Currys Essentials C10DHW11 User manual

Type
User manual
GB-4
1 0 L I T R E D E H U M I D I F I E R
INSTRUCTION MANUAL
C10DHW11
Thank you for purchasing your new Currys Essentials
10 Litre Dehumidifier.
We recommend that you spend some time reading this instruction
manual in order to fully understand all the operational features it
offers.
Read all the safety instructions carefully before use and keep this
instruction manual for future reference.
If the unit has been switched o and needs to be switched on again quickly,
allow approximately three minutes for the correct operation to resume.
S A F E T Y F I R S T !
Please follow all the safety precautions listed below for safety and to reduce the
risk of injury or electrical shock.
• Read all the instructions before using the appliance and keep them for future
reference.
• Retain the manual. If you pass the appliance onto a third party make sure to
include this manual.
• Always ensure that your supply voltage matches this appliances rating label.
• Do not use the appliance in the bathroom or shower room.
• Do not place unit appliance near radiators or heating appliances, also do not
operate the unit in direct sunlight.
• Do not use the unit near ammable materials or re.
• Close supervision is required when the unit is used by or near children.
• Ensure that the unit is used on a stable and level surface. If the oor surface is
uneven there is a risk that the appliance could tip over. Also, excessive vibration
and noise may occur. If the appliance should be accidentally tipped over,
please immediately disconnect from the power supply.
• Do not block or restrict the airow around the appliance. Position the unit so
that the air inlet and exhaust grilles are not blocked or restricted in anyway.
• Allow 300mm of clearance around the unit.
• Do not spray water on the unit as this may cause irreparable damage to the
unit and the risk of electric shock.
• Do not unplug the unit from the mains socket with wet hands.
• Switch off the power before removing the plug from the mains socket. Grip the
plug and pull it out from the mains socket. NEVER pull the mains cable.
• Empty the water when the water tank is full or the unit is not in use for a
prolonged period.
• Do not push any objects in the air inlet and exhaust grilles.
This unit is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
unit by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the unit.
• If the mains cable is damaged, the unit must be replaced by the manufacturer,
its service agent or similarly qualied persons in order to avoid a hazard.
This appliance is intended for normal indoor household use only.
• Always position the appliance which the main plug in an accessible position.
S P E C I F I C AT I O N S
Power Supply : 230 V / 50Hz
Dehumidication : 10 L / D
Power Consumption : 220W
Air Flow : 130 m3 / hr
Capacity of Water Reservoir : 1.5 L
Specications and features may change without prior notice.
Note : If you require a replacement for any of the items listed below, please quote
their corresponding part numbers:
Replacement Part
Water Hose 202725490014
Water Tank 201126290155
Part Number
GB-5
DSG Retail Ltd • Maylands Avenue • Hemel Hempstead
Herts • HP2 7TG • England
Visit Partmaster.co.uk today for the easiest way to buy
electrical spares and accessories. With over 1 million
spares and accessories available we can deliver direct to
your door the very next day. Visit www.partmaster.co.uk or call 0844 800 3456 (UK
customers only) Calls charged at National Rate.
This symbol on the product or in the instructions means that your
electrical and electronic equipment should be disposed at the end of its
life separately from your household waste. There are separate collection
systems for recycling in the EU. For more information, please contact the
local authority or your retailer where you purchased the product.
(P.N. : 202000191009)
C10DHW11_IB_wait PN_111019.pdf 1 19/10/2011 11:42 AM
GB-1 GB-2
P R O D U C T O V E R V I E W
U N PA C K I N G
Remove all packaging from the unit. Retain the packaging. If you dispose of it
please do so according to local regulations.
The following items are included:
The Main Unit
The Water Hose (P.N.: 202725490014)
The Water Tank (P.N.: 201126290155)
The Instruction Manual (P.N.: 202000191009)
If items are missing or damaged, please contact Partmaster (UK only).
Tel: 0844 800 3456 for assistance.
The unit must stand upright for at least 2 hours prior to use.
When the hose is not being used, remove the hose from the drain outlet.
The hose level must be lower than the drain outlet, see diagrams below.
If the unit has been switched off and needs to be switched on again
quickly, allow approximately three minutes for the correct operation to
resume.
Always press the ON/OFF button to switch the unit off. The unit have
delay function to protect itself if user shut the unit o not properly in
previous operation.
GB-3
B E F O R E U S E
1. Place on a stable, at oor. If the oor surface is not even:
Vibration and noise will occur.
Water may leak from the water tank
2. Make sure the air inlet and air outlet openings are clear and free from blockage.
S TA R T O P E R AT I O N
1. Connect to the mains socket.
2. Press the ON/OFF button to switch the unit on.
3. Press the ON/OFF button to switch the unit o.
WAT E R TA N K F U L L
When the water tank is full, the WATER FULL
indicator will illuminate and the unit will
automatically stop operating. Switch o the unit
and remove the water tank. Empty the water and
then ret the water tank back to the unit. Wait for
approx. 3 min, then switch the unit on again and
continue operation.
CONTINUOUS DRAINING
Water can be automatically emptied into a oor
drain by attaching the unit with a water hose
(13.5mm).
• Remove the rubber plug from the back of the unit.
• Insert the water hose into the unit from the drain
outlet in the back of the unit as shown. Lead the
water hose to a suitable drainage facility.
C L E A N I N G & M A I N T E N A N C E
Maintenance of your air lter
The air lter located inside the air inlet of the unit collects dust contained in the air.
The build up of dust reduces the efficiency of the unit. To prevent the dust from
clogging up the unit always use it with the air lter in place.
Always clean the air lter every 2 weeks. If the
unit operates in a dusty atmosphere clean the air
lter more often.
To remove the lter, pull down the plastic lip at
the bottom of the vents as shown.
• Clean the air lter with a vacuum cleaner. lf the
air lter is very dirty, you can wash it in warm
water (never use hot or soapy water). Make
sure that the air lter is dry and retted
correctly to the unit. Do not bend the lter and
ensure it is tted before operating the unit.
Cleaning the unit
• Clean the unit by using a damp sponge, and dry it with a clean, soft cloth.
• Never use alcohol or any product containing solvents.
• Do not immerse the unit in water.
H I N T S & T I P S
Air Intake
Water Tank
Water Level Window
Water Hose
Air Filter
(behind the air intake)
POWER WATER FULL
Front View
Control Panel
1
3
2
Control Panel
Mains Cable Band
Air Outlet
Handle
Drain Hose Outlet
Rubber Plug
Rear View
Mains Cable
Power Indicator : Illuminates when the unit is in operation.
Water Full Indicator: Illuminates when the water tank is full or not in place.
ON/OFF Button: Press to turn the unit on and o.
1
3
2
S U I TA B L E F O R U S E I N
• Bedrooms • Studies
• Cellars / Basements • Kitchens
• Storage rooms • Libraries
• Galleries • Computer rooms
Protects moisture sensitive items, such as :
• Musical instruments • Cameras
• Computers
Benets:
• Prevents clothes and leather products from moulding.
• Dehumidies ooring and carpets.
• Prevents ceiling and windows from condensation.
To obtain best results, try to avoid opening and closing windows and doors.
Water
Hose
Rubber
Plug
Drain
Outlet
Empty the water tank.
Ret the water tank in correct position.
The WATER FULL indicator
illuminates.
Clean the air lter. Make sure that the air inlet
and the air outlet are not obstructed.
Dehumidifying function
does not work.
Ensure the unit is on a stable at surface.
Clean the air lter.
Excessive noise.
Clean the air lter.No air coming out from the
air outlet.
Problems Solutions
C10DHW11_IB_wait PN_111019.pdf 2 19/10/2011 11:42 AM
  • Page 1 1
  • Page 2 2

Currys Essentials C10DHW11 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI