England's Stove Works Gas Heater 55SHPAH User manual

Category
Stoves
Type
User manual

This manual is also suitable for

PELLETAUXILIARYHEATER



INSTALLATION&OPERATIONMANUAL
25‐PAH/55‐SHPAH/55‐TRPAH







 
REV.12/2011



CAUTION
Pleasereadthisentiremanualbeforeinstallationanduseofthispelletfuel‐
burningappliance.Keepchildren,furniture,fixturesandallcombustiblesaway
fromanyheatingappliance.
SAFETYNOTICE
Failuretofollowtheseinstructionscanresultinpropertydamage,bodilyinjury
orevendeath.Foryoursafetyandprotection,followtheinstallation
instructionsoutlinedinthismanual.Contactyourlocalbuildingorfireofficials
aboutrestrictionsandinstallationinspectionrequirements(includingpermits)
inyourarea.
SAVETHESEINSTRUCTIO NS
ManufacturedBy:
England’sStoveWorks,Inc.
POBox206
Monroe
,
VA24574
Page | 2


WARNING:
ο‚· Useofoutsidecombustionairismandatorywiththisunit.
ο‚· Donotoperatewiththehopperopen;lidmustbeshut
andtightlylatchedduringoperation.
Retainforyourfiles

ModelNumber________________________
DateofPurchase_______________________
DateofManufacture____________________
SerialNumber_________________________

*Thisinformationcanbefoundonthesafetytagattachedtotheundersideofthe
hopperlid.Havethisinformationonhandifyouphone thefactoryoryourdealer
regardingthisproduct.
IMPORTANT:IFYOUHAVEAPROBLEMWITHTHISUNIT,DO
NOTRETURNITTOTHEDEALER.CONTACTTECHNICAL
SUPPORT@1‐800‐245‐6489
Note:England’sStoveWorksdoesnotrecommendusinga
pelletstoveasyouronlysourceofheat.
MobileHomeUse:
Thisfreestandingpelletunitisapprovedformobilehomeor
doublewideinstallationwiththeoutsidecombustionairhook‐
up.Seetheξ€ƒβ€œInstallation”sectionofthismanualfordetails
pertainingtomobilehomeinstallations.Mobilehome
installationmustbeinaccordancewiththeManufactured
HomeandSafet
y
Standard
(
HUD
)
,CFR3280,Part24.
Page | 3
TABLEOFCONTENTS

Introduction
ο‚· Introduction.................................4
Specifications
ο‚· HeatingSpecifications..................5
ο‚· Dimensions...................................5
ο‚· EPACompliance...........................5
Installation
ο‚· InstallationOverview...................6
ο‚· ClearancestoCombustibles.........7
ο‚· VentingIntroduction....................8
ο‚· VentingGuidelines.......................8
ο‚· AdditionalVentingInformation...9
ο‚· ApprovedVentingMethods
o ThroughtheWall...........10
o ThroughtheCeiling........11
o ExistingChimney............12
ο‚· MobileHomeInstallation..........13
ο‚· OutsideAirHook‐Up..................14
ο‚· FloorProtection.........................15
DailyOperation
ο‚· GettingStarted...........................16
ο‚· LightingaFire........................16‐17
ο‚· ControlBoardSettings...............18
ο‚· ErrorCodes................................19
ο‚· PowerFailure.............................20
ο‚· ThermostatInstallation..............21
ο‚· ThermostatOperation...............22
ο‚· OptionalAccessories..................22
Maintenance
ο‚· Daily
o ImportantNotes.............23
o DailyAshRemoval.....23‐24
o CleaningtheBurnpot.....24
ο‚· Monthly
o ImportantNotes.............25
o ExhaustChamber......25‐26
o VentingPipe...................26
ο‚· Yearly
o ImportantNotes.............27
o ExhaustBlower..............28
o ConvectionBlower.........29
o HopperFines..................29
o CheckingGaskets...........29
TroubleshootingGuide
ο‚· Troubleshooting....................30‐31
ReplacingComponents
ο‚· AugerMotor...............................32
ο‚· ConvectionBlower.....................33
ο‚· CombustionBlower...................33
ο‚· VacuumSensor..........................34
ο‚· Igniter.........................................34
ο‚· Gaskets.......................................35
ο‚· Finish..........................................35
ο‚· Glass...........................................36
ο‚· ControlBoard.............................37
ο‚·
WiringDiagram..........................38
IllustratedPartsDetail

ο‚· ExplodedPartsDiagram.............39
ο‚· PartsList.....................................40
Warranty
ο‚· WarrantyDetails...................41‐42
ο‚· WarrantyReg.Form..............43‐44

Page | 4
INTRODUCTION

ThankyouforpurchasingthisfineproductfromEngland’sStoveWorks!

England’sStoveWorkswasstarted,andisstillownedby,afamilythat
believesstronglyinaξ€ƒβ€œDoItYourself”spirit;that’sonereasonyou
foundthisproductatyourfavoriteξ€ƒβ€œDoItYourself”store.

Weintentionallydesign
andbuildourstovessothatanyhomeowner
canmaintaintheirunitwithbasictools,andwe’realwaysmorethan
happytoshowyouhowtodothejobaseasilyandasinexpensivelyas
possible.However,whileremainingsimple,ourstovesaredesignedto
performextremelyefficiently,helpingdelivermore
heatfromlessfuel.

PleaselookatourvastHelpsectiononourwebsiteandcallour
TechnicalSupportDepartmentat(800)245‐6489ifyouneedanyhelp
withyourunit.Wearenearlyalwaysabletoξ€ƒβ€œwalkyouthrough”any
installationissues,repairs,problemsorotherquestionsthat
youmay
have.

Wishingyouyearsofefficient,qualityandξ€ƒβ€œcomfy”heating,

EVERYONEATENGLAND’SSTOVEWORKS


PleaseNote
:Whileinformationobtainedfromourwebsiteand
throughourTechnicalSupportlineisalwaysfreeofcharge,therewill
beaservicechargeincurredwithanyξ€ƒβ€œon‐site”repairsormaintenance
thatwemayarrange.



Thismanualencompassesallversionsofthe25‐PAH,includingthe55‐SHPAH,55‐
SPAHLand55‐TRPAH.However,forsimplicityofdescription,thestovewillbe
referredtobythegeneric25‐PAHdesignation.
Page | 5
SPECIFICATIONS

HeatingSpecifications

ο‚· HeatOutputRange**............................................11,000BTU/hr–25,000BTU/hr
ο‚· ApproximatePelletBurnRate**...............................................1.6lb/hr–4.0lb/hr
ο‚· MaximumBurnTime**..............................................................................72hours
ο‚· ApproximateSquareFootageHeated***.....................................800‐2000sq.ft.
ο‚· HopperCapacity.....................................................................................120pounds

Dimensions


















EPAandSafetyComplianceSpecifications

ο‚· EPACompliance...........................................................................................Certified
ο‚· ParticulateEmissions..........................................................................1.55grams/hr
ο‚· Efficiency*...........................................................................................................78%
ο‚· TestedTo........................... ASTME1509,ULC/ORD‐C1482‐M1990&ULCS627‐00
*‐Thisunitwasnottestedforefficiency;theefficiencyshownisadefaultvaluenormallyattainedbysimilar,certifiedpelletburningappliances.
**‐Heatoutput,burnrateandmaximumburntimeareheavilydependentonthetypeofpelletsburnedinthestove;assuch,thesenumbers
mayvary.
***
‐Themaximumheatingcapacityofthisunitcanvarygreatlybasedonclimate,constructionstyle,insulationandamyriadofotherfactors.
UsethisinformationinconjunctionwithaBTUlosscalculationforyourhometodetermineifthisunitwillbesufficientforyourneeds.
12.125in.
5.5in.
24.25in.
24.25in.
31.3125in.
8.4375in.
7.00in.
Page | 6
INSTALLATION

InstallationOverview

Whenchoosingalocationforyournewstove,thereareamultitudeof
factorsthatshouldbetakenintoaccountbeforebeginningtheinstallation.

1. TrafficPatterns–Tohelppreventaccidents,thestoveshouldbeplaced
inalocationwhereitisoutofthewayofnormaltravel
throughthe
home.

2. HeatFlow–Whendecidingonalocationforthestove,considertheway
heatmovesthroughoutyourhome.Installthestovewhereyouneed
theheat;basementinstallationsoftendonotallowsuffic ient heatto
flowtotheupperfloorsandatopfloorinstallation
willnotallowany
heattoreachthefloorsbelow.Alwaysconsiderthatheatrisesandwill
takethepathofleastresistancewhileitisstillhot.

3. ExhaustLocation–Outsidewallsaregenerallythebestplacetoinstalla 
stove,sincetheyalloweasyexhaustandintakeair
installation(usingour
DuraVentAC‐3000Kit).Ifthereisnotafeasiblewaytoinstallthestove
onanoutsidewall,therearemethodsforventingthestoveupthrough
theroof,buttheytendtobemorecostlybecausetheyinvolvetheuse
ofmorepelletventpipe
andcanoftenmakeoutsideairinstallation
moredifficult.

4. WallConstruction–Locatingthestovesothattheexhaustsystemcan
passbetweenstudswillsimplifytheinstallationandeliminatetheneed
toreframeanysectionsofthewalltoaccommodatethewallthimble.

WARNING
ο‚· Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityof
thisoranyotherappliance.
ο‚· DoNotOverfire–Ifanyexternalpartstartstoglow,youareoverfiring.Reducefeed
rate.Overfiringwillvoidyourwarranty.
ο‚· Complywithallminimum
clearancestocombustiblesasspecified.Failuretocomply
mayresultinahousefire.
ο‚· Testedandapprovedforwoodpelletsonly.Burninganyotherfuelwillvoidyour
warranty.
Page | 7
INSTALLATION

ClearancestoCombustibles












UnittoSide
Wall
UnittoRear
Wall
Unitto
Corner

UnitTopto
Ceiling

Min.Ceiling
Height
Min.Alcove
Width
Max.Alcove
Depth
A B C D E F Notshown
12in. 6in. 6in. 28.5in. 60in. 48.25in. 24in.
304.8mm. 152.4mm. 152.4mm. 723.9mm. 1524mm. 1225.6mm. 609.6mm.
CAUTION
ο‚· Keepchildrenaway.
ο‚· Supervisechildreninthesameroomasthisappliance.
ο‚· Alertchildrenandadultstothehazardsofhightemperatures.
ο‚· DoNOToperatewithprotectivebarriersopenorremoved.
ο‚· Keepclothing,furniture,draperiesandothercombustiblesaway.
ο‚· InstallationMUSTcomplywithlocal,regional,stateandnationalcodesand
regulations.
ο‚· Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdictionabout
restrictions,installationinspection,andpermits.
A
B
C
C
D
E
F
DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM
Page | 8
INSTALLATION
VentingIntroduction
 Thispelletstoveoperatesonanegativedraftsystem,whichpullscombustionair
throughtheburnpotandpushestheexhaustairthroughtheventpipeandoutofthebuilding.
Thisunitmustbeinstalledinaccordancewiththefollowingdetaileddescriptionsofventing
techniques;notinstallingthestoveinaccordancewiththedetailslistedherecanresultinpoor
stoveperformance,propertydamage,bodilyinjuryordeath.England’sStoveWorksisnot
responsibleforanydamageincurredduetoapoororunsafeinstallation.
 Ifquestionsarisepertainingtothesafeinstallationofthestove,ourTechnicalSupport
line(800‐245‐6489)isavailable.Contactyourlocalcodeofficialtobecertainyourinstallation
meetslocalandnationalfirecodesandifyou’reuncertainabouthowtosafelyinstallthestove,
westronglyrecommendcontactingalocalNFIcertifiedinstallertoperformtheinstallation.
VentingGuidelines
ο‚· ALWAYSinstallventpipeinstrictadherencewiththeinstructionsandclearanc es
includedwithyourventingsystem.
ο‚· DONOTconnectthispelletstovetoachimneyfluewhichalsoservesanotherappliance.
ο‚· DONOTinstallafluepipedamperoranyotherrestrictivedeviceintheexhaustventing
systemofthisunit.
ο‚· USEanapprovedwallthimblewhenpassingthroughawallandaceilingsupport/fire
stopwhenpassingthroughaceiling.
ο‚· ONLYuse3.0”or4.0”TypeLorTypePLpipeapprovedforpelletstoveventing;DONOT
usegalvanizedorB‐Ventpipe.
ο‚· SEALeachjointofpelletventwithhightemperaturesilicone(Part#AC‐RTV3)to
preventsmokespillageintothehome.
ο‚· AVOIDexcessivehorizontalrunsandelbows,asbothwillreducethedraftoftheventing
systemandwillresultinpoorstoveperformance.
ο‚· INCLUDEasmuchverticalpipeaspossibletopreventsmokefromtheunitfromentering
yourhomeintheeventofapoweroutage.
ο‚· INSPECTyourventingsystemoften,tobecertainitisclearoffly‐ashandother
restrictions.
ο‚· CLEANtheventingsystemasdetailedinthemaintenancesectionof
thismanual.
WARNING:VentingsystemsurfacesgetHOT,andcancauseburnsiftouched.
Noncombustibleshieldingorguardsmayberequired.
WARNING
ο‚· INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
ο‚· HOT!Donottouch!Severeburnsorclothingignitionmayresult.
ο‚· Glassandothersurfacesarehotduringoperation.
Page | 9
INSTALLATION

AdditionalVentingInformation
ο‚· Donotmixandmatchcomponentsfromdifferentpipemanufacturerswhenassembling
yourventingsystem(i.e.DoNOTuseventingpipefromonemanufacturerandathimble
fromanother).

ο‚· Werequireaminimumverticalriseof36in.(3ft.)ofpipetocreatenaturaldraftinthe
system,whichhelpsevacuatesmokefromthestoveintheeventofapowerfailureor
combustionblowerfailure.
ο‚· Ventingsystems15.0ft.orshortermaybecomposedentirelyof3.0in.pelletpipe;to
reducefrictionallosses,ventingsystemslongerthan15.0ft.shouldbecomposedof4.0
in.pelletpipe.

ο‚· Donotterminatetheventingsystemdirectlybeneathanycombustiblestructuresuchas
aporchordeck.

ο‚· FollowNFPA211ruleslistedbelowforventingsystemterminationlocationrelativeto
windowsandotheropeningsinthedwelling.
o NFPA211(2003ed.)Section10.4Termination:10.4.5
(1)Theexitterminalofamechanicaldraftsystemotherthandirectvent
appliances(sealedcombustionsystemappliances)shallbelocatedinaccordance
withthefollowing:
 (a)Notlessthan3ft.(.91m)aboveanyforcedairinletlocatedwithin10
ft.(3.0m).
 (b)Notlessthan4ft.(1.2m)below,4ft.(1.2m)horizontallyfromor1ft.
(305mm)aboveanydoor,windoworgravityairinletintoanybuilding.
 (c)Notlessthan2ft.(0.61m)fromanadjacentbuildingandnotlessthan
7ft.(2.1m)above
gradewhenlocatedadjacenttopublicwalkways.

ο‚· Distancebetweentheterminationopeningandgradeshouldbeaminimumof24in.
contingentonthegradesurfacebelowthetermination.Whendeterminingthe
terminationheightabovegrade,considersnowdriftlinesandcombustiblessuchas
grassorleafaccumulation.Inareaswheresignificantsnowfallispossible,the
terminationheightmustbesufficientlyhightokeeptheterminationfreeofsnow
accumulation.
ο‚· Donotusemakeshiftcompromisesduringinstallationorinstallanycomponentofthe
unitorventingsystemwhichcouldresultinahazardousinstallation.
ο‚· Achimneyconnectorshallnotpassthroughanatticorroofspace,closetorsimilar
concealedspace,orafloor,orceiling.
ο‚· Wherepassagethroughawall,orpartitionofcombustiblematerialisdesired,the
installationshallconformtoCAN/CSA‐B365.
Page | 10
INSTALLATION

ApprovedVentingMethod1
:ThroughtheWall

ο‚· Generallythesimplestinstallationmethod,
ventingthroughthewallusingourAC‐3000
kit(orsimilarventingsystem)isalsothe
preferredventingmethod.Itminimizes
horizontalpipe,allowsthestovetobe
installedclosetothewallandkeepsthe
clean‐outteeontheoutsideofthe
house,
foreaseofcleaning.
ο‚· Wheninstallinganyventingsystem,TypeL
orTypePLpipemustbeusedandall
clearancestocombustibles(listedbythe
pipemanufacturer)mustbestrictly
adheredto.
ο‚· Usethepipemanufacturer’sapproved
thimbleforpassingthroughacombustible
wall,andmaintainatleasttheminimumclearancestocombustibles.
ο‚· Useanappliancecollarwherethepelletventconnectstotheexhaustoutputofthepellet
stoveandattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
ο‚· Securethepelletventtotheoutsideofthehouseusingawallstrapjustbelowthe90
degreeelbow.
ο‚· SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecificventingsystemmanufacturer’sinstructionsbeforedoing
so).
ο‚· Ifthepelletventpipebeingusedisnotaξ€ƒβ€œTwist
Lock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
ο‚· Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveor
usinganalternativemethod,asdescribedintheξ€ƒβ€œOutsideAir”section,onpage14.
ο‚· Thisinstallationtypecanbe
modifiedforbasement(Basementinstallationsshouldalways
beperformedbyaprofessionalinstaller)orotherinstallationswhereintheteeandvertical
sectionofthepipewouldbeinsidethehomeandtheventingsystemwouldsimplypass
horizontallythroughthethimbleandthenterminate.
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(
4”
)
.
Page | 11
INSTALLATION

ApprovedVentingMethod2
:ThroughtheCeiling

ο‚· Ventingthroughtheceiling/roofmaybetheonly
feasibleventingoptioninsomecasesandisafactory
recommendedinstallation.
ο‚· Wheninstallinganyventingsystem,TypeLorType
PLpipemustbeusedandallclearancesto
combustibleslistedbythepipemanufacturermust
bestrictlyadheredto.

ο‚· Usethepipemanufacturer’sapprovedceiling
supportforpassingthroughacombustibleceiling,as
wellastherequiredfirestops,radiationshields,
flashingandstormcollar.
ο‚· Becertaintofollowthemanufacturer’srequired
heightofterminationabovetheroofline,and
maintainatleasttheminimumclearancesto
combustibles.
ο‚· Useanappliancecollarwherethepelletvent
connectstotheexhaustoutputofthepelletstove
andattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
ο‚· SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
ο‚· Ifthepelletventpipebeingusedisnotaξ€ƒβ€œTwistLock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
ο‚· Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyour
stoveor
usinganalternativemethod,asdescribedintheξ€ƒβ€œOutsideAir”section,onpage14.
ο‚· Thisventingmethodcanalsobemodifiedsothattheventingsystemrunshorizontally
throughthewallfromthestove,thentransitionstoverticalandterminatesabovethe
roofline.Whenusingthismodifiedversionofthisinstallationbecertaintocarefullyfollow
theventingsystemmanufacturer’sinstructionsdiligently.

Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(
4”
)
.
Page | 12
INSTALLATION

ApprovedVentingMethod3
:ExistingChimneySystem
ο‚· Usinganexistingmasonryorfactorybuiltchimneyfor
ventingistheonlyotheracceptablemethodfor
ventingthispelletunit.
ο‚· UseTypeLorTypePLventingpipeuntilenteringthe
existingchimney.Usetheappropriatelysizedadapter
whentransitioningfromthepelletventpipetothe
masonryorfactorybuiltthimbleandbecertainthat
theadapterissealedtightlytoboththepelletventing
systemandtheexistingchimney.
ο‚· Beforeusinganexistingchimney,becertainitisin
goodcondition(Achimneysweepinspectionishighly
recommended).Also,makesurethechimneymeets
theminimumstandardslistedinNFPA211(A
chimneyprofessionalcanconfirmthisupon
inspection).
ο‚· Ifconnectingthisstovetoafactorybuiltchimney,it
mayONLYbea6”flue,UL103HTventingsystem.
Connectiontoanyotherfactorybuiltchimneymay
resultinapoorlyoperatingordangerousstove
installation.
ο‚· Whenconnectingtoanexistingmasonrychimney,thecross‐sectionalareaofthefluemust
beconsidered.Achimneywithafluelargerthan6”round(28.27sq.in.)mayrequire
reliningwithanapprovedpelletstovechimneyliningsystem.
ο‚· Useanappliancecollarwherethepellet
ventconnectstotheexhaustoutputofthepellet
stoveandattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
ο‚· SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
ο‚· Ifthepelletventpipebeingusedisnotaξ€ƒβ€œTwistLock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
ο‚· Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveor
usinganalternativemethod,asdescribedintheξ€ƒβ€œOutsideAir”section,onpage14.



Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(
4”
)
.
Page | 13
INSTALLATION
MobileHomeInstallation
ο‚· TheEngland’sStoveWorks,Inc.outsideairkitMUSTbeusedforinstallationofthisunitina
mobilehome.Pleaseseetheξ€ƒβ€œOutsideAir”sectiononpage14formoreinformation
regardingoutsideairconnections.
ο‚· Theoutsideairinletmustbekeptclearofleaves,iceandotherdebris.Keepingtheoutside
airinletfreeofrestrictioniscrucialtopreventingairstarvationandsmokespillage.
ο‚· ThepelletstoveMUSTbesecuredtothefloorofthemobilehomeusinglagboltsandthe
holesprovidedinthebottomofthebaseforthispurpose.Outdoor‐aired
spaceheaters
mustbeattachedtothestructure.
ο‚· ThepelletstoveMUSTbegroundedwith#8solidcoppergroundingwire(orequivalent),
terminatedateachendwithanNECapprovedgroundeddevice.
ο‚· CarefullyfollowallclearanceslistedintheappropriatesectionofthismanualANDfollow
theventing
manufacturer’sminimumclearancerequirements.Similarly,becertainthe
ventingsystemusedisapprovedformobilehomeuse.
ο‚· InstallationmustbeinaccordancewithManufacturersHome&SafetyStandard(HUD)CFR
3280,Part24aswellasanyapplicablelocalcodes.
ο‚· Usesiliconetocreateaneffectivevaporbarrieratthelocationwherethechimneyor
outsideairductingpassesthroughtotheexteriorofthestructure.






WARNING:DONOTINSTALLINASLEEPINGROOM.
CAUTION
THESTRUCTURALINTEGRITYOFTHEMANUFACTUREDHOMEFLOOR,WALL
ANDCEILING/ROOFMUSTBEMAINTAINED.
DONOTCUTTHROUGHFLOORJOISTS,WALLSTUDS,CEILINGTRUSSESORANY
OTHERSUPPORTINGMATERIALWHICHCOULDBEDETRIMENTALTOTHE
STRUCTURALINTEGRITYOFTHEHOME.
JoistShield/Firestop
MobileHome
ApprovedTypePorPL
PelletVentPipe
RoofFlashingand
StormCollar
ChimneyCap/SparkArrestor
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(
4”
)
.
Page | 14
OUTSIDEAIRHOOK‐UP

ο‚· Theuseofoutsidecombustionairismandatoryonthispelletstove.
ο‚· Theoutsideairconnectionpipeprotrudesfromthelowerrearcenterofthestove;usethe
includedoutsideairkittoattachyourstovetooutsidecombustionair.Instructionsandall
thepartsneededtomakethe
outsideairconnectiontoyourpelletstoveareincludedwith
theoutsideairkit.
ο‚· Ifitisnotfeasibletousetheincludedoutsideairhookupkitinyourstoveinstallation,other
materialsmaybeused,providedthefollowingrulesarefollowed:
o Thepipeusedforoutsideairhookupmustbemetal,withaminimumthicknessof
.0209in.(25gaugemildsteel)orgreaterandaninsidediameterofapproximately
2.0in.
o Allpipejointsandconnectionsshouldbesealedwithpipeclampsorother
mechanicalmeans,toinsurealeakfreeoutsideairconnection.
o Longrunsofpipeandexcessiveelbowsforoutsideairshouldbeavoided.Dueto
frictionalresistanceinpipe,anyexcessiveoutsideairpipingcanresultinpoorstove
performance.
o Ascreenorotherprotectiondevicemustbefittedovertheoutsideairtermination
pointtopreventrain,debrisandnuisanceanimalsfromenteringthepipingsystem.
o Increasetheoutsideairpipesizeto3.0in.diameterpipeiftheoutsideair
connectionismorethan6ft.inlength,morethantwo(2)elbowsareusedorifthe
stoveisinstalledinabasement.

ο‚· Theoutsideairconnectionsystemshouldbeinspectedatleastannuallytobecertainitis
freefromblockage.






Caution
NEVERdrawoutsidecombustionairfrom:
ο‚· Wall,floororceilingcavity.
ο‚· Enclosedspacesuchasanattic,garageorcrawlspace.
Page | 15
FLOORPROTECTION

ο‚· Thispelletstoverequiresanon‐combustiblefloorprotectorifthestoveistobeinstalledon
acombustiblefloor.Ifthefloorthestoveistobeinstalledonisalreadynon‐combustible
(i.e.aconcretefloorinabasement)andhasanRvalueequaltoor
higherthan.2,nofloor
protectionisneeded(althoughadecorativefloorprotectorcanstillbeusedforaesthetic
reasons).
ο‚· PrefabricatedfloorprotectorswhichareULlistedorequivalentcanbepurchasedorafloor
protectorcanbebuiltfromstandardmaterials;twosheetsof.5”thickcementboard
covered
withceramictilewouldbeasuitablefloorprotectorwhichmeetsthe.2R‐value
requirement.
ο‚· Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduce
heatingandcoolingcyclesonthefloorprotectorwhichcandamagetileandloosenmortar
andgroutjoints.AhearthrugisNOTanapprovedsubstituteforaproperhearthpad.
ο‚· FortheUS:Thefloorprotectormustextendatleast6in.(152.4mm)fromthefront&sides
and4in.(101.6mm)fromtherear.
ο‚· ForCanada:Thefloorprotectormustextendatleast18.0in.(457.2mm)fromthefrontof
theunit,8.0in.(203.2mm)fromthesidesoftheunitand4.0in.(101.6mm)fromtherear.












ο‚· InCanada,itisrequiredthatthenon‐combustiblefloorprotectorisunderneathand
extends2in.(50.8mm.)oneithersideofanyhorizontalventingrunsAND/ORisdirectly
underneathanyverticalventingpipe.
US:6.0in.
Canada:

8.0

in.

US:6.0in.
Ca
n
ada
:
8
.
0
in.
US:4.0in.
Ca
n
ada
:4.
0
in.
US:6.0in.
Ca
n
ada
:1
8
.
0
in.
Page | 16
DAILYOPERATION

GettingStarted
ο‚· Checktoseethatthehopperiscleanandfreefromforeignmaterials.Besuretoconnect
thisunittoaworkingoutlet;werecommendusingasurgeprotectortohelpprotectthe
electroniccomponentsfromdamage.
ο‚· BEFOREyourfirstfire,dryrunyourunit(nopelletfuelinthehopper)fortwentyminutes;
pressingtheξ€ƒβ€œON”buttonwiththeunitpluggedinwillinitiatethedryrun.
o Oncetheξ€ƒβ€œON”buttonispressed,youshouldimmediatelyheartheexhaustblower
startandoperatecontinuously.
o Afteraboutthreetofiveminutes,lookfortheredglowoftheigniterintheigniter
portoftheburnpottobecertainitisoperatingnormally.
o Holdthehopperlidswitch(Seeξ€ƒβ€œIllustratedPartsDiagram”pg.38)downwithyour
fingerandchecktoseethattheaugeristurning.Releasethehopperlidswitchand
becertainthattheaugerstopsturning.DONOTPUTYOURFINGERSINTHE
HOPPERORNEARTHEROTATINGAUGER.
ο‚· Afterabouttwentyminutes,thecontrolboardshoulddisplayξ€ƒβ€œE‐2”inthetwodisplay
windows(MoreinformationonErrorCodescanbefoundintheErrorCodesectionofthis
manual).
ο‚· Atthispoint,thedryruniscompleteandyourpelletheatingapplianceisreadyfornormal
operation.
LightingaFire


ο‚· Inorderforthisstovetooperate,thehoppermustfirstbefilledwithpelletfuel.Liftthe
hopperlidusingtheflush‐mounthandleandpourthepelletfueldirectlyintothehopper.
 WerecommendusingonlypelletsmanufacturedbyPFICertifiedfacilities,since
pelletsbearingthePFIstampofapprovalwillbelowinashandmoisture,highin
BTU’s,anduniforminsizeandquality.

ο‚· Thispelletstovewillperformequallywellusingsoftwoodandhardwoodpellets,and
althoughtheashmaydifferslightlyinappearanceortexture,bothtypesofpelletswillburn
cleanlyandefficientlyinthisstove.
ο‚· Thispelletstoveisequippedwithanautomaticpelletignitionsystem;theonlyuserinput
requiredtolightthestoveisasimplepressoftheξ€ƒβ€œOn”button.
Page | 17
ο‚· Shortlyafterpressingtheξ€ƒβ€œOn”button,thelettersξ€ƒβ€œSU”willappearintheheatrangeand
blowerspeedwindowsofthecontrolboard.Thisindicatesthestovehasenteredthestart‐
upsequenceandisoperatingnormally.
ο‚· Thefuelfeedrateandcombustionairduringstart
‐upisdeterminedbythecontrolboard,so
thestovemaybestartedonanyheatrange.
ο‚· Afterapproximatelyfifteenminutes,thefireshouldbeburningbrightlyandtheξ€ƒβ€œSU”
shoulddisappearfromthecontrolboard.Atthispoint,thestovehasbegunnormal
operationandthedisplaywindowsonthecontrolboardwillremainempty,unlesstheHeat
RangeorBlowerSpeedisadjusted.
DailyOperationNotes
ο‚· Onlyhighquality,¼”(.25in.)diameterwoodpellets,shouldbeusedinthisstove.Usinglow
gradewoodpelletswithhighashcontentORwoodpelletswithahighmoisturecontent
cancausetheburnpottofillwithashatamorerapidpaceandcancauseintervalsbetween
periodicmaintenancetobecomesignificantlyshorter.Pleasereadtheξ€ƒβ€œMaintenance”
sectionofthismanualthoroughlytounderstandhowfuelselectionaffectsstoveoperation,
maintenanceandcleaning.
ο‚· Variationintheflameheightisnormal;notallwoodpelletfuelisuniforminsize,whichcan
affectthewaypelletsarefedintotheburnpot.Althoughtheflameheightmayincreaseand
decreaseduringoperation,thereisnolossofefficiency.
ο‚· Alwaysstorewoodpelletfuelinadrylocation;storingwoodpelletfuelinadrylocation
ensuresthefuelwillremainpelletizedandlowinmoisturecontent.Also,becertainthatall
woodpelletfuelisstoredatasafedistancefromthepelletheater;storingfuelinclose
proximitytothestovecanresultinafire.
ο‚· Thispelletburningroomheaterisequippedwithaspeciallydesignedburnpotwhichcomes
preinstalledfromthefactory.Thisburnpot
elevatestheburningpelletsanddeliversairat
thepreciserequiredlocations.Pelletsmustonlybeburnedinthefactoryburnpot;no
modificationsshouldbemadetothisburnpotandnoadditionalgratesorotherfire
elevatorsshouldbeadded.
CAUTION
NEVERUSEGASOLINE,GASOLINE‐TYPELANTERNFUEL,KEROSENE,CHARCOALLIGHTER
FLUID,ORSIMILARLIQUIDSTOSTARTORξ€ƒβ€œFRESHENUP”AFIREINTHISHEATER.KEEPALL
SUCHLIQUIDSWELLAWAYFROMTHEHEATERWHILEINUSE.ADDITIONALLY,NEVER
APPLY FIRE
‐
STARTER TO ANY HOT SURFACE OR EMBERS IN THE STOVE.
DONOTUSECHEMICALSORFLUIDSTOSTARTTHEFIRE.
DONOTBURNGARBAGEORFLAMMABLEFLUIDSSUCHASGASOLINE,NAPHTHAOR
ENGINEOIL.
Page | 18
CONTROLBOARDSETTINGS
Thecontrolboardonthisstoveallowstheusertoadjusttheheatoutputandconvection
blowerspeed,turntheunitonandoff,andtestcomponentsforfunction(moreondiagnostic
modelater).
ο‚· Thelowerbuttonsonthecontrolboard(LowFuelFeed,LowBurnAir,andAiron
Temp)are
notmeanttobeadjustedduringnormaloperationoftheunit.Thesebuttonsarefactory
presetandcannotbeadjustedbytheuser.
ο‚· Toenergizetheunitandinitiateafire,presstheξ€ƒβ€œOn”button.TheLEDabovethebutton
shouldturngreenandthecontrol
boardshoulddisplayξ€ƒβ€œSU”shortlyafterpressingthe
button.
ο‚· Toshuttheunitdown,presstheξ€ƒβ€œOff”button.TheLEDabovethebuttonshouldturnred
andtheboardshoulddisplayξ€ƒβ€œSd”shortlyafterpressingthebutton.Thisinitiatestheshut 
downsequence,andthestovewillremaininshutdownmodeuntilithascooleddown.
ο‚· Toincreasetheheatoutputofthestove,presstheξ€ƒβ€œUp”heatrangebutton.Thenumberin
theheatrangedisplaywindowwillincrease,signifyingthatthecontrolboardisnow
adjustingtheheatoutputtoyourdesiredlevel.Theblowerspeedwillincreasethesame
amountastheheatrange,becausethestoveisdesignedtooperatewiththeblowerspeed
greaterthanorequaltotheheatrange.Pressingtheξ€ƒβ€œDown”arrowwilldecreasetheheat
rangeandblowerspeed.
ο‚· Toincreasetheblowerspeedwithoutincreasingtheheatrange,presstheBlowerSpeed
β€œUp”arrowuntilthedesiredblowerspeedisshowninthedisplaywindow.Pressingthe
β€œDown”arrowwilldecreasetheblowerspeed;however,thecontrolboardwillnotallow
theblowerspeedtobesetlowerthantheheatrange.
Caution
Thisunitismeanttooperateonlywiththeashpanandmainviewing
doorclosed.Smokespillageandaninefficient,lazyburnwillresult
fromattemptingtooperatethestovewitheitherdooropen.
Inaddition,usingfuelotherthanwoodpelletscancreateanunsafe
situationandcanalso
generateexcesscarbonmonoxide.Carbon
monoxideisanodorless,colorlessgaswhichcanbedeadly.Pleaseburn
onlywoodpellets.
Page | 19
ERRORCODES
Errorcodes,orξ€ƒβ€œE‐Codes,”arealphanumericcodesthatwillappearintheHeatRangeand
BlowerSpeedwindowsoftheControlBoardiftheunitexperiencesanabnormalcondition.
Errorcodesarethecontrolboard’swayoftellingtheuserthatsomethingisn’toperating
correctlywithinthestove,andthattheunitshouldbecarefullyinspectedbeforereigniting.See
theξ€ƒβ€œTrouble‐ShootingGuide,”page30,foradditionalinformationonerrorcodes.
 E‐0
οƒ˜ Whenthisisdisplayedinthecontrolboardwindows(typicallywhenrestartingafter
anξ€ƒβ€œE‐Code”shutdown),itmeanstherearecurrentlynoerrorsandthestovewill
beginnormaloperation.
 E‐1

οƒ˜ Thiserrorcodeisnotusedonthisstove.Ifitisdisplayedinthecontrolboard
windows,pleasecontactTechnicalSupportandtheywilldiagnosethecauseofthe
falsecode.
 E‐2

οƒ˜ Whenthiscodeisdisplayedinthecontrolboardwindowitindicatesafailureto
light.Althoughthestovemayhaveignitedthepellets,thecontrolboarddidnot
registerahighenoughtemperaturetodeterminethefirewaslit.Ifafirewas
ignited,waitfortheunittocool,cleantheburnpotandrestarttheunit.
 E‐3
οƒ˜ Thiserrorcodeindicatesthepresetmaximumallowableexhausttemperaturewas
exceeded.Commonlyreferredtoasξ€ƒβ€œOver‐Firing,”theE‐3codemeanssomethingin
thestoveiscausingtheexhaustgastobehotterthanexpected.
 E‐4
οƒ˜ Thiscodeisdisplayedbasedonadropintheexhausttemperature.Thiscodemeans
thefireorξ€ƒβ€œproofofflame”hasbeenlost.Itusuallyresultsfromthehopperbeing
empty.


If an error code continues to display, if the error code
seems unexplainable, or if you have any other
questions about error codes and what they mean,
please contact Technical Support at (800)245-6489.
Page | 20
POWERFAILURE
Ifthepowertotheunitisinterruptedforapproximatelythreeminutesorless,theunitwill
resumeoperationwhenpowerisrestoredaccordingtothefollowingtable:

Unit’sStateBeforePowerLoss StateWhenPowerReturns
ON Start‐Up
Start‐Up Start‐Up
Shut‐Down Shut‐Down
OFF OFF

οƒ˜ Ifthepowerisinterruptedformorethan(approximately)threeminutes,theunit
willbeξ€ƒβ€œOFF”whenpowerreturns.
οƒ˜ IMPORTANT–DoNOTopenthehopperlidorthedoortotheunitduringpower
outage.Opentheclosestoutsidedoorandawindowtoreducethechanceofany
combustionbyproductsenteringthehomefromthestove.
οƒ˜ Waitforthepowertoberestoredandthenpresstheξ€ƒβ€œON”buttontorestartthe
unit,ifnecessary.
Caution
ShockHazard
Presstheξ€ƒβ€œOff”buttonandlettheappliancecompletelycoolBEFORE
unpluggingtheapplianceandbeginninganymaintenanceorcomponent
replacement.
Riskofshockifapplianceisnotunpluggedbeforeservice.
SmokeDetectors
England’sStoveWorks,Inc.highlyrecommendstheuseofsmokedetectorsin
everyroomofthehouse.However,locatingasmokedetect ordirectlyabove
thisunitcanresultinnuisance alarms.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

England's Stove Works Gas Heater 55SHPAH User manual

Category
Stoves
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI