Grid Plus Intelligent
Dimmer Switch
These Grid dimmers comply with both
BS EN 60669-2-1 & BS EN 55015
Please keep this leaflet for future
reference
SAFETY INSTRUCTIONS
• This product must be installed by a competent person
in accordance with the current IEE Wiring regulations
(BS7671) and Building Regulations.
If in any doubt, consult a qualified electrician.
• To prevent electrocution, do not work on any appliance
live. Turn off mains electricity supply before
commencing work.
• An earth terminal is provided on the Grid mounting
frame. This must always be connected to earth.
• To prevent fire hazard do not exceed the related load
specified for the product.
• The minimum box depth required is 40mm.
• Dimmer switches must not be used in bathrooms,
washrooms or any location subject to splashes of water
condensation or dampness.
48366 PL Ed. 1
GENERAL INFORMATION
• The control knob has a push on/push off action.
Rotation of the knob will vary the light setting.
• The terms one-way and two-way switching refer to the
mode of switching required in an installation.
• One-way switching is used in installations that require
just one switch to control a circuit. (i.e. one light that is
either on or off.) See Fig. 1.
• Two-way switching is applied to installations where a
circuit is often controlled by two switches, e.g.
controlling a light circuit from two switches located
some distance apart, one switch at one end of the room
and another switch at the other end.
• MK dimmers have two-way switching, which allows their
use in any application.
• In a two-way installation as shown in Fig. 2, just one
dimmer must be used. A standard 2-way switch must be
used in the other position.
• As long as the rotary control knob is not turned, when
pressed, the dimmer will switch on at the previously set
light level. The light level can then of course be
immediately adjusted by turning the control knob, if
required.
• In a two-way circuit, if the 2-way switch is used to
operate the circuit, the light level will only ever return at
the last used light setting. Light levels can only ever be
adjusted by using the dimmer.
• To avoid damage, do not operate the dimmer outside
its maximum and minimum wattage, or volt/ampere
limits. The limits are shown on the rear of the dimmer,
on packaging and in the Specification section below.
• Please note, it is also necessary to de-rate the dimmers
when used in multiple installations. Please see chart “B”
for the de-rated values.
• The dimmers should not be installed where an ambient
temperature is outside the 0ºC & 40ºC limits.
NOTE:
It is normal for the front of the dimmer to become
quite warm in use, the temperature reached being
dependent upon the lamp load and the ambient
temperature.
• MK dimmers employ the latest technology, using micro-
controlled based circuitry to provide the features
described in the following section.
PRODUCT FEATURES
NOTE;
- For correct operation, it is very important that the
total load MUST NOT be less than the minimum
power/load rating AND MUST NOT be greater than the
maximum power/load rating marked on the dimmer. This
rating is shown in Watts (W) & Volt/Amps (VA) on the back
of each dimmer.
Soft Start When the dimmer is switched on, the brightness
of the lights will be gradually increased over a period of 1
to 3 seconds until a pre-selected level (set by the control
knob, is attained.
This feature alone will help to greatly extend the life
expectancy of filament lamps, by avoiding the initial power
surge.
Overload Protection If any of the dimmers are overloaded,
the output to the lamp(s) will be automatically reduced to
provide protection against damage to the dimmer and to
the installation. An Intelligent Power Monitoring System
(IPMS) is used to provide protection from overload by
reducing power levels to the load(s) in stages according to
the severity of the overload, as follows: - (Note; The first
figures given are the approximate load on the dimmer as a
percentage of its maximum rating.)
Up to 125 Load will receive maximum power
continuously.
› 130 to 200 Output load will be reduced to the minimum
setting after a delay of approximately 20
seconds after switch on.
› 200 Output will be disabled (load will switch off)
almost instantaneously after switch on.
Normal operation will resume after the dimmer is switched
off and turned back on, with the load adjusted to be within
its maximum and minimum ratings.
Compatibility with Low Voltage Lighting Systems
One form of Low Voltage Lighting System comprises a
good quality wire wound step down transformer for Low
Voltage Lighting loaded with suitable Low Voltage
Tungsten Halogen lamps(s). Another form comprises a fully
dimmable Electronic Transformer, specifically designed for
dimming using phase delay, phase-cut-on or leading edge
type of dimmer, loaded with suitable Low Voltage
Tungsten Halogen lamp(s).
The dimmers are designed to work with a large number of
fully dimmable, good quality, Wire Wound as well as
Electronic Low Voltage Lighting Transformers, which are
recommended for use with phase delay, or leading edge
type dimmers. DO NOT
use transformers that are only
suitable for use with phase cut, phase cut-off, or trailing
edge type dimmers.
So as not to compromise system safety, MK recommend
that transformers have built in thermal protection and have
over-current protection on both primary and secondary
circuits. The LV system must comply with the EMC directive
and carry the CE marking. The total transformer load on
the dimmer (obtained by adding together the load rating
of each transformer) must be within the minimum and
maximum load rating W/VA of the dimmer.
In addition, transformers MUST be loaded correctly and
they must provide correct loading to the dimmer, within its
specified minimum and maximum Power/Load ratings.
For optimum performance of the dimmer, load each
transformer with lamp(s) so that the total load on each
transformer is between 75 - 100% of its rated load. (e.g.
load a transformer rated at 25 to 105W/VA with lamps, so
that their total wattage adds up to 80 to 105 watts.Note:
Some transformers for low voltage lighting have input
circuits which, when used with phase delay types of
dimmer, result in very high peak power pulses in the
dimmer. To avoid overloading and possible malfunctioning
of the dimmer, do not connect more than the maximum
number of transformers specified below, to any one
dimmer.
Up to 300W/240VA dimmers - Max. 4 transformers.
Over 300W/240VA dimmers - Max. 5 transformers.
Compatibility with Mains Voltage Halogen Lamps
The soft start feature incorporated in this range of dimmers
makes them ideally suited to drive mains voltage halogen
lamps, which have inherently high inrush currents at switch
on. By using a soft start with this type of load(s), not only is
the dimmer protected against premature failure but the
lamp(s) load also benefits from prolonged life due to
limitation of the life shortening high inrush currents at
switch on.
Failure to comply with the pre-requisites given above could
compromise System Safety.
None of the MK Grid dimmers are suitable for use with
fluorescent lighting, which includes energy saving lamps.
SPECIFICATION
Nominal mains supply voltage .............. 230 volts a.c.
Max. acceptable mains fluctuation ........ 216 to 253V a.c.
Mains frequency ..................................... 50Hz ± 3Hz
Ambient temperature range .................. 0°C to 40°C
The Grid dimmers can be used with the following: -
• Fused GLS Tungsten Filament lamps to BS EN 60064,
rated at 230/240 volts only.
• Mains rated Halogen lamps
• Wire wound Low Voltage transformer(s) of good quality,
either laminated or toroidal.
• Fully dimmable Electronic Transformer(s) suitable for
mains input voltage range specified above, used in
conjunction with Low Voltage Halogen lamp(s).
NOTE: Transformers must be suitable for dimming; using
the phase delay, not phase cut type of dimmers.
Under no circumstances should the minimum/ maximum
ratings given in table “A” be exceeded.
1. On front plates mounting multiple dimmers, the minimum
/ maximum W and VA ratings given are for each dimmer.
2. The minimum load of the transformer should not be less
than the Min. Power/Load Rating of the dimmer, even if
the transformer has a lower Min. power/Load rating (e.g.
20W or VA).
3. If the transformer is loaded with more than one lamp to
achieve the minimum load in accordance with the Min.
Power/Load Rating, then on failure of one or more of the
lamps, the total load may fall below the Min. Power/Load
Rating of the dimmer, which could result in the system not
functioning correctly.
1
module 40 220 40 180 3
2
module 60 400 60 320 5
Size of
dimmer
Power/Load
rating With
mains Tungsten
GLS lamps
Power/Load rating
With mains Tungsten
Halogen Lamps and
LV Transformers
Max. No.
Transfor-
mers per
dimmer
Min.
Wattage
Max.
Wattage
Min.
W or VA
Max.
W or VA
Table A