Summers Heat 55-SHPIPL User manual

  • Hello! I am an AI chatbot trained to assist you with the Summers Heat 55-SHPIPL User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
IMPERIALPELLETSTOVE


CAUTION
PLEASEREADTHISENTIREMANUALBEFOREINSTALLATIONANDUSEOFTHISPELLETFUELBURNING
APPLIANCE.KEEPCHILDREN,FURNITURE,ANDALLCOMBUSTIBLESAWAYFROMANYHEATINGAPPLIANCE.
SAFETYNOTICE
FAILURETOFOLLOWTHESEINSTRUCTIONSCANRESULTINPROPERTYDAMAGE,BODILYINJURYOREVEN
DEATH.FORYOURSAFETYANDPROTECTION,FOLLOWTHEINSTALLATIONINSTRUCTIONSOUTLINEDIN
THISMANUAL.CONTACTYOURLOCALBUILDINGORFIREOFFICIALSABOUTRESTRICTIONSAND
INSTALLATIONINSPECTIONREQUIREMENTS(INCLUDINGPERMITS)INYOURAREA.
ManufacturedBy:
England’sStoveWorks,Inc.
POBox206
Monroe,VA24574
9/20/2012
SAVETHESEINSTRUCTIONS
INSTALLATION&OPERATION
MANUAL
25IP/55SHPIP/55TRPIP
25IPS/55SHPIPS/55TRPIPS
2
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE
UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO
UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
IMPORTANT:IFYOUHAVEAPROBLEMWITHTHISUNIT,DONOTRETURNITTO
THEDEALER.CONTACTTECHNICALSUPPORT@18002456489
MobileHomeUse:
Thisfreestandingpelletunitisapprovedformobilehomeordoublewide
installationwiththeoutsidecombustionairhookup.Seethe“Installation”
sectionofthismanualfordetailspertainingtomobilehomeinstallations.Mobile
homeinstallationmustbeinaccordancewiththeManufacturedHomeandSafety
Standard(HUD),CFR3280,Part24.
WARNING:
USEOFOUTSIDECOMBUSTIONAIRISMANDATORYWITHTHISUNIT.
DONOTOPERATEWITHTHEHOPPEROPEN;LIDMUSTBESHUTANDTIGHTLY
LATCHEDDURINGOPERATION.
Note:England’sStoveWorksdoesnotrecommendusingapelletstoveasyour
onlysourceofheat.
Retain for your files
Model Number
Date of Purchase
Date of Manufacture
Serial Number
3
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE
UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO
UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
TABLEOFCONTENTS
Introduction
x Introduction.......................................4
Specifications
x HeatingSpecifications.......................5
x Dimensions........................................5
x EPACompliance.................................5
Installation
x InstallationOverview.........................6
x ClearancestoCombustibles..............7
x VentingIntroduction.........................8
x VentingGuidelines............................8
x AdditionalVentingInformation.........9
x ApprovedVentingMethods
x ThroughtheWall................10
x ThroughtheCeiling............11
x ExistingChimney................12
x MobileHomeInstallation................13
x VentTerminationClearances..........14
x OutsideAirHookup.........................15
x FloorProtection...............................16
DailyOperation
x GettingStarted................................17
x LightingaFire.............................1718
x ControlBoardSettings....................19
x ErrorCodes......................................20
x PowerFailure...................................21
x ThermostatInstallation...................22
x ThermostatOperation................2223
x OptionalAccessories.......................23
Maintenance
x Daily
x ImportantNotes.................24
x DailyAshRemoval.........2425
x CleaningtheBurnPot.........25
x Biweekly
x BaffleRemoval...................26
x Monthly
x ImportantNotes............2627
x ExhaustChamber...........2728
x VentingPipe.......................28
x Yearly
x ImportantNotes.................29
x ExhaustBlower...................30
x ConvectionBlower.............30
x CradleRemoval..................31
x HopperFines......................31
x CheckingGaskets...............31
TroubleshootingGuide
x Troubleshooting.........................3233
ReplacingComponents
x AugerMotor....................................34
x ConvectionBlower..........................35
x CombustionBlower.........................35
x VacuumSwitch................................36
x Igniter..............................................36
x Gaskets............................................37
x Glass................................................38
x ControlBoard..................................39
x WiringDiagram...............................40
x HopperLidLatches..........................41
x DoorLatch.......................................42
x Magnets..........................................42
x HopperLid.......................................42
x Fiberboard.......................................43
x Panels..............................................43
x Finish...............................................43
IllustratedPartsDetail
x ExplodedPartsDiagram..................44
x PartsList.....................................4546
OtherDetails
x AshPanLatches..........................46
Warranty
x SerialTagSample............................47
x WarrantyDetails........................4849
x ImportantNotice.............................50
x WarrantyReg.Form........................51
4
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INTRODUCTION
ThankyouforpurchasingthisfineproductfromEngland’sStoveWorks!
England’sStoveWorkswasstarted,andisstillownedby,afamilythat
believesstronglyina“DoItYourself”spirit;that’sonereasonyoufoundthis
productatyourfavorite“DoItYourself”store.
Weintentionallydesignandbuildourstovessothatanyhomeownercan
maintaintheirunitwithbasictools,andwe’realwaysmorethanhappyto
showyouhowtodothejobaseasilyandasinexpensivelyaspossible.
However,whileremainingsimple,ourstovesaredesignedtoperform
extremelyefficiently,helpingdelivermoreheatfromlessfuel.
PleaselookatourvastHelpsectiononourwebsiteandcallourTechnical
SupportDepartmentat(800)2456489ifyouneedanyhelpwithyourunit.
Wearenearlyalwaysableto“walkyouthrough”anyinstallationissues,
repairs,problemsorotherquestionsthatyoumayhave.
Wishingyouyearsofefficient,qualityand“comfy”heating,
EVERYONEATENGLANDSSTOVEWORKS
PleaseNote
:Whileinformationobtainedfromourwebsiteandthroughour
TechnicalSupportlineisalwaysfreeofcharge,therewillbeaservicecharge
incurredwithany“onsite”repairsormaintenancethatwemayarrange.
Thismanualencompassesallversionsofthe25IP,includingthe55SHPIP,55SHPIPLand55TRPIP.Thisalso
appliestothestraightversionofthisunitwithmodelnumbers25IPS,55SHPIPSand55TRPIPS.However,for
simplicityofdescription,thestovewillbereferredtobythegeneric25IPdesignation.
5
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
SPECIFICATIONS
HeatingSpecifications
x HeatOutputRange**....................................................................14,108to35,023BTU/hr
x ApproximatePelletBurnRate**..........................................................0.945to2.346kg/hr
x MaximumBurnTime**..........................................................................................38hours
x ApproximateSquareFootageHeated***................................................upto2,200sq.ft.
x HopperCapacity...................................................................................................80pounds
Dimensions
 
EPAandSafetyComplianceSpecifications
x EPACompliance.......................................................................................................Certified
x ParticulateEmissions......................................................................................1.78grams/hr
x Efficiency*......................................................................................................................78%
x TestedTo..................UL148200,ASTME1509,ULC/ORDC1482M1990&ULCS62700
Notesforthisunit:Picturemaynotmatchyourunitifyouhavethestraightversion.Clearances
aretheminimumforthisunitandmayneedtobeincreasedinthereartohavepropervent
clearances.Followallventingmanufacturerclearancesandlocalcodes.
*Thisunitwasnottestedforefficiency;theefficiencyshownisadefaultvaluenormallyattainedbysimilar,certifiedpelletburningappliances.
**Heatoutput,burnrateandmaximumburntimeareheavilydependentonthetypeofpelletsburnedinthestove;assuch,thesenumbersmayvary.
***Themaximumheatingcapacityofthisunitcanvarygreatlybasedonclimate,constructionstyle,insulationandamyriadofotherfactors.Usethis
informationinconjunctionwithaBTUlosscalculationforyourhometodetermineifthisunitwillbesufficientforyourneeds.
6
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
InstallationOverview
Whenchoosingalocationforyournewstove,thereareamultitudeoffactors
thatshouldbetakenintoaccountbeforebeginningtheinstallation.
1. TrafficPatterns–Tohelppreventaccidents,thestoveshouldbeplacedina
locationwhereitisoutofthewayofnormaltravelthroughthehome.
2. HeatFlow–Whendecidingonalocationforthestove,considerthewayheat
movesthroughoutyourhome.Installthestovewhereyouneedtheheat;
basementinstallationsoftendonotallowsufficientheattoflowtotheupper
floorsandatopfloorinstallationwillnotallowanyheattoreachthefloors
below.Alwaysconsiderthatheatrisesandwilltakethepathofleast
resistancewhileitisstillhot.
3. ExhaustLocation–Outsidewallsaregenerallythebestplacetoinstallastove,
sincetheyalloweasyexhaustandintakeairinstallation(usingourDuraVent
AC3000Kit,AC33000ifCanada).Ifthereisnotafeasiblewaytoinstallthe
stoveonanoutsidewall,therearemethodsforventingthestoveupthrough
theroof,buttheytendtobemorecostlybecausetheyinvolvetheuseofmore
pelletventpipeandcanoftenmakeoutsideairinstallationmoredifficult.
4. WallConstruction–Locatingthestovesothattheexhaustsystemcanpass
betweenstudswillsimplifytheinstallationandeliminatetheneedtoreframe
anysectionsofthewalltoaccommodatethewallthimble.
WARNING
x Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityofthisoranyother
appliance.
x DoNotOverfire–Ifanyexternalpartstartstoglow,youareoverfiring.Reducefeedrate.Overfiringwill
voidyourwarranty.
x Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymayresultinahouse
fire.
x Testedandapprovedforwoodpelletsonly.Burninganyotherfuelwillvoidyourwarranty.
7
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
ClearancestoCombustibles

UnittoSide
Wall(A)
UnittoRear
Wall(B)
UnittoCorner
(C)
UnitTopto
Ceiling
Min.Ceiling
Height
6in. 6in. 3in. 9in. 60in.
152.4mm 152.4mm 76.2mm 228.6mm 1524mm
Alcoveinstallationnotrecommendedforthisunit
CAUTION
x UnitcanbeveryHOTwhileinoperation.Keepchildrenaway.
x Supervisechildreninthesameroomasthisappliance.
x Alertchildrenandadultstothehazardsofhightemperatures.
x DoNOToperatewithprotectivebarriersopenorremoved.
x Keepclothing,furniture,draperiesandothercombustiblesaway.
x InstallationMUSTcomplywithlocal,regional,stateandnationalcodesandregulations.
x Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdictionaboutrestrictions,
installationinspection,andpermits.
DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM
8
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
VentingIntroduction
Thispelletstoveoperatesonanegativedraftsystem,whichpullscombustionairthroughthe
burnpotandpushestheexhaustairthroughtheventpipeandoutofthebuilding.Thisunitmustbe
installedinaccordancewiththefollowingdetaileddescriptionsofventingtechniques;notinstallingthe
stoveinaccordancewiththedetailslistedherecanresultinpoorstoveperformance,property
damage,bodilyinjuryordeath.England’sStoveWorksisnotresponsibleforanydamageincurreddue
toapoororunsafeinstallation.
Ifquestionsarisepertainingtothesafeinstallationofthestove,ourTechnicalSupportline
(8002456489)isavailable.Contactyourlocalcodeofficialtobecertainyourinstallationmeetslocal
andnationalfirecodesandifyou’reuncertainabouthowtosafelyinstallthestove,westrongly
recommendcontactingalocalNFIcertifiedinstallertoperformtheinstallation.
VentingGuidelines
x ALWAYSinstallventpipeinstrictadherencewiththeinstructionsandclearancesincludedwith
yourventingsystem.
x DONOTconnectthispelletstovetoachimneyfluewhichalsoservesanotherappliance.
x DONOTinstallafluepipedamperoranyotherrestrictivedeviceintheexhaustventingsystem
ofthisunit.
x USEanapprovedwallthimblewhenpassingthroughawallandaceilingsupport/firestopwhen
passingthroughaceiling.
x ONLYuse3.0”or4.0”TypeLorTypePLpipeapprovedforpelletstoveventing;DONOTuse
galvanizedorBVentpipe.
x SEALeachjointofpelletventwithhightemperaturesilicone(Part#ACRTV3)topreventsmoke
spillageintothehome.
x AVOIDexcessivehorizontalrunsandelbows,asbothwillreducethedraftoftheventingsystem
andwillresultinpoorstoveperformance.
x INCLUDEasmuchverticalpipeaspossibletopreventsmokefromtheunitfromenteringyour
homeintheeventofapoweroutage.
x INSPECTyourventingsystemoften,tobecertainitisclearofflyashandotherrestrictions.
x CLEANtheventingsystemasdetailedinthemaintenancesectionofthismanual.
WARNING
x INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
x HOT!Donottouch!Severeburnsorclothingignitionmayresult.
x Glassandothersurfacesarehotduringoperation.
x Donotattempttotouchoropenthefrontorsidepanelsduringoperation.Thiscouldresultinsevere
burnsorinjury.
9
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
AdditionalVentingInformation
x Donotmixandmatchcomponentsfromdifferentpipemanufacturerswhenassemblingyour
ventingsystem(i.e.DoNOTuseventingpipefromonemanufacturerandathimblefrom
another).
x Werequireaminimumverticalriseof36in.(3ft.)ofpipetocreatenaturaldraftinthesystem,
whichhelpsevacuatesmokefromthestoveintheeventofapowerfailureorcombustion
blowerfailure.
x Ventingsystems15.0ft.orshortermaybecomposedentirelyof3.0in.pelletpipe;toreduce
frictionallosses,ventingsystemslongerthan15.0ft.shouldbecomposedof4.0in.pelletpipe.
x Donotterminatetheventingsystemdirectlybeneathanycombustiblestructuresuchasa
porchordeck.
x FollowNFPA211ruleslistedbelowforventingsystemterminationlocationrelativetowindows
andotheropeningsinthedwelling.
o NFPA211(2006ed.)Section10.4Termination:10.4.5
(1)Theexitterminalofamechanicaldraftsystemotherthandirectventappliances
(sealedcombustionsystemappliances)shallbelocatedinaccordancewiththe
following:
(a)Notlessthan3ft.(.91m)aboveanyforcedairinletlocatedwithin10ft.
(3.0m).
(b)Notlessthan4ft.(1.2m)below,4ft.(1.2m)horizontallyfromor1ft.(305
mm)aboveanydoor,windoworgravityairinletintoanybuilding.
(c)Notlessthan2ft.(0.61m)fromanadjacentbuildingandnotlessthan7ft.
(2.1m)abovegradewhenlocatedadjacenttopublicwalkways.
x Distancebetweentheterminationopeningandgradeshouldbeaminimumof2ft.(24in.)
contingentonthegradesurfacebelowthetermination.Whendeterminingthetermination
heightabovegrade,considersnowdriftlinesandcombustiblessuchasgrassorleaf
accumulation.Inareaswheresignificantsnowfallispossible,theterminationheightmustbe
sufficientlyhightokeeptheterminationfreeofsnowaccumulation.
x Donotusemakeshiftcompromisesduringinstallationorinstallanycomponentoftheunitor
ventingsysteminsuchamannerthatcouldresultinahazardousinstallation.
x Achimneyconnector
shallnotpassthroughanatticorroofspace,closetorsimilarconcealed
space,orafloor,orceiling.
x Wherepassagethroughawallorpartitionofcombustiblematerialisdesired,theinstallation
shallconformtoCAN/CSAB365.
WARNING:
VentingsystemsurfacesgetHOT,andcancauseburnsiftouched.Noncombustibleshielding
orguardsmayberequired.
10
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
ApprovedVentingMethod1:ThroughtheWall
x Generallythesimplestinstallationmethod,ventingthrough
thewallusingourAC3000kit,AC33000ifCanada(orsimilar
ventingsystem)isalsothepreferredventingmethod.It
minimizeshorizontalpipe,allowsthestovetobeinstalledclose
tothewallandkeepsthecleanoutteeontheoutsideofthe
house,foreaseofcleaning.
x Wheninstallinganyventingsystem,TypeLorTypePLpipe
mustbeusedandallclearancestocombustibles(listedbythe
pipemanufacturer)mustbestrictlyadheredto.
x Usethepipemanufacturer’sapprovedthimbleforpassing
throughacombustiblewall,andmaintainatleasttheminimum
clearancestocombustibles.
x Useanappliancecollarwherethepelletventconnectsto
theexhaustoutputofthepelletstoveandattachtheappliance
collartotheexhaustbloweroutputusingthreesheetmetalscrews.
x Securethepelletventtotheoutsideofthehouseusingawallstrapjustbelowthe90degree
elbow.
x SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificventingsystemmanufacturer’sinstructionsbeforedoingso).
x Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
x Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
Thisinstallationtypecanbemodifiedforbasement(Basementinstallationsshouldalwaysbe
performedbyaprofessionalinstaller)orotherinstallationswhereintheteeandverticalsectionofthe
pipewouldbeinsidethehomeandtheventingsystemwouldsimplypasshorizontallythroughthe
thimbleandthenterminate.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeach
individualinstallation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,
andfollowalllocalcodes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(
3”
)
tofourinch
(
4”
)
.
11
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
ApprovedVentingMethod2:ThroughtheCeiling
x Ventingthroughtheceiling/roofmaybetheonlyfeasible
ventingoptioninsomecasesandisafactoryrecommended
installation.
x Wheninstallinganyventingsystem,TypeLorTypePLpipe
mustbeusedandallclearancestocombustibleslistedbythe
pipemanufacturermustbestrictlyadheredto.
x Usethepipemanufacturer’sapprovedceilingsupportfor
passingthroughacombustibleceiling,aswellastherequired
firestops,radiationshields,flashingandstormcollar.
x Becertaintofollowthemanufacturer’srequiredheightof
terminationabovetheroofline,andmaintainatleastthe
minimumclearancestocombustibles.
x Useanappliancecollarwherethepelletventconnectsto
theexhaustoutputofthepelletstoveandattachtheappliance
collartotheexhaustbloweroutputusingthreesheetmetal
screws.
x SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
x Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
x Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
x Thisventingmethodcanalsobemodifiedsothattheventingsystemrunshorizontallythroughthe
wallfromthestove,thentransitionstoverticalandterminatesabovetheroofline.Whenusingthis
modifiedversionofthisinstallationbecertaintocarefullyfollowtheventingsystem
manufacturer’sinstructionsdiligently.
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each
individual installation. Please follow all venting system requirements, maintain the required clearances to combustibles,
and follow all local codes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(
3”
)
tofourinch
(
4”
)
.
12
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
ApprovedVentingMethod3:ExistingChimneySystem
x Usinganexistingmasonryorfactorybuiltchimneyforventingistheonlyotheracceptablemethod
forventingthispelletunit.
x UseTypeLorTypePLventingpipeuntilenteringtheexisting
chimney.Usetheappropriatelysizedadapterwhen
transitioningfromthepelletventpipetothemasonryorfactory
builtthimbleandbecertainthattheadapterissealedtightlyto
boththepelletventingsystemandtheexistingchimney.
x Beforeusinganexistingchimney,becertainitisingood
condition(Achimneysweepinspectionishighlyrecommended).
Also,makesurethechimneymeetstheminimumstandards
listedinNFPA211(Achimneyprofessionalcanconfirmthisupon
inspection).
x Ifconnectingthisstovetoafactorybuiltchimney,itmay
ONLYbea6”flue,UL103HTventingsystem(ULCS629if
Canada).Connectiontoanyotherfactorybuiltchimneymay
resultinapoorlyoperatingordangerousstoveinstallation.
x Whenconnectingtoanexistingmasonrychimney,thecrosssectionalareaofthefluemustbe
considered.Achimneywithafluelargerthan6”round(28.27sq.in.)mayrequirereliningwithan
approvedpelletstovechimneyliningsystem.
x Useanappliancecollarwherethepelletventconnectstotheexhaustoutputofthepelletstove
andattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetalscrews.
x SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
x Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
x Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeach
individualinstallation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,
andfollowalllocalcodes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(
3”
)
tofourinch
(
4”
)
.
13
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
MobileHomeInstallation
x TheEngland’sStoveWorks,Inc.outsideairkitMUSTbeusedforinstallationofthisunitinamobile
home.Pleaseseethe“OutsideAir”sectiononpage15formoreinformationregardingoutsideair
connections.
x Theoutsideairinletmustbekeptclearofleaves,iceandotherdebris.Keepingtheoutsideairinlet
freeofrestrictioniscrucialtopreventingairstarvationandsmokespillage.
x ThepelletstoveMUSTbesecuredtothefloorofthemobilehomeusinglagboltsandtheholes
providedinthebottomofthebaseforthispurpose.Outdoorairedspaceheatersmustbe
attachedtothestructure.
x ThepelletstoveMUSTbegroundedwith#8solidcoppergroundingwire(orequivalent),
terminatedateachendwithanNECapprovedgroundeddevice.
x CarefullyfollowallclearanceslistedintheappropriatesectionofthismanualANDfollowthe
ventingmanufacturer’sminimumclearancerequirements.Similarly,becertaintheventingsystem
usedisapprovedformobilehomeuse.
x InstallationmustbeinaccordancewithManufacturersHome&SafetyStandard(HUD)CFR3280,
Part24aswellasanyapplicablelocalcodes.
x Usesiliconetocreateaneffectivevaporbarrieratthelocationwherethechimneyoroutsideair
ductingpassesthroughtotheexteriorofthestructure.
CAUTION
THESTRUCTURALINTEGRITYOFTHEMANUFACTUREDHOMEFLOOR,WALLANDCEILING/ROOFMUST
BEMAINTAINED.DONOTCUTTHROUGHFLOORJOISTS,WALLSTUDS,CEILINGTRUSSESORANY
OTHERSUPPORTINGMATERIALWHICHCOULDBEDETRIMENTALTOTHESTRUCTURALINTEGRITYOF
THEHOME.
WARNING:DONOTINSTALLINASLEEPINGROOM.
JoistShield/Firestop
MobileHomeApproved
TypeLorTypePLPellet
VentPipe
RoofFlashingandStorm
Collar
ChimneyCap/SparkArrestor
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(
3”
)
tofourinch
(
4”
)
.
14
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
VENTTERMINATIONCLEARANCES
A)MIN.4FTCLEARANCEBELOWORBESIDEANYDOORORWINDOWTHATOPENS.
B)MIN.1FTCLEARANCEABOVEANYDOORORWINDOWTHATOPENS.
C)MIN.2FTCLEARANCEFROMANYADJACENTBUILDING.
D)MIN.7FTCLEARANCEFROMANYGRADEWHENADJACENTTOPUBLICWALKWAYS.
E)MIN.2FTCLEARANCEABOVEANYGRASS,PLANTS,OROTHERCOMBUSTIBLEMATERIALS.
F)MIN.3FTCLEARANCEFROMAFORCEDAIRINTAKEOFANYAPPLIANCE.
G)MIN.2FTCLEARANCEBELOWEAVESOROVERHANG.
H)MIN.1FTCLEARANCEHORIZONTALLYFROMCOMBUSTIBLEWALL.
I)MUSTBEAMINIMUMOF36INCHESABOVETHEROOFAND24INCHESABOVETHEHIGHESTPOINT
OFTHEROOFWITHIN10FEET.

NotesonterminationofPelletVentPipefrom
NFPA 211(2006ed.)Section10.4Termination:10.4.5

(Seealso“INSTALLATION”sectionofmanualANDadditionalnotesabove):
- Not less than three (3) feet above any forced air inlet located within ten (10) feet.
- Not less than four (4) feet below, four (4) feet horizontally from, or one (1) foot above any door,
window or gravity air inlet into any building.
- Not less than two (2) feet from an adjacent building, and not less than seven (7) feet above
grade where located adjacent to public walkways.
The exhaust exit shall be arranged so that the flue gases are not directed so that it will affect people,
overheat combustible structures, or enter buildings. Forced draft systems and all parts of induced
draft systems under positive pressure during operation shall be installed gastight or to prevent
leakage of combustion products into a building. Through-the-wall vents shall not terminate over
public walkways, or where condensate or vapor could create hazards or a nuisance.
Be sure to follow local codes and all manufacturer’s instructions (including exhaust pipe).
Consult a professional installer and/or call Technical Support if you have any questions.
15
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
OUTSIDEAIRHOOKUP
x Theuseofoutsidecombustionairismandatoryonthispelletstove.
x Theoutsideairconnectionpipeprotrudesfromthelowerrearcenterofthestove;
usetheincludedoutsideairkittoattachyourstovetooutsidecombustionair.
Instructionsandallthepartsneededtomaketheoutsideairconnectiontoyour
pelletstoveareincludedwiththeoutsideairkit.
x Ifitisnotfeasibletousetheincludedoutsideairhookupkitinyourstove
installation,othermaterialsmaybeused,providedthefollowingrulesarefollowed:
x Thepipeusedforoutsideairhookupmustbemetal,withaminimum
thicknessof.0209in.(25gaugemildsteel)orgreaterandaninsidediameter
ofapproximately2.0in.
x Allpipejointsandconnectionsshouldbesealedwithpipeclampsorother
mechanicalmeans,toinsurealeakfreeoutsideairconnection.
x Longrunsofpipeandexcessiveelbowsforoutsideairshouldbeavoided.Due
tofrictionalresistanceinpipe,anyexcessiveoutsideairpipingcanresultin
poorstoveperformance.
x Ascreenorotherprotectiondevicemustbefittedovertheoutsideair
terminationpointtopreventrain,debrisandnuisanceanimalsfromentering
thepipingsystem.
x Increasetheoutsideairpipesizeto3.0in.diameterpipeiftheoutsideair
connectionismorethan6ft.inlength,morethantwo(2)elbowsareusedorif
thestoveisinstalledinabasement.
x Theoutsideairconnectionsystemshouldbeinspectedatleastannuallytobecertain
itisfreefromblockage.
Caution
NEVERdrawoutsidecombustionairfrom:
1.Wall,floororceilingcavity.
2.Enclosedspacesuchasanattic,garageorcrawlspace.
16
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
FLOORPROTECTION
x Thispelletstoverequiresanoncombustiblefloorprotectorifthestoveistobeinstalledona
combustiblefloor.Ifthefloorthestoveistobeinstalledonisalreadynoncombustible(i.e.a
concretefloorinabasement)andhasanRvalueequaltoorhigherthan.2,nofloorprotectionis
needed(althoughadecorativefloorprotectorcanstillbeusedforaestheticreasons).
x PrefabricatedfloorprotectorswhichareULlisted(ULCifCanada)orequivalentcanbepurchased
orafloorprotectorcanbebuiltfromstandardmaterials:twosheetsof.5”thickcementboard
coveredwithceramictilewouldbeasuitablefloorprotectorwhichmeetsthe.2Rvalue
requirement.
x Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduceheating
andcoolingcyclesonthefloorprotectorwhichcandamagetileandloosenmortarandgroutjoints.
AhearthrugisNOTanapprovedsubstituteforaproperhearthpad.
x FortheUS:Thefloorprotectormustextendatleast6in.(152.4mm)fromthefront&sidesand4
in.(101.6mm)fromtherear.
x ForCanada:Thefloorprotectormustextendatleast18.0in.(457.2mm)fromthefrontoftheunit,
8.0in.(203.2mm)fromthesidesoftheunitand4.0in.(101.6mm)fromtherear.
x InCanada,itisrequiredthatthenoncombustiblefloorprotectorisunderneathandextends2in.
(50.8mm.)oneithersideofanyhorizontalventingrunsAND/ORisdirectlyunderneathanyvertical
ventingpipe.
4”
(U.S.A.)
17
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
DAILYOPERATION
GettingStarted
x Checktoseethatthehopperiscleanandfreefromforeignmaterials.Besuretoconnectthisunittoa
workingoutlet;werecommendusingasurgeprotectortohelpprotecttheelectroniccomponentsfrom
damage.
x BEFOREyourfirstfire,dryrunyourunit(nopelletfuelinthehopper)fortwentyminutes;pressingthe“ON”
buttonwiththeunitpluggedinwillinitiatethedryrun.
x Oncethe“ON”buttonispressed,youshouldimmediatelyheartheexhaustblowerstartand
operatecontinuously.Afterafewseconds,theletters“SU”willappearinthetwodisplaywindows
ofthecontrolboard.
x Afteraboutthreetofiveminutes,lookfortheredglowoftheigniterintheigniterportoftheburn
pottobecertainitisoperatingnormally.
x Holdthehopperlidswitch(See“IllustratedPartsDiagram”pg.44)downwithyourfingerandcheck
toseethattheaugeristurning.Releasethehopperlidswitchandbecertainthattheaugerstops
turning.DONOTPUTYOURFINGERSINTHEHOPPERORNEARTHEROTATINGAUGER.
x Afterabouttwentyminutes,thecontrolboardshoulddisplay“E2”inthetwodisplaywindows(More
informationonErrorCodescanbefoundintheErrorCodesectionofthismanual).
x Atthispoint,thedryruniscompleteandyourpelletheatingapplianceisreadyfornormaloperation.
LightingaFire
x Inorderforthisstovetooperate,thehoppermustfirstbefilledwithpelletfuel.Liftthehopperlidusing
theflushmounthandleandpourthepelletfueldirectlyintothehopper.
WerecommendusingonlypelletsmanufacturedbyPFICertifiedfacilities,sincepelletsbearing
thePFIstampofapprovalwillbelowinashandmoisture,highinBTU’s,anduniforminsizeand
quality.
x Thispelletstovewillperformequallywellusingsoftwoodandhardwoodpellets,andalthoughtheashmay
differslightlyinappearanceortexture,bothtypesofpelletswillburncleanlyandefficientlyinthisstove.
x Thispelletstoveisequippedwithanautomaticpelletignitionsystem;theonlyuserinputrequiredtolight
thestoveisasimplepressofthe“On”button.
x Shortlyafterpressingthe“On”button,theletters“SU”willappearintheheatrangeandblowerspeed
windowsofthecontrolboard.Thisindicatesthestovehasenteredthestartupsequenceandisoperating
normally.
18
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
x Thefuelfeedrateandcombustionairduringstartupisdeterminedbythecontrolboard,sothestovemay
bestartedonanyheatrange.
x Afterapproximatelyfifteenminutes,thefireshouldbeburningbrightlyandthe“SU”should
disappearfromthecontrolboard.Atthispoint,thestovehasbegunnormaloperationandthe
displaywindowsonthecontrolboardwillremainempty,unlesstheHeatRangeorBlowerSpeedis
adjusted.
x Itisnormalfortheunittosmokeduringthefirstfire,aspaintsandoilscure.Thisshoulddissipate
withinthefirsthour.Openadoorand/orwindowduringthefirstfiretoventilatethearea.
DailyOperationNotes
x Onlyhighquality,¼”(.25in.)diameterwoodpellets,shouldbeusedinthisstove.Usinglowgrade
woodpelletswithhighashcontentORwoodpelletswithahighmoisturecontentcancausethe
burnpottofillwithashatamorerapidpaceandcancauseintervalsbetweenperiodic
maintenancetobecomesignificantlyshorter.Pleasereadthe“Maintenance”sectionofthis
manualthoroughlytounderstandhowfuelselectionaffectsstoveoperation,maintenanceand
cleaning.
x Variationintheflameheightisnormal;notallwoodpelletfuelisuniforminsize,whichcanaffect
thewaypelletsarefedintotheburnpot.Althoughtheflameheightmayincreaseanddecrease
duringoperation,thereisnolossofefficiency.
x Alwaysstorewoodpelletfuelinadrylocation;storingwoodpelletfuelinadrylocationensures
thefuelwillremainpelletizedandlowinmoisturecontent.Also,becertainthatallwoodpellet
fuelisstoredatasafedistancefromthepelletheater;storingfuelincloseproximitytothestove
canresultinafire.
Thispelletburningroomheaterisequippedwithaspeciallydesignedburnpotwhichcomes
preinstalledfromthefactory.Thisburnpotelevatestheburningpelletsanddeliversairatthe
preciselyrequiredlocations.Pelletsmustonlybeburnedinthefactoryburnpot;nomodifications
shouldbemadetothisburnpotandnoadditionalgratesorotherfireelevatorsshouldbeused.
CAUTION
NEVERUSEGASOLINE,GASOLINETYPELANTERNFUEL,KEROSENE,CHARCOALLIGHTERFLUID,ORSIMILAR
LIQUIDSTOSTARTOR“FRESHENUP”AFIREINTHISHEATER.KEEPALLSUCHLIQUIDSWELLAWAYFROMTHE
HEATERWHILEINUSE.ADDITIONALLY,NEVERAPPLYFIRESTARTERTOANYHOTSURFACEOREMBERSINTHE
STOVE.DONOTUSECHEMICALSORFLUIDSTOSTARTTHEFIRE.
DONOTBURNGARBAGEORFLAMMABLEFLUIDSSUCHASGASOLINE,NAPHTHAORENGINEOIL.
19
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
CONTROLBOARDSETTINGS
Thecontrolboardonthisstoveallowstheusertoadjusttheheatoutputandconvectionblowerspeed,
turntheunitonandoff,andtestcomponentsforfunction(moreondiagnosticmodelater).
x Thelowerbuttonsonthecontrolboard(LowFuelFeed,LowBurnAir,andAironTemp)arenot
meanttobeadjustedduringnormaloperationoftheunit.Thesebuttonsarefactorypresetand
shouldnotbeadjustedbytheuser.
x Toenergizetheunitandinitiateafire,pressthe“On”button.TheLEDabovethebuttonshould
turngreenandthecontrolboardshoulddisplay“SU”shortlyafterpressingthebutton.
x Toshuttheunitdown,pressthe“Off”button.TheLEDabovethebuttonshouldturnredandthe
boardshoulddisplay“Sd”shortlyafterpressingthebutton.Thisinitiatestheshutdownsequence,
andthestovewillremaininshutdownmodeuntilithascooleddown.
x Toincreasetheheatoutputofthestove,pressthe“Up”heatrangebutton.Thenumberinthe
heatrangedisplaywindowwillincrease,signifyingthatthecontrolboardisnowadjustingtheheat
outputtoyourdesiredlevel.Theblowerspeedwillincreasethesameamountastheheatrange,
becausethestoveisdesignedtooperatewiththeblowerspeedgreaterthanorequaltotheheat
range.Pressingthe“Down”arrowwilldecreasetheheatrangeandblowerspeed.
x Toincreasetheblowerspeedwithoutincreasingtheheatrange,presstheBlowerSpeed“Up”
arrowuntilthedesiredblowerspeedisshowninthedisplaywindow.Pressingthe“Down”arrow
willdecreasetheblowerspeed;however,thecontrolboardwillnotallowtheblowerspeedtobe
setlowerthantheheatrange
.
Caution
Thisunitismeanttooperateonlywiththeashpanandmainviewingdoorclosed.
Smokespillageandaninefficient,lazyburnwillresultfromattemptingtooperatethe
stovewitheitherdooropen.
Inaddition,usingfuelotherthanwoodpelletscancreateanunsafesituationandcan
alsogenerateexcesscarbonmonoxide.Carbonmonoxideisanodorless,colorlessgas
whichcanbedeadly.Besuretoburnonlywoodpellets.
Theuseofacarbonmonoxidedetectorisstronglyrecommended.
20
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
ERRORCODES
Errorcodes,or“ECodes,”arealphanumericcodesthatwillappearintheHeatRangeandBlower
SpeedwindowsoftheControlBoardiftheunitexperiencesanabnormalcondition.Errorcodesare
thecontrolboard’swayoftellingtheuserthatsomethingisn’toperatingcorrectlywithinthestove,
andthattheunitshouldbecarefullyinspectedbeforereigniting.Seethe“TroubleShootingGuide,”
page32,foradditionalinformationonerrorcodes.
E0
¾ Whenthisisdisplayedinthecontrolboardwindows(typicallywhenrestartingafteran“E
Code”shutdown),itmeanstherearecurrentlynoerrorsandthestovewillbeginnormal
operation.
E1
¾ Thiserrorcodeisnotusedonthisstove.Ifitisdisplayedinthecontrolboardwindows,
pleasecontactTechnicalSupportandtheywilldiagnosethecauseofthefalsecode.
E2
¾ Whenthiscodeisdisplayedinthecontrolboardwindowitindicatesafailuretolight.
Althoughthestovemayhaveignitedthepellets,thecontrolboarddidnotregisterahigh
enoughtemperaturetodeterminethefirewaslit.Ifafirewasignited,waitfortheunitto
cool,cleantheburnpotandrestarttheunit.
E3
¾ Thiserrorcodeindicatesthepresetmaximumallowableexhausttemperaturewas
exceeded.Commonlyreferredtoas“OverFiring,”theE3codemeanssomethinginthe
stoveiscausingtheexhaustgastobehotterthanexpected.
E4
¾ Thiscodeisdisplayedbasedonadropintheexhausttemperature.Thiscodemeansthe
fireor“proofofflame”hasbeenlost.Itusuallyresultsfromthehopperbeingempty.
Ifanerrorcodecontinuestodisplay,iftheerrorcodeseemsunexplainable,orifyou
haveanyotherquestionsabouterrorcodesandwhattheymean,pleasecontact
TechnicalSupportat(800)2456489.

HopperLidSafetySwitchThisunitisalsoequippedwithahopperlidsafetyswitch(Part#
ACHLSB)whichisdirectlyconnectedtotheaugermotor.Intheeventthehopperlidisleft
openwhilethestoveisinoperation,thehopperlidswitchwillpreventtheaugerfrom
turning.Thisistopreventbyproductsofcombustionfromenteringthehomethroughthe
openhopperlidandalsotosimplypreventoperationwiththehopperlidopen.Improper
hopperlidsafetyswitchoperationwillresultinanaugerthatwillnotturnandthereforea
stovethatwillnotburn.NEVERplaceyourhandoranyobjectneartheaugerwhilethestove
isconnectedtopower.
/