Legrand Unity Professional Services User guide

Type
User guide
2012 by Legrand All Rights Reserved
Unity Installation
Professional Services Guide
Page 2
2012 by Legrand All Rights Reserved
Table of Contents
Installation & Wiring Requirements
Graphical User Interfaces……………………………………………………………………………………………Page 4
Selective Call Intercom……………………………………………………………………………………………....Page 5
Cameras……………………………………………………………………………………………………………….Page 6
lyriQ Multi Room Audio………………………………………………………………………………………………Page 7
Local Area Network…………………………………………………………………………………………………..Page 9
Installation & Setup
How to terminate Cat5e………………………………………………………………………………………………Page 10
Updating Firmware……………………………………………………………………………………………………Page 12
Reserving Unity IP addresses……………………………………………………………………………………….Page 13
Accessing Web Setup………………………………………………………………………………………………..Page 14
Configure Date/Time Settings……………………………………………………………………………………….Page 15
Changing Device Names…………………………………………………………………………………………….Page 17
Associating Cameras and Selective Call Intercom Devices……………………………………………………..Page19
Associating lyriQ Multi Room Audio Zones and Selective Call Intercom Devices…………………………….Page 21
IP Camera Configuration…………………………………………………………………………………………….Page 23
Port Forwarding Remote Mobile Control Applications……………………………………………………………Page 25
Operation & Setup
User Interfaces
How to change background colors……………………………………………………………………….Page 26
How to connect a mobile device………………………………………………………………………….Page 27
Intercom
How to Answer the Door…………………………………………………………………………………..Page 28
How to Make a Call………………………………………………………………………………………..Page 29
How to record and send messages………………………………………………………………………Page 30
How to play a message……………………………………………………………………………………Page 31
How to change a door chime……………………………………………………………………………..Page 32
How to record a custom door chime……………………………………………………………………..Page 33
How to disable mute and monitor modes………………………………………………………………..Page 36
How to setup door messaging…………………………………………………………………………….Page 37
Page 3
2012 by Legrand All Rights Reserved
Table of Contents
Operation & Setup Continued
Music
How to operate music by room…………………………………………………………………………….Page 40
How to operate music by scene…………………………………………………………………………...Page 41
How to create music scenes……………………………………………………………………………….Page 42
How to operate music by source…………………………………………………………………………..Page 44
Player
How to select shared music………………………………………………………………………………..Page 45
How to catalog shared music………………………………………………………………………………Page 46
How to manually add a share………………………………………………………………………………Page 47
Windows 7 Settings..………………………………………………………………………………Page 49
Windows Vista Settings……………………………………………………………………………Page 54
Windows XP Settings…………………………………...…………………………………………Page 57
Apple OS X Settings…………………………………………………………………………….…Page 59
How to select internet radio stations………………………………………………………………………Page 62
How to setup a Tunein.com account……………………………………………………………………...Page 63
How to share music from the SD card (models & showroom only)…………………………………….Page 65
Cameras
How to monitor cameras from an LCD or TVDI…………………………………………………………..Page 68
How to monitor cameras over IP using a LAN connection….…………………………………………..Page 69
How to monitor cameras over IP using a WAN connection….………………………………………….Page 71
Weather
How to setup your location……………………………………………………………………………….Page 73
Events
How to create an event……………………………………………………………………………………..Page 74
Lighting
How to add RF Lighting Control……………………………………………………………………………Page 76
How to operate lighting zones & collections………………………………………………………………Page 79
How to operate lighting scenes…………………………………………………………………………….Page 80
How to create lighting scenes………………………………………………………………………………Page 81
Frequently Asked Questions and Trouble Shooting……………………………………………………………....Page 82
Internet Service Provider Connection……………………………………………………………………………….Page 87
Page 4
2012 by Legrand All Rights Reserved
Installation & Wiring Requirements
1. GRAPHICAL USER INTERFACES
HA5000-xx LCD Console
Box/Ring Requirement: 3-Gang (mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (purple recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: None
HA5009-xx LCD Console with lyriQ
Box/Ring Requirement: 3-Gang (mud ring recommended)
Cable Requirement: (2) CAT5e 328-foot max. (1 purple & 1 green recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: L&R Speaker/L&R Line Level Phoenix Connectors
HA5010-xx LCD Console with High-Performance lyriQ
Box/Ring Requirement: 3-Gang (mud ring recommended)
Cable Requirement: (2) CAT5e 328-foot max. ( 1 purple & 1 green recommended) & (1) 16/4
Termination Point: Structured Wiring Enclosure
Connection Points: L&R Speaker Out, Sub Out, HA1000 Power Input Phoenix Connectors
HA5201-xx TV Display Interface (TVDI)
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (purple recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: Composite Video, L&R Analog Audio output to TV, 3.5mm IR target input
HA5000-xx/HA5201-xx Installation Diagram
HA5009-xx/HA5010-xx Installation Diagram
Page 5
2012 by Legrand All Rights Reserved
Installation & Wiring Requirements
2. SELECTIVE CALL INTERCOM
IC5000-xx Selective Call Intercom Room Unit
Box/Ring Requirement: 2-Gang (Legrand AC1009-02 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (White recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: None
IC5002-xx Selective Call Intercom Door Unit
Box/Ring Requirement: 2-Gang (Legrand AC1009-02 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (White recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: Sensor Input/Door Chime Output (22/2 recommended)
IC5003-XX Selective Call Intercom Video Door Unit
Box/Ring Requirement: 2-Gang (Legrand AC1009-02 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (White recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: Sensor Input/Door Chime Output (22/2 recommended)
IC5004-XX Selective Call Intercom Patio Unit
Box/Ring Requirement: 2-Gang (Legrand AC1009-02 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (White recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: None
Selective Call Intercom Installation Diagram
Page 6
2012 by Legrand All Rights Reserved
Installation & Wiring Requirements
3. CAMERAS
CM5002 Ball Camera
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (yellow recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: Microphone
CM1029 IR Camera
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (yellow recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: Microphone
F2299/2284 Bullet Camera
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (yellow recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: Microphone
F2286 Decorator Mount Mini Camera
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (yellow recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: None
CM5002 ONLY Installation Diagram
F Series/Third Party Camera Installation Diagram
Page 7
2012 by Legrand All Rights Reserved
Installation & Wiring Requirements
4. LYRIQ MULTIROOM AUDIO
AU1004 Single Source Main Input
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (green recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: L&R Analog Audio Input, (3) IR Output, (1) IR Input
AU5015 Charge & Play Main Input
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (green recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: L&R Analog Audio Input, USB Charging Output
AU1015 airQast Main Input
Box/Ring Requirement: N/A
Cable Requirement: Custom Supplied
Termination Point: Structured Wiring Enclosure
Connection Points: Mini USB & 3.5mm phone jack for custom cable.
AU1011 Triple Source Main Input
Box/Ring Requirement: 1-Gang (Legrand AC1009-02 mud ring recommended)
Cable Requirement: (2) CAT5e 328-foot max. (green recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: (3) L&R Analog Audio Input, (3) IR Output, (1) IR Input
AU5008 Local Source Input (LSI)
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (2) CAT5e 328-foot max. (green recommended)
Termination Point: Structured Wiring Enclosure/KVC (in series)
Connection Points: L&R Analog Audio Input, RJ-45 CAT5e In/Out (backside)
AU5009 Standard Keypad Volume Control (KVC)
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (green recommended)
Termination Point: Structured Wiring Enclosure
Connection Points: L&R Speaker/L&R Line Level (backside)
Page 8
2012 by Legrand All Rights Reserved
Installation & Wiring Requirements
AU5010 High Performance Keypad Volume Control (KVC)
Box/Ring Requirement: 1-Gang (Legrand AC1009-11 mud ring recommended)
Cable Requirement: (1) CAT5e 328-foot max. (green recommended) & (1) 16/4
Termination Point: Structured Wiring Enclosure
Connection Points: L&R Speaker Output/Sub Out/AU1000 Input (backside)
Interchangeable
main source inputs
Single Source Wiring Diagram
Multi Source Wiring Diagram
Page 9
2012 by Legrand All Rights Reserved
Installation & Wiring Requirements
5. LOCAL AREA NETWORK (LAN)
DA1004 10/100 Router/Switch
Cable Requirement: CAT5e 328-foot max. (blue recommended)
Connection Points: (4) LAN / (1) WAN
DA1008 10/100/1000 Giga-bit Switch
Cable Requirement: CAT5e 328-foot max. (blue recommended)
Connection Points: (8) LAN
DA1101 Wireless Access Point
Box/Ring Requirement: 3-Gang In-Ceiling / 1-Gang I-Wall
Cable Requirement: (1) CAT5e 328-foot max. (blue recommended)
Termination Point: Structured Wiring Enclosure (POE Module)
Connection Points: (1) DATA IN / (1) DATA/
Basic Network Installation Diagram
Page 10
2012 by Legrand All Rights Reserved
Handling Cat5e
Page 11
2012 by Legrand All Rights Reserved
Handling Cat5e
Page 12
2012 by Legrand All Rights Reserved
Updating Firmware
1. INTRODUCTION
Updating the firmware of Unity system requires a Local Area Network connection with a shared
internet connection. Always check for firmware updates prior to configuring a system for the first
time to make sure you are running the latest firmware version.
2. HOW TO STEP-BY-STEP
STEP 1: Using the left or right arrow button on the LCD or TVDI remote,
navigate the applications icon menu until the “Setup” icon is in the middle
of the display and press the “talk/select” button.
STEP 2: Use the down arrow button to select “System” and press
“talk/select” to enter the “Setup / System” menu
STEP 3: Press hot-key #2 on an LCD or the Green button on the
TVDI remote to “Update” the system firm ware version.
STEP 4: A pop up will appear. Press hot-key #3 on an LCD or the
YELLOW button on the TVDI remote to select “Yes” to start the update.
3. SPECIAL NOTES
A pop up will appear followed by the
“UPDATING” screen to communicate the
status of the update. This can take up to 20
minutes to complete.
Once the update is complete the system will
reboot itself.
Page 13
2012 by Legrand All Rights Reserved
Reserved DHCP
1. INTRODUCTION
To ensure the Unity module always has the same IP address it is recommended that you set up
the local router’s reserved DHCP settings.
2. HOW TO STEP-BY-STEP
STEP 1: Open a web-browser on a PC or Mac connected to the network
and type in the IP address of the router. Legrand routers default
192.168.40.254
STEP 2: in the pop up, enter the username and password for
the router settings menu. Legrand routers default
admin/admin.
STEP 3: Open the LAN/DHCP Client List menu..
STEP 4: Click the checkbox under “Static” for the IP
addresses or MAC addresses of the Unity Module. All
Legrand devices have a MAC address starting with
00:26:EC:xx:xx.
STEP 5: Click “OK” to save the changes and restart the
router.
Page 14
2012 by Legrand All Rights Reserved
Accessing Web Setup
1. INTRODUCTION
The most efficient way to configure and setup Unity is to use the web-setup utility served directly
from the Unity Module. Most settings can be adjusted in the web-setup.
2. HOW TO STEP-BY-STEP
STEP 1: Using the left or right arrow button on the LCD or TVDI remote,
navigate the applications icon menu until the “Setup” icon is in the middle
of the display and press the “talk/select” button.
STEP 2: Use the down arrow button to select the “Network Info” option and
press the “talk/select” button.
STEP 3: Open your PC web browser and enter
the Web Setup IP address into the address bar of
the browser.
3. SPECIAL NOTES
The PC must be connected to the Local Area Network
supporting Unity.
The only settings you cannot adjust from the web-
setup utility are display settings:
o LCD - Background Position Window Size,
Brightness, Color, Contrast and Background
Bubbles
o TVDI - Background, Position Window Size and
Background Bubbles
Page 15
2012 by Legrand All Rights Reserved
Configuring Date/Time Settings
1. INTRODUCTION
There are two ways the date/time info can be setup. The easiest way is to make sure Unity is
connected to the local area network with a shared internet connection allowing the system to auto-
update from the web.
2. HOW TO STEP-BY-STEP
STEP 1: Using the left or right arrow button on the LCD or TVDI remote,
navigate the applications icon menu until the “Setup” icon is in the middle
of the display and press the “talk/select” button.
STEP 2: Use the down arrow button to select “System” and press
“talk/select” to enter the “Setup / System” menu
STEP 3: Press “talk/select” to enter the “Setup/System/Auto Clock
Set” menu.
STEP 4: By default, “Enable Auto Clock Set” is set to “Yes”. To turn it off
for manual set up, use the right-arrow button to select “No”.
STEP 5: Using the down arrow button, highlight the “Select Time
Zone” field and use the right-arrow button to select the correct time
zone.
Page 16
2012 by Legrand All Rights Reserved
Configuring Date/Time Settings
STEP 5: Using the down-arrow button, highlight the “Daylight Saving Time”
field and use the right-arrow button to select “No” if you are installing Unity
in an area that does not observe daylight saving time.
STEP 6: If necessary, you can adjust the
“DST Begin” and “DST End” Settings.
3. SPECIAL NOTES
If you disabled the auto-clock set feature or if the
local area network does not have a shared internet
connection, you can manually set the “Time” and
“Date” by selecting each menu separately and use
the arrow keys to set each field to the correct
values.
Page 17
2012 by Legrand All Rights Reserved
Changing Device Names
1. INTRODUCTION
Each device will be assigned a default name based on what type of device it is.
Changing a device name from the default is recommended to personalize the system to the
project and identify where the device is located such as in the Kitchen, Family Room, or Bedroom
1.
Further personalization is recommended once the home is occupied as Bedroom 1 might be
Johnny’s Room. It will be easier for the end user to operate the system properly if they are able to
select a device in Johnny’s Room.
2. HOW TO STEP-BY-STEP
STEP 1: Using the left or right arrow button on the LCD or TVDI remote,
navigate the applications icon menu until the “Setup” icon is in the middle
of the display and press the “talk/select” button.
STEP 2: Use the down arrow button to select the device type you want to
change and press “talk/select” to enter the device specific sub menu. For
example, select “Intercom” to change the name of an intercom device.
STEP 3: Use the down arrow to select the specific device options you
want to change and press “talk/select” to enter the device specific sub
menu. For example, “Room Options” to change the name of a
Selective Call Intercom room unit.
STEP 4: Use the down arrow to select the specific device you want to
rename. For example, “ROOM 1”.
Page 18
2012 by Legrand All Rights Reserved
Changing Device Names
STEP 5: With the name field highlighted, press the left or right arrow
buttons to select from over 100 preprogrammed names. For example,
“Bedroom 1”
STEP 6: To custom enter a name, like “Johnny’s Rm” press the “Custom”
button and use the pop up keyboard navigating with the left, right, up, down,
hot keys across the bottom and the “talk/select” buttons to spell the custom
name. Once finished, press the “Accept” button to save the name.
STEP 7: Once you have entered the correct name press “Done” to
save the name and return to the previous sub menu.
3. SPECIAL NOTES
Press the “Home” button anytime to return to the main applications icon menu.
Page 19
2012 by Legrand All Rights Reserved
Associating Cameras & SCI devices
1. INTRODUCTION
Unity can display a camera image on the LCD when an intercom device is selected, allowing the
individual operating the LCD to see the selected room while making a call.
2. HOW TO STEP-BY-STEP
STEP 1: Using the left or right arrow button on the LCD or TVDI remote,
navigate the applications icon menu until the “Setup” icon is in the middle
of the display and press the “talk/select” button.
STEP 2: Use the down arrow button to select “Intercom” and press
“talk/select” to enter the “Setup/Intercom” menu..
STEP 3: Use the down arrow to select the specific intercom device
type you want to configure and press “talk/select”. For example,
“Room Options” to associate a camera in a room with a Selective Call
Intercom room unit in the same room.
STEP 4: Use the right-arrow to select the specific device you want to
associate a camera with. For example, “Johnny’s Room”
STEP 5: Use the down-arrow button to highlight the “Camera” field.
STEP 6: Use the right-arrow button to select the
name of the camera you want to associate. For
example “Johnny’s Room”
Page 20
2012 by Legrand All Rights Reserved
Associating Cameras & SCI devices
SPECIAL NOTES
Video door units are automatically associated with their camera. This step does not
need to be completed for those units.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87

Legrand Unity Professional Services User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI