Watts 654 Quick Set-up

  • Hello! I am an AI chatbot trained to assist you with the Watts 654 Quick Set-up. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!

of2 ©203WattsRadiant

 




















Snow/Ice
Sensor090
Outdoor
Sensor
070
Supply
Sensor
082
Relay
System
Pump
Relay
Optional
tN4
Communication
Snow
Sensor095
Slab
Sensor072
Slab
Brn
Slab
Brn
Com
BlkYel Blu Red
Com
BlkYel Blu Red
Or And/Or
Snow
Sensor
095
C tN4
Modulating
Boiler
T
T
+
Transformer
L
N
C
R
Slab
Brn
+
Mod
tN4Aux Ht R C
Bret
Out/
Com
BlkYel Blu Red Sup
No Power
5V(ac)


Backof
Control

Thecontrolislocallylockedandtheaccess
levelcannotbechanged.SettoLockwhen
installationhasbeencompleted.

Thecontrolisunlockedandtheaccess
levelmaybechanged.GototheToolbox
menutochangetheaccesslevel.Setto
Unlockduringtheinstallationprocess.
Meets Class B: ICES & FCC Part 15
Power: 24 V (ac) ±10%, 60 Hz, Class 2,
16 VA standby, 100 VA fully loaded
Relays: 24 V (ac) 2 A, 3.5 A combined
1058-04
Switch
Settings
www.WattsRadiant.com
Order #81016552
Designed and assembled in Canada
Lock
Unused
Unlock
ON
2
H1226A
Snow Melting Control 654
A Watts Water Technologies Company
Springeld,MO•Tel.(800)276-249•Fax:(47)864-86•www.wattsradiant.com
Burlington,ONT.•Tel.(905)332-4090•Fax:(905)332-7068•www.watts.ca
IS-WR-Snow_Melting_Control-654328 ©203WattsRadiant






ENTER
HomeButton
Returntothe
HomeScreen
Pressandholdfor3
secondstoaccessthe
programmingmenus.
Touchtogotothe
nextsetting
Touchtoquicklyenter
theViewmenu
Touchto
adjustsettings
Operation
Field
StatusField
Touchtodisplay
RunTime,
Outdoor&Slab
Temperature
Touchto
MeltorStop
Touchtoturnsystem
offwhileaway

 

Selectthecontrolapplicationmode.
PWM=HydronicPulseWidthModulation.
BOIL=Hydronicboilerheatssnowmelting
system.
MIX=Hydronicmixingvalveorinjection
pumpheatssnowmeltingsystem.
ELEC=Electricsnowmelt.
090=TandemSnow/IceDetection
Default=PWM

SelectifaSnow/IceSensor090orSnow
Sensor095isinstalled.
Default=090

SelectifaSlabSensor072isinstalledto
measuretheslabtemperature.
Default=ON

Selectiftheslabshouldbeprotectedfromlarge
temperaturedifferentialstoavoidcrackingthe
concreteduetohightensilestress.
Default=ON
TheSystemMenuprovidessettingsonhowtoconfigureandoperatethemechanicalequipment.
 

SelectiftheOut/Bretwiringterminalis
connectedtoanoutdoorsensororaboiler
returnsensor.
Default=OUT

EconoMeltallowstheusertomechanically
removesnowthenmanuallystartthesystem
tomeltthethinsnowlayerorice.
Default=OFF


Selectifthesystempumplocatedonthe
tekmarNet
®
SystemControlshouldoperate
whenthesnowmeltzoneisheating.
Conditions:ApplicationModeissettoPWM,
BoilorMixandBoilerTypeissettoCTRL
(tN4control).
Default=ON

Selectiftheauxiliaryrelayshouldfunction
assystempumporasanalert.
Default=SYS

Selecttolimittheamountofmeltingrun
time.
Default=3.0days
/