England's Stove Works 55TRPAH User manual

Category
Stoves
Type
User manual

This manual is also suitable for

PELLETAUXILIARYHEATER
INSTALLATION&OPERATIONMANUAL
25PAH/55SHPAH/55TRPAH


REV.12/2011
CAUTION
Pleasereadthisentiremanualbeforeinstallationanduseofthispelletfuel
burningappliance.Keepchildren,furniture,fixturesandallcombustiblesaway
fromanyheatingappliance.
SAFETYNOTICE
Failuretofollowtheseinstructionscanresultinpropertydamage,bodilyinjury
orevendeath.Foryoursafetyandprotection,followtheinstallation
instructionsoutlinedinthismanual.Contactyourlocalbuildingorfireofficials
aboutrestrictionsandinstallationinspectionrequirements(includingpermits)
inyourarea.
SAVETHESEINSTRUCTIO NS
ManufacturedBy:
England’sStoveWorks,Inc.
POBox206
Monroe
,
VA24574
Page | 2
WARNING:
Useofoutsidecombustionairismandatorywiththisunit.
Donotoperatewiththehopperopen;lidmustbeshut
andtightlylatchedduringoperation.
Retainforyourfiles
ModelNumber________________________
DateofPurchase_______________________
DateofManufacture____________________
SerialNumber_________________________
*Thisinformationcanbefoundonthesafetytagattachedtotheundersideofthe
hopperlid.Havethisinformationonhandifyouphone thefactoryoryourdealer
regardingthisproduct.
IMPORTANT:IFYOUHAVEAPROBLEMWITHTHISUNIT,DO
NOTRETURNITTOTHEDEALER.CONTACTTECHNICAL
SUPPORT@18002456489
Note:England’sStoveWorksdoesnotrecommendusinga
pelletstoveasyouronlysourceofheat.
MobileHomeUse:
Thisfreestandingpelletunitisapprovedformobilehomeor
doublewideinstallationwiththeoutsidecombustionairhook
up.Seethe“Installation”sectionofthismanualfordetails
pertainingtomobilehomeinstallations.Mobilehome
installationmustbeinaccordancewiththeManufactured
HomeandSafet
y
Standard
(
HUD
)
,CFR3280,Part24.
Page | 3
TABLEOFCONTENTS
Introduction
Introduction.................................4
Specifications
HeatingSpecifications..................5
Dimensions...................................5
EPACompliance...........................5
Installation
InstallationOverview...................6
ClearancestoCombustibles.........7
VentingIntroduction....................8
VentingGuidelines.......................8
AdditionalVentingInformation...9
ApprovedVentingMethods
o ThroughtheWall...........10
o ThroughtheCeiling........11
o ExistingChimney............12
MobileHomeInstallation..........13
OutsideAirHookUp..................14
FloorProtection.........................15
DailyOperation
GettingStarted...........................16
LightingaFire........................1617
ControlBoardSettings...............18
ErrorCodes................................19
PowerFailure.............................20
ThermostatInstallation..............21
ThermostatOperation...............22
OptionalAccessories..................22
Maintenance
Daily
o ImportantNotes.............23
o DailyAshRemoval.....2324
o CleaningtheBurnpot.....24
Monthly
o ImportantNotes.............25
o ExhaustChamber......2526
o VentingPipe...................26
Yearly
o ImportantNotes.............27
o ExhaustBlower..............28
o ConvectionBlower.........29
o HopperFines..................29
o CheckingGaskets...........29
TroubleshootingGuide
Troubleshooting....................3031
ReplacingComponents
AugerMotor...............................32
ConvectionBlower.....................33
CombustionBlower...................33
VacuumSensor..........................34
Igniter.........................................34
Gaskets.......................................35
Finish..........................................35
Glass...........................................36
ControlBoard.............................37
WiringDiagram..........................38
IllustratedPartsDetail
ExplodedPartsDiagram.............39
PartsList.....................................40
Warranty
WarrantyDetails...................4142
WarrantyReg.Form..............4344
Page | 4
INTRODUCTION
ThankyouforpurchasingthisfineproductfromEngland’sStoveWorks!
England’sStoveWorkswasstarted,andisstillownedby,afamilythat
believesstronglyina“DoItYourself”spirit;that’sonereasonyou
foundthisproductatyourfavorite“DoItYourself”store.
Weintentionallydesign
andbuildourstovessothatanyhomeowner
canmaintaintheirunitwithbasictools,andwe’realwaysmorethan
happytoshowyouhowtodothejobaseasilyandasinexpensivelyas
possible.However,whileremainingsimple,ourstovesaredesignedto
performextremelyefficiently,helpingdelivermore
heatfromlessfuel.
PleaselookatourvastHelpsectiononourwebsiteandcallour
TechnicalSupportDepartmentat(800)2456489ifyouneedanyhelp
withyourunit.Wearenearlyalwaysableto“walkyouthrough”any
installationissues,repairs,problemsorotherquestionsthat
youmay
have.
Wishingyouyearsofefficient,qualityand“comfy”heating,
EVERYONEATENGLANDSSTOVEWORKS
PleaseNote
:Whileinformationobtainedfromourwebsiteand
throughourTechnicalSupportlineisalwaysfreeofcharge,therewill
beaservicechargeincurredwithany“onsite”repairsormaintenance
thatwemayarrange.
Thismanualencompassesallversionsofthe25PAH,includingthe55SHPAH,55
SPAHLand55TRPAH.However,forsimplicityofdescription,thestovewillbe
referredtobythegeneric25PAHdesignation.
Page | 5
SPECIFICATIONS
HeatingSpecifications
HeatOutputRange**............................................11,000BTU/hr25,000BTU/hr
ApproximatePelletBurnRate**...............................................1.6lb/hr4.0lb/hr
MaximumBurnTime**..............................................................................72hours
ApproximateSquareFootageHeated***.....................................800‐2000sq.ft.
HopperCapacity.....................................................................................120pounds
Dimensions
EPAandSafetyComplianceSpecifications
EPACompliance...........................................................................................Certified
ParticulateEmissions..........................................................................1.55grams/hr
Efficiency*...........................................................................................................78%
TestedTo........................... ASTME1509,ULC/ORDC1482M1990&ULCS62700
*‐Thisunitwasnottestedforefficiency;theefficiencyshownisadefaultvaluenormallyattainedbysimilar,certifiedpelletburningappliances.
**‐Heatoutput,burnrateandmaximumburntimeareheavilydependentonthetypeofpelletsburnedinthestove;assuch,thesenumbers
mayvary.
***
‐Themaximumheatingcapacityofthisunitcanvarygreatlybasedonclimate,constructionstyle,insulationandamyriadofotherfactors.
UsethisinformationinconjunctionwithaBTUlosscalculationforyourhometodetermineifthisunitwillbesufficientforyourneeds.
12.125in.
5.5in.
24.25in.
24.25in.
31.3125in.
8.4375in.
7.00in.
Page | 6
INSTALLATION
InstallationOverview
Whenchoosingalocationforyournewstove,thereareamultitudeof
factorsthatshouldbetakenintoaccountbeforebeginningtheinstallation.
1. TrafficPatternsTohelppreventaccidents,thestoveshouldbeplaced
inalocationwhereitisoutofthewayofnormaltravel
throughthe
home.
2. HeatFlowWhendecidingonalocationforthestove,considertheway
heatmovesthroughoutyourhome.Installthestovewhereyouneed
theheat;basementinstallationsoftendonotallowsuffic ient heatto
flowtotheupperfloorsandatopfloorinstallation
willnotallowany
heattoreachthefloorsbelow.Alwaysconsiderthatheatrisesandwill
takethepathofleastresistancewhileitisstillhot.
3. ExhaustLocationOutsidewallsaregenerallythebestplacetoinstalla
stove,sincetheyalloweasyexhaustandintakeair
installation(usingour
DuraVentAC3000Kit).Ifthereisnotafeasiblewaytoinstallthestove
onanoutsidewall,therearemethodsforventingthestoveupthrough
theroof,buttheytendtobemorecostlybecausetheyinvolvetheuse
ofmorepelletventpipe
andcanoftenmakeoutsideairinstallation
moredifficult.
4. WallConstructionLocatingthestovesothattheexhaustsystemcan
passbetweenstudswillsimplifytheinstallationandeliminatetheneed
toreframeanysectionsofthewalltoaccommodatethewallthimble.
WARNING
Donotstoreorusegasolineorotherflammablevaporsandliquidsinthevicinityof
thisoranyotherappliance.
DoNotOverfireIfanyexternalpartstartstoglow,youareoverfiring.Reducefeed
rate.Overfiringwillvoidyourwarranty.
Complywithallminimum
clearancestocombustiblesasspecified.Failuretocomply
mayresultinahousefire.
Testedandapprovedforwoodpelletsonly.Burninganyotherfuelwillvoidyour
warranty.
Page | 7
INSTALLATION
ClearancestoCombustibles

UnittoSide
Wall
UnittoRear
Wall
Unitto
Corner
UnitTopto
Ceiling
Min.Ceiling
Height
Min.Alcove
Width
Max.Alcove
Depth
A B C D E F Notshown
12in. 6in. 6in. 28.5in. 60in. 48.25in. 24in.
304.8mm. 152.4mm. 152.4mm. 723.9mm. 1524mm. 1225.6mm. 609.6mm.
CAUTION
Keepchildrenaway.
Supervisechildreninthesameroomasthisappliance.
Alertchildrenandadultstothehazardsofhightemperatures.
DoNOToperatewithprotectivebarriersopenorremoved.
Keepclothing,furniture,draperiesandothercombustiblesaway.
InstallationMUSTcomplywithlocal,regional,stateandnationalcodesand
regulations.
Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdictionabout
restrictions,installationinspection,andpermits.
A
B
C
C
D
E
F
DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM
Page | 8
INSTALLATION
VentingIntroduction
Thispelletstoveoperatesonanegativedraftsystem,whichpullscombustionair
throughtheburnpotandpushestheexhaustairthroughtheventpipeandoutofthebuilding.
Thisunitmustbeinstalledinaccordancewiththefollowingdetaileddescriptionsofventing
techniques;notinstallingthestoveinaccordancewiththedetailslistedherecanresultinpoor
stoveperformance,propertydamage,bodilyinjuryordeath.England’sStoveWorksisnot
responsibleforanydamageincurredduetoapoororunsafeinstallation.
Ifquestionsarisepertainingtothesafeinstallationofthestove,ourTechnicalSupport
line(8002456489)isavailable.Contactyourlocalcodeofficialtobecertainyourinstallation
meetslocalandnationalfirecodesandifyou’reuncertainabouthowtosafelyinstallthestove,
westronglyrecommendcontactingalocalNFIcertifiedinstallertoperformtheinstallation.
VentingGuidelines
ALWAYSinstallventpipeinstrictadherencewiththeinstructionsandclearanc es
includedwithyourventingsystem.
DONOTconnectthispelletstovetoachimneyfluewhichalsoservesanotherappliance.
DONOTinstallafluepipedamperoranyotherrestrictivedeviceintheexhaustventing
systemofthisunit.
USEanapprovedwallthimblewhenpassingthroughawallandaceilingsupport/fire
stopwhenpassingthroughaceiling.
ONLYuse3.0”or4.0”TypeLorTypePLpipeapprovedforpelletstoveventing;DONOT
usegalvanizedorBVentpipe.
SEALeachjointofpelletventwithhightemperaturesilicone(Part#ACRTV3)to
preventsmokespillageintothehome.
AVOIDexcessivehorizontalrunsandelbows,asbothwillreducethedraftoftheventing
systemandwillresultinpoorstoveperformance.
INCLUDEasmuchverticalpipeaspossibletopreventsmokefromtheunitfromentering
yourhomeintheeventofapoweroutage.
INSPECTyourventingsystemoften,tobecertainitisclearofflyashandother
restrictions.
CLEANtheventingsystemasdetailedinthemaintenancesectionof
thismanual.
WARNING:VentingsystemsurfacesgetHOT,andcancauseburnsiftouched.
Noncombustibleshieldingorguardsmayberequired.
WARNING
INSTALLVENTATCLEARANCESSPECIFIEDBYTHEVENTMANUFACTURER.
HOT!Donottouch!Severeburnsorclothingignitionmayresult.
Glassandothersurfacesarehotduringoperation.
Page | 9
INSTALLATION
AdditionalVentingInformation
Donotmixandmatchcomponentsfromdifferentpipemanufacturerswhenassembling
yourventingsystem(i.e.DoNOTuseventingpipefromonemanufacturerandathimble
fromanother).
Werequireaminimumverticalriseof36in.(3ft.)ofpipetocreatenaturaldraftinthe
system,whichhelpsevacuatesmokefromthestoveintheeventofapowerfailureor
combustionblowerfailure.
Ventingsystems15.0ft.orshortermaybecomposedentirelyof3.0in.pelletpipe;to
reducefrictionallosses,ventingsystemslongerthan15.0ft.shouldbecomposedof4.0
in.pelletpipe.
Donotterminatetheventingsystemdirectlybeneathanycombustiblestructuresuchas
aporchordeck.
FollowNFPA211ruleslistedbelowforventingsystemterminationlocationrelativeto
windowsandotheropeningsinthedwelling.
o NFPA211(2003ed.)Section10.4Termination:10.4.5
(1)Theexitterminalofamechanicaldraftsystemotherthandirectvent
appliances(sealedcombustionsystemappliances)shallbelocatedinaccordance
withthefollowing:
(a)Notlessthan3ft.(.91m)aboveanyforcedairinletlocatedwithin10
ft.(3.0m).
(b)Notlessthan4ft.(1.2m)below,4ft.(1.2m)horizontallyfromor1ft.
(305mm)aboveanydoor,windoworgravityairinletintoanybuilding.
(c)Notlessthan2ft.(0.61m)fromanadjacentbuildingandnotlessthan
7ft.(2.1m)above
gradewhenlocatedadjacenttopublicwalkways.
Distancebetweentheterminationopeningandgradeshouldbeaminimumof24in.
contingentonthegradesurfacebelowthetermination.Whendeterminingthe
terminationheightabovegrade,considersnowdriftlinesandcombustiblessuchas
grassorleafaccumulation.Inareaswheresignificantsnowfallispossible,the
terminationheightmustbesufficientlyhightokeeptheterminationfreeofsnow
accumulation.
Donotusemakeshiftcompromisesduringinstallationorinstallanycomponentofthe
unitorventingsystemwhichcouldresultinahazardousinstallation.
Achimneyconnectorshallnotpassthroughanatticorroofspace,closetorsimilar
concealedspace,orafloor,orceiling.
Wherepassagethroughawall,orpartitionofcombustiblematerialisdesired,the
installationshallconformtoCAN/CSAB365.
Page | 10
INSTALLATION
ApprovedVentingMethod1
:ThroughtheWall
Generallythesimplestinstallationmethod,
ventingthroughthewallusingourAC3000
kit(orsimilarventingsystem)isalsothe
preferredventingmethod.Itminimizes
horizontalpipe,allowsthestovetobe
installedclosetothewallandkeepsthe
cleanoutteeontheoutsideofthe
house,
foreaseofcleaning.
Wheninstallinganyventingsystem,TypeL
orTypePLpipemustbeusedandall
clearancestocombustibles(listedbythe
pipemanufacturer)mustbestrictly
adheredto.
Usethepipemanufacturer’sapproved
thimbleforpassingthroughacombustible
wall,andmaintainatleasttheminimumclearancestocombustibles.
Useanappliancecollarwherethepelletventconnectstotheexhaustoutputofthepellet
stoveandattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
Securethepelletventtotheoutsideofthehouseusingawallstrapjustbelowthe90
degreeelbow.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecificventingsystemmanufacturer’sinstructionsbeforedoing
so).
Ifthepelletventpipebeingusedisnota“Twist
Lock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveor
usinganalternativemethod,asdescribedinthe“OutsideAir”section,onpage14.
Thisinstallationtypecanbe
modifiedforbasement(Basementinstallationsshouldalways
beperformedbyaprofessionalinstaller)orotherinstallationswhereintheteeandvertical
sectionofthepipewouldbeinsidethehomeandtheventingsystemwouldsimplypass
horizontallythroughthethimbleandthenterminate.
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(
4”
)
.
Page | 11
INSTALLATION
ApprovedVentingMethod2
:ThroughtheCeiling
Ventingthroughtheceiling/roofmaybetheonly
feasibleventingoptioninsomecasesandisafactory
recommendedinstallation.
Wheninstallinganyventingsystem,TypeLorType
PLpipemustbeusedandallclearancesto
combustibleslistedbythepipemanufacturermust
bestrictlyadheredto.
Usethepipemanufacturer’sapprovedceiling
supportforpassingthroughacombustibleceiling,as
wellastherequiredfirestops,radiationshields,
flashingandstormcollar.
Becertaintofollowthemanufacturer’srequired
heightofterminationabovetheroofline,and
maintainatleasttheminimumclearancesto
combustibles.
Useanappliancecollarwherethepelletvent
connectstotheexhaustoutputofthepelletstove
andattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyour
stoveor
usinganalternativemethod,asdescribedinthe“OutsideAir”section,onpage14.
Thisventingmethodcanalsobemodifiedsothattheventingsystemrunshorizontally
throughthewallfromthestove,thentransitionstoverticalandterminatesabovethe
roofline.Whenusingthismodifiedversionofthisinstallationbecertaintocarefullyfollow
theventingsystemmanufacturer’sinstructionsdiligently.
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(
4”
)
.
Page | 12
INSTALLATION
ApprovedVentingMethod3
:ExistingChimneySystem
Usinganexistingmasonryorfactorybuiltchimneyfor
ventingistheonlyotheracceptablemethodfor
ventingthispelletunit.
UseTypeLorTypePLventingpipeuntilenteringthe
existingchimney.Usetheappropriatelysizedadapter
whentransitioningfromthepelletventpipetothe
masonryorfactorybuiltthimbleandbecertainthat
theadapterissealedtightlytoboththepelletventing
systemandtheexistingchimney.
Beforeusinganexistingchimney,becertainitisin
goodcondition(Achimneysweepinspectionishighly
recommended).Also,makesurethechimneymeets
theminimumstandardslistedinNFPA211(A
chimneyprofessionalcanconfirmthisupon
inspection).
Ifconnectingthisstovetoafactorybuiltchimney,it
mayONLYbea6”flue,UL103HTventingsystem.
Connectiontoanyotherfactorybuiltchimneymay
resultinapoorlyoperatingordangerousstove
installation.
Whenconnectingtoanexistingmasonrychimney,thecrosssectionalareaofthefluemust
beconsidered.Achimneywithafluelargerthan6”round(28.27sq.in.)mayrequire
reliningwithanapprovedpelletstovechimneyliningsystem.
Useanappliancecollarwherethepellet
ventconnectstotheexhaustoutputofthepellet
stoveandattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetal
screws.
SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemis
leakfree(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrews
arerequiredateachpipejoint.
Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveor
usinganalternativemethod,asdescribedinthe“OutsideAir”section,onpage14.
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual
installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local
codes.
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(
4”
)
.
Page | 13
INSTALLATION
MobileHomeInstallation
TheEngland’sStoveWorks,Inc.outsideairkitMUSTbeusedforinstallationofthisunitina
mobilehome.Pleaseseethe“OutsideAir”sectiononpage14formoreinformation
regardingoutsideairconnections.
Theoutsideairinletmustbekeptclearofleaves,iceandotherdebris.Keepingtheoutside
airinletfreeofrestrictioniscrucialtopreventingairstarvationandsmokespillage.
ThepelletstoveMUSTbesecuredtothefloorofthemobilehomeusinglagboltsandthe
holesprovidedinthebottomofthebaseforthispurpose.Outdooraired
spaceheaters
mustbeattachedtothestructure.
ThepelletstoveMUSTbegroundedwith#8solidcoppergroundingwire(orequivalent),
terminatedateachendwithanNECapprovedgroundeddevice.
CarefullyfollowallclearanceslistedintheappropriatesectionofthismanualANDfollow
theventing
manufacturer’sminimumclearancerequirements.Similarly,becertainthe
ventingsystemusedisapprovedformobilehomeuse.
InstallationmustbeinaccordancewithManufacturersHome&SafetyStandard(HUD)CFR
3280,Part24aswellasanyapplicablelocalcodes.
Usesiliconetocreateaneffectivevaporbarrieratthelocationwherethechimneyor
outsideairductingpassesthroughtotheexteriorofthestructure.
WARNING:DONOTINSTALLINASLEEPINGROOM.
CAUTION
THESTRUCTURALINTEGRITYOFTHEMANUFACTUREDHOMEFLOOR,WALL
ANDCEILING/ROOFMUSTBEMAINTAINED.
DONOTCUTTHROUGHFLOORJOISTS,WALLSTUDS,CEILINGTRUSSESORANY
OTHERSUPPORTINGMATERIALWHICHCOULDBEDETRIMENTALTOTHE
STRUCTURALINTEGRITYOFTHEHOME.
JoistShield/Firestop
MobileHome
ApprovedTypePorPL
PelletVentPipe
RoofFlashingand
StormCollar
ChimneyCap/SparkArrestor
For high altitude installations (above 4,000 ft.), the vent pipe should be
increased from 3-inch
(
3”
)
to four-inch
(
4”
)
.
Page | 14
OUTSIDEAIRHOOKUP
Theuseofoutsidecombustionairismandatoryonthispelletstove.
Theoutsideairconnectionpipeprotrudesfromthelowerrearcenterofthestove;usethe
includedoutsideairkittoattachyourstovetooutsidecombustionair.Instructionsandall
thepartsneededtomakethe
outsideairconnectiontoyourpelletstoveareincludedwith
theoutsideairkit.
Ifitisnotfeasibletousetheincludedoutsideairhookupkitinyourstoveinstallation,other
materialsmaybeused,providedthefollowingrulesarefollowed:
o Thepipeusedforoutsideairhookupmustbemetal,withaminimumthicknessof
.0209in.(25gaugemildsteel)orgreaterandaninsidediameterofapproximately
2.0in.
o Allpipejointsandconnectionsshouldbesealedwithpipeclampsorother
mechanicalmeans,toinsurealeakfreeoutsideairconnection.
o Longrunsofpipeandexcessiveelbowsforoutsideairshouldbeavoided.Dueto
frictionalresistanceinpipe,anyexcessiveoutsideairpipingcanresultinpoorstove
performance.
o Ascreenorotherprotectiondevicemustbefittedovertheoutsideairtermination
pointtopreventrain,debrisandnuisanceanimalsfromenteringthepipingsystem.
o Increasetheoutsideairpipesizeto3.0in.diameterpipeiftheoutsideair
connectionismorethan6ft.inlength,morethantwo(2)elbowsareusedorifthe
stoveisinstalledinabasement.
Theoutsideairconnectionsystemshouldbeinspectedatleastannuallytobecertainitis
freefromblockage.
Caution
NEVERdrawoutsidecombustionairfrom:
Wall,floororceilingcavity.
Enclosedspacesuchasanattic,garageorcrawlspace.
Page | 15
FLOORPROTECTION
Thispelletstoverequiresanoncombustiblefloorprotectorifthestoveistobeinstalledon
acombustiblefloor.Ifthefloorthestoveistobeinstalledonisalreadynoncombustible
(i.e.aconcretefloorinabasement)andhasanRvalueequaltoor
higherthan.2,nofloor
protectionisneeded(althoughadecorativefloorprotectorcanstillbeusedforaesthetic
reasons).
PrefabricatedfloorprotectorswhichareULlistedorequivalentcanbepurchasedorafloor
protectorcanbebuiltfromstandardmaterials;twosheetsof.5”thickcementboard
covered
withceramictilewouldbeasuitablefloorprotectorwhichmeetsthe.2Rvalue
requirement.
Whenusinganyfloorprotector,considerthatthisstoveisnotonlyheavybutwillinduce
heatingandcoolingcyclesonthefloorprotectorwhichcandamagetileandloosenmortar
andgroutjoints.AhearthrugisNOTanapprovedsubstituteforaproperhearthpad.
FortheUS:Thefloorprotectormustextendatleast6in.(152.4mm)fromthefront&sides
and4in.(101.6mm)fromtherear.
ForCanada:Thefloorprotectormustextendatleast18.0in.(457.2mm)fromthefrontof
theunit,8.0in.(203.2mm)fromthesidesoftheunitand4.0in.(101.6mm)fromtherear.
InCanada,itisrequiredthatthenoncombustiblefloorprotectorisunderneathand
extends2in.(50.8mm.)oneithersideofanyhorizontalventingrunsAND/ORisdirectly
underneathanyverticalventingpipe.
US:6.0in.
Canada:
8.0
in.
US:6.0in.
Ca
n
ada
:
8
.
0
in.
US:4.0in.
Ca
n
ada
:4.
0
in.
US:6.0in.
Ca
n
ada
:1
8
.
0
in.
Page | 16
DAILYOPERATION
GettingStarted
Checktoseethatthehopperiscleanandfreefromforeignmaterials.Besuretoconnect
thisunittoaworkingoutlet;werecommendusingasurgeprotectortohelpprotectthe
electroniccomponentsfromdamage.
BEFOREyourfirstfire,dryrunyourunit(nopelletfuelinthehopper)fortwentyminutes;
pressingthe“ON”buttonwiththeunitpluggedinwillinitiatethedryrun.
o Oncethe“ON”buttonispressed,youshouldimmediatelyheartheexhaustblower
startandoperatecontinuously.
o Afteraboutthreetofiveminutes,lookfortheredglowoftheigniterintheigniter
portoftheburnpottobecertainitisoperatingnormally.
o Holdthehopperlidswitch(See“IllustratedPartsDiagram”pg.38)downwithyour
fingerandchecktoseethattheaugeristurning.Releasethehopperlidswitchand
becertainthattheaugerstopsturning.DONOTPUTYOURFINGERSINTHE
HOPPERORNEARTHEROTATINGAUGER.
Afterabouttwentyminutes,thecontrolboardshoulddisplay“E2”inthetwodisplay
windows(MoreinformationonErrorCodescanbefoundintheErrorCodesectionofthis
manual).
Atthispoint,thedryruniscompleteandyourpelletheatingapplianceisreadyfornormal
operation.
LightingaFire
Inorderforthisstovetooperate,thehoppermustfirstbefilledwithpelletfuel.Liftthe
hopperlidusingtheflushmounthandleandpourthepelletfueldirectlyintothehopper.
WerecommendusingonlypelletsmanufacturedbyPFICertifiedfacilities,since
pelletsbearingthePFIstampofapprovalwillbelowinashandmoisture,highin
BTU’s,anduniforminsizeandquality.
Thispelletstovewillperformequallywellusingsoftwoodandhardwoodpellets,and
althoughtheashmaydifferslightlyinappearanceortexture,bothtypesofpelletswillburn
cleanlyandefficientlyinthisstove.
Thispelletstoveisequippedwithanautomaticpelletignitionsystem;theonlyuserinput
requiredtolightthestoveisasimplepressofthe“On”button.
Page | 17
Shortlyafterpressingthe“On”button,thelettersSUwillappearintheheatrangeand
blowerspeedwindowsofthecontrolboard.Thisindicatesthestovehasenteredthestart
upsequenceandisoperatingnormally.
Thefuelfeedrateandcombustionairduringstart
upisdeterminedbythecontrolboard,so
thestovemaybestartedonanyheatrange.
Afterapproximatelyfifteenminutes,thefireshouldbeburningbrightlyandtheSU
shoulddisappearfromthecontrolboard.Atthispoint,thestovehasbegunnormal
operationandthedisplaywindowsonthecontrolboardwillremainempty,unlesstheHeat
RangeorBlowerSpeedisadjusted.
DailyOperationNotes
Onlyhighquality,¼”(.25in.)diameterwoodpellets,shouldbeusedinthisstove.Usinglow
gradewoodpelletswithhighashcontentORwoodpelletswithahighmoisturecontent
cancausetheburnpottofillwithashatamorerapidpaceandcancauseintervalsbetween
periodicmaintenancetobecomesignificantlyshorter.Pleasereadthe“Maintenance”
sectionofthismanualthoroughlytounderstandhowfuelselectionaffectsstoveoperation,
maintenanceandcleaning.
Variationintheflameheightisnormal;notallwoodpelletfuelisuniforminsize,whichcan
affectthewaypelletsarefedintotheburnpot.Althoughtheflameheightmayincreaseand
decreaseduringoperation,thereisnolossofefficiency.
Alwaysstorewoodpelletfuelinadrylocation;storingwoodpelletfuelinadrylocation
ensuresthefuelwillremainpelletizedandlowinmoisturecontent.Also,becertainthatall
woodpelletfuelisstoredatasafedistancefromthepelletheater;storingfuelinclose
proximitytothestovecanresultinafire.
Thispelletburningroomheaterisequippedwithaspeciallydesignedburnpotwhichcomes
preinstalledfromthefactory.Thisburnpot
elevatestheburningpelletsanddeliversairat
thepreciserequiredlocations.Pelletsmustonlybeburnedinthefactoryburnpot;no
modificationsshouldbemadetothisburnpotandnoadditionalgratesorotherfire
elevatorsshouldbeadded.
CAUTION
NEVERUSEGASOLINE,GASOLINETYPELANTERNFUEL,KEROSENE,CHARCOALLIGHTER
FLUID,ORSIMILARLIQUIDSTOSTARTOR“FRESHENUP”AFIREINTHISHEATER.KEEPALL
SUCHLIQUIDSWELLAWAYFROMTHEHEATERWHILEINUSE.ADDITIONALLY,NEVER
APPLY FIRE
STARTER TO ANY HOT SURFACE OR EMBERS IN THE STOVE.
DONOTUSECHEMICALSORFLUIDSTOSTARTTHEFIRE.
DONOTBURNGARBAGEORFLAMMABLEFLUIDSSUCHASGASOLINE,NAPHTHAOR
ENGINEOIL.
Page | 18
CONTROLBOARDSETTINGS
Thecontrolboardonthisstoveallowstheusertoadjusttheheatoutputandconvection
blowerspeed,turntheunitonandoff,andtestcomponentsforfunction(moreondiagnostic
modelater).
Thelowerbuttonsonthecontrolboard(LowFuelFeed,LowBurnAir,andAiron
Temp)are
notmeanttobeadjustedduringnormaloperationoftheunit.Thesebuttonsarefactory
presetandcannotbeadjustedbytheuser.
Toenergizetheunitandinitiateafire,pressthe“On”button.TheLEDabovethebutton
shouldturngreenandthecontrol
boardshoulddisplay“SU”shortlyafterpressingthe
button.
Toshuttheunitdown,pressthe“Off”button.TheLEDabovethebuttonshouldturnred
andtheboardshoulddisplay“Sd”shortlyafterpressingthebutton.Thisinitiatestheshut
downsequence,andthestovewillremaininshutdownmodeuntilithascooleddown.
Toincreasetheheatoutputofthestove,pressthe“Up”heatrangebutton.Thenumberin
theheatrangedisplaywindowwillincrease,signifyingthatthecontrolboardisnow
adjustingtheheatoutputtoyourdesiredlevel.Theblowerspeedwillincreasethesame
amountastheheatrange,becausethestoveisdesignedtooperatewiththeblowerspeed
greaterthanorequaltotheheatrange.Pressingthe“Down”arrowwilldecreasetheheat
rangeandblowerspeed.
Toincreasetheblowerspeedwithoutincreasingtheheatrange,presstheBlowerSpeed
“Up”arrowuntilthedesiredblowerspeedisshowninthedisplaywindow.Pressingthe
“Down”arrowwilldecreasetheblowerspeed;however,thecontrolboardwillnotallow
theblowerspeedtobesetlowerthantheheatrange.
Caution
Thisunitismeanttooperateonlywiththeashpanandmainviewing
doorclosed.Smokespillageandaninefficient,lazyburnwillresult
fromattemptingtooperatethestovewitheitherdooropen.
Inaddition,usingfuelotherthanwoodpelletscancreateanunsafe
situationandcanalso
generateexcesscarbonmonoxide.Carbon
monoxideisanodorless,colorlessgaswhichcanbedeadly.Pleaseburn
onlywoodpellets.
Page | 19
ERRORCODES
Errorcodes,or“ECodes,”arealphanumericcodesthatwillappearintheHeatRangeand
BlowerSpeedwindowsoftheControlBoardiftheunitexperiencesanabnormalcondition.
Errorcodesarethecontrolboard’swayoftellingtheuserthatsomethingisn’toperating
correctlywithinthestove,andthattheunitshouldbecarefullyinspectedbeforereigniting.See
the“TroubleShootingGuide,”page30,foradditionalinformationonerrorcodes.
E0
Whenthisisdisplayedinthecontrolboardwindows(typicallywhenrestartingafter
an“ECode”shutdown),itmeanstherearecurrentlynoerrorsandthestovewill
beginnormaloperation.
E1
Thiserrorcodeisnotusedonthisstove.Ifitisdisplayedinthecontrolboard
windows,pleasecontactTechnicalSupportandtheywilldiagnosethecauseofthe
falsecode.
E2
Whenthiscodeisdisplayedinthecontrolboardwindowitindicatesafailureto
light.Althoughthestovemayhaveignitedthepellets,thecontrolboarddidnot
registerahighenoughtemperaturetodeterminethefirewaslit.Ifafirewas
ignited,waitfortheunittocool,cleantheburnpotandrestarttheunit.
E3
Thiserrorcodeindicatesthepresetmaximumallowableexhausttemperaturewas
exceeded.Commonlyreferredtoas“OverFiring,”theE3codemeanssomethingin
thestoveiscausingtheexhaustgastobehotterthanexpected.
E4
Thiscodeisdisplayedbasedonadropintheexhausttemperature.Thiscodemeans
thefireor“proofofflame”hasbeenlost.Itusuallyresultsfromthehopperbeing
empty.
If an error code continues to display, if the error code
seems unexplainable, or if you have any other
questions about error codes and what they mean,
please contact Technical Support at (800)245-6489.
Page | 20
POWERFAILURE
Ifthepowertotheunitisinterruptedforapproximatelythreeminutesorless,theunitwill
resumeoperationwhenpowerisrestoredaccordingtothefollowingtable:
Unit’sStateBeforePowerLoss StateWhenPowerReturns
ON StartUp
StartUp StartUp
ShutDown ShutDown
OFF OFF
Ifthepowerisinterruptedformorethan(approximately)threeminutes,theunit
willbe“OFF”whenpowerreturns.
IMPORTANTDoNOTopenthehopperlidorthedoortotheunitduringpower
outage.Opentheclosestoutsidedoorandawindowtoreducethechanceofany
combustionbyproductsenteringthehomefromthestove.
Waitforthepowertoberestoredandthenpressthe“ON”buttontorestartthe
unit,ifnecessary.
Caution
ShockHazard
Pressthe“Off”buttonandlettheappliancecompletelycoolBEFORE
unpluggingtheapplianceandbeginninganymaintenanceorcomponent
replacement.
Riskofshockifapplianceisnotunpluggedbeforeservice.
SmokeDetectors
England’sStoveWorks,Inc.highlyrecommendstheuseofsmokedetectorsin
everyroomofthehouse.However,locatingasmokedetect ordirectlyabove
thisunitcanresultinnuisance alarms.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46

England's Stove Works 55TRPAH User manual

Category
Stoves
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI