
Tel: 0344 800 3456 for assistance.
C10DH19_IB_Final190531V1.indd 4-6 03/06/2019 17:18
  • Page 1 1
  • Page 2 2

Currys Essentials C10DH19 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI