Frico ICF Series Ceiling Fan User manual

Type
User manual

Frico ICF Series Ceiling Fan provides an effective and efficient solution for distributing warm air evenly throughout high-ceilinged spaces, optimizing temperature control and reducing energy consumption. Ideal for warehouses, factories, sports halls, and other large indoor areas, it promotes better air circulation and heating, enhancing comfort levels and reducing cold spots.

Frico ICF Series Ceiling Fan provides an effective and efficient solution for distributing warm air evenly throughout high-ceilinged spaces, optimizing temperature control and reducing energy consumption. Ideal for warehouses, factories, sports halls, and other large indoor areas, it promotes better air circulation and heating, enhancing comfort levels and reducing cold spots.

Code. 5.671.084.210
.... 9
SE
.... 14
DE
.... 13
FR
.... 11
FI .... 12
GB
.... 10
NO
.... 16
PL
.... 15
RU
ICF 20/55
Original instructions
.... 17
DK
ICF 20/55
2
Item
number
Type Height
[mm]
Ø
[mm]
Weight
[kg]
11800 ICF20 545 1422 6,2
11729 ICF55 545 1422 6,2
Dimension
≥ 2,3 m
≥ 2,3 m
A
84 mm
8 kg
= 32 kg
≥ 2,7 m
≥ 2,7 m
ICF 20/55
3
1
2
5
3
4
Installation
6
ICF 20/55
4
7
9
10
IPX5
ø < 6 mm
4
8
ICF 20/55
5
IPX5
13
L
N
52
1
(see ) )
19
15
14
11 12
ICF 20/55
6
18
16 17
L
N
52
1
L
N
52
1
ICF 20/55
7
20
22
21
Maintenance
19
Wiring diagrams ICF20/55
~
1234
L
~~
25
°C
M
~
Black
Blue
Red
N
L
LL
RF
230V~
NN
1
N
5678
N
L
230V~
CAR15
ICF20/55
25
°C
M
~
Black
Blue
Red
1
ICF20/55
25
°C
M
~
Black
Blue
Red
1
ICF20/55
ICF20/55 ICF20/55PE1/2,5
(L)
25
1
25
1
L
N21
NL
230V~
ICF20/55
CFR1R
25
1
5
N
NL
230V~
ICF20/55 ICF20/55
25
1
25
1
RE1,5/3/5
~
N
~
NN
~
Givare golv/
Sensor floor
Givare tak/
Sensor ceiling
Vidarekoppling/
Relay connection
Anslutning för reversering/
Connection for reverse rotation
Switch
ICF 20/55
8
EN ICF 20/55
12
General Instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference.
The guarantee is only valid if the units are used in
the manner intended by the manufacturer and in
accordance with the Frico mounting and operating
instructions.
Areas of use
Roof fans are chiey used to even out the
temperature in premises with high ceilings.
The warm air that collects under the ceiling is
pressed down so that it can heat the occupied
areas underneath. Warm air escape via the
ceiling are thereby reduced. This form of air
mixing also has a quicker heating effect on cold
goods, makes for better drying, and reduces
the risk of cold irradiation.
Enclosure class ICF20: IPX0
Enclosure class ICF55: IPX5
Placement
The fans should be placed symmetrically in the
premises where they can provide optimum
temperature spread. Make sure the fans are
always installed where there is no risk to people
or of contact with objects from the rotating
blades. Nor should they be placed where they
blow air directly on people. Generally fan speed
should be regulated so that they don’t cause
draughts.
Fan installation and electrical connection
See g. 1-19.
Max. surrounding temperature is +40 °C.
The roof fan(s) should only be wired by a
competent electrician and in accordance with
the latest edition of IEE wiring regulations.
Service and maintenance
See g. 20-22.
ICF20/55 is basically maintenance free, but
should be checked on a regular basis.
Important! Check the hanging brackets to avoid the
risk of the fan falling down.
Before cleaning the unit or carrying out
maintenance operations, turn the main switch
off and remove the plug from the power supply.
When several units are controlled with a
common control device the fan speed could
differ from one unit to another. In most cases
these differences will disappear when the fans
have been running for some time (about a
week). Another reason could be that the lower
protective cover is squeezed to tight to the fan,
adjust the coves if necessary.
Safety
This appliance can be used by children aged
from 8 years and above and persons with
reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they
have been given supervision or instruction
concerning use of the appliance in a safe way
and understand the hazards involved. Children
shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
Specications for the power supply must
correspond to the electrical data on data plate A
(g. 2).
Assembly and operating instructions
2023-01-19 HH
Main offi ce
Frico AB Tel: +46 31 336 86 00
Industrivägen 41
SE-433 61 Sävedalen [email protected]
Sweden www.frico.net
For latest updated information and information
about your local contact: www.frico.net
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Frico ICF Series Ceiling Fan User manual

Type
User manual

Frico ICF Series Ceiling Fan provides an effective and efficient solution for distributing warm air evenly throughout high-ceilinged spaces, optimizing temperature control and reducing energy consumption. Ideal for warehouses, factories, sports halls, and other large indoor areas, it promotes better air circulation and heating, enhancing comfort levels and reducing cold spots.

Ask a question and I''ll find the answer in the document