Skov DOL 95 Broiler Operating instructions

Type
Operating instructions

Skov DOL 95 Broiler

Skov DOL 95 Broiler is a versatile device designed to optimize broiler production. Here are some of the key features and capabilities of this device:

Production optimization:

  • Monitor key production metrics such as feed conversion, water/feed ratio, feed/animal, mortality, weight, and growth.
  • Adapt feed quantities, water quantities, running time, water times, and light intensity and program based on real-time data.

Alarm settings:

  • Set alarm limits and receive notifications for feed, light, and water-related issues to minimize downtime and ensure optimal conditions for broiler growth.

Skov DOL 95 Broiler

Skov DOL 95 Broiler is a versatile device designed to optimize broiler production. Here are some of the key features and capabilities of this device:

Production optimization:

  • Monitor key production metrics such as feed conversion, water/feed ratio, feed/animal, mortality, weight, and growth.
  • Adapt feed quantities, water quantities, running time, water times, and light intensity and program based on real-time data.

Alarm settings:

  • Set alarm limits and receive notifications for feed, light, and water-related issues to minimize downtime and ensure optimal conditions for broiler growth.
The daily production
Check: Feed conversion Water/feed
Feed/animal Mortality
Weight and growth
There is direct access to these key figures from menu structure.
If you want to see more detailed information, select the
individual function keys.
The feed-, light- and water programmes for the day can be
seen together under:
(DOL 95-2)
(DOL 95-1).
House 1/2 + Curves
Report + Curves
Optimization of the production
Alarm settings
Matrixprinter
Adapt: Feed quantities Water quantities
Running time feed Water times
Mixtures Light intensity
Light program
Alarm limits should be checked and adjusted regularly in
order to get alarm only in case of error conditions and avoid
unneccessary alarms.
Correct new page: When the printer is not running, the paper
edge must be in line with the upper edge of the printer cover.
Important:It is very important to test the alarm system and the connected alarm-related equipment regularly.
Alarms must be tested at least once a week, preferably more frequently.
Password
It is possible to add an password in DOL 95, meaning that
the user has to enter an password in order to change data.
The password is not necessary for scrolling the menus.
If you do not wish to use the password, it can be
disconnected.
The password is a figure between 0 and 9999.
During the installation the password is connected or
disconnected.
The password will be the same, if there is more than one
house.
Start of batch
Press .
DOL 95 is put in the day before the birds
arrive (the minus-day).
1. Check that date and time are set correctly.
2. Check and calibrate the bird weighers.
3. Check that silo status correspond with the content in the
silos. If more types of the same feed component set silo
with start feed to .
4. Calibrate the feed weigher (at least once a year).
Start of batch
Start
5. Start the feeding system to start filling. It is important that
the filling is done on the minus-day in order to register the
feed consumption correctly from the start of the batch.
Set feed programme: Running time feed, feed quantities,
mixture programme.
7. Set water programme. Water time, water guantities.
8. Set light programme: Light periods, light intensity.
9. Check alarm limits and that the alarm system functions as
intended (keep the alarm key pressed for approx. 5 sec. to
activate the test-alarm).
10.Arrange paper in the matrixprinter and switch it on.
Adjust paper to correct new page.
6.
When the birds arrive:
Press
1. Enter number of living birds.
2. Enter parents data: E.g. Ross 38-42 when the parents are
Ross-birds between 38 and 42 weeks.
3. Press and .
Check that is 0
If not, then set to 0.
.
Batch data
Batch days:
End of batch
Press .
DOL 95 is put in right after the birds are
delivered for slaughtering.
1. Put DOL 95 in
2. Print out the batch end report.
3. Do not switch off the power for DOL 95 between two
batches.
End of batch
End of batch.
Feed 1
See feed 2
Dead animals
Partial taking out
Supply of feed
Wheat %, adjustment
Chain feeding, running times
Time before silo empty
Manual broiler weighing
Stop feeding system
Manual start of chain feeding
+ Birds 1/2
+ Birds 1/2 + Taken out
+ Silo + Silo 1/2/3
+ Program
+ Program + Chain
+ Silo + Silo 1/2/3 + Amount
Catching + feeding (from outline screen)
+ Program + Chain
Settings/changes
95 BROILER OPERATING INSTRUCTIONS
Nr.: 605481 EN
Versionnr.: 4.6
House 1 2004.2.23
Day 20 15:33:08
Feed/bird: 69.0 g
Desired: 90.0 -2.0 g
Key fig. Program Silo Main
House 1 Ref.curve feed
Day 1 7 14 21
Feed 12.0 29.0 60.0 96.0 g
Day 28 35 42 49
Feed 133.0 155.0 177.0 193.0 g
W.O.D Back
House 1 Silo Survey
Silo 1 16.358 t
Silo 2 10.345 t
Silo 3 0 t
Silo 4 0 t
Silo 1 Silo 2 More Back
House 1 Silo 1 Delivery
Delivery: 10.234 ton
Type of feed: Feed A Start
Automatic change: Yes
Latest delivery 10/3 11.723 ton
Change Min. Amount Back
House 1 Day: 14 Batch: Now
Feed/bird 104 % 70 g
Feed in mortality 7 kg
Feed A 1505 0 kg
Feed B 245 0 kg
Batch -Day +Day Back
House 1 Day: 20 Period: 2
Feed time 6:45 t:m
Index 80 %
Consumption 600 kg
Target 1125 kg
Water/Feed 203 %
-Period +Period Back
House 1 Day: 20 Batch: -1
Feed/bird 100 % 1.005 kg
Feed in mortality 600 kg
Feed A 23.125 ton
Feed B 1.875 ton
Feed C 0 ton
Feed D 0 ton
Batch -Day +Day Back
House 1 History
Choose historical data
Period 24 hours Total Back
House 1 Silo 1 Change
Gradual changeover 500 kg
Time before changeover 3 min.
Minimum silo contents 0.100 t
Back
House 1 State Feed
Feed A today 1360 0 kg
Feed B today 360 0 kg
Feed C today 0 0 kg
Feed D today 0 0 kg
Water/Feed today 189 %
Back
House 1 Yesterday
Feed/bird 95 g 104 %
Water/feed 184 % 100 %
Running time feed 8:34 t:m 88 %
Feed in mortality 5 kg
State Ref.curve History Back
House 1 Silo 1 Minimum amount
Time until empty 99:59 h:m
Back
House 1 Weight on day
Gain > and < 1.50 1.50 g/g
Integration time 96 hour
Differential time 12 hour
Max. correction +/- 0 0 %
Actual correction 0.0 g
Setup Back
House 1 Weight on day-Setup
Day 7214049
Weigher 2 1 None None
Back
Feed C 0 0 kg
Feed D 0 0 kg
See manual for detail
Feed 2 Start of batch/End of batch
Number of birds Birds weigher
Water Light
Alarm Menu structure picture
Day 1 7 14 21
Start #1 0:00 0:00 0:00 0:00
Stop #1 06:00 03:00 03:00 24:00
Day 28 35 42 49
Start #1 0:00 0:00 0:00 0:00
Stop #1 24:00 24:00 24:00 24:00
Curves Restrict. Next Back
House 1 Chain feeding
Day 0 7 14 21
Number 0 10 10 20
Day 28 35 42 49
Number 21 25 30 45
Back
House 1 Chain
Time for a chain turn 14:00 Min.
Back
House 1 Chain Times
Next start time 15:50
Previous start time 14:35
Running time 0:00 m:s
Number of feedings 19 1
Manual start No
Runs/day Setup Back
House 1 State Program
Mixture A/B/C/D 79.0 21.0 0.0 %
Manual start ---
Manual stop ---
Manual feed/bird 0.0 g
Skip next feeding period NO
Mixture Program Chain Back
Day nr. 1 7 14 21
Start #16 0:00 0:00 0:00 0:00
Stop #16 0:00 0:00 0:00 0:00
Day nr. 28 35 42 49
Start #16 0:00 0:00 0:00 0:00
Stop #16 0:00 0:00 0:00 0:00
Previous Next Back
House 1 Feed programme Day -1
Day -1- 0
Day 1- 6
Day 7-13
0:00 12:00 24:00
Previous Next Back
House 1 Feed program restrictive
Start day restrictive feeding 7
Final day restrictive feeding 40
Actual correction 0.0 kg
Next feeding starts 15:50 h:m
Correction Back
House 1 Feed program restrictive
Time to next feeding 0:17 h:m
Stop feeding-cross auger 15 min.
Min. correction 50 kg
Max. correction +/- 10 10 %
Back
House 1 2004.2.23
Day 20 15:33:08
Execute END OF BATCH
Count down to 0: 9
Batch data Sensors Survey
House 1 2004.2.23
House empty 15:33:08
Execute START OF BATCH
Count down to 0: 9
Batch data Sensors Main
House 1 Batch data
Batch days: 20
Date/time: 2004.2.23 15:33:08
House name: House 1
Back
House 1 Batch data
Is in position END OF BATCH
Date/time: 2004.2.23 15:33:08
House name: House 1
Back
House 1
Is in position END OF BATCH
Back
House 1
Is in position START OF BATCH
Back
House 1 Sensors 2000.6.21
Day 20 15:33:08
1: Temp. 24.1 °C
2: NH3 10.0 ppm
Sensor 1 Sensor 2 Back
Sensor 1 Day 20 Batch: Now
Name: Temp.
Maximum 24.1 °C
Average 22.5 °C
Minimum 20.6 °C
Batch -Day +Day Back
House 1 Mixture program 1/2
Next Back
House 1 Mixture program 2/2
Previous Back
Day ABCD
0 100.0 0.0 0.0 0.0 %
7 95.0 5.0 0.0 0.0 %
14 86.0 14.0 0.0 0.0 %
Day ABCD
28 72.0 28.0 0.0 0.0 %
35 70.0 30.0 0.0 0.0 %
42 70.0 30.0 0.0 0.0 %
21 79.0 21.0 0.0 0.0 %
49 70.0 30.0 0.0 0.0 %
House 1 Monday 2004.2.23
Day 20 15:33:08
Weigt 1: 668 g 96 %
Weigt 2: 790 g 104 %
Weigher 1 Weigher 2 History Survey
House 1 Weigher 1 Hens
Weight 668 g
Growth 51 g
Standard deviation 10.4 %
Reference weight now 683 g
Number of weighings 444
Setup Ref.curve Actual Back
Weigher 1 + 2 Day 14 Batch: Now
Weight 949 g
Indeks 102 %
Growth 97 g
Standard deviation 10.4 %
Number of weighed 416
Batch -Day +Day Back
House 1 Weigher 1 Ref.curve
Day nr. 0 7 14 21
Weigher 42 159 407 750 g
Day nr. 28 35 42 49
Weigher 1150 1571 1979 2361 g
Back
House 1 Weigher 1 Setup
Search limit +/- 30 %
Max. correction +/- 0 %
Correction of weight 100.0 %
Back
Weigher 1 Day 14 Batch: Now
Weight 949 g
Indeks 102 %
Growth 97 g
Standard deviation 10.4 %
Number of weighed 416
Batch -Day +Day Back
House 1 History
Choose historical data
Weigher 1 Weigher 2 Weigher 1+2 Back
House 1 Weigher 1
Last approved weighing 682 g
Weigher signal Actual 234 g
Last stable weigher signal 15 g
Back
House 1 Monday 2004.2.23
Day 7 Dead 15:33:08
Hens: 2.5 % 116 %
Cocks: 2.5 % 98 %
Birds 1 Birds 2 History Main
House 1 Hens
Dead today 27
Dead total 312
Mortality 25 %
Depopulated 0
Ref.curve Back
House 1 Hens
Dead: 0
Dead today: 27
Birds alive: 12187
State Stocked Depopulated Back
House 1 Hens
Stocked birds: 12500
Parents: Ross 35-45
Back
House 1 Hens
Enter Today
Depopulated birds 0 0
Back
House 1 Hens
Day no. 1 7 14 21
Mortality 0.0 1.2 1.7 2.1 %
Day no. 28 35 42 49
Mortality 2.4 2.7 3.0 3.3 %
Back
Hens Day 14 Batch: Now
Mortality 117 2.0 %
Dead 250
Depopulated 0
Stocked 12500
Parents Ross 35-45
-Day +Day Back
Birds 1 + 2 Day 14 Batch: Now
Mortality 117 2.0 %
Dead 500
Depopulated 0
Stocked 25000
-Day +Day Back
House 1 History
Choose historical data
Birds 1 Birds 2 Birds 1+2 Back
House 1 Monday 2004.2.23
Day 20 15:33:08
Light intensity: -2 70 %
Light: On 71 %
State Program Intensity Main
House 1 State
Light switched on at 11:30
Light will switch off at 24:00
Start of next light period 00:00
End of previous light period 10:30
History Back
Day no. 1 7 14 21
Start #1 0:00 0:00 0:00 0:00
Stop #1 10:30 02:00 10:30 24:00
Day no. 28 35 42 49
Start #1 0:00 0:00 0:00 0:00
Stop #1 24:00 24:00 24:00 24:00
Curves Next Back
House 1 Intensity
Day 1 7 14 21
Intensity 100 100 100 100 %
Day 28 35 42 49
Intensity 100 100 100 100 %
Setup Back
House 1 Light program - setup
Light intensity at OFF: 0 %
Dawn: 20 min.
Dusk: 20 min.
Back
Light Day 19 Batch: Now
Light sensor average 74 %
Light hours 23:00
Light switched off at 2
Batch -Day +Day Back
Day no. 1 7 14 21
Start #16 0:00 0:00 0:00 0:00
Stop #16 0:00 0:00 0:00 0:00
Day no. 28 35 42 49
Start #16 0:00 0:00 0:00 0:00
Stop #16 0:00 0:00 0:00 0:00
Previous Back
Stald 1 Light program Day -1
Day 1-0
Day 1-6
Day 7-13
0:00 12:00 24:00
Previous Next Back
Light Day 19 Batch: -1
Light sensor average 77 %
Light hours 23:00
No. of light periods 2
Day -Batch +Batch Back
House 1 Monday 2004.2.23
Day 20 15:33:08
Water/Bird: 127.0 ml
Reference: 167.0 -2.1 ml
State Program History Main
House 1 State
Water/bird: 127.00 ml
Water today: 3175 l
Water total: 53.745 m3
Water: Closed
Ref. Curve Back
Day no. 1 7 14 21
Start #1 0:00 0:00 0:00 0:00
Stop #1 09:00 02:00 02:00 24:00
Day no. 28 35 42 49
Start #1 0:00 0:00 0:00 0:00
Stop #1 24:00 24:00 24:00 24:00
Curves Next Back
House 1 Ref. Curve Water
Day no. 1 7 14 21
Water 23.4 50.6 112.08 161.9 ml
Day no. 28 35 42 49
Water 207.2 259.1 300.2 357.7 ml
Back
Water Day 19 Batch: Now
Daily water/bird 162.0 ml
Index 102 %
Water/feed 187.0 %
Water today 4018 l
Water total 50.570 m3
Batch -Day +Day Back
Day no. 1 7 14 21
Start #16 0:00 0:00 0:00 0:00
Stop #16 0:00 0:00 0:00 0:00
Day no. 28 35 42 49
Start #16 0:00 0:00 0:00 0:00
Stop #16 0:00 0:00 0:00 0:00
Previous Back
House 1 Water program Day -1
Day -1- 0
Day 1- 6
Day 7-13
0:00 12:00 24:00
Previous Next Back
House 1 2004.3.23
Day 20 15:33:08
ALARM: Minimum feed
Start: 2000.6.1 14:44:21
End: ---
Alarm log Limits Acknowled. Survey
House 1 Alarm log 11
Minimum feed
Alarm value 200 kg
Start 2004.2.1 12:22:04
End 2004.2.1 12:34:10
Acknowledged 2004.2.1 12:31:03
-Log +Log Back
House 1 Alarm Limits
Alarms: Retain
Feed Water More Back
House 1 Water Alarm Limits
Not enough water - open
Alarm limit 1.0 l/min.
Alarm output Active
Monitoring time 30 min.
Active from day 7
Next Back
House 1 Feed Alarm limits
Not enough feed at start
Alarm limit 10 kg
Alarm output Active
Monitoring time 15 min.
Active from day 7
Feed weig. Silo Next Back
House 1 2004.3.23
Day 20 15:33:08
No alarms
Alarm log Limits Acknowled. Survey
House 1 2004.3.23
Day 20 15:33:08
Acknowledged alarms
Alarm log Limits Acknowled. Survey
House 1 Sensors Alarm limits
Environment sens. 1 max. alarm
Name Temp.
Alarm limit 38.0 °C
Alarm output Not Active
Monitoring time 1 min.
Light (sensor) Next back
House 1 Catching 15:33:02
Press + or -
To set light intensity
Light: 70 %
Feeding Main
House 1 Catching 15:33:04
Stop feed weigher 2000-2-24 22:00:00
Stop feeding 2000-2-25 01:00:00
Start feeding 2000-2-25 07:00:00
Program Back
House 1 2000.6.21
Day 20 15:33:08
FCR: 1.38
Weight: 725 g
Report Catching
House 1 Day: 20
Feed
Light
Water
0:00 12:00 24:00
-Day +Day Back
House 1 Birds1+2 2000.6.21
Day 20 Batch to now 15:33:08
FCR: 1.38 kg/kg 102 %
Weight: 775 g 106 %
Standard deviation 10.4 %
Mortality 2.5 % 110 %
Back
House 1 Birds1+2 2000.6.21
Day 20 Yesterday 15:33:08
Feed/bird 95 g 104 %
Growth 55 g 100 %
Water/Feed 184 % 100 %
Batch to now Curves Printer Main
House 1 2000.6.21 House 2
Day 20 15:33:08 Day 21
FCR: 1.38 1.40 kg/kg
Weight: 725 790 g
House 1 Catching 1 House 2 Catching 2
House 1 Day: 20
Feed
Light
Water
0:00 12:00 24:00
-Day +Day Back
House 1 Printer Day: 20
Choose print out
Printing completed
Back
  • Page 1 1
  • Page 2 2

Skov DOL 95 Broiler Operating instructions

Type
Operating instructions

Skov DOL 95 Broiler

Skov DOL 95 Broiler is a versatile device designed to optimize broiler production. Here are some of the key features and capabilities of this device:

Production optimization:

  • Monitor key production metrics such as feed conversion, water/feed ratio, feed/animal, mortality, weight, and growth.
  • Adapt feed quantities, water quantities, running time, water times, and light intensity and program based on real-time data.

Alarm settings:

  • Set alarm limits and receive notifications for feed, light, and water-related issues to minimize downtime and ensure optimal conditions for broiler growth.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI