Pelco Sarix® Professional II IJP Series Micro Indoor Dome Quick start guide

Type
Quick start guide

Pelco Sarix® Professional II IJP Series Micro Indoor Dome is a high-quality indoor surveillance camera designed for professional use. With its compact 2” form factor, it's ideal for discreet monitoring in a wide range of indoor environments, such as offices, retail stores, and warehouses. The IJP Series Micro Indoor Dome features a sharp image sensor that delivers crystal-clear video footage, even in low-light conditions. It also offers a wide field of view, ensuring comprehensive coverage of the monitored area.

Pelco Sarix® Professional II IJP Series Micro Indoor Dome is a high-quality indoor surveillance camera designed for professional use. With its compact 2” form factor, it's ideal for discreet monitoring in a wide range of indoor environments, such as offices, retail stores, and warehouses. The IJP Series Micro Indoor Dome features a sharp image sensor that delivers crystal-clear video footage, even in low-light conditions. It also offers a wide field of view, ensuring comprehensive coverage of the monitored area.

C2291M-A-EN (10/30)
Sarix
®
Professional IMP
Series 3.75” Indoor Dome
Quick Start Guide
IMP121-1IS
IMP221-1IS
IMP321-1IS
IMP521-1IS
C2291M-A-EN (10/30)
Sarix
®
Professional IJP
Series 2” Micro Indoor Dome
Quick Start Guide
IJP121-1IS
IJP221-1IS
3
Contents
Contents ....................................................................................................................................................................................... 3
Important Notices Statement ........................................................................................................................................................ 5
Warranty Statement ..................................................................................................................................................................... 5
Models Instructions ...................................................................................................................................................................... 6
IMP Series 3.75” Indoor Dome ....................................................................................................................................... 6
IJP Series 2” Micro Indoor Dome ................................................................................................................................... 6
Description ................................................................................................................................................................................... 7
IMP Series 3.75” Indoor Dome ....................................................................................................................................... 7
IJP Series 2” Micro Indoor Dome ................................................................................................................................... 7
Package Contents ........................................................................................................................................................................ 7
IMP Series 3.75” Indoor Dome ....................................................................................................................................... 7
IJP Series 2” Micro Indoor Dome ................................................................................................................................... 7
Optional Accessories .................................................................................................................................................................... 7
IMP Series 3.75” Indoor Dome ....................................................................................................................................... 7
IJP Series 2” Micro Indoor Dome ................................................................................................................................... 7
Installation - IMP Series 3.75” Indoor Dome ................................................................................................................................. 8
In-Ceiling Flush Mount ................................................................................................................................................... 8
Wall Surface Mount ...................................................................................................................................................... 10
Pendant Mount ............................................................................................................................................................. 11
Position the Camera .................................................................................................................................................... 13
Adjusting the Focus ..................................................................................................................................................... 13
Installation - IJP Series 2” Micro Indoor Dome ........................................................................................................................... 14
Wall/Ceiling Surface Mount .......................................................................................................................................... 14
Surface Mount with IMPEBAP ..................................................................................................................................... 15
Wall Mount with IMPPMB-1I ........................................................................................................................................ 16
Positioning & Adjusting the Field of View ..................................................................................................................... 17
Pelco Troubleshooting Contact Information ............................................................................................................................... 18
Note for Dimension Drawings ..................................................................................................................................................... 18
4
5
Important Notices Statement
For information about Pelco’s product-specific important notices and thereto related information, refer to www.pelco.com/legal.
REGULATORY NOTICES
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority
to operate this equipment under Federal Communications Commission’s rules.
CAN ICES-3(A)/NMB-3(A)
Korean Class A EMC
Warranty Statement
For information about Pelco’s product warranty and thereto related information, refer to www.pelco.com/warranty.
UL SAFETY NOTICES
The product is intended to be supplied by a Listed Power Unit marked "L.P.S." (or "Limited Power Source") and rated output
12Vdc/0.70A or 24Vac, 0.56A minimum or 48Vdc, 0.15A minimum.
The product shall be installed by a qualified service person and the installation shall conform to all local codes.
6
Models Instructions
IMP SERIES 3.75” INDOOR DOME
The physical appearances and installation methods for the models indicated within the list below are, by and large, the same.
Therefore, please use this quick guide where we use the example from IMP521-1IS as a reference to apply to all the varied
models.
Model
Description
IMP121-1IS
1MP Indoor Dome with Vari-focal lens
IMP221-1IS
2MP Indoor Dome with Vari-focal lens
IMP321-1IS
3MP Indoor Dome with Vari-focal lens
IMP521-1IS
5MP Indoor Dome with Vari-focal lens
IJP SERIES 2” MICRO INDOOR DOME
The physical appearances and installation methods for the IJP 2” Indoor models indicated within the list below are, by and
large, the same. Therefore, please regard use manual where we use the example from IJP221-1IS as a reference to apply to
all the models.
Model
Description
IJP121-1IS
1MP 2” Micro Indoor Dome
IJP221-1IS
2MP 2” Micro Indoor Dome
7
Description
IMP SERIES 3.75” INDOOR DOME
The Sarix® Professional Series IP 3.75” Indoor Dome is ideal for indoor applications. Before installing it, please verify your
model and read this guide carefully.
IJP SERIES 2” MICRO INDOOR DOME
The Sarix® Professional Series IP 2” Micro Indoor Dome is ideal for indoor applications. Before installing it, please verify your
model and read this guide carefully
Package Contents
IMP SERIES 3.75” INDOOR DOME
3.75” Indoor Dome camera * 1
Plastic Anchor * 4
Flat Head Screw (Tapping Type) * 4
Security Torx Wrench * 1
Mounting Template * 2
Printed quick installation guide * 1
Resources sheet * 1
Terminal Block * 1
Conduit Hole Plug * 1
Important Safety Instruction * 1
Anti-Seize lubricant (only necessary with pendant version, not supplied)
IJP SERIES 2” MICRO INDOOR DOME
Fixed Indoor Dome Camera * 1
Plastic Anchor * 2
Flat Head Screw (Tapping Type) * 2
Mounting Template * 1
Printed quick installation guide * 1
Resources sheet * 1
Important Safety Instruction * 1
Optional Accessories
IMP SERIES 3.75” INDOOR DOME
IMPICM-1ER: In-ceiling wall mount, for use with the environmental models
IMPPM-1ER: Pendant adapter, for use with the environmental models
IJP SERIES 2” MICRO INDOOR DOME
IMPEBAP: 4S electrical box adapter
IMPPMB-1I: Wall mount bracket for micro indoor dome models
8
Installation - IMP Series 3.75” Indoor Dome
Sarix® Professional Series IP 3.75” Indoor Dome can be installed using the following methods.
In-Ceiling Flush Mount (requires in-ceiling mounting kit)
Wall Surface Mount
Pendant mount (requires pendant mounting kit)
IN-CEILING FLUSH MOUNT
Install the environmental vandal dome camera to an in-ceiling area as shown in the following procedure.
1. Utilize torx wrench to loosen the screws on lens base and top cover in order to disassemble the 3 parts of camera individually.
2. Connect the required cables (Ethernet and Alarm/Audio Input/Output threads) with the corresponding ports on rear side.
The digital IO ports are described below:
Alarm Out: Via Au/I and GND ports, connect to external device like microphone that receives sound for camera.
Audio Out: Via Au/O and GND ports, connect to device like speaker to be triggered through alarm output signals.
Alarm Out: Via COM and AO ports, connect to external device to be triggered through alarm output signals.
Alarm In: Via GND and AI ports, connect to external device that can trigger alarm input signals.
1
2
3
4
9
3. Attach the mounting template onto an in-ceiling surface followed by drilling a hole based on the template indication.
4. Embed the in-ceiling mount bracket into the hole that was drilled based on the mounting template.
5. Use a cross screw driver to turn the 2 bracket screws clockwise to extend the locking arms and tighten them securely to
compress the locking arms so that the bracket can be fixed within the in-ceiling area firmly.
6. Based on your needs, use the bottom conduit hole or side conduit hole on lower case for cable entry and connect the cables.
NOTE: Please properly lock the conduit hole plug on the unused hole. For example, lock the side conduit hole with the
plug while using the bottom conduit hole for cable entry and vice versa.
7. Fix the lower case onto the in-ceiling bracket by fastening the 4 screws followed by aligning the identifying red dots of
lower case and lens base to properly assemble them together with securing the 3 lens base screws.
8. After adjusting focus position to the satisfied field of view, mount the top cover on the lens base, both of which have a red
dot respectively also for aligning identification and tighten the 3 top cover screws firmly.
9. Attach the 2 spring hooks flanked the protective cover to the in-ceiling bracket for mounting completion.
NOTE: It is strongly recommended that you first ensure the mounting area is stable enough to withstand the in-ceiling
bracket and locking arms clamping on the ground of safety concern.
5
6
Protective Cover
Spring Hook * 2
10
WALL SURFACE MOUNT
Install the environmental vandal dome camera to a wall surface as shown in the following procedure.
1. Based on your needs, use the bottom or side conduit hole on the lower case for cable entry and connect the required
cables first. Then mount the lower case on a surface by securing screws (supplied) into the inserted plastic anchors tightly.
2. Align the lower case and the lens base, both of which have a red dot on the top side respectively for aligning
identification. Use the red dots to properly align them and then securely fasten the 3 screws of the lens base to the
bottom case with torx key (supplied).
3. Adjust the focusing position by rotating, panning and tilting the camera lens base. When rotating the camera lens, do not
rotate it over the stop point.
4. Fit the inner liner over the camera lens base until it snaps into the place.
5. Mount the top cover on the lens base, both of which similarly have a red dot for aligning identification. Be aware that the
red dot of the top cover is within the interior instead of on the top side.
6. Use the torx wrench (supplied) to tighten the 3 top cover screws to complete mounting.
NOTE: Please properly lock the conduit hole plug on the unused hole. For example, lock the side conduit hole with the
plug while using the bottom conduit hole for cable entry and vice versa.
T2
T2
T1
T1
T1
T1
11
PENDANT MOUNT
Install the 3.75” indoor dome camera to pendant pipe as shown in the following procedure.
NOTE: Mounts and conduits must be sealed to prevent condensation in the camera
The Pendant Installation involves mounting the camera to the wall with IMPPM-1ER Sarix Environmental Pendant Mount
for Indoor/Environmental Vandal Domes. The camera must be installed in the back box with a 3/4 rain-tight compression
gland (#1) and a lock nut (#2) as shown below. The compression gland and lock nut are not provided.
1. Rotate the adaptor ring, which can connect with 1 1/2pole later, clockwise to the pendant mount back box securely as shown
below. The diagram in the right side is the back box mounted with the adaptor ring.
NOTE: Anti-seize compound should be applied on environmental pendant. Not doing so might prevent the unit from
being separated in the future. Waterproof tape can also be used to help prevent water ingress damage.
Adaptor Ring
Rain-tight Compression Gland
Lock Nut
12
2. Attach the lens base to the pendant mount back box after wires connection and securely fasten the 3 screws of the lens
base by the torx wrench (supplied). Finally, assemble the top cover with the lens base, which is already attached to the
back box, followed by fastening the 3 screws of top cover to complete the installation.
13
POSITION THE CAMERA
The camera has three axes for adjusting field of view on different applications. While screening live view on your monitor,
adjust the position by using the procedures below simultaneously for desired focusing position.
Pan Adjustment (A)
Rotate the lens base until you are satisfied with the field of view. Note that the side conduit hole of lower case is the point
where the camera lens shouldn’t be rotated over.
Horizontal Rotation (B)
Rotate 3D assembly in the lens base, but do not turn assembly more than 355° as this may have the internal cables
twisted, disconnected, or broken.
Tilt Adjustment (C)
Lift to open the inner liner, and tilt the camera lens to your desired angle. Restore the inner liner back to its default
position after adjustment.
NOTE: Limitation for three axes position: Pan range: ±177°, Rotate range: ±177°, Tilt range: 35°~ 90°
ADJUSTING THE FOCUS
1. View the camera image using the browser (refer to the user manual).
2. Use the settings in the Web interface (refer to the user manual) to adjust the zoom and focus of the lens to the desired
field of view.
3. Also the focus can be adjusted by moving the zoom slider and using the Focus options in the live webpage.
NOTE: Focus adjustment is done exclusively with the Web UI.
A
B
C
14
Installation - IJP Series 2” Micro Indoor Dome
You can install the Sarix® Professional Series Micro Indoor Dome using the following method.
Wall/Ceiling Surface Mount
Surface Mount with IMPEBAP
Wall Mount with IMPPMB-1I
WALL/CEILING SURFACE MOUNT
Install the 2” indoor Micro dome camera to a surface (wall/ceiling) as shown in the following procedure.
1. Pull the top cover downward to take apart it from the camera body after pressing and holding the 2 latch buttons at 2 sides.
2. Connect the required network cable and the optional digital IO cables if necessary. Thread the cables through either
bottom or side conduit hole depending on different mounting applications. The digital IO ports are described below:
Alarm Out: Via OUT and COM ports, connect to external device to be triggered through alarm output signals.
Alarm In: Via “GND” and “IN” ports, connect to external device that can trigger alarm input signals.
Audio Out: Via “GND” and OUT ports, connect to device like speaker to be triggered through alarm output signals.
Audio In: Via GND” and “INports, connect to external device like microphone that receives sound for camera.
3. Drill 2 hole patterns on applied surface in accordance with the indications on the mounting template (2-Ø4.5 Holes)
followed by hammering the 2 plastic anchors into the drilled holes. Also, drill another hole for cable threading as the
indication for bottom conduit installation (Ignore drilling cable hole if applying side conduit method).
4. Attach the camera to the surface properly and fasten the 2 screws into the plugged plastic anchors securely to fix the
camera on the location.
5. Install the top cover upward to assemble the camera completely. The camera is thus stably fixed on the surface.
1
2
3
4
5
15
SURFACE MOUNT WITH IMPEBAP
You can mount the camera to a surface with IMPEBAP, a Sarix 4S electrical box adaptor mount for
Micro Indoor Dome. Refer to the figures below for surface installation with IMPEBAP.
1. Fix the adaptor plate to the surface embedded with 4S electrical box with 2 screws. Note the hole pattern with “4”
indicators that represent the exact holes for 4S installation on the adaptor for proper mounting.
2. Pass all the cable thread from camera body into the adaptor plate and surface followed by wiring them if necessary.
Fasten the camera body onto the adaptor plate with 2 screws. Note the hole pattern with “D” indicators that represent
the exact holes for Micro Indoor Dome installation on the adaptor for proper mounting.
3. Properly attach the dome cover until click to the camera body that was fixed with the adaptor plate already.
4. The Micro Indoor Dome is eventually properly mounted on the surface with IMPEBAP.
1
2
3
4
16
WALL MOUNT WITH IMPPMB-1I
Wall mount with IMPPMB-1I requires both the L-shape bracket and the adaptor plate from IMPEBAP. Refer to the figures
below for detailed process for Wall Mount with IMPPMB-1I.
1. Fasten the L-shape bracket onto the desired wall with 4 screws.
2. Further fix the adaptor plate from IMPEBAP onto the L-shape bracket with 2 screws. Note the hole pattern with
“L” indicators that represent the exact holes for L-shape bracket assembly on the adaptor for proper installation.
3. Pass all the cable thread from camera body into the adaptor plate and L-shape bracket followed by wiring them if
necessary. Fasten the camera body onto the adaptor plate with 2 screws. Note the hole pattern with “D
indicators that represent the exact holes for Micro Indoor Dome installation on the adaptor for proper mounting.
4. Properly attach the dome cover until click to the camera body that was fixed with the adaptor plate already.
5. The Micro Indoor Dome is eventually properly mounted on the wall with IMPPMB-1I.
1
3
2
4
5
17
POSITIONING & ADJUSTING THE FIELD OF VIEW
The camera has three axes for adjusting field of view on different applications. While screening live view on your monitor,
adjust the position using the procedures below simultaneously for desired focusing position.
Pan Adjustment (A)
Rotate the lens base until satisfied with the field of view. Note that the bottom conduit hole of camera body is the point
where the camera lens shouldn’t be rotated over.
Horizontal Rotation (B)
Rotate 3D assembly in the lens, but do not turn assembly more than the limit as this may have the internal cables
twisted, disconnected, or broken.
Tilt Adjustment (C)
Adjust the camera lens tiltedly within the certain range (35° - 90°) to your desired field of view.
A. Pan = ±177°
B. Rotate = ±177°
C. Tilt = 35° 90°
A
B
C
18
Pelco Troubleshooting Contact Information
If the instructions provided fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or
+1-559-292-1981 (international) for assistance. Be sure to have the serial number available when calling.
Do not try to repair the unit yourself. Leave maintenance and repairs to qualified technical personnel only.
Note for Dimension Drawings
NOTE: VALUES IN PARENTHESES ARE INCHES; ALL OTHERS ARE CENTIMETERS.
3.75” INDOOR DOME
2” MICRO INDOOR
DOME
19
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

Pelco Sarix® Professional II IJP Series Micro Indoor Dome Quick start guide

Type
Quick start guide

Pelco Sarix® Professional II IJP Series Micro Indoor Dome is a high-quality indoor surveillance camera designed for professional use. With its compact 2” form factor, it's ideal for discreet monitoring in a wide range of indoor environments, such as offices, retail stores, and warehouses. The IJP Series Micro Indoor Dome features a sharp image sensor that delivers crystal-clear video footage, even in low-light conditions. It also offers a wide field of view, ensuring comprehensive coverage of the monitored area.

Ask a question and I''ll find the answer in the document