Watts 654 User guide

Category
Thermostats
Type
User guide

This manual is also suitable for

Watts 654 is a versatile snow melting control system that provides automatic and manual operation, allowing you to customize snow melting based on your needs.

Automatic start and stop operation: The 654 automatically starts melting snow or ice when detected by a snow sensor and stops when the surface is dry, ensuring efficient and effective snow removal.

Manual operation: You can also manually start the snow melting process using the Melt key on the control display, giving you complete control over when and how long the system operates.

Multiple zone control: The 654 can control multiple zones, allowing you to customize the snow melting operation for different areas. Zones without sensors can repeat the run time of a primary zone, ensuring consistent melting across your property.

Watts 654 is a versatile snow melting control system that provides automatic and manual operation, allowing you to customize snow melting based on your needs.

Automatic start and stop operation: The 654 automatically starts melting snow or ice when detected by a snow sensor and stops when the surface is dry, ensuring efficient and effective snow removal.

Manual operation: You can also manually start the snow melting process using the Melt key on the control display, giving you complete control over when and how long the system operates.

Multiple zone control: The 654 can control multiple zones, allowing you to customize the snow melting operation for different areas. Zones without sensors can repeat the run time of a primary zone, ensuring consistent melting across your property.



of4 ©203WattsRadiant
Thisbrochurewillprovideyouwiththeinformationyouneedtobenefitthemostfromyoursnowmeltingcontrol.Pleasevisit
www.WattsRadiant.comformoredetailedinformationonthisoranyotherWattsRadiantproduct.


ENTER
HomeButton
ReturntotheHomeScreen
Pressandholdfor3
secondstoaccessthe
programmingmenus.
Touchtogotothenextsetting
Touchtoquicklyenter
theViewmenu
Touchtoadjustsettings
Touchtoturnsystem
offwhileaway
OperationField
StatusField
Touchtodisplay
RunTime,
Outdoor&Slab
Temperature
Touchto
MeltorStop

Heatisturnedon.

Communicationispresent.

Indicatesanerrorispresent.

Adjustthedisplayedsetting.
MELT
Systemismeltingsnoworice.
IDLE
Systemisidling.
STRM
Systemisinstormoperation.
OFF
Systemisoff.
WWSD
WarmWeatherShutDown.Theslabisnaturally
warmenoughtomeltsnoworice.
CWCO
ColdWeatherCutOut.Toocoldtomelt.
TIMED
Timedmeltingoperation.Systemoperatesuntil
timehaselapsed.
WARM
Slabiswarminguptothemeltingtemperature.
AWAY
Awayscene.Nomeltinguntiltheawaysceneis
exited.
PEND
Pending.Thesystemhasdetectedwaterbutitistoo
coldtooperateorthescheduleisinIdleorOff.
WAIT
Zonepriorityineffect.Zonemustwaituntilhigher
priorityzonefinishesmelting.
SENSOR
Tandem090sensor.
TRACK
Thiszonetracksthemeltingoperationofzone.




PG-WR-Snow_Melting_Control-654328 2of4
Snowmeltingoperationcanbestartedmanuallyorautomatically
dependingonwhichsensorsareinstalled.Automaticstartand
stopoperationrequiresaSnow/IceSensor090.Automatic
startwithatimedstoprequiresaSnowSensor095.

-----------------------------------
TouchtheMeltkeyonthecontroldisplay.Thecontrolusesa
timertooperatethesnowmeltingsystemandshutsoffwhen
thetimerhasexpired.
Press
Melt

---------------------------
Thesystemautomaticallystartsassoonassnoworiceis
detectedandstopswhentheslabisdry.ASnow/IceSensor
090isrequiredforautomaticstartandstopoperation.

------------------------------------------
WhenaSnow/IceSensorisinstalled,thecontrolhasthe
optiontoEconoMelt.Thisallowsthesnowtobemechanically
removedusingaploworshovelandthenmanuallystarting
thesnowmeltingsystemtomelttheremaininglastthinlayer
ofsnoworice.Thesystemoperatesuntilthesensorisdry.

---------------------------------------------
Thesnowmeltingsystemcanhavemultiplezones.Zones
withoutasnow/icesensororsnowsensorcanrepeatthe
runtimeofzone.
Zone
TrackMeltStartandStop
Records
Run Time
Snow / Ice
Sensor
Slab
Sensor
Slab
Sensor
Zone2 Zone3
Repeats
Zone 1 Run
Time + Add
Melt Time
Repeats
Zone 1 Run
Time + Add
Melt Time

---------------------------
Thesnowmeltingsystemcanstartandstopbasedupona
programmableschedule.WhilethescheduleisinEvent
(wake)or3(occupied),thecontrolisinmeltoperation.When
thescheduleisinEvent2(unoccupied)or4(sleep)thecontrol
isinidleoroffoperation.

---------------------------------------
Idleoperationpre-heatstheslabwhenevertheslabisbelow
freezing.Thisallowstheslabtoquicklywarmuptothe
meltingtemperatureincasesnoworiceisdetected.Idling
requiresalargeamountofenergyandisrecommenedfor
commercialorinstitutionalinstallationswheresafetyconcerns
areparamount.
Snow/Ice
Sensor090
Snow
Sensor
095

--------------------
Thesystemautomaticallystartsassoonassnoworiceis
detectedandstopswhentheManualMeltRunTimecounter
haselasped.TheManualMeltRunTimesettingisadjustable
intheSetTempmenu.ASnowSensor095isrequiredfor
automaticstartandtimedoperation.

3of4 ©203WattsRadiant
ThiscontrolincludesanAwayKeytoquicklydisablethe
snowmeltingsystem,andwhenconnectedtoatekmarNet
®
system,canalsoturndowntheheatingtemperatureonall
thermostatsandsuspendheatingthedomestichotwater
tanktomaximizeenergysavings.ToturnontheAwayKey,
gototheScenemenu.
ToactivatetheAwayscene,touchGoingAway”onthe
screen.
SelectPERM(permanent)oranumberofdaysusingthe
or arrow.Rangeisto80days.
Pressthehomebuttontoacceptthesettingorleavethe
screenuntouchedforseveralseconds.
“SceneAway”isdisplayedonthehomescreenuntilthe
numberofdaysexpires.
Touch“CancelAway”tocancelatanytime.
IfaUserSwitchhasbeeninstalled,pressthe‘Storm’button
topre-heattheslabintheeventofasnowfallwarning.Ifno
snowisdetectedorthesystemisnotmanuallystartedduring
thepre-settime,thesystemwillshutoff.Ifsnowisdetected,
theslabtemperaturewillbeincreasedtoprovidesnowmelting.
ASnow/IceSensor090oraSlabSensor072isrequired
forStormoperation.
Melt
Away
Storm
Press
Storm
PressandholdtheHomebuttonfor3secondstoentertheprogrammingmenus.Thecontrolreturnstothelastprogramming
menupreviouslyused.
Pressand
holdfor3
secondsto
accessthe
programming
menus.

-------------
Touch“NEXT”toadvance(clockwisein
illustration)tothenextmenu.
Touch“BACK”togobackwards
(counterclockwiseinillustration)throughthe
menus.
Touch“ENTER”toenteramenu.

-----------------------------
  

Touch“NEXTITEM”toadvancetothenextitem
withinthemenu.
TouchBACKITEM”togobackwardstothe
previousitemwithinthemenu.
Toreturntotheparentmenuafterchanginga
setting,pressandreleasetheHomebutton.
ToreturntotheHomescreen,pressandrelease
theHomebuttontwiceorwait30secondsto
automaticallyreturntotheHomescreen.



A Watts Water Technologies Company
Springeld,MO•Tel.(800)276-249•Fax:(47)864-86•www.wattsradiant.com
Burlington,ONT.•Tel.(905)332-4090•Fax:(905)332-7068•www.watts.ca
PG-WR-Snow_Melting_Control-654328 ©203WattsRadiant
ThisProductGuidecontainsstandardinformationonhowtomakeadjustmentstoaninstalledproduct.Moredetailedinformationcan
befoundinthisproductsInstallationandOperationManual(IOM-WR-Snow_Melting_Control-654)atwww.WattsRadiant.com
WARNING:ThisproductcontainschemicalsknowntotheStateofCaliforniatocausecancerandbirthdefectsorotherreproductiveharm.Formore
information:www.watts.com/prop65

------------------------------------------
Displayscurrentoperatingtemperaturesandstatusinformation
ofthesystem.
-ThesnowmeltzonenumberonthetekmarNet
®
system.
-Currentoutdoorairtemperatureasmeasuredby
theoutdoorsensor.
-Currentslabtemperatureasmeasuredbythecontrol.
-Currentstatusofthewaterdetectionsensor.
-Currentstatusoftheheatrelay.
-Currentstatusofthesystempumprelay.
-Currentstatusofthealertrelay.
-Theremainingruntimebefore
shuttingoff.
-Theremainingruntimeafterthesensor
isdrywhenusingautomaticoperation.

--------------------------------------
TheSetTempmenuitemsselecttheoperatingtemperatures
ofthesnowmeltsystem.
-Selectthedesiredsurfacetemperatureofthe
snowmeltsurfacewhenmelting.Thefactorydefaultis36°F
or2.0°C.
-Selecttheamountofrunningtime
whenmanuallystartingthesystem.

------------------------------------------
Thecontrolhasabuilt-intimeclocktoallowthecontrolto
operateonaschedule.Abattery-lessbackupallowsthecontrol
tokeeptimeforupto4hourswithoutpower.Thetimeclock
supportsautomaticadjustmentforDaylightSavingTime(DST)
oncetheday,monthandyearareentered.UsetheTimemenu
tosetthecorrecttime,day,monthandyear.

--------------------------------------
Thiscontrolcanoperateonaprogrammableschedule.During
Eventor3thesystemisinMeltoperation.DuringEvent2
or4thesystemisinIdleorOffoperation.

Turningofftheschedule(OFF)
Operateaschedulethatappliesonlytothesnowmelt
systemoperatedbythiscontrol(ZONE)
Theabilitytooperateoneofthefoursystem-wideschedules
asamaster(ScheduleMasterthrough4*)
Joinoneofthefoursystem-wideschedulesasamember
(ScheduleMemberthough4*)
*RequiresthecontroltobeconnectedtoatekmarNet
®
system.
Oncethetypeofschedulehasbeenselected,thecontrolcan
supportschedulesthathaveeither2or4eventsperday.

----------------------------------------
-SelecttemperatureunitsindegreesFahrenheitor
Celsius.
-Selecthowthedisplaybacklight
operates.
ON=Alwayson.
ONMELT=
Onwhenmelting,offwhennotmelting.This
providesavisualindicatortoindicatethatthesnowmelting
systemiscurrentlymelting.
OFF=Alwaysoff.

-----------------------------------------
-Scenesprovidesystem-wideoverridestosave
energy.Selectwhetherscenesarenotused(none)orifthe
awaysceneisavailable.
-Ifscenesareavailable,selectiftheawaykeyis
availableornot.

---------------------------------------
-Recordsthenumberofrunninghourssincethe
itemwaslastreset.TouchthenumberandthentheENTER
keytoresettozero.
-Recordsthesystempumprunning
hourssincetheitemwaslastreset.Touchthenumberand
thentheENTERkeytoresettozero.

---------------------------------------
-Changetheaccesslevelonthethermostat.
-Displaythesoftware
“SW”andthe“TYPE”number.

----------------------------------------
EnteringtheScreenCleanmenuprovides30secondsto
cleanthethermostatanddisplaywithamoistcloth.Donot
usesolventstocleanthethermostat.


  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Watts 654 User guide

Category
Thermostats
Type
User guide
This manual is also suitable for

Watts 654 is a versatile snow melting control system that provides automatic and manual operation, allowing you to customize snow melting based on your needs.

Automatic start and stop operation: The 654 automatically starts melting snow or ice when detected by a snow sensor and stops when the surface is dry, ensuring efficient and effective snow removal.

Manual operation: You can also manually start the snow melting process using the Melt key on the control display, giving you complete control over when and how long the system operates.

Multiple zone control: The 654 can control multiple zones, allowing you to customize the snow melting operation for different areas. Zones without sensors can repeat the run time of a primary zone, ensuring consistent melting across your property.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI