Summers Heat 55-SHPIPL Installation guide

Category
Fireplaces
Type
Installation guide
IMPERIALPELLETSTOVE


CAUTION
PLEASEREADTHISENTIREMANUALBEFOREINSTALLATIONANDUSEOFTHISPELLETFUELBURNING
APPLIANCE.KEEPCHILDREN,FURNITURE,ANDALLCOMBUSTIBLESAWAYFROMANYHEATINGAPPLIANCE.
SAFETYNOTICE
FAILURETOFOLLOWTHESEINSTRUCTIONSCANRESULTINPROPERTYDAMAGE,BODILYINJURYOREVEN
DEATH.FORYOURSAFETYANDPROTECTION,FOLLOWTHEINSTALLATIONINSTRUCTIONSOUTLINEDIN
THISMANUAL.CONTACTYOURLOCALBUILDINGORFIREOFFICIALSABOUTRESTRICTIONSAND
INSTALLATIONINSPECTIONREQUIREMENTS(INCLUDINGPERMITS)INYOURAREA.
ManufacturedBy:
England’sStoveWorks,Inc.
POBox206
Monroe,VA24574
9/20/2012
SAVETHESEINSTRUCTIONS
INSTALLATION&OPERATION
MANUAL
25IP/55SHPIP/55TRPIP
25IPS/55SHPIPS/55TRPIPS
2
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE
UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO
UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
IMPORTANT:IFYOUHAVEAPROBLEMWITHTHISUNIT,DONOTRETURNITTO
THEDEALER.CONTACTTECHNICALSUPPORT@18002456489
MobileHomeUse:
Thisfreestandingpelletunitisapprovedformobilehomeordoublewide
installationwiththeoutsidecombustionairhookup.Seethe“Installation”
sectionofthismanualfordetailspertainingtomobilehomeinstallations.Mobile
homeinstallationmustbeinaccordancewiththeManufacturedHomeandSafety
Standard(HUD),CFR3280,Part24.
WARNING:
USEOFOUTSIDECOMBUSTIONAIRISMANDATORYWITHTHISUNIT.
DONOTOPERATEWITHTHEHOPPEROPEN;LIDMUSTBESHUTANDTIGHTLY
LATCHEDDURINGOPERATION.
Note:England’sStoveWorksdoesnotrecommendusingapelletstoveasyour
onlysourceofheat.
Retain for your files
Model Number
Date of Purchase
Date of Manufacture
Serial Number
3
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE
UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO
UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
TABLEOFCONTENTS
Introduction
x Introduction.......................................4
Specifications
x HeatingSpecifications.......................5
x Dimensions........................................5
x EPACompliance.................................5
Installation
x InstallationOverview.........................6
x ClearancestoCombustibles..............7
x VentingIntroduction.........................8
x VentingGuidelines............................8
x AdditionalVentingInformation.........9
x ApprovedVentingMethods
x ThroughtheWall................10
x ThroughtheCeiling............11
x ExistingChimney................12
x MobileHomeInstallation................13
x VentTerminationClearances..........14
x OutsideAirHookup.........................15
x FloorProtection...............................16
DailyOperation
x GettingStarted................................17
x LightingaFire.............................1718
x ControlBoardSettings....................19
x ErrorCodes......................................20
x PowerFailure...................................21
x ThermostatInstallation...................22
x ThermostatOperation................2223
x OptionalAccessories.......................23
Maintenance
x Daily
x ImportantNotes.................24
x DailyAshRemoval.........2425
x CleaningtheBurnPot.........25
x Biweekly
x BaffleRemoval...................26
x Monthly
x ImportantNotes............2627
x ExhaustChamber...........2728
x VentingPipe.......................28
x Yearly
x ImportantNotes.................29
x ExhaustBlower...................30
x ConvectionBlower.............30
x CradleRemoval..................31
x HopperFines......................31
x CheckingGaskets...............31
TroubleshootingGuide
x Troubleshooting.........................3233
ReplacingComponents
x AugerMotor....................................34
x ConvectionBlower..........................35
x CombustionBlower.........................35
x VacuumSwitch................................36
x Igniter..............................................36
x Gaskets............................................37
x Glass................................................38
x ControlBoard..................................39
x WiringDiagram...............................40
x HopperLidLatches..........................41
x DoorLatch.......................................42
x Magnets..........................................42
x HopperLid.......................................42
x Fiberboard.......................................43
x Panels..............................................43
x Finish...............................................43
IllustratedPartsDetail
x ExplodedPartsDiagram..................44
x PartsList.....................................4546
OtherDetails
x AshPanLatches..........................46
Warranty
x SerialTagSample............................47
x WarrantyDetails........................4849
x ImportantNotice.............................50
x WarrantyReg.Form........................51
4
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INTRODUCTION
ThankyouforpurchasingthisfineproductfromEngland’sStoveWorks!
England’sStoveWorkswasstarted,andisstillownedby,afamilythat
believesstronglyina“DoItYourself”spirit;that’sonereasonyoufoundthis
productatyourfavorite“DoItYourself”store.
Weintentionallydesignandbuildourstovessothatanyhomeownercan
maintaintheirunitwithbasictools,andwe’realwaysmorethanhappyto
showyouhowtodothejobaseasilyandasinexpensivelyaspossible.
However,whileremainingsimple,ourstovesaredesignedtoperform
extremelyefficiently,helpingdelivermoreheat
fromlessfuel.
PleaselookatourvastHelpsectiononourwebsiteandcallourTechnical
SupportDepartmentat(800)2456489ifyouneedanyhelpwithyourunit.
Wearenearlyalwaysableto“walkyouthrough”anyinstallationissues,
repairs,problemsorotherquestionsthatyoumay
have.
Wishingyouyearsofefficient,qualityand“comfy”heating,
EVERYONEATENGLANDSSTOVEWORKS
PleaseNote
:Whileinformationobtainedfromourwebsiteandthroughour
TechnicalSupportlineisalwaysfreeofcharge,therewillbeaservicecharge
incurredwithany“onsite”repairsormaintenancethatwemayarrange.
Thismanualencompassesallversionsofthe25IP,includingthe55SHPIP,55SHPIPLand55TRPIP.Thisalso
appliestothestraightversionofthisunitwithmodelnumbers25IPS,55SHPIPSand55TRPIPS.However,for
simplicityofdescription,thestovewillbereferredtobythegeneric25IPdesignation.
5
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
SPECIFICATIONS
HeatingSpecifications
x HeatOutputRange**....................................................................14,108to35,023BTU/hr
x ApproximatePelletBurnRate**..........................................................0.945to2.346kg/hr
x MaximumBurnTime**..........................................................................................38hours
x ApproximateSquareFootageHeated***................................................upto2,200sq.ft.
x HopperCapacity...................................................................................................80pounds
Dimensions
 
EPAandSafetyComplianceSpecifications
x EPACompliance.......................................................................................................Certified
x ParticulateEmissions......................................................................................1.78grams/hr
x Efficiency*......................................................................................................................78%
x TestedTo..................UL148200,ASTME1509,ULC/ORDC1482M1990&ULCS62700
Notesforthisunit:Picturemaynotmatchyourunitifyouhavethestraightversion.Clearances
aretheminimumforthisunitandmayneedtobeincreasedinthereartohavepropervent
clearances.Followallventingmanufacturerclearancesandlocalcodes.
*Thisunitwasnottestedforefficiency;theefficiencyshownisadefaultvaluenormallyattainedbysimilar,certifiedpelletburningappliances.
**Heatoutput,burnrateandmaximumburntimeareheavilydependentonthetypeofpelletsburnedinthestove;assuch,thesenumbersmayvary.
***Themaximumheatingcapacityofthisunitcanvarygreatlybasedonclimate,constructionstyle,insulationandamyriadofotherfactors.Usethis
informationinconjunctionwithaBTUlosscalculationforyourhometodetermineifthisunitwillbesufficientforyourneeds.
6
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
InstallationOverview
Whenchoosingalocationforyournewstove,thereareamultitudeoffactors
thatshouldbetakenintoaccountbeforebeginningtheinstallation.
1. TrafficPatterns–Tohelppreventaccidents,thestoveshouldbeplacedina
locationwhereitisoutofthewayofnormaltravelthroughthehome.
2. HeatFlow–Whendecidingonalocationforthestove,considerthewayheat
movesthroughoutyourhome.Installthestovewhereyouneedtheheat;
basementinstallationsoftendonotallowsufficientheattoflowtotheupper
floorsandatopfloorinstallationwillnotallowanyheattoreachthefloors
below.Alwaysconsiderthatheatrisesandwilltakethepathofleast
resistancewhileitisstillhot.
3. ExhaustLocation–Outsidewallsaregenerallythebestplacetoinstallastove,
sincetheyalloweasyexhaustandintakeairinstallation(usingourDuraVent
AC3000Kit,AC33000ifCanada).Ifthereisnotafeasiblewaytoinstallthe
stoveonanoutsidewall,therearemethodsforventingthestoveupthrough
theroof,buttheytendtobemorecostlybecausetheyinvolvetheuseofmore
pelletventpipeandcanoftenmakeoutsideairinstallationmoredifficult.
4. WallConstruction–Locatingthestovesothattheexhaustsystemcanpass
betweenstudswillsimplifytheinstallationandeliminatetheneedtoreframe
anysectionsofthewalltoaccommodatethewallthimble.
WARNING
x Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityofthisoranyother
appliance.
x DoNotOverfire–Ifanyexternalpartstartstoglow,youareoverfiring.Reducefeedrate.Overfiringwill
voidyourwarranty.
x Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymayresultinahouse
fire.
x Testedandapprovedforwoodpelletsonly.Burninganyotherfuelwillvoidyourwarranty.
7
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
ClearancestoCombustibles

UnittoSide
Wall(A)
UnittoRear
Wall(B)
UnittoCorner
(C)
UnitTopto
Ceiling
Min.Ceiling
Height
6in. 6in. 3in. 9in. 60in.
152.4mm 152.4mm 76.2mm 228.6mm 1524mm
Alcoveinstallationnotrecommendedforthisunit
CAUTION
x UnitcanbeveryHOTwhileinoperation.Keepchildrenaway.
x Supervisechildreninthesameroomasthisappliance.
x Alertchildrenandadultstothehazardsofhightemperatures.
x DoNOToperatewithprotectivebarriersopenorremoved.
x Keepclothing,furniture,draperiesandothercombustiblesaway.
x InstallationMUSTcomplywithlocal,regional,stateandnationalcodesandregulations.
x Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdictionaboutrestrictions,
installationinspection,andpermits.
DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM
8
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
VentingIntroduction
Thispelletstoveoperatesonanegativedraftsystem,whichpullscombustionairthroughthe
burnpotandpushestheexhaustairthroughtheventpipeandoutofthebuilding.Thisunitmustbe
installedinaccordancewiththefollowingdetaileddescriptionsofventingtechniques;notinstallingthe
stoveinaccordancewiththedetailslistedherecanresultinpoorstoveperformance,property
damage,bodilyinjuryordeath.England’sStoveWorksisnotresponsibleforanydamageincurreddue
toapoororunsafeinstallation.
Ifquestionsarisepertainingtothesafeinstallationofthestove,ourTechnicalSupportline
(8002456489)isavailable.Contactyourlocalcodeofficialtobecertainyourinstallationmeetslocal
andnationalfirecodesandifyou’reuncertainabouthowtosafelyinstallthestove,westrongly
recommendcontactingalocalNFIcertifiedinstallertoperformtheinstallation.
VentingGuidelines
x ALWAYSinstallventpipeinstrictadherencewiththeinstructionsandclearancesincludedwith
yourventingsystem.
x DONOTconnectthispelletstovetoachimneyfluewhichalsoservesanotherappliance.
x DONOTinstallafluepipedamperoranyotherrestrictivedeviceintheexhaustventingsystem
ofthisunit.
x USEanapprovedwallthimblewhenpassingthroughawallandaceilingsupport/firestopwhen
passingthroughaceiling.
x ONLYuse3.0”or4.0”TypeLorTypePLpipeapprovedforpelletstoveventing;DONOTuse
galvanizedorBVentpipe.
x SEALeachjointofpelletventwithhightemperaturesilicone(Part#ACRTV3)topreventsmoke
spillageintothehome.
x AVOIDexcessivehorizontalrunsandelbows,asbothwillreducethedraftoftheventingsystem
andwillresultinpoorstoveperformance.
x INCLUDEasmuchverticalpipeaspossibletopreventsmokefromtheunitfromenteringyour
homeintheeventofapoweroutage.
x INSPECTyourventingsystemoften,tobecertainitisclearofflyashandotherrestrictions.
x CLEANtheventingsystemasdetailedinthemaintenancesectionofthismanual.
WARNING
x INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
x HOT!Donottouch!Severeburnsorclothingignitionmayresult.
x Glassandothersurfacesarehotduringoperation.
x Donotattempttotouchoropenthefrontorsidepanelsduringoperation.Thiscouldresultinsevere
burnsorinjury.
9
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
AdditionalVentingInformation
x Donotmixandmatchcomponentsfromdifferentpipemanufacturerswhenassemblingyour
ventingsystem(i.e.DoNOTuseventingpipefromonemanufacturerandathimblefrom
another).
x Werequireaminimumverticalriseof36in.(3ft.)ofpipetocreatenaturaldraftinthesystem,
whichhelpsevacuatesmokefromthestoveintheeventofapowerfailureorcombustion
blowerfailure.
x Ventingsystems15.0ft.orshortermaybecomposedentirelyof3.0in.pelletpipe;toreduce
frictionallosses,ventingsystemslongerthan15.0ft.shouldbecomposedof4.0in.pelletpipe.
x Donotterminatetheventingsystemdirectlybeneathanycombustiblestructuresuchasa
porchordeck.
x FollowNFPA211ruleslistedbelowforventingsystemterminationlocationrelativetowindows
andotheropeningsinthedwelling.
o NFPA211(2006ed.)Section10.4Termination:10.4.5
(1)Theexitterminalofamechanicaldraftsystemotherthandirectventappliances
(sealedcombustionsystemappliances)shallbelocatedinaccordancewiththe
following:
(a)Notlessthan3ft.(.91m)aboveanyforcedairinletlocatedwithin10ft.
(3.0m).
(b)Notlessthan4ft.(1.2m)below,4ft.(1.2m)horizontallyfromor1ft.(305
mm)aboveanydoor,windoworgravityairinletintoanybuilding.
(c)Notlessthan2ft.(0.61m)fromanadjacentbuildingandnotlessthan7ft.
(2.1m)abovegradewhenlocatedadjacenttopublicwalkways.
x Distancebetweentheterminationopeningandgradeshouldbeaminimumof2ft.(24in.)
contingentonthegradesurfacebelowthetermination.Whendeterminingthetermination
heightabovegrade,considersnowdriftlinesandcombustiblessuchasgrassorleaf
accumulation.Inareaswheresignificantsnowfallispossible,theterminationheightmustbe
sufficientlyhightokeeptheterminationfreeofsnowaccumulation.
x Donotusemakeshiftcompromisesduringinstallationorinstallanycomponentoftheunitor
ventingsysteminsuchamannerthatcouldresultinahazardousinstallation.
x Achimneyconnector
shallnotpassthroughanatticorroofspace,closetorsimilarconcealed
space,orafloor,orceiling.
x Wherepassagethroughawallorpartitionofcombustiblematerialisdesired,theinstallation
shallconformtoCAN/CSAB365.
WARNING:
VentingsystemsurfacesgetHOT,andcancauseburnsiftouched.Noncombustibleshielding
orguardsmayberequired.
10
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
ApprovedVentingMethod1:ThroughtheWall
x Generallythesimplestinstallationmethod,ventingthrough
thewallusingourAC3000kit,AC33000ifCanada(orsimilar
ventingsystem)isalsothepreferredventingmethod.It
minimizeshorizontalpipe,allowsthestovetobeinstalledclose
tothewallandkeepsthecleanoutteeontheoutsideofthe
house,foreaseofcleaning.
x Wheninstallinganyventingsystem,TypeLorTypePLpipe
mustbeusedandallclearancestocombustibles(listedbythe
pipemanufacturer)mustbestrictlyadheredto.
x Usethepipemanufacturer’sapprovedthimbleforpassing
throughacombustiblewall,andmaintainatleasttheminimum
clearancestocombustibles.
x Useanappliancecollarwherethepelletventconnectsto
theexhaustoutputofthepelletstoveandattachtheappliance
collartotheexhaustbloweroutputusingthreesheetmetalscrews.
x Securethepelletventtotheoutsideofthehouseusingawallstrapjustbelowthe90degree
elbow.
x SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificventingsystemmanufacturer’sinstructionsbeforedoingso).
x Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
x Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
Thisinstallationtypecanbemodifiedforbasement(Basementinstallationsshouldalwaysbe
performedbyaprofessionalinstaller)orotherinstallationswhereintheteeandverticalsectionofthe
pipewouldbeinsidethehomeandtheventingsystemwouldsimplypasshorizontallythroughthe
thimbleandthenterminate.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeach
individualinstallation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,
andfollowalllocalcodes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(
3”
)
tofourinch
(
4”
)
.
11
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
ApprovedVentingMethod2:ThroughtheCeiling
x Ventingthroughtheceiling/roofmaybetheonlyfeasible
ventingoptioninsomecasesandisafactoryrecommended
installation.
x Wheninstallinganyventingsystem,TypeLorTypePLpipe
mustbeusedandallclearancestocombustibleslistedbythe
pipemanufacturermustbestrictlyadheredto.
x Usethepipemanufacturer’sapprovedceilingsupportfor
passingthroughacombustibleceiling,aswellastherequired
firestops,radiationshields,flashingandstormcollar.
x Becertaintofollowthemanufacturer’srequiredheightof
terminationabovetheroofline,andmaintainatleastthe
minimumclearancestocombustibles.
x Useanappliancecollarwherethepelletventconnectsto
theexhaustoutputofthepelletstoveandattachtheappliance
collartotheexhaustbloweroutputusingthreesheetmetal
screws.
x SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
x Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
x Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
x Thisventingmethodcanalsobemodifiedsothattheventingsystemrunshorizontallythroughthe
wallfromthestove,thentransitionstoverticalandterminatesabovetheroofline.Whenusingthis
modifiedversionofthisinstallationbecertaintocarefullyfollowtheventingsystem
manufacturer’sinstructionsdiligently.
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each
individual installation. Please follow all venting system requirements, maintain the required clearances to combustibles,
and follow all local codes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(
3”
)
tofourinch
(
4”
)
.
12
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
ApprovedVentingMethod3:ExistingChimneySystem
x Usinganexistingmasonryorfactorybuiltchimneyforventingistheonlyotheracceptablemethod
forventingthispelletunit.
x UseTypeLorTypePLventingpipeuntilenteringtheexisting
chimney.Usetheappropriatelysizedadapterwhen
transitioningfromthepelletventpipetothemasonryorfactory
builtthimbleandbecertainthattheadapterissealedtightlyto
boththepelletventingsystemandtheexistingchimney.
x Beforeusinganexistingchimney,becertainitisingood
condition(Achimneysweepinspectionishighlyrecommended).
Also,makesurethechimneymeetstheminimumstandards
listedinNFPA211(Achimneyprofessionalcanconfirmthisupon
inspection).
x Ifconnectingthisstovetoafactorybuiltchimney,itmay
ONLYbea6”flue,UL103HTventingsystem(ULCS629if
Canada).Connectiontoanyotherfactorybuiltchimneymay
resultinapoorlyoperatingordangerousstoveinstallation.
x Whenconnectingtoanexistingmasonrychimney,thecrosssectionalareaofthefluemustbe
considered.Achimneywithafluelargerthan6”round(28.27sq.in.)mayrequirereliningwithan
approvedpelletstovechimneyliningsystem.
x Useanappliancecollarwherethepelletventconnectstotheexhaustoutputofthepelletstove
andattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetalscrews.
x SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
x Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
x Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeach
individualinstallation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,
andfollowalllocalcodes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(
3”
)
tofourinch
(
4”
)
.
13
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
MobileHomeInstallation
x TheEngland’sStoveWorks,Inc.outsideairkitMUSTbeusedforinstallationofthisunitinamobile
home.Pleaseseethe“OutsideAir”sectiononpage15formoreinformationregardingoutsideair
connections.
x Theoutsideairinletmustbekeptclearofleaves,iceandotherdebris.Keepingtheoutsideairinlet
freeofrestrictioniscrucialtopreventingairstarvationandsmokespillage.
x ThepelletstoveMUSTbesecuredtothefloorofthemobilehomeusinglagboltsandtheholes
providedinthebottomofthebaseforthispurpose.Outdoorairedspaceheatersmustbe
attachedtothestructure.
x ThepelletstoveMUSTbegroundedwith#8solidcoppergroundingwire(orequivalent),
terminatedateachendwithanNECapprovedgroundeddevice.
x CarefullyfollowallclearanceslistedintheappropriatesectionofthismanualANDfollowthe
ventingmanufacturer’sminimumclearancerequirements.Similarly,becertaintheventingsystem
usedisapprovedformobilehomeuse.
x InstallationmustbeinaccordancewithManufacturersHome&SafetyStandard(HUD)CFR3280,
Part24aswellasanyapplicablelocalcodes.
x Usesiliconetocreateaneffectivevaporbarrieratthelocationwherethechimneyoroutsideair
ductingpassesthroughtotheexteriorofthestructure.
CAUTION
THESTRUCTURALINTEGRITYOFTHEMANUFACTUREDHOMEFLOOR,WALLANDCEILING/ROOFMUST
BEMAINTAINED.DONOTCUTTHROUGHFLOORJOISTS,WALLSTUDS,CEILINGTRUSSESORANY
OTHERSUPPORTINGMATERIALWHICHCOULDBEDETRIMENTALTOTHESTRUCTURALINTEGRITYOF
THEHOME.
WARNING:DONOTINSTALLINASLEEPINGROOM.
JoistShield/Firestop
MobileHomeApproved
TypeLorTypePLPellet
VentPipe
RoofFlashingandStorm
Collar
ChimneyCap/SparkArrestor
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(
3”
)
tofourinch
(
4”
)
.
14
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
VENTTERMINATIONCLEARANCES
A)MIN.4FTCLEARANCEBELOWORBESIDEANYDOORORWINDOWTHATOPENS.
B)MIN.1FTCLEARANCEABOVEANYDOORORWINDOWTHATOPENS.
C)MIN.2FTCLEARANCEFROMANYADJACENTBUILDING.
D)MIN.7FTCLEARANCEFROMANYGRADEWHENADJACENTTOPUBLICWALKWAYS.
E)MIN.2FTCLEARANCEABOVEANYGRASS,PLANTS,OROTHERCOMBUSTIBLEMATERIALS.
F)MIN.3FTCLEARANCEFROMAFORCEDAIRINTAKEOFANYAPPLIANCE.
G)MIN.2FTCLEARANCEBELOWEAVESOROVERHANG.
H)MIN.1FTCLEARANCEHORIZONTALLYFROMCOMBUSTIBLEWALL.
I)MUSTBEAMINIMUMOF36INCHESABOVETHEROOFAND24INCHESABOVETHEHIGHESTPOINT
OFTHEROOFWITHIN10FEET.

NotesonterminationofPelletVentPipefrom
NFPA 211(2006ed.)Section10.4Termination:10.4.5

(Seealso“INSTALLATION”sectionofmanualANDadditionalnotesabove):
- Not less than three (3) feet above any forced air inlet located within ten (10) feet.
- Not less than four (4) feet below, four (4) feet horizontally from, or one (1) foot above any door,
window or gravity air inlet into any building.
- Not less than two (2) feet from an adjacent building, and not less than seven (7) feet above
grade where located adjacent to public walkways.
The exhaust exit shall be arranged so that the flue gases are not directed so that it will affect people,
overheat combustible structures, or enter buildings. Forced draft systems and all parts of induced
draft systems under positive pressure during operation shall be installed gastight or to prevent
leakage of combustion products into a building. Through-the-wall vents shall not terminate over
public walkways, or where condensate or vapor could create hazards or a nuisance.
Be sure to follow local codes and all manufacturer’s instructions (including exhaust pipe).
Consult a professional installer and/or call Technical Support if you have any questions.
15
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
OUTSIDEAIRHOOKUP
x Theuseofoutsidecombustionairismandatoryonthispelletstove.
x Theoutsideairconnectionpipeprotrudesfromthelowerrearcenterofthestove;
usetheincludedoutsideairkittoattachyourstovetooutsidecombustionair.
Instructionsandallthepartsneededtomaketheoutsideairconnectiontoyour
pelletstoveareincludedwiththeoutsideairkit.
x Ifitisnotfeasibletousetheincludedoutsideairhookupkitinyourstove
installation,othermaterialsmaybeused,providedthefollowingrulesarefollowed:
x Thepipeusedforoutsideairhookupmustbemetal,withaminimum
thicknessof.0209in.(25gaugemildsteel)orgreaterandaninsidediameter
ofapproximately2.0in.
x Allpipejointsandconnectionsshouldbesealedwithpipeclampsorother
mechanicalmeans,toinsurealeakfreeoutsideairconnection.
x Long
runsofpipeandexcessiveelbowsforoutsideairshouldbeavoided.Due
tofrictionalresistanceinpipe,anyexcessiveoutsideairpipingcanresultin
poorstoveperformance.
x Ascreenorotherprotectiondevicemustbefittedovertheoutsideair
terminationpointtopreventrain,debrisandnuisanceanimalsfromentering
thepipingsystem.
x Increasetheoutsideairpipesizeto3.0in.diameterpipeiftheoutsideair
connectionismorethan6ft.inlength,morethantwo(2)elbowsareusedorif
thestoveisinstalledinabasement.
x Theoutsideair
connectionsystemshouldbeinspectedatleastannuallytobecertain
itisfreefromblockage.
Caution
NEVERdrawoutsidecombustionairfrom:
1.Wall,floororceilingcavity.
2.Enclosedspacesuchasanattic,garageorcrawlspace.
16
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
FLOORPROTECTION
x Thispelletstoverequiresanoncombustiblefloorprotectorifthestoveistobeinstalledona
combustiblefloor.Ifthefloorthestoveistobeinstalledonisalreadynoncombustible(i.e.a
concretefloorinabasement)andhasanRvalueequaltoorhigherthan.2,nofloorprotectionis
needed(althoughadecorativefloorprotectorcanstillbeusedforaestheticreasons).
x PrefabricatedfloorprotectorswhichareULlisted(ULCifCanada)orequivalentcanbepurchased
orafloorprotectorcanbebuiltfromstandardmaterials:twosheetsof.5”thickcementboard
coveredwithceramictilewouldbeasuitablefloorprotectorwhichmeetsthe.2Rvalue
requirement.
x Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduceheating
andcoolingcyclesonthefloorprotectorwhichcandamagetileandloosenmortarandgroutjoints.
AhearthrugisNOTanapprovedsubstituteforaproperhearthpad.
x FortheUS:Thefloorprotectormustextendatleast6in.(152.4mm)fromthefront&sidesand4
in.(101.6mm)fromtherear.
x ForCanada:Thefloorprotectormustextendatleast18.0in.(457.2mm)fromthefrontoftheunit,
8.0in.(203.2mm)fromthesidesoftheunitand4.0in.(101.6mm)fromtherear.
x InCanada,itisrequiredthatthenoncombustiblefloorprotectorisunderneathandextends2in.
(50.8mm.)oneithersideofanyhorizontalventingrunsAND/ORisdirectlyunderneathanyvertical
ventingpipe.
4”
(U.S.A.)
17
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
DAILYOPERATION
GettingStarted
x Checktoseethatthehopperiscleanandfreefromforeignmaterials.Besuretoconnectthisunittoa
workingoutlet;werecommendusingasurgeprotectortohelpprotecttheelectroniccomponentsfrom
damage.
x BEFOREyourfirstfire,dryrunyourunit(nopelletfuelinthehopper)fortwentyminutes;pressingthe“ON”
buttonwiththeunitpluggedinwillinitiatethedryrun.
x Oncethe“ON”buttonispressed,youshouldimmediatelyheartheexhaustblowerstartand
operatecontinuously.Afterafewseconds,theletters“SU”willappearinthetwodisplaywindows
ofthecontrolboard.
x Afteraboutthreetofiveminutes,lookfortheredglowoftheigniterintheigniterportoftheburn
pottobecertainitisoperatingnormally.
x Holdthehopperlidswitch(See“IllustratedPartsDiagram”pg.44)downwithyourfingerandcheck
toseethattheaugeristurning.Releasethehopperlidswitchandbecertainthattheaugerstops
turning.DONOTPUTYOURFINGERSINTHEHOPPERORNEARTHEROTATINGAUGER.
x Afterabouttwentyminutes,thecontrolboardshoulddisplay“E2”inthetwodisplaywindows(More
informationonErrorCodescanbefoundintheErrorCodesectionofthismanual).
x Atthispoint,thedryruniscompleteandyourpelletheatingapplianceisreadyfornormaloperation.
LightingaFire
x Inorderforthisstovetooperate,thehoppermustfirstbefilledwithpelletfuel.Liftthehopperlidusing
theflushmounthandleandpourthepelletfueldirectlyintothehopper.
WerecommendusingonlypelletsmanufacturedbyPFICertifiedfacilities,sincepelletsbearing
thePFIstampofapprovalwillbelowinashandmoisture,highinBTU’s,anduniforminsizeand
quality.
x Thispelletstovewillperformequallywellusingsoftwoodandhardwoodpellets,andalthoughtheashmay
differslightlyinappearanceortexture,bothtypesofpelletswillburncleanlyandefficientlyinthisstove.
x Thispelletstoveisequippedwithanautomaticpelletignitionsystem;theonlyuserinputrequiredtolight
thestoveisasimplepressofthe“On”button.
x Shortlyafterpressingthe“On”button,theletters“SU”willappearintheheatrangeandblowerspeed
windowsofthecontrolboard.Thisindicatesthestovehasenteredthestartupsequenceandisoperating
normally.
18
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
x Thefuelfeedrateandcombustionairduringstartupisdeterminedbythecontrolboard,sothestovemay
bestartedonanyheatrange.
x Afterapproximatelyfifteenminutes,thefireshouldbeburningbrightlyandthe“SU”should
disappearfromthecontrolboard.Atthispoint,thestovehasbegunnormaloperationandthe
displaywindowsonthecontrolboardwillremainempty,unlesstheHeatRangeorBlowerSpeedis
adjusted.
x Itisnormalfortheunittosmokeduringthefirstfire,aspaintsandoilscure.Thisshoulddissipate
withinthefirsthour.Openadoorand/orwindowduringthefirstfiretoventilatethearea.
DailyOperationNotes
x Onlyhighquality,¼”(.25in.)diameterwoodpellets,shouldbeusedinthisstove.Usinglowgrade
woodpelletswithhighashcontentORwoodpelletswithahighmoisturecontentcancausethe
burnpottofillwithashatamorerapidpaceandcancauseintervalsbetweenperiodic
maintenancetobecomesignificantlyshorter.Pleasereadthe“Maintenance”sectionofthis
manualthoroughlytounderstandhowfuelselectionaffectsstoveoperation,maintenanceand
cleaning.
x Variationintheflameheightisnormal;notallwoodpelletfuelisuniforminsize,whichcanaffect
thewaypelletsarefedintotheburnpot.Althoughtheflameheightmayincreaseanddecrease
duringoperation,thereisnolossofefficiency.
x Alwaysstorewoodpelletfuelinadrylocation;storingwoodpelletfuelinadrylocationensures
thefuelwillremainpelletizedandlowinmoisturecontent.Also,becertainthatallwoodpellet
fuelisstoredatasafedistancefromthepelletheater;storingfuelincloseproximitytothestove
canresultinafire.
Thispelletburningroomheaterisequippedwithaspeciallydesignedburnpotwhichcomes
preinstalledfromthefactory.Thisburnpotelevatestheburningpelletsanddeliversairatthe
preciselyrequiredlocations.Pelletsmustonlybeburnedinthefactoryburnpot;nomodifications
shouldbemadetothisburnpotandnoadditionalgratesorotherfireelevatorsshouldbeused.
CAUTION
NEVERUSEGASOLINE,GASOLINETYPELANTERNFUEL,KEROSENE,CHARCOALLIGHTERFLUID,ORSIMILAR
LIQUIDSTOSTARTOR“FRESHENUP”AFIREINTHISHEATER.KEEPALLSUCHLIQUIDSWELLAWAYFROMTHE
HEATERWHILEINUSE.ADDITIONALLY,NEVERAPPLYFIRESTARTERTOANYHOTSURFACEOREMBERSINTHE
STOVE.DONOTUSECHEMICALSORFLUIDSTOSTARTTHEFIRE.
DONOTBURNGARBAGEORFLAMMABLEFLUIDSSUCHASGASOLINE,NAPHTHAORENGINEOIL.
19
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
CONTROLBOARDSETTINGS
Thecontrolboardonthisstoveallowstheusertoadjusttheheatoutputandconvectionblowerspeed,
turntheunitonandoff,andtestcomponentsforfunction(moreondiagnosticmodelater).
x Thelowerbuttonsonthecontrolboard(LowFuelFeed,LowBurnAir,andAironTemp)arenot
meanttobeadjustedduringnormaloperationoftheunit.Thesebuttonsarefactorypresetand
shouldnotbeadjustedbytheuser.
x Toenergizetheunitandinitiateafire,pressthe“On”button.TheLEDabovethebuttonshould
turngreenandthecontrolboardshoulddisplay“SU”shortlyafterpressingthebutton.
x Toshuttheunitdown,pressthe“Off”button.TheLEDabovethebuttonshouldturnredandthe
boardshoulddisplay“Sd”shortlyafterpressingthebutton.Thisinitiatestheshutdownsequence,
andthestovewillremaininshutdownmodeuntilithascooleddown.
x Toincreasetheheatoutputofthestove,pressthe“Up”heatrangebutton.Thenumberinthe
heatrangedisplaywindowwillincrease,signifyingthatthecontrolboardisnowadjustingtheheat
outputtoyourdesiredlevel.Theblowerspeedwillincreasethesameamountastheheatrange,
becausethestoveisdesignedtooperatewiththeblowerspeedgreaterthanorequaltotheheat
range.Pressingthe“Down”arrowwilldecreasetheheatrangeandblowerspeed.
x Toincreasetheblowerspeedwithoutincreasingtheheatrange,presstheBlowerSpeed“Up”
arrowuntilthedesiredblowerspeedisshowninthedisplaywindow.Pressingthe“Down”arrow
willdecreasetheblowerspeed;however,thecontrolboardwillnotallowtheblowerspeedtobe
setlowerthantheheatrange
.
Caution
Thisunitismeanttooperateonlywiththeashpanandmainviewingdoorclosed.
Smokespillageandaninefficient,lazyburnwillresultfromattemptingtooperatethe
stovewitheitherdooropen.
Inaddition,usingfuelotherthanwoodpelletscancreateanunsafesituationandcan
alsogenerateexcesscarbonmonoxide.Carbonmonoxideisanodorless,colorlessgas
whichcanbedeadly.Besuretoburnonlywoodpellets.
Theuseofacarbonmonoxidedetectorisstronglyrecommended.
20
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
ERRORCODES
Errorcodes,or“ECodes,”arealphanumericcodesthatwillappearintheHeatRangeandBlower
SpeedwindowsoftheControlBoardiftheunitexperiencesanabnormalcondition.Errorcodesare
thecontrolboard’swayoftellingtheuserthatsomethingisn’toperatingcorrectlywithinthestove,
andthattheunitshouldbecarefullyinspectedbeforereigniting.Seethe“TroubleShootingGuide,”
page32,foradditionalinformationonerrorcodes.
E0
¾ Whenthisisdisplayedinthecontrolboardwindows(typicallywhenrestartingafteran“E
Code”shutdown),itmeanstherearecurrentlynoerrorsandthestovewillbeginnormal
operation.
E1
¾ Thiserrorcodeisnotusedonthisstove.Ifitisdisplayedinthecontrolboardwindows,
pleasecontactTechnicalSupportandtheywilldiagnosethecauseofthefalsecode.
E2
¾ Whenthiscodeisdisplayedinthecontrolboardwindowitindicatesafailuretolight.
Althoughthestovemayhaveignitedthepellets,thecontrolboarddidnotregisterahigh
enoughtemperaturetodeterminethefirewaslit.Ifafirewasignited,waitfortheunitto
cool,cleantheburnpotandrestarttheunit.
E3
¾ Thiserrorcodeindicatesthepresetmaximumallowableexhausttemperaturewas
exceeded.Commonlyreferredtoas“OverFiring,”theE3codemeanssomethinginthe
stoveiscausingtheexhaustgastobehotterthanexpected.
E4
¾ Thiscodeisdisplayedbasedonadropintheexhausttemperature.Thiscodemeansthe
fireor“proofofflame”hasbeenlost.Itusuallyresultsfromthehopperbeingempty.
Ifanerrorcodecontinuestodisplay,iftheerrorcodeseemsunexplainable,orifyou
haveanyotherquestionsabouterrorcodesandwhattheymean,pleasecontact
TechnicalSupportat(800)2456489.

HopperLidSafetySwitchThisunitisalsoequippedwithahopperlidsafetyswitch(Part#
ACHLSB)whichisdirectlyconnectedtotheaugermotor.Intheeventthehopperlidisleft
openwhilethestoveisinoperation,thehopperlidswitchwillpreventtheaugerfrom
turning.Thisistopreventbyproductsofcombustionfromenteringthehomethroughthe
openhopperlidandalsotosimplypreventoperationwiththehopperlidopen.Improper
hopperlidsafetyswitchoperationwillresultinanaugerthatwillnotturnandthereforea
stovethatwillnotburn.NEVERplaceyourhandoranyobjectneartheaugerwhilethestove
isconnectedtopower.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51

Summers Heat 55-SHPIPL Installation guide

Category
Fireplaces
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI