MK K1402S Installation guide

Category
Dimmers
Type
Installation guide

MK K1402S is a 1kW Trailing Edge Dimmer Module designed to be used with K1401M and K1402M master modules. It can be used for various lighting applications, including:

  • Resistive/Incandescent lighting
  • Mains Halogen lighting
  • Low Voltage Halogen lighting with Electronic transformers

The device has a maximum load rating of 1000W for resistive/incandescent lighting and 900VA for mains halogen and low voltage halogen lighting with electronic transformers. It features trailing edge control inputs from the master dimmer or another trailing edge slave, allowing multiple dimmers to be connected and controlled together.

MK K1402S is a 1kW Trailing Edge Dimmer Module designed to be used with K1401M and K1402M master modules. It can be used for various lighting applications, including:

  • Resistive/Incandescent lighting
  • Mains Halogen lighting
  • Low Voltage Halogen lighting with Electronic transformers

The device has a maximum load rating of 1000W for resistive/incandescent lighting and 900VA for mains halogen and low voltage halogen lighting with electronic transformers. It features trailing edge control inputs from the master dimmer or another trailing edge slave, allowing multiple dimmers to be connected and controlled together.

Page 1
K1402S
®
®
1kW Trailing Edge Dimmer Module - Slave
Installation & Operating Instructions
SAFETY:
Danger 220-240 Volts: Always disconnect the electricity supply
before commencing any work on the installation of device or
changing lamps or bulbs.
The device should be installed by a competent person or a qualified
electrician in accordance with the device’s installation instructions and the
appropriate current national wiring regulations.
It is essential that all connections are made as instructed, that cables are
not stressed and that terminals are fully tightened.
The mains supply to this product must be protected by an appropriate
fuse or MCB.
TECHNICAL INFORMATION:
Reduction of the dimmer power:
If this product is used in an ambient temperature exceeding 40°C, the
maximum allowable load will need to be reduced according to the table
below. This will prevent the internal thermal protection in the product from
activating and switching the load off.
Vorsicht! Erhöhte
Strahlung
Vorsicht! Kontamination Vorsicht! Kontamination Vorsicht, Gefahr durch
Abquetschen
Vorsicht, Gefahr durch
Abschneiden
Vorsicht, Gefahr durch
Abstürzen
Vorsicht, Gefahr durch
ätzende Stoffe
Vorsicht, Gefahr durch
elektrischen Strom
Vorsicht, Gefahr durch
elektrischen Strom
Vorsicht, Gefahr durch
elektromagnetische
Strahlung
Vorsicht, Gefahr durch
explosionsgefährliche
Stoffe
Vorsicht, Gefahr durch
feuergefährliche Stoffe
Vorsicht, Gefahr durch
giftige Stoffe
Vorsicht, Gefahr durch
heiße Oberfläche
Vorsicht, Gefahr durch
Laserstrahlung
Vorsicht, Gefahr durch
Radioaktivität
Vorsicht, Gefahr durch
Rutschen
Vorsicht, Gefahr durch
Stolpern
Vorsicht, Gefahr durch
Verwickeln
Vorsicht, Warnung vor
einer Gefahrstelle
Vorsichtig verschieben!
- veraltet -
Während der
Schweißarbeiten,
Arbeitsstelle beobachten
Wandbrände nicht von
oben löschen
Wandbrände von unten
nach oben löschen
Wandhydrant Wandhydrant (2.
Vorschlag)
Wandhydrant, mit Angabe
des Anschlusses
Wareneingang -
Freigegeben
Wareneingang - Gesperrt Wärmeabzugseinrichtung
-10
0
10
20
30
40
50
60
70
80
90
100
0
200
400
600
800
1000
Ambient temperature in °C
Maximum Rated Load (W)
GENERAL:
Connection of the Slave Dimmer to a Master:
Slave
Connection
K1401M
Leading edge master
dimmer
K1402M
Trailing edge master
dimmer
Input A
Connect to slave
output A2
Connect to slave
output A1
Input B
Connect to slave
output B2
Connect to slave
output B1
Connection of the Slave Dimmer to another Slave:
Slave
Connection
K1402S
Trailing edge slave dimmer
Input A connect to slave output A
Input B connect to slave output B
Output A connect to slave input A
Output B connect to slave input B
Slave Units must only be connected to other slaves of the same type.
Hohlwand-Installationsklei
nverteiler
Hörgeschädigtensysmbol Hubschrauber-Landeplatz
, Warnung vor
Rotorblättern
Hunde tragen während
Rolltreppenbenutzung
Hupen Hupen geboten
-2.Vorschlag-
Hygienischen Atemschutz
benutzen
Im Brandfall keinen
Aufzug benutzen!
Im Brandfall werden sie
alarmiert! Wenn Sie einen
Brand entdecken, Brand
Impulslichtbogenschweiß
en
Imputz-Installationsdose Inert-Gas-Einrichrung
Infektiöse Stoffe
[Unterklasse 6.2] [IMO]
Information für die
Feuerwehr
Information,
Informationsstelle
Informieren Sie sich bitte
über die Lage der
Treppen, Notausgänge.
Inline-Skating nicht
gestattet
Installationskanal
Instrumente Instrumentiertische,
-flächen
Internationaler
Landanschluss
Ionisierende
Strahlungsenergie
Isolierende
Schutzhandschuhe für
Arbeiten unter
Kalibriert
Kaltlicht; Elektromedizin,
Beleuchtung über
Lichtleiter
Karzinogenität
(Gefahrenkategorien 1A,
1B und 2)
Keimzell-Mutagenität
(Gefahrenkategorien 1A,
1B und 2)
Kein Handhaken
verwenden
Kein Trinkwasser Kein Trinkwasser (ISO)
Note: The outputs of the K1402M and K1402S trailing edge
dimmers may be connected in parallel to drive a single load
greater than 1kW/900VA.
L N
IN
Out
IN
Out
Slave
A AB B
K1402S
1kW Trailing Edge Dimmer - Slave
For use with K1401M and K1402M master modules
R, C
®
®
60-1000VA 50-900VA
EN 60669-2-1
Made in Germany
50061980-001
ε
220-240V~ / 50Hz
220V~ / 60 Hz
F
LoadL N
1 2
A B A B
1
IN
A / B
Trailing edge control inputs from Master dimmer or
another trailing edge slave.
2
OUT
A / B
Output connections to another K1402S trailing edge
slave dimmer.
General:
Operating voltage:
220-240V~ / 50Hz
220V~ / 60Hz
Ambient operating temperature: -5 to +40°C
Standards: EN 60669-2-1
Dimensions, (w x h): 108 x 55mm, 6 DIN modules
Technical Specification:
Control wiring lengths:
Maximum of 100m in total
Use 0.5-0.75mm mains rated cable
Load compatibility:
Resistive and Capacitive/Electronic
transformer lighting loads only
Minimum load: 60W / 50VA
Load rating:
Resistive / Incandescent 1000W
Mains Halogen 1000W
Low Voltage Halogen with
Electronic transformers
900VA
Page 2
INSTALLATION:
The dimmer module is designed for mounting into distribution and
consumer units containing 35 mm DIN rail according to EN50022.
Please observe the following points during installation:
All master and slave dimmers must be connected to the same supply
phase.
The mains supply to the dimmer(s) must be protected by a suitable fuse
or MCB rated no greater than 16A
Do not exceed maximum control line length of 100m and do not run
slave control lines parallel to mains and network cables.
Always observe the transformers recommended loading guidelines.
Load transformers at or close to their full rated capacity. Do not connect
a small load to a larger transformers, (e.g. a 35W lamp on a 600VA
transformer)
Ensure that slaves are wired to the correct control terminals and that
the polarity is observed
Vorsicht! Erhöhte
Strahlung
Vorsicht! Kontamination Vorsicht! Kontamination Vorsicht, Gefahr durch
Abquetschen
Vorsicht, Gefahr durch
Abschneiden
Vorsicht, Gefahr durch
Abstürzen
Vorsicht, Gefahr durch
ätzende Stoffe
Vorsicht, Gefahr durch
elektrischen Strom
Vorsicht, Gefahr durch
elektrischen Strom
Vorsicht, Gefahr durch
elektromagnetische
Strahlung
Vorsicht, Gefahr durch
explosionsgefährliche
Stoffe
Vorsicht, Gefahr durch
feuergefährliche Stoffe
Vorsicht, Gefahr durch
giftige Stoffe
Vorsicht, Gefahr durch
heiße Oberfläche
Vorsicht, Gefahr durch
Laserstrahlung
Vorsicht, Gefahr durch
Radioaktivität
Vorsicht, Gefahr durch
Rutschen
Vorsicht, Gefahr durch
Stolpern
Vorsicht, Gefahr durch
Verwickeln
Vorsicht, Warnung vor
einer Gefahrstelle
Vorsichtig verschieben!
- veraltet -
Während der
Schweißarbeiten,
Arbeitsstelle beobachten
Wandbrände nicht von
oben löschen
Wandbrände von unten
nach oben löschen
Wandhydrant Wandhydrant (2.
Vorschlag)
Wandhydrant, mit Angabe
des Anschlusses
Wareneingang -
Freigegeben
Wareneingang - Gesperrt Wärmeabzugseinrichtung
Important:
Inductive loads (i.e. conventional wire-wound transformers, etc.)
must not be connected to the trailing edge dimmers.
OPERATION:
The slave dimmers have no independent operation or functionality. They
will automatically follow the operating mode and load state of the master.
TROUBLESHOOTING:
If your product does not work properly please check the
following items,
Mains supply MCB and voltage.
Cable connections and wiring.
Ensure that connected lamps are operational and have not blown.
Ambient temperature and ensure dimmer is not overloaded.
Note: Normal voltage and frequency fluctuations on the mains supply can manifest
as flicker on the lamps and does not represent a fault with the product.
Contact Details
If you require advice on the installation or use of these products please
contact the appropriate technical service helpline:
UK and Ireland
+44 (0)1268 563720
UAE (+971) 4 807320
Singapore 1800 461 6333
Malaysia 1800 88 4507
Hong Kong 2953 6379
India (+91) 44 2616 1234
OTHER INFORMATION:
Disposal:
At the end of their useful life the packaging and product should be
disposed of via a suitable recycling centre. Do not dispose of with your
normal household waste. Do not burn.
Guarantee:
MK Electric undertakes to replace or repair at its discretion goods should
they become defective within 2 years solely as a result of faulty materials
and workmanship. Understandably if the product has not been installed,
operated or maintained in accordance with the instructions, has not been
used appropriately or if any attempt has been made to rectify, dismantle or
alter the product in any way the guarantee will be invalidated.
The guarantee states MK Electric’s entire liability. It does not extend to
cover consequential loss or damage or installation costs arising from the
defective product. This guarantee does not restrict, infringe or in any way
affect the normal statutory or other rights of the consumer.
50061985-001_A
®
®
MK Electric
The Arnold Centre, Paycocke Rd, ,
Basildon Essex SS14 3EA UK
Telephone +44 (0)1268 563000
Fax +44 (0)1268 563404
MK Electric (Middle East)
Honeywell ME, FZE, P.O. Box 18530,
Jebel All, Dubai U.A.E.
Telephone (+971) 4 807 3200
Fax (+971) 4 881 5733
MK Electric (Singapore) Pte Ltd
8 Pandan Crescent, UE Tech Park,
#01-06 (LL4), Singapore 128464
Telephone (+65) 6461 6333
Fax (+65) 6461 6336 / 6338
MK Electric (Malaysia) Sdn Bhd
(Co. No. 39068-A). Komplek Perusahaan LTAT,
Jalan Pengapit 15/19, 40000 Shah Alam,
Selangor Darul Ehsan, Malaysia
Telephone (+603) 5519 4507
Fax (+603) 5510 8867
MK Electric (China) Ltd
25/F, Honeywell Tower, Olympia Plaza,
255 King’s Road, North Point, Hong Kong
Telephone (+852) 2331 9133
(+852) 2834 1988
Fax (+852) 2151 9465
Honeywell ED&S India Ltd
Crescendo, 995 B, Second Avenue, ,,
Annanagar, Chennai, India PIN: 60040
Telephone (+91) 44 2616 1234
(+91) 44 6632 6789
Fax (+91) 44 2616 1235
www.electrical.honeywell.com
Novar ED&S Ltd, (A Honeywell Company)
Arlington Business Park, Bracknell,
Berkshire, RG12 1EB, UK
Copyright Novar ED&S Ltd 2011. All rights reserved.
L N
F
F
L N
IN
Out
IN
Out
Slave
A AB B
K1402S
1kW Trailing Edge Dimmer - Slave
For use with K1401M and K1402M master modules
R, C
®
®
60-1000VA 50-900VA
EN 60669-2-1
Made in Germany
50061980-001
ε
220-240V~ / 50Hz
220V~ / 60 Hz
F
L N
IN
Out
IN
Out
Slave
A AB B
K1402S
1kW Trailing Edge Dimmer - Slave
For use with K1401M and K1402M master modules
R, C
®
®
60-1000VA 50-900VA
EN 60669-2-1
Made in Germany
50061980-001
ε
220-240V~ / 50Hz
220V~ / 60 Hz
F
220-240V~ / 50Hz
220V~ / 60Hz
To control connection (A,B)
of the master dimmer
A B
A B
  • Page 1 1
  • Page 2 2

MK K1402S Installation guide

Category
Dimmers
Type
Installation guide

MK K1402S is a 1kW Trailing Edge Dimmer Module designed to be used with K1401M and K1402M master modules. It can be used for various lighting applications, including:

  • Resistive/Incandescent lighting
  • Mains Halogen lighting
  • Low Voltage Halogen lighting with Electronic transformers

The device has a maximum load rating of 1000W for resistive/incandescent lighting and 900VA for mains halogen and low voltage halogen lighting with electronic transformers. It features trailing edge control inputs from the master dimmer or another trailing edge slave, allowing multiple dimmers to be connected and controlled together.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI