A Watts Water Technologies Company
Springeld,MO•Tel.(800)276-249•Fax:(47)864-86•www.wattsradiant.com
Burlington,ONT.•Tel.(905)332-4090•Fax:(905)332-7068•www.watts.ca
IS-WR-Snow_Melting_Control-654328 ©203WattsRadiant
ENTER
HomeButton
Returntothe
HomeScreen
Pressandholdfor3
secondstoaccessthe
programmingmenus.
Touchtogotothe
nextsetting
Touchtoquicklyenter
theViewmenu
Touchto
adjustsettings
Operation
Field
StatusField
Touchtodisplay
RunTime,
Outdoor&Slab
Temperature
Touchto
MeltorStop
Touchtoturnsystem
offwhileaway
Selectthecontrolapplicationmode.
PWM=HydronicPulseWidthModulation.
BOIL=Hydronicboilerheatssnowmelting
system.
MIX=Hydronicmixingvalveorinjection
pumpheatssnowmeltingsystem.
ELEC=Electricsnowmelt.
090=TandemSnow/IceDetection
Default=PWM
SelectifaSnow/IceSensor090orSnow
Sensor095isinstalled.
Default=090
SelectifaSlabSensor072isinstalledto
measuretheslabtemperature.
Default=ON
Selectiftheslabshouldbeprotectedfromlarge
temperaturedifferentialstoavoidcrackingthe
concreteduetohightensilestress.
Default=ON
TheSystemMenuprovidessettingsonhowtoconfigureandoperatethemechanicalequipment.
SelectiftheOut/Bretwiringterminalis
connectedtoanoutdoorsensororaboiler
returnsensor.
Default=OUT
EconoMeltallowstheusertomechanically
removesnowthenmanuallystartthesystem
tomeltthethinsnowlayerorice.
Default=OFF
Selectifthesystempumplocatedonthe
tekmarNet
®
SystemControlshouldoperate
whenthesnowmeltzoneisheating.
Conditions:ApplicationModeissettoPWM,
BoilorMixandBoilerTypeissettoCTRL
(tN4control).
Default=ON
Selectiftheauxiliaryrelayshouldfunction
assystempumporasanalert.
Default=SYS
Selecttolimittheamountofmeltingrun
time.
Default=3.0days