Page 2 of 6 | 20220322
User Manual: Rotomolded Portable Spray Units | English
READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT
Model No.: SP-5N, SP-5NK, SP-5NV
Specicaons:
Hose .............. 30 feet reinforced hose, 3/8 inch inside diameter
(9 meters reinforced hose, 9.5 mm inside diameter)
Tank Capacity.................................................. 5 gallons (20 liters)
Spray Output....................... 2 gallons/minute (7.5 liters/minute)
Spray Output Distance..................... 10 to 12 feet (3 to 4 meters)
Liquid Temperature ........................ 40˚F to 100˚F (4.4˚C to 37˚C)
Dimensions:
Length ....................................... 25 in (635 mm) approximately
Width ........................................ 14 in (356 mm) approximately
Height ....................................... 22 in (559 mm) approximately
Weight, including discharge hose and wand:
(Empty) ................................ 31 lbs (14 kg) approximately
Requirements:
Compressed Air Source Requirements: Air regulator (R25) is
factory set at 50 psi (3.4 bar). Operang range is 40 to 80 PSI (3
to 5 bar) with 2 CFM (56.6 l/min).
Chemical Requirements: Follow all instrucons from chemical
manufacturer and Safety Data Sheet (SDS).
Air Operated Double Diaphragm Pump Models Oered:
P56: Polypropylene body with Santoprene diaphragm
P56V: Polypropylene body with Viton diaphragm
P56K: Polypropylene body with Kalrez diaphragm
Acceptable Products:
Alkaline cleaners, Causc cleaners, Sanizers, and Acids
* D-Limonene may only be used with Kalrez pump
* Chlorine may only be used with Viton or Kalrez pump
DO NOT USE: All hydrocarbons
Read this manual completely and understand the
machine before operang or servicing it.
• Read all instrucons before installing or operang unit.
• Always wear appropriate personal protecve equipment
(PPE) when operang or servicing unit.
• Always follow all chemical safety precauons and
handling instrucons provided by the chemical
manufacturer and Safety Data Sheet (SDS).
• Never point the discharge trigger gun at yourself,
another person, or any object you do not want covered
in chemical.
• Always depressurize unit aer use (as described in the
Aer Use Instrucons), and store unit depressurized.
• Do not exceed an incoming air pressure of 100 psi (7
bar).
• Do not exceed a uid temperature of 100˚F (37˚C).
• Only use clean and dry air. Air must be ltered and free
of moisture or pump life will be diminished. If needed,
install an air dryer before unit.
• Do not use an air lubricator before the unit.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine
components, and hazardous uids in an environmentally safe
way according to local waste disposal regulaons.
Always remember to recycle.
*Specicaons and parts are subject to change without noce.
WARNING