  • Hello! I am an AI chatbot trained to assist you with the Englander 25-PAH Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
PELLETAUXILIARYHEATER
INSTALLATION&OPERATIONMANUAL
25PAH/55SHPAH/55TRPAH


REV.5/2015
CAUTION
Pleasereadthisentiremanualbeforeinstallationanduseofthispelletfuel
burningappliance.Keepchildren,furniture,fixturesandallcombustiblesaway
fromanyheatingappliance.
SAFETYNOTICE
Failuretofollowtheseinstructionscanresultinpropertydamage,bodilyinjury
orevendeath.Foryoursafetyandprotection,followtheinstallation
instructionsoutlinedinthismanual.Contactyourlocalbuildingorfireofficials
aboutrestrictionsandinstallationinspectionrequirements(includingpermits)
inyourarea.
SAVETHESEINSTRUCTIO NS
ManufacturedBy:
England’sStoveWorks,Inc.
POBox206
Monroe
,
VA24574
2
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
WARNING:
Useofoutsidecombustionairismandatorywiththisunit.
Donotoperatewiththehopperopen;lidmustbeshut
andtightlylatchedduringoperation.
Retainforyourfiles
ModelNumber________________________
DateofPurchase_______________________
DateofManufacture____________________
SerialNumber_________________________
*Thisinformationcanbefoundonthesafetytagattachedtotheundersideofthe
hopperlid.Havethisinformationonhandifyouphone thefactoryoryourdealer
regardingthisproduct.
IMPORTANT:IFYOUHAVEAPROBLEMWITHTHISUNIT,DO
NOTRETURNITTOTHEDEALER.CONTACTTECHNICAL
SUPPORT@18002456489
Note:England’sStoveWorksdoesnotrecommendusinga
pelletstoveasyouronlysourceofheat.
MobileHomeUse:
Thisfreestandingpelletunitisapprovedformobilehomeor
doublewideinstallationwiththeoutsidecombustionairhook
up.Seethe“Installation”sectionofthismanualfordetails
pertainingtomobilehomeinstallations.Mobilehome
installationmustbeinaccordancewiththeManufactured
HomeandSafet
y
Standard
(
HUD
)
,CFR3280,Part24.
3
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
TABLEOFCONTENTS
Introduction
Introduction.................................4
Specifications
HeatingSpecifications..................5
Dimensions...................................5
EPACompliance...........................5
Installation
InstallationOverview...................6
ClearancestoCombustibles.........7
VentingIntroduction....................8
VentingGuidelines.......................8
AdditionalVentingInformation...9
VentTerminationClearances....10
ApprovedVentingMethods
o ThroughtheWall...........11
o ThroughtheCeiling........12
o ExistingChimney............13
MobileHomeInstallation..........14
OutsideAirHookUp..................15
FloorProtection.........................16
DailyOperation
GettingStarted...........................17
LightingaFire........................1718
ControlBoardSettings...............19
ErrorCodes................................20
PowerFailure.............................21
ThermostatInstallation..............22
ThermostatOperation...............23
OptionalAccessories..................23
Maintenance
Daily
o ImportantNotes.............24
o DailyAshRemoval.....2425
o CleaningtheBurnpot.....25
Monthly
o ImportantNotes.............26
o ExhaustChamber......2627
o VentingPipe...................27
Yearly
o ImportantNotes.............28
o ExhaustBlower..............29
o ConvectionBlower.........
30
o HopperFines..................30
o CheckingGaskets...........30
TroubleshootingGuide
Troubleshooting....................3132
ReplacingComponents
AugerMotor...............................33
ConvectionBlower.....................34
CombustionBlower...................34
VacuumSensor..........................35
Igniter.........................................35
Gaskets.......................................36
Finish..........................................36
Glass...........................................37
ControlBoard.............................38
WiringDiagram..........................39
IllustratedPartsDetailandTag
ExplodedPartsDiagram.............40
PartsList.....................................41
SampleSafetyTag......................42
Warranty
WarrantyDetails...................4344
WarrantyReg.Form..............4546
4
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INTRODUCTION
ThankyouforpurchasingthisfineproductfromEngland’sStoveWorks!
England’sStoveWorkswasstarted,andisstillownedby,afamilythat
believesstronglyina“DoItYourself”spirit;that’sonereasonyou
foundthisproductatyourfavorite“DoItYourself”store.
Weintentionallydesign
andbuildourstovessothatanyhomeowner
canmaintaintheirunitwithbasictools,andwe’realwaysmorethan
happytoshowyouhowtodothejobaseasilyandasinexpensivelyas
possible.However,whileremainingsimple,ourstovesaredesignedto
performextremelyefficiently,helpingdelivermore
heatfromlessfuel.
PleaselookatourvastHelpsectiononourwebsiteandcallour
TechnicalSupportDepartmentat(800)2456489ifyouneedanyhelp
withyourunit.Wearenearlyalwaysableto“walkyouthrough”any
installationissues,repairs,problemsorotherquestionsthat
youmay
have.
Wishingyouyearsofefficient,qualityand“comfy”heating,
EVERYONEATENGLANDSSTOVEWORKS
PleaseNote
:Whileinformationobtainedfromourwebsiteand
throughourTechnicalSupportlineisalwaysfreeofcharge,therewill
beaservicechargeincurredwithany“onsite”repairsormaintenance
thatwemayarrange.
Thismanualencompassesallversionsofthe25PAH,includingthe55SHPAH,55
SPAHLand55TRPAH.However,forsimplicityofdescription,thestovewillbe
referredtobythegeneric25PAHdesignation.
5
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
SPECIFICATIONS
HeatingSpecifications
HeatOutputRange**............................................11,000BTU/hr25,000BTU/hr
ApproximatePelletBurnRate**...............................................1.6lb/hr4.0lb/hr
MaximumBurnTime**..............................................................................72hours
ApproximateSquareFootageHeated***.....................................800‐2000sq.ft.
HopperCapacity.....................................................................................120pounds
Dimensions
EPAandSafetyComplianceSpecifications
EPACompliance...........................................................................................Certified
ParticulateEmissions..........................................................................1.55grams/hr
Efficiency*...........................................................................................................78%
TestedTo........................... ASTME1509,ULC/ORDC1482M1990&ULCS62700
*‐Thisunitwasnottestedforefficiency;theefficiencyshownisadefaultvaluenormallyattainedbysimilar,certifiedpelletburningappliances.
**‐Heatoutput,burnrateandmaximumburntimeareheavilydependentonthetypeofpelletsburnedinthestove;assuch,thesenumbers
mayvary.
***
‐Themaximumheatingcapacityofthisunitcanvarygreatlybasedonclimate,constructionstyle,insulationandamyriadofotherfactors.
UsethisinformationinconjunctionwithaBTUlosscalculationforyourhometodetermineifthisunitwillbesufficientforyourneeds.
12.125in.
5.5in.
24.25in.
24.25in.
31.3125in.
8.4375in.
7.00in.
6
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
InstallationOverview
Whenchoosingalocationforyournewstove,thereareamultitudeof
factorsthatshouldbetakenintoaccountbeforebeginningtheinstallation.
1. TrafficPatternsTohelppreventaccidents,thestoveshouldbeplaced
inalocationwhereitisoutofthewayofnormaltravelthroughthe
home.
2. HeatFlowWhendecidingonalocationforthestove,considertheway
heatmovesthroughoutyourhome.Installthestovewhereyouneed
theheat;basementinstallationsoftendonotallowsuffic ient heatto
flowtotheupperfloorsandatopfloorinstallationwillnotallowany
heattoreachthefloorsbelow.Alwaysconsiderthatheatrisesandwill
takethepathofleastresistancewhileitisstillhot.
3. ExhaustLocationOutsidewallsaregenerallythebestplacetoinstalla
stove,sincetheyalloweasyexhaustandintakeairinstallation(usingour
DuraVentAC3000Kit,AC33000ifCa nada). Ifthereisnotafeasible
waytoinstallthestoveonanoutsidewall,thereare
methodsfor
ventingthestoveupthroughtheroof,buttheytendtobemorecostly
becausetheyinvolvetheuseofmorepelletventpipeandcanoften
makeoutsideairinstallationmoredifficult.
4. WallConstructionLocatingthestovesothattheexhaustsystemcan
passbetweenstudswillsimplifytheinstallationandeliminatetheneed
toreframeanysectionsofthewalltoaccommodatethewallthimble.
WARNING
Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityof
thisoranyotherappliance.
DoNotOverfireIfanyexternalpartstartstoglow,youareoverfiring.Reducefeed
rate.Overfiringwillvoidyourwarranty.
Complywithallminimum
clearancestocombustiblesasspecified.Failuretocomply
mayresultinahousefire.
Testedandapprovedforwoodpelletsonly.Burninganyotherfuelwillvoidyour
warranty.
7
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
ClearancestoCombustibles

UnittoSide
Wall
UnittoRear
Wall
Unitto
Corner
UnitTopto
Ceiling
Min.Ceiling
Height
Min.Alcove
Width
Max.Alcove
Depth
A B C D E F Notshown
12in. 6in. 6in. 28.5in. 60in. 48.25in. 24in.
304.8mm. 152.4mm. 152.4mm. 723.9mm. 1524mm. 1225.6mm. 609.6mm.
CAUTION
Keepchildrenaway.
Supervisechildreninthesameroomasthisappliance.
Alertchildrenandadultstothehazardsofhightemperatures.
DoNOToperatewithprotectivebarriersopenorremoved.
Keepclothing,furniture,draperiesandothercombustiblesaway.
InstallationMUSTcomplywithlocal,regional,stateandnationalcodesand
regulations.
Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdictionabout
restrictions,installationinspection,andpermits.
A
B
C
C
D
E
F
DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM
8
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
VentingIntroduction
Thispelletstoveoperatesonanegativedraftsystem,whichpullscombustionair
throughtheburnpotandpushestheexhaustairthroughtheventpipeandoutofthebuilding.
Thisunitmustbeinstalledinaccordancewiththefollowingdetaileddescriptionsofventing
techniques;notinstallingthestoveinaccordancewiththedetailslistedherecanresultinpoor
stoveperformance,propertydamage,bodilyinjuryordeath.England’sStoveWorksisnot
responsibleforanydamageincurredduetoapoororunsafeinstallation.
Ifquestionsarisepertainingtothesafeinstallationofthestove,ourTechnicalSupport
line(8002456489)isavailable.Contactyourlocalcodeofficialtobecertainyourinstallation
meetslocalandnationalfirecodesandifyou’reuncertainabouthowtosafelyinstallthestove,
westronglyrecommendcontactingalocalNFIcertifiedinstallertoperformtheinstallation.
VentingGuidelines
ALWAYSinstallventpipeinstrictadherencewiththeinstructionsandclearanc es
includedwithyourventingsystem.
DONOTconnectthispelletstovetoachimneyfluewhichalsoservesanotherappliance.
DONOTinstallafluepipedamperoranyotherrestrictivedeviceintheexhaustventing
systemofthisunit.
USEanapprovedwallthimblewhenpassingthroughawallandaceilingsupport/fire
stopwhenpassingthroughaceiling.
ONLYuse3.0”or4.0”TypeLorTypePLpipeapprovedforpelletstoveventing;DONOT
usegalvanizedorBVentpipe.
SEALeachjointofpelletventwithhightemperaturesilicone(Part#ACRTV3)to
preventsmokespillageintothehome.
AVOIDexcessivehorizontalrunsandelbows,asbothwillreducethedraftoftheventing
systemandwillresultinpoorstoveperformance.
INCLUDEasmuchverticalpipeaspossibletopreventsmokefromtheunitfromentering
yourhomeintheeventofapoweroutage.
INSPECTyourventingsystemoften,tobecertainitisclearofflyashandother
restrictions.
CLEANtheventingsystemasdetailedinthemaintenancesectionof
thismanual.
WARNING:VentingsystemsurfacesgetHOT,andcancauseburnsiftouched.
Noncombustibleshieldingorguardsmayberequired.
WARNING
INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
HOT!Donottouch!Severeburnsorclothingignitionmayresult.
Glassandothersurfacesarehotduringoperation.
9
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
AdditionalVentingInformation
Donotmixandmatchcomponentsfromdifferentpipemanufacturerswhenassembling
yourventingsystem(i.e.DoNOTuseventingpipefromonemanufacturerandathimble
fromanother).
Werequireaminimumverticalriseof36in.(3ft.)ofpipetocreatenaturaldraftinthe
system,whichhelpsevacuatesmokefromthestoveintheeventofapowerfailureor
combustionblowerfailure.
Ventingsystems15.0ft.orshortermaybecomposedentirelyof3.0in.pelletpipe;to
reducefrictionallosses,ventingsystemslongerthan15.0ft.shouldbecomposedof4.0
in.pelletpipe.
Donotterminatetheventingsystemdirectlybeneathanycombustiblestructuresuchas
aporchordeck.
FollowNFPA211ruleslistedbelowforventingsystemterminationlocationrelativeto
windowsandotheropeningsinthedwelling(seealsoVentTerminationClearances).
o NFPA211(2006ed.)Section10.4Termination:10.4.5
(1)Theexitterminalofamechanicaldraftsystemotherthandirectvent
appliances(sealedcombustionsystemappliances)shallbelocatedinaccordance
withthefollowing:
(a)Notlessthan3ft.(.91m)aboveanyforcedairinletlocatedwithin10
ft.(3.0m).
(b)Notlessthan4ft.(1.2m)below,4ft.(1.2m)horizontallyfromor1ft.
(305mm)aboveanydoor,windoworgravityairinletintoanybuilding.
(c)Notlessthan2ft.(0.61m)fromanadjacentbuildingandnotlessthan
7ft.(2.1m)abovegradewhenlocatedadjacenttopublicwalkways.
Distancebetweentheterminationopeningandgradeshouldbeaminimumof24in.
contingentonthegradesurfacebelowthetermination.Whendeterminingthe
terminationheightabovegrade,considersnowdriftlinesandcombustiblessuchas
grassor
leafaccumulation.Inareaswheresignificantsnowfallispossible,the
terminationheightmustbesufficientlyhightokeeptheterminationfreeofsnow
accumulation.
Donotusemakeshiftcompromisesduringinstallationorinstallanycomponentofthe
unitorventingsystemwhichcouldresultinahazardousinstallation.
Achimneyconnectorshallnotpassthroughanatticorroofspace,closetorsimilar
concealedspace,orafloor,orceiling.
Wherepassagethroughawall,orpartitionofcombustiblematerialisdesired,the
installationshallconformtoCAN/CSAB365.
10
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
VENT TERMINATION CLEARANCES
A) MIN. 4-FT CLEARANCE BELOW OR BESIDE ANY DOOR OR WINDOW THAT OPENS.
B) MIN. 1-FT CLEARANCE ABOVE ANY DOOR OR WINDOW THAT OPENS.
C) MIN. 2-FT CLEARANCE FROM ANY ADJACENT BUILDING.
D) MIN. 7-FT CLEARANCE FROM ANY GRADE WHEN ADJACENT TO PUBLIC
WALKWAYS.
E) MIN. 2-FT CLEARANCE ABOVE ANY GRASS, PLANTS, OR OTHER COMBUSTIBLE
MATERIALS.
F) MIN. 3-FT CLEARANCE FROM A FORCED AIR INTAKE OF ANY APPLIANCE.
G) MIN. 2-FT CLEARANCE BELOW EAVES OR OVERHANG.
H) MIN. 1-FT CLEARANCE HORIZONTALLY FROM COMBUSTIBLE WALL.
I) VENTS INSTALLED WITH MECHANICAL EXHAUSTERS SHALL TERMINATE NOT LESS THAN 12 IN.
(305MM) ABOVE THE HIGHEST POINT WHERE THEY PASS THROUGH THE ROOF SURFACE.
Notes on termination of Pellet Vent Pipe from NFPA211(2006ed.)Section10.4Termination:10.4.5 (See
also “INSTALLATION” section of manual AND additional notes above):
1. Not less than three (3) feet above any forced air inlet located within ten (10) feet.
2. Not less than four (4) feet below, four (4) feet horizontally from, or one (1) foot above any door,
window or gravity air inlet into any building.
3. Not less than two (2) feet from an adjacent building, and not less than seven (7) feet above
grade where located adjacent to public walkways.
The exhaust exit shall be arranged so that the flue gases are not directed so that it will affect people,
overheat combustible structures, or enter buildings. Forced draft systems and all parts of induced
draft systems under positive pressure during operation shall be installed gastight or to prevent
leakage of combustion products into a building. Through-the-wall vents shall not terminate over
public walkways, or where condensate or vapor could create hazards or a nuisance.
Be sure to follow local codes and all manufacturer’s instructions (including exhaust pipe).
Consult a professional installer and/or call Technical Support if you have any questions.
11
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
ApprovedVentingMethod1
:ThroughtheWall
Generallythesimplestinstallationmethod,
ventingthroughthewallusingourAC3000
kit,AC33000ifCanada(orsimilarventing
system)isalsothepreferredventing
method.Itminimizeshorizontalpipe,
allowsthestovetobeinstalledclosetothe
wallandkeepsthecleanoutteeon
the
outsideofthehouse,foreaseofcleaning.
Wheninstallinganyventingsystem,TypeL
orTypePLpipemustbeusedandall
clearancestocombustibles(listedbythe
pipemanufacturer)mustbestrictly
adheredto.
Usethepipemanufacturer’sapproved
thimbleforpassingthroughacombustible
wall,andmaintainatleasttheminimum
clearancestocombustibles.
Useanappliancecollarwherethepelletventconnectstotheexhaustoutputofthepellet
stoveandattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
Securethepelletventtotheoutsideofthehouseusingawallstrapjustbelowthe90
degreeelbow.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecificventingsystemmanufacturer’sinstructionsbeforedoing
so).
Ifthepelletventpipebeingused
isnota“TwistLock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveor
usinganalternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
This
installationtypecanbemodifiedforbasement(Basementinstallationsshouldalways
beperformedbyaprofessionalinstaller)orotherinstallationswhereintheteeandvertical
sectionofthepipewouldbeinsidethehomeandtheventingsystemwouldsimplypass
horizontallythroughthethimbleandthenterminate.
Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor
meant to be used as plans for each individual installation. Please follow all venting system
requirements, maintain the required clearances to combustibles, and follow all local codes.
For high altitude installations (above 4,000
ft.), the vent pipe should be increased from
3-inch
(
3”
)
to four-inch
(
4”
)
.
12
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
ApprovedVentingMethod2
:ThroughtheCeiling
Ventingthroughtheceiling/roofmaybetheonly
feasibleventingoptioninsomecasesandisafactory
recommendedinstallation.
Wheninstallinganyventingsystem,TypeLorType
PLpipemustbeusedandallclearancesto
combustibleslistedbythepipemanufacturermust
bestrictlyadheredto.
Usethepipemanufacturer’sapprovedceiling
supportforpassingthroughacombustibleceiling,as
wellastherequiredfirestops,radiationshields,
flashingandstormcollar.
Becertaintofollowthemanufacturer’srequired
heightofterminationabovetheroofline,and
maintainatleasttheminimumclearancesto
combustibles.
Useanappliancecollarwherethepelletvent
connectstotheexhaustoutputofthepelletstove
andattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyour
stoveor
usinganalternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
Thisventingmethodcanalsobemodifiedsothattheventingsystemrunshorizontally
throughthewallfromthestove,thentransitionstoverticalandterminatesabovethe
roofline.Whenusingthismodifiedversionofthisinstallationbecertaintocarefullyfollow
theventingsystemmanufacturer’sinstructionsdiligently.
Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor
meant to be used as plans for each individual installation. Please follow all venting system
requirements, maintain the required clearances to combustibles, and follow all local codes.
For high altitude installations (above 4,000
ft.), the vent pipe should be increased from
3-inch
(
3”
)
to four-inch
(
4”
)
.
13
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
ApprovedVentingMethod3
:ExistingChimneySystem
Usinganexistingmasonryorfactorybuiltchimneyfor
ventingistheonlyotheracceptablemethodfor
ventingthispelletunit.
UseTypeLorTypePLventingpipeuntilenteringthe
existingchimney.Usetheappropriatelysizedadapter
whentransitioningfromthepelletventpipetothe
masonry
orfactorybuiltthimbleandbecertainthat
theadapterissealedtightlytoboththepelletventing
systemandtheexistingchimney.
Beforeusinganexistingchimney,becertainitisin
goodcondition(Achimneysweepinspectionishighly
recommended).Also,makesurethechimneymeets
theminimumstandardslistedinNFPA211(A
chimneyprofessionalcanconfirmthisupon
inspection).
Ifconnectingthisstovetoafactorybuiltchimney,it
mayONLYbea6”flue,UL103HTventingsystem(ULC
S629ifCanada).Connectiontoanyotherfactory
builtchimneymayresultinapoorlyoperatingor
dangerousstoveinstallation.
Whenconnectingtoanexistingmasonrychimney,thecrosssectionalareaofthefluemust
beconsidered.Achimneywithafluelargerthan6”round(28.27sq.in.)mayrequire
reliningwithanapprovedpelletstovechimneyliningsystem.
Useanappliancecollarwherethepelletventconnectstotheexhaustoutputofthepellet
stoveandattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecific
pipemanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveor
usinganalternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as
plans for each individual installation. Please follow all venting system requirements, maintain the required clearances
to combustibles
,
and follow all local codes.
For high altitude installations (above 4,000
ft.), the vent pipe should be increased from
3-inch
(
3”
)
to four-inch
(
4”
)
.
14
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
INSTALLATION
MobileHomeInstallation
TheEngland’sStoveWorks,Inc.outsideairkitMUSTbeusedforinstallationofthisunitina
mobilehome.Pleaseseethe“OutsideAir”sectiononpage15formoreinformation
regardingoutsideairconnections.
Theoutsideairinletmustbekeptclearofleaves,iceandotherdebris.Keepingtheoutside
airinletfreeofrestrictioniscrucialtopreventingairstarvationandsmokespillage.
ThepelletstoveMUSTbesecuredtothefloorofthemobilehomeusinglagboltsandthe
holesprovidedinthebottomofthebaseforthispurpose.Outdoorairedspaceheaters
mustbeattachedtothestructure.
ThepelletstoveMUSTbegroundedwith#8solidcoppergroundingwire(orequivalent),
terminatedateachendwithanNECapprovedgroundeddevice.
CarefullyfollowallclearanceslistedintheappropriatesectionofthismanualANDfollow
theventingmanufacturer’sminimumclearancerequirements.Similarly,becertainthe
ventingsystemusedisapprovedformobilehomeuse.
InstallationmustbeinaccordancewithManufacturersHome&SafetyStandard(HUD)CFR
3280,Part24aswellasanyapplicablelocalcodes.
Usesiliconetocreateaneffectivevaporbarrieratthelocationwherethechimneyor
outsideairductingpassesthroughtotheexteriorofthestructure.
WARNING:DONOTINSTALLINASLEEPINGROOM.
CAUTION
THESTRUCTURALINTEGRITYOFTHEMANUFACTUREDHOMEFLOOR,WALL
ANDCEILING/ROOFMUSTBEMAINTAINED.
DONOTCUTTHROUGHFLOORJOISTS,WALLSTUDS,CEILINGTRUSSESORANY
OTHERSUPPORTINGMATERIALWHICHCOULDBEDETRIMENTALTOTHE
STRUCTURALINTEGRITYOFTHEHOME.
JoistShield/Firestop
MobileHome
ApprovedTypePorPL
PelletVentPipe
RoofFlashingand
StormCollar
ChimneyCap/SparkArrestor
For high altitude installations (above 4,000
ft.), the vent pipe should be increased from
3-inch
(
3”
)
to four-inch
(
4”
)
.
15
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
OUTSIDEAIRHOOKUP
Theuseofoutsidecombustionairismandatoryonthispelletstove.
Theoutsideairconnectionpipeprotrudesfromthelowerrearcenterofthestove;usethe
includedoutsideairkittoattachyourstovetooutsidecombustionair.Instructionsandall
thepartsneededtomakethe
outsideairconnectiontoyourpelletstoveareincludedwith
theoutsideairkit.
Ifitisnotfeasibletousetheincludedoutsideairhookupkitinyourstoveinstallation,other
materialsmaybeused,providedthefollowingrulesarefollowed:
o Thepipeusedforoutsideairhookupmustbemetal,withaminimumthicknessof
.0209in.(25gaugemildsteel)orgreaterandaninsidediameterofapproximately2.0
in.
o Allpipejointsandconnectionsshouldbesealedwithpipeclampsorother
mechanicalmeans,toinsurealeakfreeoutsideairconnection.
o Longrunsofpipeandexcessiveelbowsforoutsideairshouldbeavoided.Dueto
frictionalresistanceinpipe,anyexcessiveoutsideairpipingcanresultinpoorstove
performance.
o Ascreenorotherprotectiondevicemustbefittedovertheoutsideairtermination
pointtopreventrain,debrisandnuisanceanimalsfromenteringthepipingsystem.
o Increasetheoutsideairpipesizeto3.0in.diameterpipeiftheoutsideair
connectionismorethan6ft.inlength,morethantwo(2)elbowsareusedorifthe
stoveisinstalledinabasement.
Theoutsideairconnectionsystemshouldbeinspectedatleastannuallytobecertainitis
freefromblockage.
Caution
NEVERdrawoutsidecombustionairfrom:
Wall,floororceilingcavity.
Enclosedspacesuchasanattic,garageorcrawlspace.
16
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
FLOORPROTECTION
Thispelletstoverequiresanoncombustiblefloorprotectorifthestoveistobeinstalledon
acombustiblefloor.Ifthefloorthestoveistobeinstalledonisalreadynoncombustible
(i.e.aconcretefloorinabasement)andhasanRvalueequaltoor
higherthan.2,nofloor
protectionisneeded(althoughadecorativefloorprotectorcanstillbeusedforaesthetic
reasons).
PrefabricatedfloorprotectorswhichareULlisted(ULCifCanada)orequivalentcanbe
purchasedorafloorprotectorcanbebuiltfromstandardmaterials;twosheetsof.5”thick
cementboardcoveredwithceramictilewouldbeasuitablefloorprotectorwhichmeets
the.2Rvaluerequirement.
Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduce
heatingandcoolingcyclesonthefloorprotectorwhichcandamagetileandloosen
mortar
andgroutjoints.AhearthrugisNOTanapprovedsubstituteforaproperhearthpad.
FortheUS:Thefloorprotectormustextendatleast6in.(152.4mm)fromthefront&sides
and4in.(101.6mm)fromtherear.
ForCanada:The
floorprotectormustextendatleast18.0in.(457.2mm)fromthefrontof
theunit,8.0in.(203.2mm)fromthesidesoftheunitand4.0in.(101.6mm)fromtherear.
InCanada,itisrequiredthatthenoncombustiblefloorprotectorisunderneathand
extends2in.(50.8mm.)oneithersideofanyhorizontalventingrunsAND/ORisdirectly
underneathanyverticalventingpipe.
US:6.0in.
Ca
n
ada
:
8
.
0
in.
US:6.0in.
Ca
n
ada
:
8
.
0
in.
US:4.0in.
Ca
n
ada
:4.
0
in.
US:6.0in.
Ca
n
ada
:1
8
.
0
in.
17
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
DAILYOPERATION
GettingStarted
Checktoseethatthehopperiscleanandfreefromforeignmaterials.Besuretoconnect
thisunittoaworkingoutlet;werecommendusingasurgeprotectortohelpprotectthe
electroniccomponentsfromdamage.
BEFOREyourfirstfire,dryrunyourunit(nopelletfuelinthehopper)fortwentyminutes;
pressingthe“ON”buttonwiththeunitpluggedinwillinitiatethedryrun.
o Oncethe“ON”buttonispressed,youshouldimmediatelyheartheexhaustblower
startandoperatecontinuously.
o Afteraboutthreetofiveminutes,lookfortheredglowof
theigniterintheigniter
portoftheburnpottobecertainitisoperatingnormally.
o Holdthehopperlidswitch(See“IllustratedPartsDiagram”pg.38)downwithyour
fingerandchecktoseethattheaugeristurning.Releasethehopperlidswitchand
becertain
thattheaugerstopsturning.DONOTPUTYOURFINGERSINTHE
HOPPERORNEARTHEROTATINGAUGER.
Afterabouttwentyminutes,thecontrolboardshoulddisplay“E2”inthetwodisplay
windows(MoreinformationonErrorCodescanbefoundintheErrorCodesectionofthis
manual).
Atthispoint,thedryruniscompleteandyourpelletheatingapplianceisreadyfornormal
operation.
LightingaFire
Inorderforthisstovetooperate,thehoppermustfirstbefilledwithpelletfuel.Liftthe
hopperlidusingtheflushmounthandleandpourthepelletfueldirectlyintothehopper.
WerecommendusingonlypelletsmanufacturedbyPFICertifiedfacilities,since
pelletsbearingthePFIstampofapprovalwillbelowinashandmoisture,highin
BTU’s,anduniforminsizeandquality.
Thispelletstovewillperformequallywellusingsoftwoodandhardwoodpellets,and
althoughtheashmaydifferslightlyinappearanceortexture,bothtypesofpelletswillburn
cleanly
andefficientlyinthisstove.
Thispelletstoveisequippedwithanautomaticpelletignitionsystem;theonlyuserinput
requiredtolightthestoveisasimplepressofthe“On”button.
Shortlyafterpressingthe“On”button,thelettersSUwillappearinthe
heatrangeand
blowerspeedwindowsofthecontrolboard.Thisindicatesthestovehasenteredthestart
upsequenceandisoperatingnormally.
18
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
Thefuelfeedrateandcombustionairduringstartupisdeterminedbythecontrolboard,so
thestovemaybestartedonanyheatrange.
Afterapproximatelyfifteenminutes,thefireshouldbeburningbrightlyandtheSU
shoulddisappearfromthecontrolboard.Atthispoint,thestovehasbegunnormal
operationandthedisplaywindowsonthecontrolboardwillremainempty,unlesstheHeat
RangeorBlowerSpeedisadjusted.
DailyOperationNotes
Onlyhighquality,¼”(.25in.)diameterwoodpellets,shouldbeusedinthisstove.Usinglow
gradewoodpelletswithhighashcontentORwoodpelletswithahighmoisturecontent
cancausetheburnpottofillwithashatamorerapidpaceandcancauseintervalsbetween
periodicmaintenancetobecomesignificantlyshorter.Pleasereadthe“Maintenance”
sectionofthismanualthoroughlytounderstandhowfuelselectionaffectsstoveoperation,
maintenanceandcleaning.
Variationintheflameheightisnormal;notallwoodpelletfuelisuniforminsize,whichcan
affectthewaypelletsarefedintotheburnpot.Althoughtheflameheightmayincreaseand
decreaseduringoperation,thereisnolossofefficiency.
Alwaysstorewoodpelletfuelinadrylocation;storingwoodpelletfuelinadrylocation
ensuresthefuelwillremainpelletizedandlowinmoisturecontent.Also,becertainthatall
woodpelletfuelisstoredatasafedistancefromthepelletheater;storingfuelinclose
proximitytothestovecanresultinafire.
Thispelletburningroomheaterisequippedwithaspeciallydesignedburnpotwhichcomes
preinstalledfromthefactory.Thisburnpotelevatestheburningpelletsanddeliversairat
thepreciserequiredlocations.Pelletsmustonlybeburnedinthefactoryburnpot;no
modificationsshouldbemadetothisburnpotandnoadditionalgratesorotherfire
elevatorsshouldbeadded.
CAUTION
NEVERUSEGASOLINE,GASOLINETYPELANTERNFUEL,KEROSENE,CHARCOALLIGHTER
FLUID,ORSIMILARLIQUIDSTOSTARTOR“FRESHENUP”AFIREINTHISHEATER.KEEPALL
SUCHLIQUIDSWELLAWAYFROMTHEHEATERWHILEINUSE.ADDITIONALLY,NEVER
APPLY FIRE
STARTER TO ANY HOT SURFACE OR EMBERS IN THE STOVE.
DONOTUSECHEMICALSORFLUIDSTOSTARTTHEFIRE.
DONOTBURNGARBAGEORFLAMMABLEFLUIDSSUCHASGASOLINE,NAPHTHAOR
ENGINEOIL.
19
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
CONTROLBOARDSETTINGS
Thecontrolboardonthisstoveallowstheusertoadjusttheheatoutputandconvection
blowerspeed,turntheunitonandoff,andtestcomponentsforfunction(moreondiagnostic
modelater).
Thelowerbuttonsonthecontrolboard(LowFuelFeed,LowBurnAir,andAironTemp)are
notmeanttobeadjustedduringnormaloperationoftheunit.Thesebuttonsarefactory
presetandcannotbeadjustedbytheuser.
Toenergizetheunitandinitiateafire,pressthe“On”button.TheLEDabovethebutton
shouldturngreenandthecontrolboardshoulddisplay“SU”shortlyafterpressingthe
button.
Toshuttheunitdown,pressthe“Off”button.TheLEDabovethebuttonshouldturnred
andtheboardshoulddisplay“Sd”shortlyafterpressingthebutton.Thisinitiatestheshut
downsequence,andthestovewillremaininshutdownmodeuntilithascooleddown.
Toincreasetheheatoutputofthestove,pressthe“Up”heatrangebutton.Thenumberin
theheatrangedisplaywindowwillincrease,signifyingthatthecontrolboardisnow
adjustingtheheatoutputtoyourdesiredlevel.Theblowerspeedwillincreasethesame
amountastheheatrange,becausethestoveisdesignedtooperatewiththeblowerspeed
greaterthanorequaltotheheatrange.Pressingthe“Down”arrowwilldecreasetheheat
rangeandblowerspeed.
Toincreasetheblowerspeedwithoutincreasingtheheatrange,presstheBlowerSpeed
“Up”arrowuntilthedesiredblowerspeedisshowninthedisplaywindow.Pressingthe
“Down”arrowwilldecreasetheblowerspeed;however,thecontrolboardwillnotallow
theblowerspeedtobesetlowerthantheheatrange.
Caution
Thisunitismeanttooperateonlywiththeashpanandmainviewing
doorclosed.Smokespillageandaninefficient,lazyburnwillresult
fromattemptingtooperatethestovewitheitherdooropen.
Inaddition,usingfuelotherthanwoodpelletscancreateanunsafe
situationandcanalso
generateexcesscarbonmonoxide.Carbon
monoxideisanodorless,colorlessgaswhichcanbedeadly.
Pleaseburnonlywoodpellets.
20
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.
ERRORCODES
Errorcodes,or“ECodes,”arealphanumericcodesthatwillappearintheHeatRangeand
BlowerSpeedwindowsoftheControlBoardiftheunitexperiencesanabnormalcondition.
Errorcodesarethecontrolboard’swayoftellingtheuserthatsomethingisn’toperating
correctlywithinthestove,andthattheunitshouldbecarefullyinspectedbeforereigniting.See
the“TroubleShootingGuide,”page31,foradditionalinformationonerrorcodes.
E0
Whenthisisdisplayedinthecontrolboardwindows(typicallywhenrestartingafter
an“ECode”shutdown),itmeanstherearecurrentlynoerrorsandthestovewill
beginnormaloperation.
E1
Thiserrorcodeisnotusedonthisstove.Ifitisdisplayedinthecontrolboard
windows,pleasecontactTechnicalSupportandtheywilldiagnosethecauseofthe
falsecode.
E2
Whenthiscodeisdisplayedinthecontrolboardwindowitindicatesafailureto
light.Althoughthestovemayhaveignitedthepellets,thecontrolboarddidnot
registerahighenoughtemperaturetodeterminethefirewaslit.Ifafirewas
ignited,waitfortheunittocool,cleantheburnpotandrestarttheunit.
E3
Thiserrorcodeindicatesthepresetmaximumallowableexhausttemperaturewas
exceeded.Commonlyreferredtoas“OverFiring,”theE3codemeanssomethingin
thestoveiscausingtheexhaustgastobehotterthanexpected.
E4
Thiscodeisdisplayedbasedonadropintheexhausttemperature.Thiscodemeans
thefireor“proofofflame”hasbeenlost.Itusuallyresultsfromthehopperbeing
empty.
If an error code continues to display, if the error code seems
unexplainable, or if you have any other questions about error codes
and what they mean, please contact Technical Support at
(800) 245-6489.
HopperLidSafetySwitch‐Thisunitisalsoequippedwithahopperlidsafetyswitch(Part#
ACHLSB)whichisdirectlyconnectedtotheaugermotor.Intheeventthehopperlidisleft
openwhilethestoveisinoperation,thehopperlidswitchwillpreventtheaugerfrom
turning.Thisistopreventbyproductsofcombustionfromenteringthehomethroughthe
openhopperlidandalsotosimplypreventoperationwiththehopperlidopen.Improper
hopperlidsafetyswitchoperationwillresultinanaugerthatwillnotturnandthereforea
stovethatwillnot
burn.NEVERplaceyourhandoranyobjectneartheaugerwhilethestove
isconnectedto
ower.
/