Data Retrieval
for
Micro-Link and
Micro -Link 2/2i
DataCORDER
OPERATING INSTRUCTIONS
DATA RETRIEVAL
for
MICRO-LINK and MICRO-LINK 2/2i
DataCORDER
Carrier Corporation 2000 D Printed in U. S. A. 0700
Carrier Transicold, Carrier Corporation, P.O. Box 4805, Syracuse, N.Y. 13221 U. S. A.
Carrier Refrigeration Operations, A member of the United Technologies Corporation family. Stock symbol UTX.
i
62--02575--07
TABLE OF CONTENTS
PARAGRAPH NUMBER Page
DESCRIPTION 1-1...............................................................................
1.1 HARDWARE AND SOFTWARE 1-1..................................................
1.2 DataCORDER 1-1.................................................................
1.2.1 Micro-Link 2 Controller/DataCORDER 1-2..........................................
1.2.2 Micro-Link 2i Controller/DataCORDER 1-3.........................................
1.2.3 Micro-Link 1 Controller/DataCORDER 1-4..........................................
1.2.4 DataCORDER C apabilities (Micro-Link 2 and Micro-Link 2i only) 1-5....................
1.3 DataCORDER INTERFACE 1-6......................................................
1.3.1 Data Extraction 1-6.............................................................
1.3.2 Events 1-6....................................................................
1.4 USDA RECORDING 1-10............................................................
1.5 RELATIVE HUMIDITY 1-10.........................................................
SYSTEM SETUP 2-1..............................................................................
2.1 HARDWARE PLATFORMS SUPPORTED 2-1..........................................
2.2 INTERROGATION CABLES 2-1.....................................................
2.3 PRINTER SUPPORT 2-2............................................................
2.3.1 PERSONAL COMPUTER PRINTING CABLE CONNECTIONS 2-2.....................
NOTE
The format of Section Three follows the format of the Help File provided with the DataView program
DataView PROGRAM INSTRUCTIONS 3-1..........................................................
TOPIC 1 SYSTEM REQUIREMENTS 3-1........................................................
Desktop Computer 3-1...................................................................
HP Palmtop Computer 3-1................................................................
Pen--Based Computer 3-1.................................................................
Printers Supported 3-2...................................................................
TOPIC 2 DESKTOP QUICK START 3-2..........................................................
Installation From MS --DOS Prompt 3-2......................................................
Additional Steps For The HP Palmtop 3-3....................................................
Additional Steps For The Pen --based Computer Without A Floppy Drive 3-3........................
Running The Program At The MS--DOS Prompt 3-4...........................................
Changing Program Behavior 3-4...........................................................
TOPIC 3 MENU BASICS 3-4....................................................................
TOPIC 4 RAW FILE CONVERSION 3-5..........................................................
TOPIC 5 MICRO-LINKS SELECTION SCREEN 3-6...............................................
TOPIC 6 MAIN MENU SCREEN 3-7.............................................................
TOPIC 7 INTERROGATION MENU 3-8..........................................................
TOPIC 8 DATAREADER 3-9....................................................................
TOPIC 9 SYSTEM TOOLS 3-10..................................................................
TOPIC 10 CONTROLLER UTILITIES 3-11.........................................................
View/Change Container ID 3-11.............................................................
Control Setpoint 3-12.....................................................................
Control Parameters 3-13...................................................................
Compressor Hour Meter 3-13...............................................................
Configuration 3-13.......................................................................
ii
62--02575--07
TABLE OF CONTENTS (Continued)
PARAGRAPH NUMBER Page
TOPIC 11 CONTROLLER CONFIGURATION 3-14.................................................
Fixed C onfiguration Variables 3-15..........................................................
Custom Controller Configuration 3-16........................................................
TOPIC 12 RECORDER UTILITIES 3-17...........................................................
Trip Functions 3-17.......................................................................
Configuration 3-18.......................................................................
Date And Time 3-19......................................................................
USDA Probe Calibration 3-19..............................................................
Update ISO T rip Header 3-20...............................................................
TOPIC 13 RECORDER CONFIGURATION 3-21....................................................
Standard Configuration 3-22................................................................
Generic Configuration 3-23................................................................
Recorder Sensors 3-24....................................................................
Controller Sensors 3-25...................................................................
TOPIC 14 PROBE CALIBRATION 3-26............................................................
TOPIC 15 CONTROLLER MONITOR 3-27.........................................................
TOPIC 16 PROGRAM SETUP 3-28................................................................
TOPIC 17 DIRECTORY SCREEN 3-29.............................................................
TOPIC 18 PRINTER SETUP 3-30..................................................................
TOPIC 19 VIEW DATA 3-31.......................................................................
TOPIC 20 SENSOR CONFIGURATION 3-32........................................................
TOPIC 21 TEXTUAL DATA 3-33..................................................................
Sensor Data 3-33.........................................................................
Event Data 3-34.........................................................................
Summary Data 3-34......................................................................
Raw Data 3-34..........................................................................
TOPIC 22 GRAPHIC DATA 3-36...................................................................
TOPIC 23 PRINT DATA 3-37......................................................................
OPTIONAL HARDWARE 4-1......................................................................
4.1 DataReader 4-1....................................................................
4.2 OPERATOR INTERFACE 4-1.......................................................
4.3 MENU INTERFACE 4-2............................................................
4.3.1 Transfer Data 4-2...............................................................
4.3.2 F ile Utilities 4-2................................................................
4.3.3 DataSet Files 4-2...............................................................
4.3.4 S et Date/Time 4-3..............................................................
4.3.5 Power Off 4-3..................................................................
4.3.6 Micro-Link 1/2/2i 4-3...........................................................
iii
62--02575--07
LIST OF ILLUSTRATIONS
FIGURE NUMBER Page
Figure 1-1. Micro-Link 2 Controller and DataCORDER 1-2.......................................
Figure 1-2. Micro-Link 2i Controller/DataCORDER 1-3..........................................
Figure 1-3. Micro-Link 1 Controller 1-4.......................................................
Figure 2-1. Communication Cable Connections 2-1..............................................
Figure 2-2. Parallel Printer Cable Connections 2-2...............................................
Figure 2-3. Serial Printer Cable Connections 2-2................................................
Figure 4-1. Hand Held DataReader 4-1........................................................
Figure 4-2. DataReader Menu 4-2............................................................
Figure 4-3. File Utilities 4-2................................................................
Figure 4-4. ML2 Menu 4-3.................................................................
Figure 4-5. Extract Data Menu 4-3...........................................................
Figure 4-6. Command Menu 4-4.............................................................
Figure 4-7. Configure Menu 4-5.............................................................
Figure 4-8. Display Menu 4-5...............................................................
LIST OF TABLES
TABLE NUMBER Page
Table 1-1 DataView Software 1-1.............................................................
Table 1-2. Manual Cross Reference Chart 1-1....................................................
Table 1-3. Temperature Controller Events 1-6....................................................
Table 1-3. Temperature C ontroller Events -- Continued 1-7.........................................
Table 1-4 DataCORDER Events 1-7...........................................................
Table 1-4 DataCORDER Events -- Continued 1-8.................................................
Table 1-5 Controlled Atmosphere Events Recorded in the DataCORDER 1-8...........................
1-1 62-02575-07
SECTION 1
DESCRIPTION
1.1 HARDW ARE AND SOFTWARE
This manual contains information on the Carrier Transicold DataView Program and its interface with the
DataCORDER. The DataView program is used to retrieve data stored in the DataCORDER.
Data retrieval can be accomplished with one of the following devices:
1. Stand-alone DOS based portable personal computer (PC) with appropriate cable and software
2. Carrier DataReader hand held interrogator (refer to Section 4)
The retrieved data can then be printed from a PC in short or long form reports. From the DataReader, it can be
transferred to a personal computer (PC) for long-term storage on a floppy or hard disk.
The DataView software for a portable computer is supplied on 3.5 inch floppy disks for DOS (refer to Table 1-1). This
software allows data extraction, screen view of the data, hard copy report generation, US DA cold treatment probe
calibration and file management.
Table 1-1 DataView Software
PART NUMBER
DESCRIPTION APPLICATION
12-00413-05 3.5” DS/HD DataView Interrogator S oftware PC/DOS
12-00528-00 3.5”DS/HD DataView (Scroll) Interrogator S oftware PC/DOS
1.2 DataCORDER
The DataCORDER records and stores data. While this manual primarily addresses the interrogation of the
Micro-Link 2 and the Micro-Link 2i DataCORDER (see Figure 1-1 and Figure 1-2), interrogation can also be done on
units with the Micro-Link 1 DataCORDER (see Figure 1-3). Additional information on the DataCORDER may be
found in the unit Operation and S ervice manuals. Please refer to the separately bound manuals listed i n Table 1-2.
Table 1-2. Manual Cross Reference Chart
MANUAL NUMBER
UNIT MODEL NUMBERS COVERED TYPE OF MANUAL
T-259 69NT40-489 Operation and Service
T-267 69NT40-501 Operation and Service
T-268 69NT40-511-1 to 69NT40-511-199 & 69NT40-521 Operation and Service
T-285 69NT40-511-300 & UP Operation and Service
T-289 69NT40-489 with EverFresh Controlled Atmosphere Operation and Service
T-291
69NT40-489--100 and Up with EverFresh Controlled
Atmosphere
Operation and Service
T-292 69NT40-531 Operation and Service
T-294 69NT40-511-200 to 69NT40-511-299 Operation and Service
T-296 69NT40-511-310 Operation and Service
1-262-02575-07
1.2.1 Micro-Link 2 Controller/DataCORDER
The Carrier Transicold Micro-Link 2 Controller (see Figure 1-1) is a custom-designed, microprocessor-based control
system which is fitted with a separate DataCORDER module. The DataCORDER consists of:
1. Microprocessor
2. P rogram memory
3. Data memory
4. Real time clock (RTC)
5. S ix thermistor i nputs (2 Air Temperature and 4 Cargo Temperature)
6. Two voltage inputs
7. Four status LED’s
8. Two communication ports (serial)
9. Power supply (optional battery pack)
CONTROLLER
DataCORDER
Figure 1-1. Micro-Link 2 Contro ller and DataCORDER
1-3 62-02575-07
1.2.2 Micro-Link 2i Controller/DataCORDER
The Micro-Link 2i C ontroller is an integrated Controller and DataCORDER assembly, but is otherwise identical to
the Micro-Link 2 Controller. S croll compressor units are also fitted with a controller Expansion Module located next
to the Controller/DataCORDER.
CONTROLLER/DataCORDER
EXPANSION MODULE
(Scroll Compressor Units Only)
Figure 1-2. Micro-Link 2i Controller/DataCORDER
1-462-02575-07
1.2.3 Micro-Link 1 Controller/DataCORDER
The Carrier Transicold Micro-Link 1 Controller (see Figure 1-3) predates the Micro-Link 2 Controller. Micro-Link 1
units with the DataCORDER option are equipped with a DataCORDER that is an integral part of the Controller.
Interrogation of Micro-Link 1 and Micro-Link 2 Controllers will have some differences.
Figure 1-3. Micro-Link 1 Contro ller
1-5 62-02575-07
1.2.4 DataCORDER Capabilities (Micro-Link 2 and Micro-Link 2i only)
The C arrier DataCORDER is a flexible recording device with the following capabilities:
a. Sensors
Up to six thermistor temperature probes can be connected directly to the DataCORDER.
These probes are referred to as:
1. Supply
2. R eturn
3. USDA 1
4. USDA 2
5. USDA 3
6. Auxiliary Cargo Probe
On separate DataCORDER modules (Micro-Link 2 only) there are also two 0-5vdc inputs available for future
expansion. In addition to these inputs, an additional eight sensors connected to the refrigeration or controlled
atmosphere controllers can be recorded.
1. This list of sensors includes:
2. Humidity Sensor
3. C ontrolled Atmosphere Gas Sensors
4. Temperature Controller Probes (including: supply, return, and defrost temperatures)
5. C ontroller Pressure Sensors
6. Current Sensors
7. Line Voltage Sensor
8. Frequency
NOTE
The s upply and return sensors (SR S and RRS) used by the DataCORDER are not the same supply and return
sensors (STS and RTS) used by the Controller.
b. Log Interval
Micro-Link DataCORDER’s log data on 60 minute intervals from time of trip start. Micro-Link 2/2i DataCORDER
sensors can be recorded at intervals of 15, 30, 60 (default), or 120 minutes. Data is logged on the exact interval, using a
precise real time clock (RTC). All clocks are set to Greenwich Mean Time at the factory and all recording is done on
the exact interval (at 12:00 for example, rather than 12:03).
NOTE
Unless specified by your customer to set t he DataCORDER clocks for another time zone, the clocks should
NOT be adjusted.
c. Sensor Recording Format
Sensors can be recorded in a wide variety of formats. A one byte temperature format can be used for compact data
storage. A two byte format can be used for high resolution over the entire temperature range.
1. One byte format (default): 0.25C(.45F) steps in chilled mode; 0.5C(.9F) steps in frozen mode
2. Two byte format: 0 .010C steps for entire range
d. Sampling Type
1. Averaged (default): shows average of data from every minute over the logging interval .
2. Snapshot: shows snapshot of data at the log interval .
3. USDA: shows snapshot of data at a 60 minute log interval.
1-662-02575-07
1.3 DataCORDER INTERF ACE
The DataCORDER is capable of performing the following functions initiated by the DataView Program
1.3.1 Data Extraction
a. Daily Header Data
Recorded days are presented in the following format:
1. Day 1 date (month, day, year), sensor data, events, ...
2. Day 2 date (month, day, year), sensor data, events, ...
b. Sensor Data
Sensor data will be read based on either standard or generic configuration. P l ease refer to separately bound manuals
coveri ng the Refrigeration Unit for further explanation of standard and generic configurations, see Table 1-2.
1.3.2 Events
Events will be transmitted to t he DataCORDER as specified in Table 1-3, Table 1-4 and Table 1-5. The
DataCORDER compact s the events, disposing of repetitive events to save memory space. All events have a time and
date stamp.
Table 1-3. Temperature Controller Events
Event
When Event Occurs Data Stored Limits
Set Point Change (SP)
Whenever the temperature
set point changes
New set point; method
used to change it
Last 1 per hour, last 6 per
day.
Defrost Start (DS)
Whenever a defrost cycle
is initiated and when the
system is in defrost mode
at midnight
Source of initiation (key-
pad, communications, tim-
er, or active from previous
day)
First 1 per hour, first 10
per day.
Defrost End (DE)
Whenever a defrost cycle
is terminated
Source of termination
(normal, timer, or HTT)
Last 1 per hour, last 10 per
day
Pre-Trip Start (PS)
Whenever Pre-Trip starts
or is active at midnight
Source of initiation (key-
pad, communications, or
active from previous day)
First 1 per hour, first 4 per
day.
Pre - Trip End (PE)
Whenever Pre-Trip com-
pletes.
Pass/Fail data for each test
run since last power up
Last 1 per hour, last 4 per
day.
Dehumidification Start
(DHS)
Whenever dehumidifica-
tion is initiated, or is ac-
tive at midnight
Set point, humidity read-
ing type (active at mid-
night or normal)
First 1 per hour, first 10
per day.
Dehumidification End
(DHE)
Whenever dehumidifica-
tion ends
Set point, humidity read-
ing
Last 1 per hour, last 10 per
day
Humidification Start
(HS)
Whenever humidification
is initiated, or is active at
midnight or “htESt” is run
Set point, humidity read-
ing, method used to cause
it
First 1 per hour, first 10
per day.
Humidification End
(HE)
Whenever humidification
ends
Set point, humidity read-
ing
Last 1 per hour, last 10 per
day
Humidity Set Point
Change
Whenever humidity set
point changes
New set point, method
used to change it
N/A
C
o
n
t
r
o
l
l
e
r
A
l
a
r
m
Case 1: Whenever an
alarm changes state
Case 1: Alarms active dur-
ing this hour
Case 1: 1 per hour which
is a combination of all
alarm events in that hour
Controller
A
larm
Activity (AL)
Case 2: At the end of any
hour where an alarm active
during that hour is inactive
at the end of the hour
Case 2: Currently active
alarms
Case 2: 1 per hour
Controller S /W Upgrade
Any change in the Con-
troller software revision.
New software version Last 1 per day.
Container ID Change
Any time the container ID
is changed
New ID Last 1 per day
1-7 62-02575-07
Table 1-3. Temperature Controller Events -- Continued
Event When Event Occurs Data Sent Limits
Trip Start (TS)
Any time trip start is en-
tered
NA NA
USDA Trip Comment
When entered with
interrogation device
Up to 80 bytes of custom-
er comment data
Last 1 per day
Pre-Trip Data
Any time a Pre-T rip test is
completed and Controller
is configured to send indi-
vidual test data
Pass/Fail for each sub-test,
and appropriate data points
for each test
Unlimited
Economy Mode Start
(ECON_S)
Any time economy mode
is initiated
NA NA
Economy Mode End
(ECON_E)
Any time economy mode
is terminated.
NA NA
ISO Trip Comment
Changed
Whenever entered Data entered by user
Last 1 per hour, last 1 per
day
Bulb Mode Start
(BULB_S)
Any time bulb mode starts
Evaporator fan speed,
DTT opening temperature,
dehumidification set point
NA
Bulb Mode End
(BULB_E)
Any time bulb mode ends NA NA
Controller Configuration
Change
Whenever changed by user Configuration information
Last 1 per hour, last 1 per
day
Operating Mode Change
Whenever unit changes
mode
New operating mode
Last 2 per hour, last 24 per
day
Power Management
Start
(Reciprocating Only)
Whenever power manage-
ment starts
Power management mode
Last 4 per hour, last 24 per
day
Power Management End
(Reciprocating Only)
Whenever power manage-
ment ends
Method used to end power
management
Last 4 per hour, last 24 per
day
Airslide Position
Change
(Reciprocating Only)
Whenever Makeup Vent
Slide Position is changed
Source of change com-
mand
Last 1 per hour, last 6 per
day
Phase Switching
(Scroll Only)
Whenever Phase Sequence
is Checked
Phase switched to correct/
incorrect
Last 6 per hour, last 24 per
day
Table 1- 4 DataCORDER Events
Event
When Event Occurs Data Stored Limits
Case 1: Whenever an
alarm changes state
Case 1: Alarms active
during this hour
Case 1: 1 per hour which
is a combination of all
events in that hour
DataCORDER Alarm Ac-
tivity (DAL)
Case 2: At the end of any
hour where an alarm ac-
tive during that hour is in-
active at the end of the
hour
Case 2: Currently active
alarms
Case 2: 1 per hour
Battery Backup Start
(OFFWB)
Loss of main power with
battery pack present
NA NA
Battery B ackup End
(ONWB)
Restoration of AC power
with battery pack present
NA NA
Power Loss (OFF)
Loss of AC power with no
battery pack present
NA NA
1-862-02575-07
Table 1- 4 DataCORDER Events -- Continued
Event When Event Occurs Data Stored Limits
Power ON (ON)
Restoration of AC power
with no battery pack pres-
ent
NA NA
Data Retrieval
Extraction of data from
the DataCORDER
NA NA
Real Time C lock C hange
User modifies the real
time clock (RTC)
New Date and Time; Old
Date and Time
NA
RTC Battery Replaced
Real Time Clock (RTC)
battery internal to Data-
CORDER is replaced
NA
Last 1 per hour, last 1 per
day
Controller Not
Responding (NWF)
DataCORDER attempted
to communicate with
Controller, but received
no response
NA NA
Controller Responding
(NWR)
DataCORDER was able to
establish communications
with Controller, after a
failed attempt.
NA NA
DataCORDER
Configuration Reset
Whenever the Data-
CORDER detects an in-
valid configuration
NA
First 1 per hour, first 1 per
day
Probe Calibration
When Calibration offset
values are entered
NA
Last 6 per hour, last 24
per day
Table 1- 5 Controlled Atmosphere (CA) Events Recorded in the DataCORDER
Event
When Event Occurs Data Limits
CA Communications
Failure
When communication
with the CA controller is
lost
NA
First 1 per hour, first
24 per day
CA Communications
Recovery
When communication
with the CA controller is
regained
NA
Last 1 per hour, first
24 per day
CA Set Point Change
(CA-SP)
Whenever the O
2
or CO
2
set point is changed
O
2
set point, CO
2
set point
Last 1 per hour, last 6
per day
CA Alarm Reset
Whenever the CA alarm
list is reset
Last 2 per hour, last
10 per day
C
A
A
l
a
r
m
A
c
t
i
v
i
t
y
Case 1: Whenever an
alarm changes state
Case 1: Alarms active during this
hour
Case 1: 1 per hour
which is a combina-
tion of all events in
that hour
C
A
A
larm
A
ctivity
(CA-AL)
Case 2: At the end of any
hour where an alarm ac-
tive during that hour is
inactive at t he end of the
hour.
Case 2: Currently active alarms Case 2: 1 per hour
CA Pre-Trip Start
(CA-PS)
Whenever CA Pre-Trip is
initiated, or is active at
midnight
Source (keypad, communica-
tions, or active at midnight)
First 1 per hour, first
4 per day
CA Pre-Trip End
(CA-PE)
Whenever CA Pre-Trip is
completed
Test data for all CA Pre-Trip tests
run since the last power on.
Last 1 per hour, first 4
per day
1-9 62-02575-07
Table 1-5 Controlled Atmosphere (CA) Events Recorded in the DataCORDER -- Continued
Event When Event Occurs Data Limits
O
2
Air Calibration
Whenever O
2
Air Cal-
ibration is completed
New calibration value; Result
(pass, fail, or low) Source (key-
pad, communications, or timer)
Last 2 per hour, last
10 per day
O
2
Gas C alibration
Whenever O
2
Gas Cal-
ibration is completed
New calibration value; Result
(pass or fail) Source (keypad,
communications, or timer)
Last 2 per hour, last
10 per day
CO
2
Zero Calibration
Whenever CO
2
Zero Cal-
ibration is completed
New calibration value; Result
(pass or fail, no gas) Source (key-
pad, communications, or timer)
Last 2 per hour, last
10 per day
Lockout Start
Whenever the Tempera-
ture Controller initiates a
lockout of CA operation
Type: normal, or active at mid-
night
First 1 per hour
Lockout End
Whenever the Tempera-
ture Controller enables
CA operation.
NA Last 1 per hour.
CA C onfiguration
Change
Any time the CA unit
configuration changes
Configuration variables
Last 2 per hour, last
10 per day
CA Nitrogen Test
Any time a nitrogen test
is completed
N
2
purity values for last l ow, me-
dium, and high flow tests, and
flags to indicate whether low,
medium and high values are in
range
Last 2 per hour, last
10 per day
CA Service Activity
Any time ‘service the fil-
ter ’ hours or compressor
hours expires or is reset,
or the O
2
sensor ’s life is
detected to be low, or the
O
2
sensor is detected re-
placed
Filter hours expired; filter hours
reset; compressor hours expired;
compressor hours reset; O
2
sen-
sor life low; O
2
sensor expired;
filter, compressor, and total run
hours
First 1 per hour
CA Software Upgrade
Any time the CA soft-
ware revision changes
New software version Last 1 per day
CA Controller Replaced
Any time the C A Con-
troller serial number
changes
New serial number Last 1 per day
Door Lock (CA-DL)
Any time the C A door is
locked by the Controller
NA Last 1 per hour
Door Unlock (CA-UL)
Any time the C A door is
unlocked by the Control-
ler
NA Last 1 per hour
Vent Mode S tart
(CA-VS)
Any time CA vent mode
is initiated
NA Last 1 per hour
Vent Mode End
(CA-VE)
Any time CA vent mode
is terminated
NA Last 1 per hour
1-1062-02575-07
1.4 USDA RECORDING
A special type of recording is provided for USDA cold treatment purposes. Cold treatment recording requires that
three remote temperature probes are placed in the car go at various locations. Provision is made to connect these probes
to the DataCORDER via receptacles located at the rear left-hand side of the unit. Four (five, on some units) receptacles
are provided. Four (three-pin) receptacles are for the probes and one (five pin) receptacle is provided for the
Interrogator. All receptacles are sized to accept a Deutsch HD16-5-16S size plug with a tricam coupling locking
device. The DataCORDER inputs are designed to accept a two wire thermistor probe.
A label on the back panel of the unit shows which receptacle is used for each probe. The USDA #1, #2 and #3 probes
(and possibly the optional Car go probe) are installed in these receptacles.
The DataCORDER records up to six probe temperatures (supply, return, USDA #1, #2, #3 and an optional cargo probe
#4), at the logging interval.
The standard DataCORDER report displays the supply and return air temperatures. The cold treatment report displays
USDA #1, #2, #3 and return air temperatures. Cold treatment recording is backed up by a battery so recording can
continue if AC power is lost.
NOTE
There may be an additional (3-pin) receptacle for a car go probe on some units. This should NOT be used for
USDA probes.
1.5 RELATIVE HUMIDITY
When the Relative Humidity Set Point mode is activated or de-activated (i.e., Controller function code Cd33 on
Micro-Link 2/2i), this status is stored in the DataCORDER m emory and reported as an event.
2-1 62-02575-07
SECTION 2
SYSTEM SETUP
2.1 HARDW ARE PLATFORMS SUPPORTED
The DataView S oftware will run on a variety of DOS based machines. We recommend the use of a desktop or laptop
machine with at least 3MB free disk space and a VGA monitor for displaying graphics, for most printing and report
generation functions. Other, less capable computers may be used for the actual data extraction.
2.2 INTERROGATION CABLES
Cable requirements m ay differ between interrogation devices. F or cable connections see Figure 2-1.
9volt
DataReader
Computer Device
DataReader
Micro-Link 2
1
2
3
4
5
6
7
8
9
10
1
1. DataReader
2. Cable, Download
3. Cable, Adapter
4. Cable, Upload
5. Battery, Alkaline -- 9 Volt
6. Software, DataView (DOS)
7. Battery Pack with Charger
8. Cable, Battery
9. Cable Assembly
10. Adapter
NOTE
DataReader Kit i ncludes items 1 through 6, item 2 is not sold separately.
DEUTSCH PLUG
VEAM PLUG
H. P.
PALMTOP
DEUTSCH PLUG
Figure 2-1. Communication Cable Connections
2-262-02575-07
2.3 PRINTER SUPPORT
Formatted reports can be generated on the following printers:
1. EP SON 85 dot matrix or compatible (most dot matrix printers will support this format)
2. HP LaserJet or equivalent (Many laser printers will support this format).
For printers t hat are not compatible with the above printers, select the F ILE printer port option i n printer setup. This
will send the report to an ASCII print file.
2.3.1 PERSONAL COMPUTER PRINTING CABLE CONNECTIONS
After the DataCORDER has been interrogated, the data may be printed from a PC to a parallel or serial printer. Printer
cables will differ depending on the type of printer.
a. Parallel Printer
If you are connecting to a parallel printer, a standard Centronics type printer cable may be used (see F igure 2-2). The
printer cable connects to the printer port on a PC.
1. Portable/Personal
Computer (Parallel Port)
2. Centronics Cable
3. Parallel Printer
1
2
3
Figure 2-2. Parallel Printer Cable Connections
c. Serial Printer
If you are using a Serial Printer, a standard Null-modem type cable may be used (see Figure 2-3). Serial printers with
9-pin serial ports may require a standard 9-socket (female) to 25-pin (male) serial converter.
1. Portable/Personal
Computer (Serial Port)
2. Cable
(Standard Null--Modem type)
3. Parallel Printer
1
2
3
Figure 2-3. Serial Printer Cable Connections
3-1 62-02575-07
SECTION 3
DATAVIEW PROGRAM INSTRUCTIONS
NOTE
The following is a copy of the software program at time of printing. If loading only one program
(12--00413 reciprocating unit interrogation or 12--00528 scroll unit interrogation program) the pro-
gram disc instructions may be followed as written. If loading both programs on the same computer,
different resident directories must be created Where these differences exist, annotation has been add-
ed to the text provided herein.
Refer to the manual Table of Contents for a listing of the following Topics and the material provided
under the topic heading.
TOPIC 1 SYSTEM REQUIREMENTS
This section describes the PC and printer system requirements for the DOS DataView interrogator program.
Desktop Computer
1. MS--DOS compatible computer with an 80186 or higher microprocessor.
2. A hard--disk system ( Or hard--disk emulation with electronic memory).
3. MS--DOS version 3.3 or higher.
4. A minimum of 640KB free System Memory (RAM).
5. A minimum of 3MB free hard--disk space.
6. One 3.5-- inch disk drive. If the system has one diskette drive it will have a drive designator of A. If the system is
configured with two diskette drives the second drive will be designated as B.
7. One Serial Port not dedicated to a FAX--Modem.
8. One of the following ports available for a printing;
Serial port
Parallel port
Network Connection
9. Serial to serial, serial to parallel, or parallel to parallel printer cable.
HP Palmtop Computer
1. MS--DOS compatible computer with an 80186 or higher microprocessor.
2. MS--DOS version 3.3 or higher.
3. A minimum of 640KB free System Memory (RAM).
4. A minimum of 3MB ROM free space available.
5. One RS--232 serial port.
6. Connectivity Pack to transfer/receive files from a desktop computer to/from the HP Palmtop computer.
7. Serial to serial or serial to parallel printer cable.
Pen--Based Computer
1. MS--DOS compatible computer with an 80186 or higher microprocessor.
2. MS--DOS version 3.3 or higher.
3. A minimum of 640KB free System Memory (RAM).
4. A minimum of 3MB ROM free space available.
5. Optional 3.5 floppy disk drive.
6. One RS--232 serial port.
7. Optional parallel port.
8. Serial to serial, serial to parallel, or parallel to parallel printer cable.
3-262-02575-07
Printers Supported
1. EPSON 85 dot matrix or compatible (most dot matrix printers support this format).
2. HP Laser Jet or equivalent (many laser printers support this format).
For printers that are not compatible with the above printers, select the FILE printer port option in printer setup. This
will send the report to an ASCII print file.
TOPIC 2 DESKTOP QUICK START
This section describes the installation procedure for the DOS DataVi ew interrogator program.
Installation From MS--DOS Prompt
This installation procedure will copy the DataView Program to a hard --disk. Approx. 1.5MB of files will be copied.
NOTE
The data view package contains two diskettes. disc part number 12--00413--05 loads software for use with
reciprocating compressor units. Disc 12--00528--00 loads software for use with scroll compressor units. Both
software programs may be loaded on the same computer except different resident directories must be created.
Each DOS DataVi ew program comes on a single 3.5--inch diskette. To begin installation insert the diskette into drive
A:\ or drive B:\. Depending on the drive the diskette is loaded in, at the MS--DOS system prompt type A:\install or
B:\install and press the enter key. The installation program will take the user through the following steps:
a) The startup screen is displayed. Press enter to continue.
b) The product selection screen is displayed. Select which DOS DataView product to install DataView onto: a PC,
Hewlett Packard(HP) Palmtop or penbasedcomputer. Use the up/down arrowkeysto highlight the product, and the
space bar select the product, and press enter to continue.
NOTE
If loading scroll software on the same computer as reciprocating software t he destination directory must be
changed. Suggested change is C:\SCROLLDV. If the destination directory i s not changed, installation of new
reciprocating software will overwrite the scroll software.
c) The destination directory selection screen is displayed. Enter the directory the DataVi ew program will reside in and
press enter. The default directory is “C:\DATAVIEW.” If this directory does not exist on the PC, the installation
program will automatically create the directory.
d) To preserve the previous sensor configuration file, sensors.cnf, the file is copied to sensors.sav.
e) To preserve the previous program configuration file, ml2.cnf, the file is copied to ml2.sav.
f) The custom.cnf, *.DCX, and *.PRN files will not be delete and will remain in the directory.
g) The previous version of the DataView program will be deleted prior to installing the new program.
h) All of the files are downloaded t o the directory defined in step c. As the files are downloaded to the computer, a
progress bar is displayed to indicate the amount of files successfully downloaded. The following files will reside in
the directory defined in step c.
DATAVIEW.EXE
Main Program
RPTVIEW.EXE Report Generator Program
PRNTFILE.EXE Print Report Program
COREMON.EXE Micro-Link 2/2i Monitor Program
CTD2.EXE Micro-Link 1 Program
SELFILE.EXE
DataReader Program -- not included with the HP Palmtop or
Pen--Based computer.
HELP.DAT Help data file
CONTHELP.DAT Controller Monitor Help data file
CGA.BGI Graphics driver
EGAVGA.BGI Graphics driver
ML2.CNF Program configuration file
MODELS2.CNF Model controller configuration file
SENSORS.CNF Sensor configuration file
3-3 62-02575-07
i) Creates the sub directory C:\“directory”\DATA, where “directory” is the directory defined in step c. This is the
working directory where the DCX files are stored.
j) Creates the sub directory C:\“directory”\PRN_FLS, where “directory” is the directory defined in step c. This is the
print file directory where the ASCII Text print files are stored.
k) The user shall be notified when the installation is complete via the Installation Completion Screen and given direc-
tions on how to proceed.
l) To restore t he previous customized version of t he sensor configuration file, execute the following commands at the
MS--DOS prompt:
1. “del sensors.cnf” -- deletes the new sensors.cnf file
2. “ren sensors.sav sensors.cnf” -- restores the old sensors.cnf file
m) To restore t he previous customized version of t he program configuration file, execute the following commands at
the MS--DOS prompt:
1. “del ml2.cnf” -- deletes the new ml2.cnf file
2. “ren ml2.sav ml2.cnf” -- restores the old ml2.cnf file
Additional Steps For The HP Palmtop
This section describes the steps required t o transfer the DataView program from a PC to an HP Palmtop.
a) Prior to transferring the DataView program the user will create the following directories on the HP Palmtop:
Reciprocating Software Scroll Software
1. A:\DATAVIEW 1. A:\SCROLLDV
2. A:\DATAVIEW\DATA 2. A:\SCROLLDV\DATA
3. A:\DATAVIEW\PRN_FLS 3. A:\SCROLLDV\PRN_FLS
b) If a previous version of the DataView program exist on the HP Palmtop, delete all the files in A:\DATAVIEW direc -
tory, “DEL A:\DATAVIEW\*.*.” or “DEL A:\SCROLLDV\*.*.”
c) The HP Palmtop is supplied with the “HP Connectivity Pack Program.” Prior t o transferring the f iles the user will
ensure this program resides on the HP Palmtop and the PC.
d) Using the cables provided with the HP Palmtop, connect the HP Palmtop to the PC.
e) Start the HP Connectivity Software Program on the HP Palmtop and the PC.
f) Copy all the program files located on the PC in the C:\”directory” where ”directory” is the directory defined in the
installation instructions step c, to the A:\DATAVIEW or A:\SCROLLDV directory on the HP Palmtop.
Additional Steps For The Pen--based Computer Without A Floppy Drive
This section describes the steps required to transfer the DataView program from the PC to a Pen--Based computer.
a) Using a serial cable the user shall connect the Pen--Based computer to the PC.
b) The user shall start the Windows Terminal program on the Pen --Based computer and the PC.
c) The user shall copy the installation files located on the PC’s hard drive (i.e., C:\) or the floppy drive (i.e., A:\ or B:\).
The installation files are copied into a temporary directory on t he Pen -- Based computer (i.e., C:\Temp).
d) After the installation files are copied to the Pen --Based computer, t ype C:\Temp\Install to start the installation pro-
gram.
e) Follow the steps defined above to install the program onto the Pen--Based computer.
f) To run the program the CONFIG.SYS file needs to be modified. These changes are required to increase the amount
of system memory used by the DataView program. If these changes are not made, the DataView program will run
out of memory. An out of memory message is displayed, to indicate the problem. For example; when the user is
viewing a file, only a portion of the file will be processed and displayed. The user is notified of the date range that
was processed and can be viewed. The user can continue and view the data or cancel the operation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Carrier Container Refrigeration Unit User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI