Application Guide ICF Valve Station
5
DKRCI.PA.FT0.A2.22 / 520H5093
© Danfoss A/S (AC-SMC/MWA), 12-2011
Refrigerants
Applicable to all common non ammable
refrigerants including R717, R744 (CO
2
) and non
corrosive gases/liquids dependent on sealing
material compatibility.
For further information please refer to installation
instruction for ICF.
Use of the ICF control solution with ammable
hydrocarbons is not recommended.
For further information please contact the local
Danfoss sales company.
Temperature range
–60/+120°C (–76/+248°F).
If the ICM module is going to be used in liquid
refrigerant with a temperature above +75°C
(+167°F), please contact Danfoss.
The valve train of the
Future since 2005
The ICF valve station is an innovative solution that
provides the full functionality of a conventional
valve station in a single compact unit.
Eliminate project bottleneck:
Conventional valve stations of six or more
individual components and up to twelve welds.
ICF means two welds directly at the job site
Down time during service is reduced to a fraction
compared to conventional valve trains.
The unique design of the ICF ensures a quick
pump down and faster access to valve modules.
The ICF valve is a compact valve train ready for
the jobsite.
This solution provides you with a variety of
benets:
Designed for Industrial Refrigeration
Supplied fully assembled. No need to
disassembly prior to installation under normal
welding procedures
Standard side ports to t service valves,
pressure transmitters, sight glasses.
Applicable to all common non ammable
refrigerants including R744 and R717.
Direct Weld Connections (No leaks through
anges)
Compact design, faster service
Available with dierent connection types
including ANSI and DIN, Socket weld
High capacities low pressure drop
Low weight design
Approvals
ICF valve station
Nominal bore
DN ≤ 25 (1 in.)
DN 32-40 (1¼ - 1½”)
Classied for Fluid group I
Category Article 3, paragraph 3 II
Technical data
Ambient temperature for ICF with ICAD:
–30°C/+50°C (–22°F/122°F)
Surface protection
The external surface is zinc-chromated to provide
corrosion protection.
Additional on-site corrosion protection is
recommended.
Pressure
The ICF is designed for:
Max. working pressure: 52 bar g (754 psig)
Opening dierential pressure
Please refer to the individual function module
data.
CRN